本文采用涂布法制备了一系列H310BO3/ZnS(Ag)闪烁体转换屏样品,对其成分配比进行了优化。结果表明,最佳的H310BO3/ZnS(Ag)质量比在1∶6~1∶7之间,最佳的黏合剂用量为总质量的25%。利用中子照相设备对转换屏的发光均匀性进行了成像分析...本文采用涂布法制备了一系列H310BO3/ZnS(Ag)闪烁体转换屏样品,对其成分配比进行了优化。结果表明,最佳的H310BO3/ZnS(Ag)质量比在1∶6~1∶7之间,最佳的黏合剂用量为总质量的25%。利用中子照相设备对转换屏的发光均匀性进行了成像分析,结果显示光输出非常均匀;对楔形镉条进行中子成像,并采用调制传递函数(modulation transfer function,MTF)方法计算了系统分辨率,结果显示,在MTF值为0.1时,对于厚度分别为270(11)、350(14)、404(9)及505(15)μm的转换屏,其相应的系统空间分辨率分别为255.6、315.9、371.0和471.3μm。展开更多
The energy-resolved neutron imaging spectrometer(ERNI)will be installed in 2022 according to the spectrometer construction plan of the China Spallation Neutron Source(CSNS).The instrument requires neutron detectors wi...The energy-resolved neutron imaging spectrometer(ERNI)will be installed in 2022 according to the spectrometer construction plan of the China Spallation Neutron Source(CSNS).The instrument requires neutron detectors with the coverage area of approximately 4 m^(2)in 5°-170°neutron diffraction angle.The neutron detection efficiency needs to be better than 40%at 1 A neutron wavelength.The spatial resolution should be better than 3 mm×50 mm in the horizontal and vertical directions respectively.We develop a one-dimensional scintillator neutron detector which is composed of the^(6)Li F/Zn S(Ag)scintillation screens,the wavelength-shifting fiber(WLSF)array,the silicon photomultipliers(Si PMs),and the self-designed application-specific integrated circuit(ASIC)readout electronics.The pixel size of the detector is designed as 3 mm×50 mm,and the neutron-sensitive area is 50 mm×200 mm.The performance of the detector prototype is measured using neutron beam 20#of the CSNS.The maximum counting rate of 247 k Hz,and the detection efficiency of63%at 1.59 A are obtained.The test results show that the performance of the detector fulfills the physical requirements of the ERNI under construction at the CSNS.展开更多
A simulation of the properties of the shifting scintillator neutron detector using 6LiF/ZnS(Ag) scintillation screens is performed.The simulation results show that the light attenuation length of standard BC704 scinti...A simulation of the properties of the shifting scintillator neutron detector using 6LiF/ZnS(Ag) scintillation screens is performed.The simulation results show that the light attenuation length of standard BC704 scintillator is about 0.65 mm.Its thermal neutron detection efficiency,gamma sensitivity and intrinsic spatial resolution can achieve around 50.0%,10 5and 0.18 mm(along X-axis) respectively.For the detector,air coupling position resolution is better than the silicone oil coupling.Some of the simulation results are compared with experimental results.They are in agreement.This work will be helpful for constructing neutron detector for high intensity powder diffractometer at Chinese spallation neutron source.展开更多
The investigation of a novel thermal neutron detector is developed to fulfill the requirements of the high intensity power diffractometer (HIPD) at the Chinese Spallation Neutron Source (CSNS). It consists of two ...The investigation of a novel thermal neutron detector is developed to fulfill the requirements of the high intensity power diffractometer (HIPD) at the Chinese Spallation Neutron Source (CSNS). It consists of two layers of 6LiF/ZnS(Ag) scintillators, two layers of crossed WLSF arrays, several multi-anode photo multiplier tubes (MA-PMT), and the matching readout electronics. The neutron detection efficiency of the scintilltors, the light transportation ability of the WLSF, and the spatial linearity of the readout electronics are measured and discussed in this paper. It shows that the sandwich structure and the compact readout electronics could fulfill the needs of the HIPD. A prototype with a 10 cm×10 cm sensitive area has been constructed to further study the characteristics of the neutron scintillator detector.展开更多
