期刊文献+
共找到24篇文章
< 1 2 >
每页显示 20 50 100
Visual function and higher order aberration after implantation of aspheric and spherical multifocal intraocular lenses:a meta-analysis 被引量:6
1
作者 Jian-Ping Liu Fan Zhang +2 位作者 Jiang-Yue Zhao Li-Wei Ma Jin-Song Zhang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2013年第5期690-695,共6页
AIM:To assess the visual outcomes of aspheric multifocal intraocular lenses(IOLs) compared with spherical multifocal IOL after cataract surgery.METHODS:Potential prospective controlled trials that comparing aspheric m... AIM:To assess the visual outcomes of aspheric multifocal intraocular lenses(IOLs) compared with spherical multifocal IOL after cataract surgery.METHODS:Potential prospective controlled trials that comparing aspheric multifocal IOL implantation with spherical multifocal IOL group were extracted from the computer database.The statistical analysis was carried out using Stata 10 software.Standardized mean differences with 95% confidence intervals(CIs) were calculated for continuous variables.The pooled estimates were computed in the use of a random-effects model. RESULTS:A systematic review identified five prospective nonrandomized controlled trials,including 178 aspheric multifocal IOL and 164 spherical multifocal IOL.There was no significant difference in uncorrected distance visual acuity(95%CI,-0.248 to 0.152;P=0.641) and uncorrected near visual acuity(95% CI,-0.210 to 0.428;P=0.504) between aspheric multifocal IOL and spherical multifocal IOL.Statistically significant differences were detected less spherical aberration in aspheric multifocal IOL(95% CI,-1.111 to-0.472;P<0.001) when compared to spherical multifocal IOL.Spherical multifocal IOL showed a greater higher order aberration compared to the aspheric multifocal IOL(95% CI,-1.024 to-0.293;P<0.001).Sensitivity analysis suggested that the results were relatively reliable. CONCLUSION:The overall findings indicated that aspheric multifocal IOL and spherical multifocal IOL provided similar visual acuity at near and distance.Patients implanted with aspheric multifocal IOL had less spherical aberration and higher order aberration than patients with spherical multifocal IOL.Further well organized,prospective controlled trials involving larger patient numbers are needed. 展开更多
关键词 aspheric MULTIFOCAL INTRAOCULAR LENS uncorrected near visual ACUITY uncorrected distance visual ACUITY SPHERICAL MULTIFOCAL INTRAOCULAR LENS higher order ABERRATION meta-analysis
原文传递
Evaluation of visual quality of spherical and aspherical intraocular lenses by Optical Quality Analysis System 被引量:11
2
作者 Yan Chen Xue Wang +1 位作者 Chuan-Di Zhou Qiang Wu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第6期914-918,共5页
AIM: To evaluate the impact of spherical and aspherical intraocular lenses on the postoperative visual quality of age-related cataract patients using Optical Quality Analysis System(OQAS).METHODS: Seventy-four eyes wi... AIM: To evaluate the impact of spherical and aspherical intraocular lenses on the postoperative visual quality of age-related cataract patients using Optical Quality Analysis System(OQAS).METHODS: Seventy-four eyes with age-related cataracts were randomly divided into spherical and aspherical lens implantation groups. Best-corrected visual acuity(BCVA) was measured preoperatively, one day, one week, two weeks, one month and two months after surgery. A biometric systems analysis using the OQAS objective scattering index(OSI) was performed. RESULTS: There were no significant differences in visual acuity(P>0.05) before and after spherical and aspheric lens implantation. There was a negative linear correction between the OSI value and BCVA(r=-0.634, P=0.000), and positive corrections between the OSI value and the lens LOCUS III value of nucleus color(NC), nucleus opacity(NO), cortex(C) and posterior lens capsular(P)(r=0.704, P=0.000; r=0.514, P=0.000; r=0.276, P=0.020; r=0.417, P=0.000, respectively). OSI values of spherical vs aspherical lenses were 11.5±3.6 vs 11.8±3.4, 4.1±0.9 vs 3.3±0.8, 3.5±0.9 vs 2.7±0.7, 3.3±0.8 vs 2.6±0.7, 3.2±0.7 vs 2.5±0.8, and 3.2±0.8 vs 2.5±0.8 before and 1d, 1, 2wk, 1 and 2mo after surgery, respectively. All time points varied significantly(P<0.01) between the two groups.CONCLUSION: Aspherical IOLs does not significantly affect visual acuity compared with spherical IOLs. The OSI value, was significantly lower in the aspherical lens group compared with the spherical lens. This study shows that objective visual quality of aspheric IOLs is better than that of the spherical lens by means of OQAS biological measurement method. 展开更多
