Objective:To study the clinical outcomes of complete mesocolic excision(CME)for right-sided colon cancer using 3D(three-dimensional)laparoscopy compared to 2D(two-dimensional)laparoscopy.Methods:From January 2022 to D...Objective:To study the clinical outcomes of complete mesocolic excision(CME)for right-sided colon cancer using 3D(three-dimensional)laparoscopy compared to 2D(two-dimensional)laparoscopy.Methods:From January 2022 to December 2023,58 patients with right-sided colon cancer treated at the Affiliated Hospital of Hebei Engineering University were randomly divided into a 3D laparoscopy group(observation group)and a 2D laparoscopy group(control group),with 29 patients in each group.Intraoperative blood loss,postoperative time to first flatulence,length of hospital stay,and incidence of complications in both groups were recorded.Results:There was a statistically significant difference in intraoperative blood loss between the two groups(P<0.05).There was no statistically significant difference in the time to first flatulence between the groups(P>0.05).However,there was a statistically significant difference in the length of hospital stay(P<0.05)and the incidence of complications(P<0.05)between the two groups.Conclusion:3D laparoscopy for CME can reduce intraoperative blood loss,shorten hospital stay,and decrease postoperative complications,showing significant clinical advantages over traditional 2D laparoscopy.展开更多
FeS_(2)cathode is promising for all-solid-state lithium batteries due to its ultra-high capacity,low cost,and environmental friendliness.However,the poor performances,induced by limited electrode-electrolyte interface...FeS_(2)cathode is promising for all-solid-state lithium batteries due to its ultra-high capacity,low cost,and environmental friendliness.However,the poor performances,induced by limited electrode-electrolyte interface,severe volume expansion,and polysulfide shuttle,hinder the application of FeS_(2)in all-solid-state lithium batteries.Herein,an integrated 3D FeS_(2)electrode with full infiltration of Li6PS5Cl sulfide electrolytes is designed to address these challenges.Such a 3D integrated design not only achieves intimate and maximized interfacial contact between electrode and sulfide electrolytes,but also effectively buffers the inner volume change of FeS_(2)and completely eliminates the polysulfide shuttle through direct solid-solid conversion of Li2S/S.Besides,the vertical 3D arrays guarantee direct electron transport channels and horizontally shortened ion diffusion paths,endowing the integrated electrode with a remarkably reduced interfacial impedance and enhanced reaction kinetics.Benefiting from these synergies,the integrated all-solid-state lithium battery exhibits the largest reversible capacity(667 mAh g^(-1)),best rate performance,and highest capacity retention of 82%over 500 cycles at 0.1 C compared to both a liquid battery and non-integrated all-solid-state lithium battery.The cycling performance is among the best reported for FeS_(2)-based all-solid-state lithium batteries.This work presents an innovative synergistic strategy for designing long-cycling high-energy all-solid-state lithium batteries,which can be readily applied to other battery systems,such as lithium-sulfur batteries.展开更多
X-ray computed tomography(CT)has been an important technology in paleontology for several decades.It helps researchers to acquire detailed anatomical structures of fossils non-destructively.Despite its widespread appl...X-ray computed tomography(CT)has been an important technology in paleontology for several decades.It helps researchers to acquire detailed anatomical structures of fossils non-destructively.Despite its widespread application,developing an efficient and user-friendly method for segmenting CT data continues to be a formidable challenge in the field.Most CT data segmentation software operates on 2D interfaces,which limits flexibility for real-time adjustments in 3D segmentation.Here,we introduce Curves Mode in Drishti Paint 3.2,an open-source tool for CT data segmentation.Drishti Paint 3.2 allows users to manually or semi-automatically segment the CT data in both 2D and 3D environments,providing a novel solution for revisualizing CT data in paleontological studies.展开更多
文摘Objective:To study the clinical outcomes of complete mesocolic excision(CME)for right-sided colon cancer using 3D(three-dimensional)laparoscopy compared to 2D(two-dimensional)laparoscopy.Methods:From January 2022 to December 2023,58 patients with right-sided colon cancer treated at the Affiliated Hospital of Hebei Engineering University were randomly divided into a 3D laparoscopy group(observation group)and a 2D laparoscopy group(control group),with 29 patients in each group.Intraoperative blood loss,postoperative time to first flatulence,length of hospital stay,and incidence of complications in both groups were recorded.Results:There was a statistically significant difference in intraoperative blood loss between the two groups(P<0.05).There was no statistically significant difference in the time to first flatulence between the groups(P>0.05).However,there was a statistically significant difference in the length of hospital stay(P<0.05)and the incidence of complications(P<0.05)between the two groups.Conclusion:3D laparoscopy for CME can reduce intraoperative blood loss,shorten hospital stay,and decrease postoperative complications,showing significant clinical advantages over traditional 2D laparoscopy.
基金supported by the National Natural Science Foundation of China(Grant nos.52272201,52072136,52172229,52302303,and 51972257)Yanchang Petroleum-WHUT Joint Program(yc-whlg-2022ky-05)+1 种基金the State Key Laboratory of Advanced Technology for Materials Synthesis and Processing(Wuhan University of Technology,2022-KF-20)Fundamental Research Funds for the Central Universities(2023IVA106)for financial support
文摘FeS_(2)cathode is promising for all-solid-state lithium batteries due to its ultra-high capacity,low cost,and environmental friendliness.However,the poor performances,induced by limited electrode-electrolyte interface,severe volume expansion,and polysulfide shuttle,hinder the application of FeS_(2)in all-solid-state lithium batteries.Herein,an integrated 3D FeS_(2)electrode with full infiltration of Li6PS5Cl sulfide electrolytes is designed to address these challenges.Such a 3D integrated design not only achieves intimate and maximized interfacial contact between electrode and sulfide electrolytes,but also effectively buffers the inner volume change of FeS_(2)and completely eliminates the polysulfide shuttle through direct solid-solid conversion of Li2S/S.Besides,the vertical 3D arrays guarantee direct electron transport channels and horizontally shortened ion diffusion paths,endowing the integrated electrode with a remarkably reduced interfacial impedance and enhanced reaction kinetics.Benefiting from these synergies,the integrated all-solid-state lithium battery exhibits the largest reversible capacity(667 mAh g^(-1)),best rate performance,and highest capacity retention of 82%over 500 cycles at 0.1 C compared to both a liquid battery and non-integrated all-solid-state lithium battery.The cycling performance is among the best reported for FeS_(2)-based all-solid-state lithium batteries.This work presents an innovative synergistic strategy for designing long-cycling high-energy all-solid-state lithium batteries,which can be readily applied to other battery systems,such as lithium-sulfur batteries.
文摘X-ray computed tomography(CT)has been an important technology in paleontology for several decades.It helps researchers to acquire detailed anatomical structures of fossils non-destructively.Despite its widespread application,developing an efficient and user-friendly method for segmenting CT data continues to be a formidable challenge in the field.Most CT data segmentation software operates on 2D interfaces,which limits flexibility for real-time adjustments in 3D segmentation.Here,we introduce Curves Mode in Drishti Paint 3.2,an open-source tool for CT data segmentation.Drishti Paint 3.2 allows users to manually or semi-automatically segment the CT data in both 2D and 3D environments,providing a novel solution for revisualizing CT data in paleontological studies.