Improvement of the heat transfer effect of cold side of a thermoelectric generator(TEG) is one of the approaches to enhance the performance of the TEG systems.As a new type of heat transfer media,nanofluids can enhanc...Improvement of the heat transfer effect of cold side of a thermoelectric generator(TEG) is one of the approaches to enhance the performance of the TEG systems.As a new type of heat transfer media,nanofluids can enhance the heat transfer performance of working liquid significantly.In this study,the performance of a commercial TEG with graphene-water(GW) nanofluid as coolants in a minichannel heat exchanger is investigated experimentally at low temperatures.The results show that the output power of TEG increases with the flow rate under 950 mL/min.However,the fluid flow rate has no influence on the output power of TEG with higher flow rate(larger than 950 mL/min) when the heat transfer dynamic balance state of the system is reached.The optimal concentration and flow rate of nanofluid are 0.1 wt%and 950 mL/min,respectively.At the optimal conditions,the improved voltage,output power and conversion efficiency with GW nanofluid applied in the cooling system are increased by11.29%,21.55%and 3.5%in comparison with those with only water applied,respectively.展开更多
Based on organic Rankine cycle(ORC), the two-stage evaporation strategy is adopted to replace the single-stage evaporation to improve the system performance. In order to evaluate the temperature matching of the two-st...Based on organic Rankine cycle(ORC), the two-stage evaporation strategy is adopted to replace the single-stage evaporation to improve the system performance. In order to evaluate the temperature matching of the two-stage evaporation, a theoretical optimization model was established to optimize the two stage organic Rankine cycle(TSORC) based on the entransy theory and thermodynamics, with the ratio of the entransy dissipation rate of the TSORC to that of the ORC as the objective function. This paper aims to illuminate the improving degree of the system performance of the TSORC. The results show that the TSORC enhances the average evaporating temperature, thereby reducing the entransy dissipation rate in the evaporator and the total entransy dissipation rate. The maximal net power output is proportional to the entransy loss rate and inversely proportional to the entransy dissipation rate. However, compared with the ORC, the TSORC can output more power but requires a higher total thermal conductance. Moreover, there exists an optimal intermediate geothermal water temperature(IGWT) to maximize the net power output of the TSORC. The TSORC can be considered in engineering applications.展开更多
基金supported by the National Natural Science Foundation of China(Grant Nos.51590902&51476095)the Natural Science Foundation of Shanghai(Grant No.14ZR1417000)+1 种基金the Key Subject of Shanghai Polytechnic University(Material Science and Engineering,Grant No.XXKZD1601)the Program for Professor of Special Appointment(Young Eastern Scholar,Grant No.QD2015052)at Shanghai Institutions of Higher Learning
文摘Improvement of the heat transfer effect of cold side of a thermoelectric generator(TEG) is one of the approaches to enhance the performance of the TEG systems.As a new type of heat transfer media,nanofluids can enhance the heat transfer performance of working liquid significantly.In this study,the performance of a commercial TEG with graphene-water(GW) nanofluid as coolants in a minichannel heat exchanger is investigated experimentally at low temperatures.The results show that the output power of TEG increases with the flow rate under 950 mL/min.However,the fluid flow rate has no influence on the output power of TEG with higher flow rate(larger than 950 mL/min) when the heat transfer dynamic balance state of the system is reached.The optimal concentration and flow rate of nanofluid are 0.1 wt%and 950 mL/min,respectively.At the optimal conditions,the improved voltage,output power and conversion efficiency with GW nanofluid applied in the cooling system are increased by11.29%,21.55%and 3.5%in comparison with those with only water applied,respectively.
基金supported by the National Natural Science Foundation of China(Grant No.51406130)
文摘Based on organic Rankine cycle(ORC), the two-stage evaporation strategy is adopted to replace the single-stage evaporation to improve the system performance. In order to evaluate the temperature matching of the two-stage evaporation, a theoretical optimization model was established to optimize the two stage organic Rankine cycle(TSORC) based on the entransy theory and thermodynamics, with the ratio of the entransy dissipation rate of the TSORC to that of the ORC as the objective function. This paper aims to illuminate the improving degree of the system performance of the TSORC. The results show that the TSORC enhances the average evaporating temperature, thereby reducing the entransy dissipation rate in the evaporator and the total entransy dissipation rate. The maximal net power output is proportional to the entransy loss rate and inversely proportional to the entransy dissipation rate. However, compared with the ORC, the TSORC can output more power but requires a higher total thermal conductance. Moreover, there exists an optimal intermediate geothermal water temperature(IGWT) to maximize the net power output of the TSORC. The TSORC can be considered in engineering applications.