Coal washing plants are usually fed from various sources. Coals include different combinations which should be considered for increasing the plant proficiency. Thus different methods have been used to enrich various c...Coal washing plants are usually fed from various sources. Coals include different combinations which should be considered for increasing the plant proficiency. Thus different methods have been used to enrich various coal types. In this study, Alborz-Sharghi coal washing plant was investigated which is fed from five coalmines. The optimum recovery was achieved for all coal types individually through experimental design. The controllable operation parameters in the experiments were collector dosage,frother dosage, solid percent content and particle size. The other parameters such as impeller speed,pH, conditioning time and flotation time were kept constant for all experiments. The optimum combination of coals was also specified. The results show that the optimum recovery for coal blends is 91.2%which shows much improvement relative to the plant conditions.展开更多
The results of the assessment of the influence of paper insulation on the discharge initiation in oil were presented in this paper. This assessment based on the results of performed experimental works and on the analy...The results of the assessment of the influence of paper insulation on the discharge initiation in oil were presented in this paper. This assessment based on the results of performed experimental works and on the analysis of electrical field distribution. Both types of the studies were connected with the model HV (high voltage) electrode setups covered by paper and immersed in oil. Experimental works indicated that the source of "weak points" of paper-oil model electrode setup is oil, not the surface of metal or insulation wrapping. Such hypothesis, resulting mainly from the measured times to initiations of discharges developing from bare and insulated HV electrodes, was verified by the analysis of electrical field distribution performed on the basis of finite element method applied in the COMSOL Multiphysics software. This analysis confirmed preliminary the made hypothesis. Correlation with the most stressed oil volume law was also observed.展开更多
In this paper, a simulation model of Permanent Magnet Linear Synchronous Motor (PMLSM) is established by using phase equations method. Special attention is paid to its structure and the influence of longitudinal end e...In this paper, a simulation model of Permanent Magnet Linear Synchronous Motor (PMLSM) is established by using phase equations method. Special attention is paid to its structure and the influence of longitudinal end effect and the unbalance of current. The analytic method can be used for the analysis of dynamic and static characteristics of PMLSM.展开更多
文摘Coal washing plants are usually fed from various sources. Coals include different combinations which should be considered for increasing the plant proficiency. Thus different methods have been used to enrich various coal types. In this study, Alborz-Sharghi coal washing plant was investigated which is fed from five coalmines. The optimum recovery was achieved for all coal types individually through experimental design. The controllable operation parameters in the experiments were collector dosage,frother dosage, solid percent content and particle size. The other parameters such as impeller speed,pH, conditioning time and flotation time were kept constant for all experiments. The optimum combination of coals was also specified. The results show that the optimum recovery for coal blends is 91.2%which shows much improvement relative to the plant conditions.
文摘The results of the assessment of the influence of paper insulation on the discharge initiation in oil were presented in this paper. This assessment based on the results of performed experimental works and on the analysis of electrical field distribution. Both types of the studies were connected with the model HV (high voltage) electrode setups covered by paper and immersed in oil. Experimental works indicated that the source of "weak points" of paper-oil model electrode setup is oil, not the surface of metal or insulation wrapping. Such hypothesis, resulting mainly from the measured times to initiations of discharges developing from bare and insulated HV electrodes, was verified by the analysis of electrical field distribution performed on the basis of finite element method applied in the COMSOL Multiphysics software. This analysis confirmed preliminary the made hypothesis. Correlation with the most stressed oil volume law was also observed.
文摘In this paper, a simulation model of Permanent Magnet Linear Synchronous Motor (PMLSM) is established by using phase equations method. Special attention is paid to its structure and the influence of longitudinal end effect and the unbalance of current. The analytic method can be used for the analysis of dynamic and static characteristics of PMLSM.