在管理科学范畴中.美国工程师泰勒及贝尔电话实验室休哈特等人的质量管理科学理论功不可没。在休啥特的过程控制理论(这比自动化技术中所指的过程控制含义更广)中形成了SPC(Statistical Process Control.统计过程控制).其中有了σ(...在管理科学范畴中.美国工程师泰勒及贝尔电话实验室休哈特等人的质量管理科学理论功不可没。在休啥特的过程控制理论(这比自动化技术中所指的过程控制含义更广)中形成了SPC(Statistical Process Control.统计过程控制).其中有了σ(西格玛.为过程变异标准偏差)的概念。展开更多
A new method of measuring gas pressure in vacuum insulation panels(VIPs)is reported in this study,which provides a fast and efficient quality control option of production.Although there are different methods of measur...A new method of measuring gas pressure in vacuum insulation panels(VIPs)is reported in this study,which provides a fast and efficient quality control option of production.Although there are different methods of measuring gas pressure for VIPs,connecting an internal measurement gauge to external data acquisition units is problematic.The thin high barrier film covering the panel’s core usually prevents external electrical wires or mechanical devices being connected to the inside of the VIPs.To solve this problem,a micro capacitive pressure sensor with 0 to 250 Pa detection range is developed to detect the vacuum pressure.The sensor has high linearity and a sensitivity of 10 mV/Pa.Moreover,through the communication mode study,an ultrasound communications system for VIPs is designed.It shows from operation that this system is stable and reliable,and quick for communication speed.This new method enables the quality detection of VIPs to be completed within 1 second.The minimum detectable pressure of VIPs is below 1 Pa,and the measurement error can be controlled around 5%.展开更多
基金supported by the Science and Technology Projects of Fujian Province of China(Grant No.2010H6025)Science and Technology Projects of Xiamen City of China(Grant No.3502Z20103012)
文摘A new method of measuring gas pressure in vacuum insulation panels(VIPs)is reported in this study,which provides a fast and efficient quality control option of production.Although there are different methods of measuring gas pressure for VIPs,connecting an internal measurement gauge to external data acquisition units is problematic.The thin high barrier film covering the panel’s core usually prevents external electrical wires or mechanical devices being connected to the inside of the VIPs.To solve this problem,a micro capacitive pressure sensor with 0 to 250 Pa detection range is developed to detect the vacuum pressure.The sensor has high linearity and a sensitivity of 10 mV/Pa.Moreover,through the communication mode study,an ultrasound communications system for VIPs is designed.It shows from operation that this system is stable and reliable,and quick for communication speed.This new method enables the quality detection of VIPs to be completed within 1 second.The minimum detectable pressure of VIPs is below 1 Pa,and the measurement error can be controlled around 5%.