Concrete dam construction, reservoir impoundment and operation are a complicated and long-term process. During the course of this process dam suffers lots of factors including changing temperature, humidity, deformati...Concrete dam construction, reservoir impoundment and operation are a complicated and long-term process. During the course of this process dam suffers lots of factors including changing temperature, humidity, deformation, loads and restraints around dam. With time going by, damage to darn concrete happens. As a result, the strength, stiffness and resistance of concrete will decrease accompanying with damage accumulation and dam structure performance behavior and lifetime will be shorten or even destructed. At present, most of researches focus on concrete material itself and seldom consider effects of water content for concrete structures. That is apparently inconsistent with the actual situation. In engineering practice, it is urgently needed to assess existing dam structure damage state considering dry zoning in concrete. Through taking C30 dam concrete as standard specimen, alternate freezing and thawing tests are undertaken and changing law of time-dependent concrete damage state resulting in alternate wetting and drying has been studied in this paper. And then calculation formulas of time-dependent concrete damage evolution process considering alternate wetting and drying under condition of freeze-thaw cycle tests are established. Combining with four parameters Hsieh-Ting-Chen ( H -T-C ) model, some relevant factors or parameters are obtained through indoor testing and life prediction model of concrete dam based on dry zoning and damage theory is put forward which provides technical supports for dam safety evaluation and management of sustainable development.展开更多
A novel method,i.e.multi-cyclic quenching and partitioning(M-Q-P)heat treatment,is used to tailor the content of retained austenite(RA)in commercial steels.For 35CrMnSi steel,5 times of Q-P heat treatment can increase...A novel method,i.e.multi-cyclic quenching and partitioning(M-Q-P)heat treatment,is used to tailor the content of retained austenite(RA)in commercial steels.For 35CrMnSi steel,5 times of Q-P heat treatment can increase the content of RA from 8vol.%to 17 vol.%.As a result,the ultimate elongation of the steel is improved from 17.4%after the typical Q-P heat treatment to 27.1%after 5 times of Q-P treatment.Meanwhile,the improved combination of strength and ductility for steels by typical Q-P heat treatment is retained by the multi-cyclic Q-P heat treatment.It is shown that the content of RA in some specific steels,and furthermore their mechanical properties,can be regulated through the M-Q-P.展开更多
基金This research was supported by NSFC (National Natural Science Foundation of China) (Granted No.: 50909054, 50925933).
文摘Concrete dam construction, reservoir impoundment and operation are a complicated and long-term process. During the course of this process dam suffers lots of factors including changing temperature, humidity, deformation, loads and restraints around dam. With time going by, damage to darn concrete happens. As a result, the strength, stiffness and resistance of concrete will decrease accompanying with damage accumulation and dam structure performance behavior and lifetime will be shorten or even destructed. At present, most of researches focus on concrete material itself and seldom consider effects of water content for concrete structures. That is apparently inconsistent with the actual situation. In engineering practice, it is urgently needed to assess existing dam structure damage state considering dry zoning in concrete. Through taking C30 dam concrete as standard specimen, alternate freezing and thawing tests are undertaken and changing law of time-dependent concrete damage state resulting in alternate wetting and drying has been studied in this paper. And then calculation formulas of time-dependent concrete damage evolution process considering alternate wetting and drying under condition of freeze-thaw cycle tests are established. Combining with four parameters Hsieh-Ting-Chen ( H -T-C ) model, some relevant factors or parameters are obtained through indoor testing and life prediction model of concrete dam based on dry zoning and damage theory is put forward which provides technical supports for dam safety evaluation and management of sustainable development.
文摘A novel method,i.e.multi-cyclic quenching and partitioning(M-Q-P)heat treatment,is used to tailor the content of retained austenite(RA)in commercial steels.For 35CrMnSi steel,5 times of Q-P heat treatment can increase the content of RA from 8vol.%to 17 vol.%.As a result,the ultimate elongation of the steel is improved from 17.4%after the typical Q-P heat treatment to 27.1%after 5 times of Q-P treatment.Meanwhile,the improved combination of strength and ductility for steels by typical Q-P heat treatment is retained by the multi-cyclic Q-P heat treatment.It is shown that the content of RA in some specific steels,and furthermore their mechanical properties,can be regulated through the M-Q-P.