Since the gas infrared absorption spectrum source intensity of several in a thousand, it is even less linewidth is only several nanometers occupying the than the noise of light source. The signal of gas absorption is ...Since the gas infrared absorption spectrum source intensity of several in a thousand, it is even less linewidth is only several nanometers occupying the than the noise of light source. The signal of gas absorption is submerged in the noise, so it is impossible to measure the concentration of gas with spectrum absorption directly. According to the principle and parameters of difference absorption system of CH4 gas, a detection circuit consisted of the lock-in amplifier is designed. The experiment results indicated that the detection circuit can satisfy the demand of the whole system, and the limit concentration is 150×10^-6.展开更多
A method of implementing high cost-effective and highly integrated digital lock-in amplifier with microcontroller is discussed. And the digital lock-in amplifier is more suitable for meastwing lowfrequency weak signal...A method of implementing high cost-effective and highly integrated digital lock-in amplifier with microcontroller is discussed. And the digital lock-in amplifier is more suitable for meastwing lowfrequency weak signal. Digital signal sequence is obtained through sampling signal measured over an integer number of signal periods, but digital reference sequence is acquired through mathematical operation, then digital phase sensitive detection can be implemented by calculating the cross-correlation function of digital signal sequence and digital reference sequence. In addition, the frequency response and phase character of the digital lock-in amplifier is analyzed. Finally, the designed digital lock-in amplifier is achieved. Expermental results show that the digital lock-in amplifier can be used for measuring weak signal with low ignal-to-noise ratio.展开更多
基金Doctorate Foundation of Hebei Province(03547020D) Natural Science Foundation of Heilongjiang Province(F0312)
文摘Since the gas infrared absorption spectrum source intensity of several in a thousand, it is even less linewidth is only several nanometers occupying the than the noise of light source. The signal of gas absorption is submerged in the noise, so it is impossible to measure the concentration of gas with spectrum absorption directly. According to the principle and parameters of difference absorption system of CH4 gas, a detection circuit consisted of the lock-in amplifier is designed. The experiment results indicated that the detection circuit can satisfy the demand of the whole system, and the limit concentration is 150×10^-6.
文摘A method of implementing high cost-effective and highly integrated digital lock-in amplifier with microcontroller is discussed. And the digital lock-in amplifier is more suitable for meastwing lowfrequency weak signal. Digital signal sequence is obtained through sampling signal measured over an integer number of signal periods, but digital reference sequence is acquired through mathematical operation, then digital phase sensitive detection can be implemented by calculating the cross-correlation function of digital signal sequence and digital reference sequence. In addition, the frequency response and phase character of the digital lock-in amplifier is analyzed. Finally, the designed digital lock-in amplifier is achieved. Expermental results show that the digital lock-in amplifier can be used for measuring weak signal with low ignal-to-noise ratio.