Temperature distribution over the absorber plate of a parallel flow flat-plate solar collector is numerically analyzed. The governing differential equations with boundary conditions are solved numerically using fluent...Temperature distribution over the absorber plate of a parallel flow flat-plate solar collector is numerically analyzed. The governing differential equations with boundary conditions are solved numerically using fluent software. Effects of the inlet mass flux, inlet temperature and tube spacing on velocity and temperature distributions are discussed. Numerical results show that the distributions of velocity and temperature of fluid is unsymmetrical inside pipe.展开更多
This paper presents an experimental study on a flat plate closed loop pulsating heat pipes. It consisted of total 40 channels with square cross section (2 × 2 mm^2, 165 mm long) machined directly on an aluminum...This paper presents an experimental study on a flat plate closed loop pulsating heat pipes. It consisted of total 40 channels with square cross section (2 × 2 mm^2, 165 mm long) machined directly on an aluminum plate(180×120×3 nm^2), which was covered by a transparent plate. The working fluid employed was ethanol. As the results, the influence parameters of thermal performance were investigated, such as filling ratio, heat load and operational orientations etc. Filling ratio was found to be a critical parameter, and its effect was rather complicated. According to its values the PHP plate could have four distinct working zones with different operational characteristics and heat transfer performance. The effect of heat load on thermal performance was found to be positive, and in general, iucrcasing the heat load would improve heat transfer performance. In order to analyze the effect of gravity on thermal performance, three different heat modes and total seven tilt angles were tested and compared. Successful operation at all orientations with respect to gravity was also achieved.展开更多
An innovative flat heat pipe radiator was put forward, and it has the features of high efficiency of heat dissipation, compact construction, low thermal resistance, light weight, low cost, and anti-dust-deposition. Th...An innovative flat heat pipe radiator was put forward, and it has the features of high efficiency of heat dissipation, compact construction, low thermal resistance, light weight, low cost, and anti-dust-deposition. The thermal analysis of the flat heat pipe radiator for cooling high-power light emitting diode (LED) array was conducted. The thermal characteristics of the flat heat pipe radiator under the different heat loads and incline angles were investigated experimentally in natural convection. An electro-thermal conversion method was used to measure the junction temperature of the LED chips. It is found that the integral temperature distribution of the flat heat pipe radiator is reasonable and uniform. The total thermal resistance of the flat heat pipe radiator varies in the range of 0.38-0.45 K/W. The junction temperatures of LED chips with the flat heat pipe radiator and with the aluminum board at the same forward current of 0.35 A are 52.5 and 75.2 ℃, respectively.展开更多
Flat plate pulsating heat pipe is useful for hot spot heat spreader. Two kinds of flat plate spreader of pulsating heat pipe are designed, fabricated and experimented. For the embedded circular capillary type, the tra...Flat plate pulsating heat pipe is useful for hot spot heat spreader. Two kinds of flat plate spreader of pulsating heat pipe are designed, fabricated and experimented. For the embedded circular capillary type, the transferred heat flux could reach 32 W/cm2, the smallest thermal resistance for acetone, methanol and FC-72 were respectively 0.50, 0.57 and 0.40℃/W. While for the square capillary type, the transferred heat flux could reach 26 W/cm2, the equivalent thermal conductivity could reach 3211 W/(m. ℃). There are ranges of optimal transferred power and filling ratio for different working liquid. If the transferred power is constant, changing the heating area and the place has little effects on the performance.展开更多
This paper introduces a novel fiat plate solar collector (FPC) using micro heat pipe array (MHPA) as a key element. To analyze the thermal transfer behavior of flat plate solar collector with micro heat pipe array...This paper introduces a novel fiat plate solar collector (FPC) using micro heat pipe array (MHPA) as a key element. To analyze the thermal transfer behavior of flat plate solar collector with micro heat pipe array (MHPA-FPC), an indoor experiment for thermal transfer characteristic of MHPA applied to FPC was conducted by using an electrical heating film to simulate the solar radiation. Different cooling water flow rates, cooling water temperatures, slopes, and contact thermal resistances be- tween the condenser of MHPA and the heat exchanger were tested at different heating powers. The experimental results in- dicate that MHPA-FPC exhibits the enhanced heat transfer capability with increased cooling water flow rate and temperature. Total thermal resistance has a maximum decline of approximately 10% when the flow rate increases from 180 to 360 L h-1 and 38% when the cooling water temperature increases from 20~C to 40~C. When the inclination angle of MHPA-FPC ex- ceeds 30~, the slope change has a negligible effect on the heat transfer performance of MHPA-FPC. In addition, contact thermal resistance significantly affects the heat transfer capability of MHPA-FPC. The total thermal resistances lowers to nearly half of the original level when contact material between the condenser of MHPA and the heat exchanger changes from conductive silicone to conductive grease. These results could provide useful information for the optimal design and operation of MHPA-FPC.展开更多
