This paper mainly is study on power system working state with neutral point different grounded methods, when the power system is normal working and the single-phase grounding. And further analysis of the different ope...This paper mainly is study on power system working state with neutral point different grounded methods, when the power system is normal working and the single-phase grounding. And further analysis of the different operating modes of voltage and current relationships, expounds the different operation occasions and characteristics.展开更多
There are three well known types of wire lines for transmitting electrical energy or information. The first type is ordinary two wires line (below A-Line). The second type is so-called single-wire line, where ground...There are three well known types of wire lines for transmitting electrical energy or information. The first type is ordinary two wires line (below A-Line). The second type is so-called single-wire line, where ground plays the role instead of second wire. Polyphase systems belong to the third type, three phase system is the most popular among them. The purpose of this article is another attempt to build a one-wired (without ground) system--the transmission of electrical energy. In this paper an original idea of building such a system is justified, the results of simulations and laboratory modeling are presented. It is shown that the proposed method can reduce the cost of electric transmission lines, the losses in them and significantly reduce interferences.展开更多
This paper presents the development of a new technique to monitor the operating conditions of a grounding device of high voltage apparatus and systems without any diggings and forced outages. The model is based on the...This paper presents the development of a new technique to monitor the operating conditions of a grounding device of high voltage apparatus and systems without any diggings and forced outages. The model is based on the evaluation of the magnetic field distribution along the current-carrying horizontal element when it has been deteriorated or broken. A mathematical model which can be used to analyze and evaluate the integrity of the grounding device has been developed. Computer simulation studies were conducted to validate the effectiveness of the proposed model.展开更多
文摘This paper mainly is study on power system working state with neutral point different grounded methods, when the power system is normal working and the single-phase grounding. And further analysis of the different operating modes of voltage and current relationships, expounds the different operation occasions and characteristics.
文摘There are three well known types of wire lines for transmitting electrical energy or information. The first type is ordinary two wires line (below A-Line). The second type is so-called single-wire line, where ground plays the role instead of second wire. Polyphase systems belong to the third type, three phase system is the most popular among them. The purpose of this article is another attempt to build a one-wired (without ground) system--the transmission of electrical energy. In this paper an original idea of building such a system is justified, the results of simulations and laboratory modeling are presented. It is shown that the proposed method can reduce the cost of electric transmission lines, the losses in them and significantly reduce interferences.
文摘This paper presents the development of a new technique to monitor the operating conditions of a grounding device of high voltage apparatus and systems without any diggings and forced outages. The model is based on the evaluation of the magnetic field distribution along the current-carrying horizontal element when it has been deteriorated or broken. A mathematical model which can be used to analyze and evaluate the integrity of the grounding device has been developed. Computer simulation studies were conducted to validate the effectiveness of the proposed model.