期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
规范农电工行为的“十条红线”
1
作者 王广跃 蒋桂强 《农村电工》 2002年第12期14-14,共1页
关键词 电工行为 供电企业 电价 规范化管理
下载PDF
High temperature plastic deformation behavior of non-oriented electrical steel 被引量:1
2
作者 肖于德 李敏 +3 位作者 王伟 周娟 吴光亮 彭跃明 《Journal of Central South University》 SCIE EI CAS 2009年第1期25-31,共7页
High temperature plastic deformation behavior of non-orientated electrical steel was investigated by Gleeble 1500 thermo-mechanical simulator at strain rate of 0.01-10 s^-1 and high temperature of 500-1 200 ℃. The st... High temperature plastic deformation behavior of non-orientated electrical steel was investigated by Gleeble 1500 thermo-mechanical simulator at strain rate of 0.01-10 s^-1 and high temperature of 500-1 200 ℃. The stress level factor (a), stress exponent (n), structural factor (A) and activation energy (Q) of high temperature plastic deformation process of non-orientated electrical steel in different temperature ranges were calculated by the Arrhenius model. The results show that, with dynamic elevation of deformation temperature, phase transformation from α-Fe to γ-Fe takes place simultaneously during plastic deformation, dynamic recovery and dynamic recrystallization process, leading to an irregular change of the steady flow stress. For high temperature plastic deformation between 500 and 800 ℃, the calculated values of a, n, A, and Q are 0.039 0 MPa 1, 7.93, 1.9× 10^18 s^-1, and 334.8 kJ/mol, respectively, and for high temperature plastic deformation between 1 050 and 1 200 ℃, the calculated values of a, n, A, and Q are 0.125 8 MPa1, 5.29, 1.0 × 10^28 s^-1, and 769.9 kJ/mol, respectively. 展开更多
关键词 non-oriented electrical steel plastic deformation flow stress
下载PDF
Treatment of mine drainage generated by lead-zinc concentration plant
3
作者 曾科 覃文庆 +2 位作者 焦芬 何名飞 孔令强 《Journal of Central South University》 SCIE EI CAS 2014年第4期1453-1460,共8页
The purification efficiency in the treatment of the mine drainage generated by the mineral processing industry in Mengzi,Yunnan Project, China, was investigated, and the influences of the treated drainage on the miner... The purification efficiency in the treatment of the mine drainage generated by the mineral processing industry in Mengzi,Yunnan Project, China, was investigated, and the influences of the treated drainage on the mineral electrodes' electrochemical behaviors were tested. Experiments with different doses of polyacrylamide(PAM) and polymeric ferric sulfate(PFS) at different pH values were carried out, and the advanced purification by activated carbon(AC) was conducted. Compared with PFS, the better coagulant for removal efficiency is PAM, under the optimal conditions, the removals of Pb2+, Zn2+, Cu2+ and COD reduction from solution were 94.8%, 79.9%, 87.6% and 85%, respectively. In the advanced purification, the particle size of activated carbon and agitation time played important roles in the removal efficiency. Each pollute concentration could meet the emission standard of pollutants for lead and zinc industry(GB25466—2010). The wastewater without treatment affected galena and sphalerite electrochemical behaviors greatly, after treatment by the technology, the effects disappeared, which proved the reliability of the technology for wastewater treatment. 展开更多
关键词 heavy metal removal mine drainage coagulation-flocculation corrosive electrochemistry
下载PDF
Corrosion behavior of 907 steel under thin electrolyte layers of artificial seawater 被引量:5
4
作者 王慧萍 丁少春 +3 位作者 朱娟 张昭 张鉴清 曹楚南 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第3期806-814,共9页
The corrosion behavior of 907 steel under thin electrolyte layer(TEL) has been investigated by means of cathodic polarization curve measurement, electrochemical impedance spectroscopy(EIS) and scanning electron micros... The corrosion behavior of 907 steel under thin electrolyte layer(TEL) has been investigated by means of cathodic polarization curve measurement, electrochemical impedance spectroscopy(EIS) and scanning electron microscopy(SEM). The results show that the cathodic diffusion current density presents the variation trend of initial increase and subsequent decrease with the decrease of TEL thickness, and the maximum deposits at 58 μm. The cotangent-hyperbolic impedance(O) is rationally first introduced to study the diffusion process of the reactants through the corrosion products layer with many permeable holes. The initial corrosion rate of 907 steel under different TEL thickness increases with the decrease of TEL thickness except that of 104 μm,whereas the corrosion rate after long time corrosion can be ranked as 104 μm﹥402 μm﹥198 μm﹥301 μm﹥bulk solution. 展开更多
关键词 907 steel atmospheric corrosion electrochemical impedance spectroscopy polarization
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部