In order to increase the productivity of microreactors, the parallelization of the microreactors is required. The performances of flow distributors can affect the product yield and fault detection ability when blockag...In order to increase the productivity of microreactors, the parallelization of the microreactors is required. The performances of flow distributors can affect the product yield and fault detection ability when blockage happens.In this research, an optimal design method to calculate the channel diameters and to determine the flow sensor location is derived based on mass balance and pressure balance models of split-and-recombine-type flow distributors(SRFDs). The model accuracy is verified by experiment data. The proposed method is applied to optimal design of SRFDs under constant flow rate operation conditions. The maximum angle difference between normal and blockage conditions at one sensor to those at the other sensors is set to be the objective function and the uniformity of flow distribution in microreactors under normal condition is also required. The diameters of each pipe in SRFDs are selected as the design variables. Simulated annealing algorithm is used to solve the optimization problem. The effectiveness of the optimal design results is demonstrated by fluid dynamics simulations. The results show that using the optimal channel diameters of SRFDs, the pressure drop in SRFD section is lower than that of the microreactor section. Meanwhile, in the case studies, only a few sensors that are located inside the SRFDs can easily detect the blockage abnormal condition in the parallelized microreactor system.展开更多
Entrance region may have important effect on gases flow characteristics in micro-channels. It's concluded in the available papers that the entrance effect causes significant difference. An experimental system of s...Entrance region may have important effect on gases flow characteristics in micro-channels. It's concluded in the available papers that the entrance effect causes significant difference. An experimental system of single-phase gas flow characteristics in microchannels was set up. Flow characteristics of nitrogen in PEEK polymer micro-tube (hydraulic diameter is 553btm) was studied experimentally. According to the data of nitrogen flow in the micro-tube with the length ranging from 0. 1m to1.524m, it is shown that the friction constant becomes higher when the tube becomes shorter. By using pipe cutting methods, it's confirmed that entrance effect is one of the key factors that cause friction constant higher than conventional theory. It's found that friction constant of fully developed flow is lower than the value predicted by conventional theory in turbulent region. The result indicates that the flow transition occurs at Reynolds number ranging from 1600-2000. The phenomenon of obvious early transition is not found.展开更多
Given a system of vector fields on a smooth manifold that spans a plane field of constant rank, we present a systematic method and an algorithm to find submanifolds that are invariant under the flows of the vector fie...Given a system of vector fields on a smooth manifold that spans a plane field of constant rank, we present a systematic method and an algorithm to find submanifolds that are invariant under the flows of the vector fields. We present examples of partition into invariant submanifolds, which further gives partition into orbits. We use the method of generalized Frobenius theorem by means of exterior differential systems.展开更多
基金Supported by the National Natural Science Foundation of China(21466026,61364009)NJZZ(14054)
文摘In order to increase the productivity of microreactors, the parallelization of the microreactors is required. The performances of flow distributors can affect the product yield and fault detection ability when blockage happens.In this research, an optimal design method to calculate the channel diameters and to determine the flow sensor location is derived based on mass balance and pressure balance models of split-and-recombine-type flow distributors(SRFDs). The model accuracy is verified by experiment data. The proposed method is applied to optimal design of SRFDs under constant flow rate operation conditions. The maximum angle difference between normal and blockage conditions at one sensor to those at the other sensors is set to be the objective function and the uniformity of flow distribution in microreactors under normal condition is also required. The diameters of each pipe in SRFDs are selected as the design variables. Simulated annealing algorithm is used to solve the optimization problem. The effectiveness of the optimal design results is demonstrated by fluid dynamics simulations. The results show that using the optimal channel diameters of SRFDs, the pressure drop in SRFD section is lower than that of the microreactor section. Meanwhile, in the case studies, only a few sensors that are located inside the SRFDs can easily detect the blockage abnormal condition in the parallelized microreactor system.
基金supported by the National Natural Science Foundation of China (No. 50776006)"863" plan (No. 2006AA05Z228)Technological Innova tion Fund of Excellent Doctoral Candidate of Beijing Jiaotong University (No. 48013)
文摘Entrance region may have important effect on gases flow characteristics in micro-channels. It's concluded in the available papers that the entrance effect causes significant difference. An experimental system of single-phase gas flow characteristics in microchannels was set up. Flow characteristics of nitrogen in PEEK polymer micro-tube (hydraulic diameter is 553btm) was studied experimentally. According to the data of nitrogen flow in the micro-tube with the length ranging from 0. 1m to1.524m, it is shown that the friction constant becomes higher when the tube becomes shorter. By using pipe cutting methods, it's confirmed that entrance effect is one of the key factors that cause friction constant higher than conventional theory. It's found that friction constant of fully developed flow is lower than the value predicted by conventional theory in turbulent region. The result indicates that the flow transition occurs at Reynolds number ranging from 1600-2000. The phenomenon of obvious early transition is not found.
基金supported by National Research Foundation of Republic of Korea (Grant No. 2011-0008976)
文摘Given a system of vector fields on a smooth manifold that spans a plane field of constant rank, we present a systematic method and an algorithm to find submanifolds that are invariant under the flows of the vector fields. We present examples of partition into invariant submanifolds, which further gives partition into orbits. We use the method of generalized Frobenius theorem by means of exterior differential systems.