The objective of this investigation was to study whether it is possible to determine the air tightness of covered slurry storage tanks using tracer gas technique by injection of sulphur hexafluoride (SF6) and measur...The objective of this investigation was to study whether it is possible to determine the air tightness of covered slurry storage tanks using tracer gas technique by injection of sulphur hexafluoride (SF6) and measurements of the decay in gas concentrations with an infrared spectrophotometer in the air space above the slurry. By measuring the decay in concentration of injected tracer gas at different occasions, the air exchange rate was determined. Three different types of coverings were studied namely; wooden roof, plastic tent and concrete roof.展开更多
Indoor CO2 concentration depends on the number of persons, their metabolic rates, other sources of indoor pollution, ventilation rate and ventilation efficiency. These factors are not considered by the Spanish technic...Indoor CO2 concentration depends on the number of persons, their metabolic rates, other sources of indoor pollution, ventilation rate and ventilation efficiency. These factors are not considered by the Spanish technical building code since ventilation is set only by a fixed air change rate. This paper aims to explore the possibilities of DCVS (demand controlled ventilation systems) to ensure adequate and sustainable ventilation. It is based on a research project carried out by the University of the Basque Country (EHU-UPV) and Euskadi Public Housing and Soil Join-Stock Company (VISESA): the living rooms of 90 dwellings were provided with DCVS, where CO2 sensors were used to dynamically control the ventilation rate. Tests were carried out using tracer gas techniques, with results showing the air age to be adequate at every point of the occupied zones and free of stagnant areas, therefore proving the system's effectiveness and rapid response, and its energy savings.展开更多
文摘The objective of this investigation was to study whether it is possible to determine the air tightness of covered slurry storage tanks using tracer gas technique by injection of sulphur hexafluoride (SF6) and measurements of the decay in gas concentrations with an infrared spectrophotometer in the air space above the slurry. By measuring the decay in concentration of injected tracer gas at different occasions, the air exchange rate was determined. Three different types of coverings were studied namely; wooden roof, plastic tent and concrete roof.
文摘Indoor CO2 concentration depends on the number of persons, their metabolic rates, other sources of indoor pollution, ventilation rate and ventilation efficiency. These factors are not considered by the Spanish technical building code since ventilation is set only by a fixed air change rate. This paper aims to explore the possibilities of DCVS (demand controlled ventilation systems) to ensure adequate and sustainable ventilation. It is based on a research project carried out by the University of the Basque Country (EHU-UPV) and Euskadi Public Housing and Soil Join-Stock Company (VISESA): the living rooms of 90 dwellings were provided with DCVS, where CO2 sensors were used to dynamically control the ventilation rate. Tests were carried out using tracer gas techniques, with results showing the air age to be adequate at every point of the occupied zones and free of stagnant areas, therefore proving the system's effectiveness and rapid response, and its energy savings.