The shell and tube heat exchanger is an essential part of a power plant for recovering heat transfer between the feed water of a boiler and the wasted heat.The baffles are also an important element inside the heat exc...The shell and tube heat exchanger is an essential part of a power plant for recovering heat transfer between the feed water of a boiler and the wasted heat.The baffles are also an important element inside the heat exchanger.Internal materials influence the flow pattern in the bed.The influence of baffles in the velocity profiles was observed using a three-dimensional particle image velocimetry around baffles in a horizontal circular tube.The velocity of the particles was measured before the baffle and between them in the test tube.Results show that the flows near the front baffle flow were parallel to the vertical wall,and then concentrate on the upper opening of the front baffle.The flows circulate in the front and rear baffles.These flow profiles are related to the Reynolds number(Re) or the flow intensity.The velocity profiles at lower Re number showed a complicated mixing,concentrating on the lower opening of the rear baffle as front wall.Swirling flow was employed in this study,which was produced using tangential velocities at the inlet.At the entrance of the front baffle,the velocity vector profiles with swirl were much different from that without swirl.However,velocities between two baffles are not much different from those without swirl.展开更多
An experimental system of flat plate pulsating heat pipe was established and experimental research was carried out in this system to know the mechanism of heat transfer, start-up and operating characteristics. The fac...An experimental system of flat plate pulsating heat pipe was established and experimental research was carried out in this system to know the mechanism of heat transfer, start-up and operating characteristics. The factors, such as filling rate, heating power, heating method etc, which have great influence on the thermal performance of the plate pulsating heat pipe were discussed. The results indicate that heating power and filling rate are the important factors for the start-up of the plate pulsating heat pipe. The different start-up power is needed with different filling rate, and the start-up of the heat pipe in case of bottom heated is much easier than that of top heated. Increasing the heating power and enlarging the heating area can make the start-up easier. Heating power can also affect the start-up time of heat pipe under the condition of bottom heated, while it does not have some influence to the heat pipe of top heated. The thermal resistance of plate pulsating heat pipe is related with the heating power, and the higher the heating power is, the smaller the thermal resistance is. But the best filling rate which the heat pipe needs is different with different heating methods, and the performance of the heat pipe in the case of bottom heated is better than the others.展开更多
OBJECTIVE: To study the daily administration times of Canhuang tablet(CHT) for treating jaundice in rats based on a pharmacodynamic/ pharmacokinetic model.METHODS: Rats were modeled by 4% 1-Naphthylisothiocyanate(75 m...OBJECTIVE: To study the daily administration times of Canhuang tablet(CHT) for treating jaundice in rats based on a pharmacodynamic/ pharmacokinetic model.METHODS: Rats were modeled by 4% 1-Naphthylisothiocyanate(75 mg/kg, p.o.). After 48 h, CHT was given(p.o.) at 0.75 g/kg once a day, 0.375 g/kg twice a day, and 0.25 g/kg three times a day. Blood was collected from the orbital sinus at different intervals. Levels of liver enzymes and bilirubin were detected using these blood samples. Bile was collected and determined after the first administration of CHT. High-performance liquid chromatography was used to determine the concentration of berberine in bile simultaneously. Time-effect and time-dose curves were then obtained.RESULTS: Compared with rats taking CHT twiceand three times a day, the total amount of bile within 10 h of rats taking CHT once a day were 1.32-and 1.47-fold higher, respectively. There was good consistency between the pharmacokinetics of berberine and the pharmacodynamics of the effect on liver enzymes and bilirubin in vivo. The pharmacokinetic analyses showed that rats administered CHT once daily maintained a higher concentration of berberine in bile for a longer period than rats administered CHT two- and three-times daily.CONCLUSION: In jaundiced rats, taking CHT once a day is better than taking CHT twice or three times a day. These data may provide a reference for the clinical application of CHT.展开更多
文摘Temperature distribution over the absorber plate of a parallel flow flat-plate solar collector is numerically analyzed. The governing differential equations with boundary conditions are solved numerically using fluent software. Effects of the inlet mass flux, inlet temperature and tube spacing on velocity and temperature distributions are discussed. Numerical results show that the distributions of velocity and temperature of fluid is unsymmetrical inside pipe.