关键词 optical quality analysis system age-related cataract spherical lens aspherical lens objective scattering index
原文传递
Higher order aberration comparison between two aspherical intraocular lenses: MC6125AS and Akreos advanced optics 被引量:5
3
作者 Mohammad Taher Rajabi Sara Korouji +4 位作者 Mahgol Farjadnia Mohammad Naderan Mohammad Bagher Rajabi Bahram Khosravi Seyed Mehdi Tabatabaie 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2015年第3期565-568,共4页
AIM: To compare higher order aberrations in two aspherical intraocular lenses(IOLs): Akreos advanced optics(AO) and Dr. Schmidt Microcrystalline 6125 aspheric anterior surface(MC6125AS) with each other. METHODS: Forty... AIM: To compare higher order aberrations in two aspherical intraocular lenses(IOLs): Akreos advanced optics(AO) and Dr. Schmidt Microcrystalline 6125 aspheric anterior surface(MC6125AS) with each other. METHODS: Forty eyes of 39 patients underwent phacoemulsification and Akreos AO and MC6125 AS were implanted in their eyes in a random manner. Three months post-operatively, higher order aberrations including spherical aberration, coma aberration, and total aberrations were measured and compared.RESULTS: The total aberration was 0.24±0.17 in eyes with Dr. Schmidt and 0.20 ±0.01 in eyes with Akreos AO(P =0.361). The mean of coma aberration was 0.17 ±0.21 and 0.09 ±0.86 in Dr. Schmidt and Akreos lenses,respectively(P =0.825). Total spherical aberration was almost the same in both groups(mean: 0.05, P =0.933).Best corrected visual acuity in Akreos AO(0.10±0.68) and Dr. Schmidt(0.09±0.67) did not differ significantly(P =0.700). CONCLUSION: There is no statistically significant difference in the higher order aberrations between these two aspherical lenses. 展开更多
关键词 aspherical lenses higher order ABERRATIONS CATARACT INTRAOCULAR lens
原文传递
Personalized aspheric intraocular lens implantation based on corneal spherical aberration: a review 被引量:3
4
作者 Wei Du Wei Lou Qiang Wu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第11期1788-1792,共5页
With the evolution of cataract surgery from visual rehabilitation to refractive surgery, aspheric intraocular lenses(IOLs) are being increasingly used in the field of ophthalmology. This increased use can be attribute... With the evolution of cataract surgery from visual rehabilitation to refractive surgery, aspheric intraocular lenses(IOLs) are being increasingly used in the field of ophthalmology. This increased use can be attributed to negative or zero spherical aberrations with unique optical designs, which counteract some of the positive spherical aberrations of the cornea. These alterations reduce the total spherical aberration of human eyes and improve the visual acuity in patients with cataract postoperatively. At present, various types of aspheric IOLs are used worldwide. Although the implantation of aspheric IOL is beneficial to the patients who need correction of spherical aberrations, much controversy is still associated with ocular residual spherical aberrations that facilitate the best visual quality for patients postoperatively. In order to provide reference for future clinical work and scientific research, this report reviews the relationship between the ocular residual spherical aberration of human eyes and visual quality. 展开更多
关键词 CORNEAL spherical ABERRATION aspheric INTRAOCULAR LENS visual quality
原文传递
Clinical study inpatient-reported outcomes after binocular implantation of aspheric intraocular lens of different negative spherical aberrations 被引量:3
5
作者 Ze-Quan Xu Xu-Hua Song +2 位作者 Wen-Zhe Li Yan Dou Qiang Wu 《Asian Pacific Journal of Tropical Medicine》 SCIE CAS 2017年第7期771-774,共4页
Objective: To compare patient-reported outcomes after implantation of the ZA9003 intraocular lens(IOLs), or the MCX11 ASP IOLs or the spherical IOLs(HQ-201HEP). Methods: Prospective nonrandomized controlled trial was ... Objective: To compare patient-reported outcomes after implantation of the ZA9003 intraocular lens(IOLs), or the MCX11 ASP IOLs or the spherical IOLs(HQ-201HEP). Methods: Prospective nonrandomized controlled trial was used. A total of 105 patients(210 eyes) were divided into three groups according to the type of IOLs: ZA9003(35 patients, 70 eyes), MCX11 ASP(35 patients, 70 eyes) or HQ-201HEP(35 patients, 70 eyes). The main outcome was scores of Catquest nine-item short-form questionnaire. Additional outcome was best corrected visual acuities, spherical aberration(SA) and total higher-order