Ultrasound has been widely used in clinics. Cellular responses to low-intensity ultrasound are parameter-dependent. Proper parameter setting is vital to its exact use. To get guidelines for parameter setting, lowinten...Ultrasound has been widely used in clinics. Cellular responses to low-intensity ultrasound are parameter-dependent. Proper parameter setting is vital to its exact use. To get guidelines for parameter setting, lowintensity ultrasound stimulation on the proliferation and reproductivity of Hep G2 and 3T3 cells in vitro was examined with a 1.06 MHz-generator by changing the parameters(including intensity, pulse repetition frequency and duty cycle)in a wide range. Cell viability and reproductivity at different time after sonication were measured by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide(MTT)and colony formation assay to indicate timerelated proliferation. The results illustrate that ultrasound irradiation at 0.4—0.8 W/cm^2 and high pulse repetition frequency(100 Hz)can facilitate cell proliferation, while above 0.8 W/cm^2 would resist it. The extent of resistance closely correlated with duty cycle and pulse repetition frequency. Resistance effect at low pulse repetition frequency(1 Hz)is greater than that at high pulse repetition frequency(100 Hz)and not time-related. The influence of high pulse repetition frequency is time-accumulated, indicating cellular process involved. These findings would provide valuable guidelines for the application of low-intensity ultrasound in stem cell transformation and tissue engineering.展开更多
Let Sdp be the p-multiple time set of the Brownian motion in d dimensions. In this paper , the Hausdorff measure function for S32 is proved to be , and the Hausdorff measuure problem for S2p is also discussed. As a re...Let Sdp be the p-multiple time set of the Brownian motion in d dimensions. In this paper , the Hausdorff measure function for S32 is proved to be , and the Hausdorff measuure problem for S2p is also discussed. As a result, a conjecture suggested by J. Rosen is partially proved.展开更多
基金Supported by the Natural Science Foundation of Tianjin(No.12JCYBJC18300)
文摘Ultrasound has been widely used in clinics. Cellular responses to low-intensity ultrasound are parameter-dependent. Proper parameter setting is vital to its exact use. To get guidelines for parameter setting, lowintensity ultrasound stimulation on the proliferation and reproductivity of Hep G2 and 3T3 cells in vitro was examined with a 1.06 MHz-generator by changing the parameters(including intensity, pulse repetition frequency and duty cycle)in a wide range. Cell viability and reproductivity at different time after sonication were measured by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide(MTT)and colony formation assay to indicate timerelated proliferation. The results illustrate that ultrasound irradiation at 0.4—0.8 W/cm^2 and high pulse repetition frequency(100 Hz)can facilitate cell proliferation, while above 0.8 W/cm^2 would resist it. The extent of resistance closely correlated with duty cycle and pulse repetition frequency. Resistance effect at low pulse repetition frequency(1 Hz)is greater than that at high pulse repetition frequency(100 Hz)and not time-related. The influence of high pulse repetition frequency is time-accumulated, indicating cellular process involved. These findings would provide valuable guidelines for the application of low-intensity ultrasound in stem cell transformation and tissue engineering.
文摘Let Sdp be the p-multiple time set of the Brownian motion in d dimensions. In this paper , the Hausdorff measure function for S32 is proved to be , and the Hausdorff measuure problem for S2p is also discussed. As a result, a conjecture suggested by J. Rosen is partially proved.