This paper aims to conduct a study of the problems associated with the wear of the needles and fuel injection nozzles utilized in diesel engines. The wear found on the needles is mainly associated to impurities in the...This paper aims to conduct a study of the problems associated with the wear of the needles and fuel injection nozzles utilized in diesel engines. The wear found on the needles is mainly associated to impurities in the fuel oil and microcavitation occurred due to high pressure in the phase of the air compression for combustion of the combustible fluid. These pressures associated with the temperature and the fluid velocity results in the occurrence of vaporization, which releases shock waves that cause damage to the affected surface. The impurities solid particles from the fuel oil cause problems inside the nozzles as obstruction of the holes and wear on the needle tip and nozzle seat surface. These failures affect in the atomization of the fuel, since the deterioration of the internal passages of the nozzles interferes in the spray formation and in the end passage of the fluid. For the execution of this study it will be used digital microscopic analysis in specimens that suffered damage, in order to investigate the effects of fuel property, and the temperature conditions and pressure in the formation of the wear on the needles and injector nozzle.展开更多
In order to investigate the effect of transient needle opening on early stage of spray behavior, simultaneous measurements of velocity and size of droplet were conducted by a newly developed laser 2-focus velocimeter ...In order to investigate the effect of transient needle opening on early stage of spray behavior, simultaneous measurements of velocity and size of droplet were conducted by a newly developed laser 2-focus velocimeter (L2F). The micro-scale probe of the L2F was consisted of two foci with a distance of 36μm. The tested nozzle had a single hole with a diameter of 0.2 mm. The measurements of injection pressure, needle lift, and crank angle were synchronized with the spray measurement by the L2F at the position 10 mm downstream from the nozzle exit. It has been clearly shown that the velocity and size of droplet increase with needle valve opening and that the probability density distribution of droplet size can be fitted to the Nukiyama-Tanasawa distribution under the transient needle opening condition.展开更多
文摘This paper aims to conduct a study of the problems associated with the wear of the needles and fuel injection nozzles utilized in diesel engines. The wear found on the needles is mainly associated to impurities in the fuel oil and microcavitation occurred due to high pressure in the phase of the air compression for combustion of the combustible fluid. These pressures associated with the temperature and the fluid velocity results in the occurrence of vaporization, which releases shock waves that cause damage to the affected surface. The impurities solid particles from the fuel oil cause problems inside the nozzles as obstruction of the holes and wear on the needle tip and nozzle seat surface. These failures affect in the atomization of the fuel, since the deterioration of the internal passages of the nozzles interferes in the spray formation and in the end passage of the fluid. For the execution of this study it will be used digital microscopic analysis in specimens that suffered damage, in order to investigate the effects of fuel property, and the temperature conditions and pressure in the formation of the wear on the needles and injector nozzle.
文摘In order to investigate the effect of transient needle opening on early stage of spray behavior, simultaneous measurements of velocity and size of droplet were conducted by a newly developed laser 2-focus velocimeter (L2F). The micro-scale probe of the L2F was consisted of two foci with a distance of 36μm. The tested nozzle had a single hole with a diameter of 0.2 mm. The measurements of injection pressure, needle lift, and crank angle were synchronized with the spray measurement by the L2F at the position 10 mm downstream from the nozzle exit. It has been clearly shown that the velocity and size of droplet increase with needle valve opening and that the probability density distribution of droplet size can be fitted to the Nukiyama-Tanasawa distribution under the transient needle opening condition.