aberrations(HOAs). Results: The global score was significantly lower in the spherical IOL group than the aspherical IOL group of-020 μm SA(P < 0.05) and the aspherical IOL group of-027 μm SA(P < 0.05), and no significant difference was found in the global score between the aspherical IOL group of-020 μm SA than the aspherical IOL group of-027 μm SA(P > 0.05). Significant differences were also found in question 2, question 5, question 6 and question 8 between the spherical IOLs and the aspherical IOLs. Conclusion: Implantation of an aspherical IOL could improve vision-related quality of life compared with a spherical IOL. However, there were no statistically significant differences in vision-related quality of life between aspheric IOLs with different negative spherical aberrations. 展开更多
关键词 Catquest nine-item short-form Patient-reported outcomes Vision-related quality aspheric intraocular lens Spherical aberration
下载PDF
Comparison of visual quality after implantation of Al-UV and SN60WF aspheric intraocular lens 被引量:2
6
作者 Xuan Liao Ji-Yun Li +3 位作者 Qing-Qing Tan Jing Tian Jia Lin Chang-Jun Lan 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第11期1727-1732,共6页
AIM:To compare the visual performance of pseudophakic eyes implanted with Al-UV and SN60WF aspheric intraocular lens(IOL),and to investigate the correlations between visual quality parameters and pupil size.METHODS:Th... AIM:To compare the visual performance of pseudophakic eyes implanted with Al-UV and SN60WF aspheric intraocular lens(IOL),and to investigate the correlations between visual quality parameters and pupil size.METHODS:This prospective comparative study included 105 eyes of 90 patients with age-related cataract who underwent uneventful phacoemulsification.The subjects were divided into two groups according to the implanted IOL type.Three months postoperatively,visual acuity and contrast sensitivity were measured,wave-front aberrations were assessed using a KR-IW aberrometer(Topcon),and objective optical quality parameters were performed using an optical quality analysis system-OQAS Il(Visiometrics).Independent sample Mest and Spearman correlation analysis were used for data analysis.RESULTS:There were no significant differences found in visual acuity,contrast sensitivity and visual quality parameters between the two groups(P>0.05).The measured intraocular spherical aberration(SA)in Al-UV IOL eyes of-0.19±0.05 pm was close to the designed SA value of-0.20 pm.The modulation transfer function cutoff,Strehl ratio and OQAS values were negatively correlated with pupil size in both groups(P<0.01).CONCLUSION:The subjective and objective visual quality in pseudophakic eyes with A1-UV and SN60WF IOLs are comparable.For aspheric IOL eyes,visual quality decreases with increasing pupil size. 展开更多
关键词 CATARACT aspheric intraocular lens visual quality pupil size
原文传递
Effect of intracorneal ring segment implantation on corneal asphericity 被引量:2
7
作者 Canan A.Utine Ziya Ayhan Ceren Durmaz Engin 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第8期1303-1307,共5页
AIM: To evaluate the visual, refractive and corneal asphericity changes after intrastromal corneal ring segment(ICRS) implantation for visual rehabilitation of keratoconus.METHODS: A total of 42 eyes of 32 patients we... AIM: To evaluate the visual, refractive and corneal asphericity changes after intrastromal corneal ring segment(ICRS) implantation for visual rehabilitation of keratoconus.METHODS: A total of 42 eyes of 32 patients were included. After creation of intrastromal tunnels of 5.01±0.03 mm inner diameter, 5.71±0.03 mm outer diameter and at 384.21±34.12 μm depth, 1 or 2 ICRS of 150-300 μm thickness and 90°-210° arc length were implanted. Changes in uncorrected distance visual acuity(UDVA), corrected distance visual acuity(CDVA), refractive errors, mean simulated keratometry readings SimK_(avg), anterior and posterior corneal asphericity values(Q_(ant) and Q_(post), respectively) measured with Scheimpflug topography were evaluated retrospectively. RESULTS: There was a significant improvement in UDVA and CDVA, along with a significant decrease in refractive spherical equivalent(SE), cylinder and SimK_(avg) postoperatively(P<0.001 for all). Mean Qant increased from-1.06±0.48 to-0.57±0.58 postoperatively(P<0.001). Change in mean Qpost was insignificant(P=0.92). Postoperative changes in UDVA and CDVA were not correlated with the postoperative changes in SE and cylinder(P>0.05 for all); but were correlated with the preoperative SimK_(avg) and Q_(ant) values(P<0.001 for all). CONCLUSION: ICRS implantation seems to approximate the anterior corneal asphericity of "advanced prolate" shape to "optimal prolate" shape and an "ideal Q value" of-0.46; which may have a role in improved UDVA and CDVA postoperatively, besides decreased refractive cylinder values. 展开更多