文摘本文采用涂布法制备了一系列H310BO3/ZnS(Ag)闪烁体转换屏样品,对其成分配比进行了优化。结果表明,最佳的H310BO3/ZnS(Ag)质量比在1∶6~1∶7之间,最佳的黏合剂用量为总质量的25%。利用中子照相设备对转换屏的发光均匀性进行了成像分析,结果显示光输出非常均匀;对楔形镉条进行中子成像,并采用调制传递函数(modulation transfer function,MTF)方法计算了系统分辨率,结果显示,在MTF值为0.1时,对于厚度分别为270(11)、350(14)、404(9)及505(15)μm的转换屏,其相应的系统空间分辨率分别为255.6、315.9、371.0和471.3μm。
基金the National Natural Science Foundation of China(Grant Nos.11875273,U1832111,61964001,and 12275049)the Science Foundation of Guangdong Province of China(Grant No.2020B1515120025)+3 种基金the Neutron Physics Laboratory Funding of China Academy of Engineering Physics(Grant No.2018BC03)the General Project of Jiangxi Province Key Research and Development Program(Grant No.20212BBG73012)the Key Scientific Research Projects of Henan Higher Education Institutions(Grant Nos.23A490002 and 24A490001)the Engineering Research Center of Nuclear Technology Application(Grant No.HJSJYB2021-4)。
文摘The energy-resolved neutron imaging spectrometer(ERNI)will be installed in 2022 according to the spectrometer construction plan of the China Spallation Neutron Source(CSNS).The instrument requires neutron detectors with the coverage area of approximately 4 m^(2)in 5°-170°neutron diffraction angle.The neutron detection efficiency needs to be better than 40%at 1 A neutron wavelength.The spatial resolution should be better than 3 mm×50 mm in the horizontal and vertical directions respectively.We develop a one-dimensional scintillator neutron detector which is composed of the^(6)Li F/Zn S(Ag)scintillation screens,the wavelength-shifting fiber(WLSF)array,the silicon photomultipliers(Si PMs),and the self-designed application-specific integrated circuit(ASIC)readout electronics.The pixel size of the detector is designed as 3 mm×50 mm,and the neutron-sensitive area is 50 mm×200 mm.The performance of the detector prototype is measured using neutron beam 20#of the CSNS.The maximum counting rate of 247 k Hz,and the detection efficiency of63%at 1.59 A are obtained.The test results show that the performance of the detector fulfills the physical requirements of the ERNI under construction at the CSNS.
基金supported by the National Natural Science Foundation of China(Grant No.11175257)
文摘A simulation of the properties of the shifting scintillator neutron detector using 6LiF/ZnS(Ag) scintillation screens is performed.The simulation results show that the light attenuation length of standard BC704 scintillator is about 0.65 mm.Its thermal neutron detection efficiency,gamma sensitivity and intrinsic spatial resolution can achieve around 50.0%,10 5and 0.18 mm(along X-axis) respectively.For the detector,air coupling position resolution is better than the silicone oil coupling.Some of the simulation results are compared with experimental results.They are in agreement.This work will be helpful for constructing neutron detector for high intensity powder diffractometer at Chinese spallation neutron source.
基金Supported by National Natural Science Foundation of China(11175257)Key Laboratory of Neutron Detection and Electronics of Dongguan Municipality
文摘The investigation of a novel thermal neutron detector is developed to fulfill the requirements of the high intensity power diffractometer (HIPD) at the Chinese Spallation Neutron Source (CSNS). It consists of two layers of 6LiF/ZnS(Ag) scintillators, two layers of crossed WLSF arrays, several multi-anode photo multiplier tubes (MA-PMT), and the matching readout electronics. The neutron detection efficiency of the scintilltors, the light transportation ability of the WLSF, and the spatial linearity of the readout electronics are measured and discussed in this paper. It shows that the sandwich structure and the compact readout electronics could fulfill the needs of the HIPD. A prototype with a 10 cm×10 cm sensitive area has been constructed to further study the characteristics of the neutron scintillator detector.