基金Supported by the Ger man National Science Foundation (DFG)(No. GR412/33)
文摘This paper presents an experimental study on a flat plate closed loop pulsating heat pipes. It consisted of total 40 channels with square cross section (2 × 2 mm^2, 165 mm long) machined directly on an aluminum plate(180×120×3 nm^2), which was covered by a transparent plate. The working fluid employed was ethanol. As the results, the influence parameters of thermal performance were investigated, such as filling ratio, heat load and operational orientations etc. Filling ratio was found to be a critical parameter, and its effect was rather complicated. According to its values the PHP plate could have four distinct working zones with different operational characteristics and heat transfer performance. The effect of heat load on thermal performance was found to be positive, and in general, iucrcasing the heat load would improve heat transfer performance. In order to analyze the effect of gravity on thermal performance, three different heat modes and total seven tilt angles were tested and compared. Successful operation at all orientations with respect to gravity was also achieved.
基金Project(50876016) support by the National Natural Science Foundation of China
文摘An innovative flat heat pipe radiator was put forward, and it has the features of high efficiency of heat dissipation, compact construction, low thermal resistance, light weight, low cost, and anti-dust-deposition. The thermal analysis of the flat heat pipe radiator for cooling high-power light emitting diode (LED) array was conducted. The thermal characteristics of the flat heat pipe radiator under the different heat loads and incline angles were investigated experimentally in natural convection. An electro-thermal conversion method was used to measure the junction temperature of the LED chips. It is found that the integral temperature distribution of the flat heat pipe radiator is reasonable and uniform. The total thermal resistance of the flat heat pipe radiator varies in the range of 0.38-0.45 K/W. The junction temperatures of LED chips with the flat heat pipe radiator and with the aluminum board at the same forward current of 0.35 A are 52.5 and 75.2 ℃, respectively.
文摘Flat plate pulsating heat pipe is useful for hot spot heat spreader. Two kinds of flat plate spreader of pulsating heat pipe are designed, fabricated and experimented. For the embedded circular capillary type, the transferred heat flux could reach 32 W/cm2, the smallest thermal resistance for acetone, methanol and FC-72 were respectively 0.50, 0.57 and 0.40℃/W. While for the square capillary type, the transferred heat flux could reach 26 W/cm2, the equivalent thermal conductivity could reach 3211 W/(m. ℃). There are ranges of optimal transferred power and filling ratio for different working liquid. If the transferred power is constant, changing the heating area and the place has little effects on the performance.
基金financially supported by the Natural Science Foundation of Beijing(Grant No.Z1004020201201)the Opening Funds of State Key Laboratory of Building Safety and Build Environment of China(Grant No.BSBE 2011-07)
文摘This paper introduces a novel fiat plate solar collector (FPC) using micro heat pipe array (MHPA) as a key element. To analyze the thermal transfer behavior of flat plate solar collector with micro heat pipe array (MHPA-FPC), an indoor experiment for thermal transfer characteristic of MHPA applied to FPC was conducted by using an electrical heating film to simulate the solar radiation. Different cooling water flow rates, cooling water temperatures, slopes, and contact thermal resistances be- tween the condenser of MHPA and the heat exchanger were tested at different heating powers. The experimental results in- dicate that MHPA-FPC exhibits the enhanced heat transfer capability with increased cooling water flow rate and temperature. Total thermal resistance has a maximum decline of approximately 10% when the flow rate increases from 180 to 360 L h-1 and 38% when the cooling water temperature increases from 20~C to 40~C. When the inclination angle of MHPA-FPC ex- ceeds 30~, the slope change has a negligible effect on the heat transfer performance of MHPA-FPC. In addition, contact thermal resistance significantly affects the heat transfer capability of MHPA-FPC. The total thermal resistances lowers to nearly half of the original level when contact material between the condenser of MHPA and the heat exchanger changes from conductive silicone to conductive grease. These results could provide useful information for the optimal design and operation of MHPA-FPC.
