期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
棉纺纱锭与织机配备的理论计算
1
作者 吴关臣 《天津工业大学学报》 CAS 北大核心 1991年第4期38-44,共7页
本文通过公式推导,从理论上定量地给出了细纱纱锭与织机的匹配。文中通过这方面的探讨与推导,导出了不同品种的织物、不同型号的织机台数与细纱锭数的理论匹配公式。
关键词 纱锭 织机 标准单产
下载PDF
Novel biosensor-based microarray assay for detecting rs8099917 and rs12979860 genotypes 被引量:2
2
作者 Pei-Yuan Li Xiao-Jun Zhou +3 位作者 Lan Yao Xin-Hua Fang Jiang-Nan Ren Jia-Wu Song 《World Journal of Gastroenterology》 SCIE CAS CSCD 2012年第44期6481-6488,共8页
AIM:To evaluate a novel biosensor-based microarray(BBM) assay for detecting rs12979860 and rs8099917 genotypes.METHODS:Four probes specific for rs8099917C/T or rs12979860G/T detection and three sets of quality control... AIM:To evaluate a novel biosensor-based microarray(BBM) assay for detecting rs12979860 and rs8099917 genotypes.METHODS:Four probes specific for rs8099917C/T or rs12979860G/T detection and three sets of quality control probes were designed,constructed and arrayed on an optical biosensor to develop a microarray assay.Two sets of primers were used in a one tube polymerase chain reaction(PCR) system to amplify two target fragments simultaneously.The biosensor microarray contained probes that had been sequenced to confirm that they included the rs8099917C/T or rs12979860G/T alleles of interest and could serve as the specific assay standards.In addition to rehybridization of four probes of known sequence,a total of 40 clinical samples collected from hepatitis C seropositive patients were also tested.The target fragments of all 40 samples were amplified in a 50 μL PCR system.Ten μL of each amplicon was tested by BBM assay,and another 40 μL was used for sequencing.The agreement of the results obtained by the two methods was tested statistically using the kappa coefficient.The sensitivity of the BBM assay was evaluated using serial dilutions of ten clinical blood samples containing 10 3-10 4 white cells/μL.RESULTS:As shown by polyacrylamide gel electrophoresis,two target segments of the interleukin 28Bassociated polymorphisms(SNPs) were successfully amplified in the one-tube PCR system.The lengths of the two amplified fragments were consistent with the known length of the target sequences,137 and 159 bps.After hybridization of the PCR amplicons with the probes located on the BBM array,the signals of each allele of both the rs8099917 SNPs and rs12979860 SNPs were observed simultaneously and were clearly visible by the unaided eye.The signals were distinct from each other,could be interpreted visually,and accurately recorded using an ordinary digital camera.To evaluate the specificity of the assay,both the plasmids and clinical samples were applied to the microarray.First,30 PCR amplicons of the various SNP alleles were hybridized on the BBM microarray.Full agreement between plasmids and the BBM assay was observed,with 30/30 correct matches(100%).The kappa value for the BBM assay with plasmids was 1.00(P < 0.05).For the 40 clinical blood samples,the BBM assay hybridization and direct sequencing results were compared for each amplicon.For patient blood samples,agreement was 28/28 for rs8099917T/T,9/11 for rs8099917T/G,1/1 for rs8099917G/G,24/24 for rs12979860C/C,11/14 for rs12979860C/T,and 2/2 for rs12979860T/T.Only five clinical samples of amplicon assay and direct sequencing results were discordant and heterozygotes:2/11 rs8099917T/G and 3/14 rs12979860C/T.The agreement of outcomes between BBM assay and direct sequencing for the detection of rs8099917 and rs12979860 was 95% and 92.5%,respectively;and the corresponding kappa values were 0.88 and 0.85(A kappa value > 0.75 was defined as substantial agreement).The BBM assay and sequencing had similar specificities for detection and identification of the two SNPs and their alleles.The sensitivity evaluation showed that the BBM assay could detect and identify SNP sequences present in blood samples containing as few as 10 2 white blood cells/μL.CONCLUSION:This biosensor microarray assay was highly specific,sensitive,rapid and easy to perform.It is compatible with clinical practice for detection of rs8099917 and rs12979860. 展开更多
关键词 Biosensor-based microarray Hepatitis C vi-rus rs8099917 rs12979860 Detection ASSAY
下载PDF
Liquid Crystal-Based Hydrophone Arrays
3
作者 Zourab BRODZEL Leonardo SILVESTRI +5 位作者 Andrew MICHIE Vladimir G. CHIGRINOV Qi GUO Eugene R POZHIDAEV Alexei D. KISELEV Francois LADOUCEUR 《Photonic Sensors》 SCIE EI CAS 2012年第3期237-246,共10页
We describe a fiber optic hydrophone array system that could be used for underwater acoustic surveillance applications (e.g. military, counter terrorist, and customs authorities in protecting ports and harbors), off... We describe a fiber optic hydrophone array system that could be used for underwater acoustic surveillance applications (e.g. military, counter terrorist, and customs authorities in protecting ports and harbors), offshore production facilities or coastal approaches as well as various marine applications. In this paper, we propose a new approach to underwater sonar systems using the voltage-controlled liquid crystals and simple multiplexing method. The proposed method permits measurement of sound under water at multiple points along an optical fiber using the low cost components and standard single mode fiber, without complex interferometric measurement techniques, electronics or demodulation software. 展开更多
关键词 Ferroelectric liquid crystal electrooptic response HYDROPHONE SONAR deformed helix ferroelectricliquid crystal fiber Bragg grating
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部