High temperature plastic deformation behavior of non-orientated electrical steel was investigated by Gleeble 1500 thermo-mechanical simulator at strain rate of 0.01-10 s^-1 and high temperature of 500-1 200 ℃. The st...High temperature plastic deformation behavior of non-orientated electrical steel was investigated by Gleeble 1500 thermo-mechanical simulator at strain rate of 0.01-10 s^-1 and high temperature of 500-1 200 ℃. The stress level factor (a), stress exponent (n), structural factor (A) and activation energy (Q) of high temperature plastic deformation process of non-orientated electrical steel in different temperature ranges were calculated by the Arrhenius model. The results show that, with dynamic elevation of deformation temperature, phase transformation from α-Fe to γ-Fe takes place simultaneously during plastic deformation, dynamic recovery and dynamic recrystallization process, leading to an irregular change of the steady flow stress. For high temperature plastic deformation between 500 and 800 ℃, the calculated values of a, n, A, and Q are 0.039 0 MPa 1, 7.93, 1.9× 10^18 s^-1, and 334.8 kJ/mol, respectively, and for high temperature plastic deformation between 1 050 and 1 200 ℃, the calculated values of a, n, A, and Q are 0.125 8 MPa1, 5.29, 1.0 × 10^28 s^-1, and 769.9 kJ/mol, respectively.展开更多
The purification efficiency in the treatment of the mine drainage generated by the mineral processing industry in Mengzi,Yunnan Project, China, was investigated, and the influences of the treated drainage on the miner...The purification efficiency in the treatment of the mine drainage generated by the mineral processing industry in Mengzi,Yunnan Project, China, was investigated, and the influences of the treated drainage on the mineral electrodes' electrochemical behaviors were tested. Experiments with different doses of polyacrylamide(PAM) and polymeric ferric sulfate(PFS) at different pH values were carried out, and the advanced purification by activated carbon(AC) was conducted. Compared with PFS, the better coagulant for removal efficiency is PAM, under the optimal conditions, the removals of Pb2+, Zn2+, Cu2+ and COD reduction from solution were 94.8%, 79.9%, 87.6% and 85%, respectively. In the advanced purification, the particle size of activated carbon and agitation time played important roles in the removal efficiency. Each pollute concentration could meet the emission standard of pollutants for lead and zinc industry(GB25466—2010). The wastewater without treatment affected galena and sphalerite electrochemical behaviors greatly, after treatment by the technology, the effects disappeared, which proved the reliability of the technology for wastewater treatment.展开更多
The corrosion behavior of 907 steel under thin electrolyte layer(TEL) has been investigated by means of cathodic polarization curve measurement, electrochemical impedance spectroscopy(EIS) and scanning electron micros...The corrosion behavior of 907 steel under thin electrolyte layer(TEL) has been investigated by means of cathodic polarization curve measurement, electrochemical impedance spectroscopy(EIS) and scanning electron microscopy(SEM). The results show that the cathodic diffusion current density presents the variation trend of initial increase and subsequent decrease with the decrease of TEL thickness, and the maximum deposits at 58 μm. The cotangent-hyperbolic impedance(O) is rationally first introduced to study the diffusion process of the reactants through the corrosion products layer with many permeable holes. The initial corrosion rate of 907 steel under different TEL thickness increases with the decrease of TEL thickness except that of 104 μm,whereas the corrosion rate after long time corrosion can be ranked as 104 μm﹥402 μm﹥198 μm﹥301 μm﹥bulk solution.展开更多
基金Project(2005038560) supported by the Postdoctoral Foundation of ChinaProject(05GK1002-2) supported by Key Program of Hunan Province
文摘High temperature plastic deformation behavior of non-orientated electrical steel was investigated by Gleeble 1500 thermo-mechanical simulator at strain rate of 0.01-10 s^-1 and high temperature of 500-1 200 ℃. The stress level factor (a), stress exponent (n), structural factor (A) and activation energy (Q) of high temperature plastic deformation process of non-orientated electrical steel in different temperature ranges were calculated by the Arrhenius model. The results show that, with dynamic elevation of deformation temperature, phase transformation from α-Fe to γ-Fe takes place simultaneously during plastic deformation, dynamic recovery and dynamic recrystallization process, leading to an irregular change of the steady flow stress. For high temperature plastic deformation between 500 and 800 ℃, the calculated values of a, n, A, and Q are 0.039 0 MPa 1, 7.93, 1.9× 10^18 s^-1, and 334.8 kJ/mol, respectively, and for high temperature plastic deformation between 1 050 and 1 200 ℃, the calculated values of a, n, A, and Q are 0.125 8 MPa1, 5.29, 1.0 × 10^28 s^-1, and 769.9 kJ/mol, respectively.
基金Project(2010CB630905)supported by the National Basic Research Program of China
文摘The purification efficiency in the treatment of the mine drainage generated by the mineral processing industry in Mengzi,Yunnan Project, China, was investigated, and the influences of the treated drainage on the mineral electrodes' electrochemical behaviors were tested. Experiments with different doses of polyacrylamide(PAM) and polymeric ferric sulfate(PFS) at different pH values were carried out, and the advanced purification by activated carbon(AC) was conducted. Compared with PFS, the better coagulant for removal efficiency is PAM, under the optimal conditions, the removals of Pb2+, Zn2+, Cu2+ and COD reduction from solution were 94.8%, 79.9%, 87.6% and 85%, respectively. In the advanced purification, the particle size of activated carbon and agitation time played important roles in the removal efficiency. Each pollute concentration could meet the emission standard of pollutants for lead and zinc industry(GB25466—2010). The wastewater without treatment affected galena and sphalerite electrochemical behaviors greatly, after treatment by the technology, the effects disappeared, which proved the reliability of the technology for wastewater treatment.
基金Projects(21073162,21273199) supported by the National Natural Science Foundation of ChinaProject(GCTKF2012013) supported by the Science and Technology Bureau of Jiaxing Municipality and the State Key Laboratory Breeding Base of Green Chemistry-Synthesis Technology,China
文摘The corrosion behavior of 907 steel under thin electrolyte layer(TEL) has been investigated by means of cathodic polarization curve measurement, electrochemical impedance spectroscopy(EIS) and scanning electron microscopy(SEM). The results show that the cathodic diffusion current density presents the variation trend of initial increase and subsequent decrease with the decrease of TEL thickness, and the maximum deposits at 58 μm. The cotangent-hyperbolic impedance(O) is rationally first introduced to study the diffusion process of the reactants through the corrosion products layer with many permeable holes. The initial corrosion rate of 907 steel under different TEL thickness increases with the decrease of TEL thickness except that of 104 μm,whereas the corrosion rate after long time corrosion can be ranked as 104 μm﹥402 μm﹥198 μm﹥301 μm﹥bulk solution.