基金supported by the RESEAT program funded by the Ministry of Science,ICT and Future Planning through the National Research Foundation of Koreaby the National Research Laboratory Program of the National Research Foundation(No.2008-0060153)of Korea
文摘The shell and tube heat exchanger is an essential part of a power plant for recovering heat transfer between the feed water of a boiler and the wasted heat.The baffles are also an important element inside the heat exchanger.Internal materials influence the flow pattern in the bed.The influence of baffles in the velocity profiles was observed using a three-dimensional particle image velocimetry around baffles in a horizontal circular tube.The velocity of the particles was measured before the baffle and between them in the test tube.Results show that the flows near the front baffle flow were parallel to the vertical wall,and then concentrate on the upper opening of the front baffle.The flows circulate in the front and rear baffles.These flow profiles are related to the Reynolds number(Re) or the flow intensity.The velocity profiles at lower Re number showed a complicated mixing,concentrating on the lower opening of the rear baffle as front wall.Swirling flow was employed in this study,which was produced using tangential velocities at the inlet.At the entrance of the front baffle,the velocity vector profiles with swirl were much different from that without swirl.However,velocities between two baffles are not much different from those without swirl.
基金support of this work by the National Natural Science Foundation of China (No.50776006)
文摘An experimental system of flat plate pulsating heat pipe was established and experimental research was carried out in this system to know the mechanism of heat transfer, start-up and operating characteristics. The factors, such as filling rate, heating power, heating method etc, which have great influence on the thermal performance of the plate pulsating heat pipe were discussed. The results indicate that heating power and filling rate are the important factors for the start-up of the plate pulsating heat pipe. The different start-up power is needed with different filling rate, and the start-up of the heat pipe in case of bottom heated is much easier than that of top heated. Increasing the heating power and enlarging the heating area can make the start-up easier. Heating power can also affect the start-up time of heat pipe under the condition of bottom heated, while it does not have some influence to the heat pipe of top heated. The thermal resistance of plate pulsating heat pipe is related with the heating power, and the higher the heating power is, the smaller the thermal resistance is. But the best filling rate which the heat pipe needs is different with different heating methods, and the performance of the heat pipe in the case of bottom heated is better than the others.
基金Supported by the Shibingshiyao Program of Beijing Municipal Science and Technology Commission(No.Z131100002513005)
文摘OBJECTIVE: To study the daily administration times of Canhuang tablet(CHT) for treating jaundice in rats based on a pharmacodynamic/ pharmacokinetic model.METHODS: Rats were modeled by 4% 1-Naphthylisothiocyanate(75 mg/kg, p.o.). After 48 h, CHT was given(p.o.) at 0.75 g/kg once a day, 0.375 g/kg twice a day, and 0.25 g/kg three times a day. Blood was collected from the orbital sinus at different intervals. Levels of liver enzymes and bilirubin were detected using these blood samples. Bile was collected and determined after the first administration of CHT. High-performance liquid chromatography was used to determine the concentration of berberine in bile simultaneously. Time-effect and time-dose curves were then obtained.RESULTS: Compared with rats taking CHT twiceand three times a day, the total amount of bile within 10 h of rats taking CHT once a day were 1.32-and 1.47-fold higher, respectively. There was good consistency between the pharmacokinetics of berberine and the pharmacodynamics of the effect on liver enzymes and bilirubin in vivo. The pharmacokinetic analyses showed that rats administered CHT once daily maintained a higher concentration of berberine in bile for a longer period than rats administered CHT two- and three-times daily.CONCLUSION: In jaundiced rats, taking CHT once a day is better than taking CHT twice or three times a day. These data may provide a reference for the clinical application of CHT.