关键词 cornea ectasia corneal asphericity intracorneal ring segments KERATOCONUS Q value
原文传递
Interchangeability of corneal curvature and asphericity measurements provided by three different devices 被引量:2
8
作者 David P.Pinero Roberto Soto-Negro +2 位作者 Pedro Ruiz-Fortes Rafael J Pérez-Cambrodí Hideki Fukumitsu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第3期412-416,共5页
AIM: To evaluate the interchangeability of keratometric and asphericity measurements provided by three measurement systems based on different optical principles.METHODS: A total of 40 eyes of 40 patients with a mean a... AIM: To evaluate the interchangeability of keratometric and asphericity measurements provided by three measurement systems based on different optical principles.METHODS: A total of 40 eyes of 40 patients with a mean age of 34.1 y were included. In all cases, a corneal curvature analysis was performed with IOL-Master(IOLM), iDesign 2(ID2), and Sirius systems(SIR). Differences between instruments for flattest(K1) and steepest(K2) keratometric readings, as well as for magnitude and axis of corneal astigmatism were analyzed. Likewise, differences in asphericity(Q) between SIR and ID2 were also evaluated. RESULTS: Mean differences between devices for K1 were 0.20±0.21(P<0.001),-0.12±0.36(P=0.046) and-0.32±0.36 D(P<0.001) for the comparisons IOLM-SIR, IOLM-ID2 and SIR-ID2, respectively. The ranges of agreement for these comparisons between instruments were 0.41, 0.70, and 0.70 D. For K2, mean differences were 0.31±0.33(P<0.001),-0.08±0.43(P=0.265) and-0.39±0.38 D(P<0.001), with ranges of agreement of 0.65, 0.84, and 0.74 D. Concerning magnitude of astigmatism, ranges of agreement were in the limit of clinical relevance(0.49 D, P=0.011; 0.55 D, P=0.386; 0.43 D, P=0.05). In contrast, ranges of agreement were clinically relevant for astigmatic axis(26.68o, 33.83o and 18.37o, P≥0.121) and for Q between SIR and ID2(0.16, P<0.001). CONCLUSION: The keratometric corneal power, astigmatic axis and asphericity measurements provideby the three systems evaluated cannot be considered as interchangeable, whereas measurements of corneal astigmatism obtained with SIR and ID2 can be considered as interchangeable for clinical purposes. 展开更多
关键词 ASTIGMATISM corneal topography KERATOMETRY corneal asphericity
原文传递
Study on Injection Moulding of High Precision Aspheric Plastic Lens 被引量:1
9
作者 TO Suet LEE Wing-bun 《厦门大学学报(自然科学版)》 CAS CSCD 北大核心 2002年第S1期132-,共1页
With the rapid development of information and multi me dia technologies, the demand for the optical plastic aspheric elements used in o pto-electronic devices, camera, optical disc and projector lens etc. has been i n... With the rapid development of information and multi me dia technologies, the demand for the optical plastic aspheric elements used in o pto-electronic devices, camera, optical disc and projector lens etc. has been i ncreased rapidly in the recent years. The key technologies of fabrication of asp heric plastic lens are the design and manufacturing moulds, selection of proper injection moulding equipment, and optimization of injection moulding parameters etc. In this paper, the effect of injection pressure, moulding temperature, cool ing time and injection speed on the surface profile of the lenses during injecti on and holding process is investigated. Surface quality of plastic lenses is mea sured by Talysurf Texture Measuring System. The experimental results showed that the injection pressure and moulding temperature are important parameters compar ing to cooling time and injection speed. A bit change of injection pressure or m oulding temperature will affect the property of the surface profile. Either incr easing injection pressure or mould temperature can achieve less shrinkage. Other wise, a lower injection pressure will produce more shrinkage, more air traps and a lower mould temperature results greater warp and higher shrinkage. The dynami c process of injection for optical plastic lenses is simulated by 3D Moldflow pl astic Insight software (MPI). The MPI will help us to optimize injection mouldin g parameters. 展开更多
关键词 injection moulding aspheric lens optical compon ent OPTIMIZATION
下载PDF
ASPHERICITY AND PROLATENESS OF LINEAR AND CIRCULAR MACROMOLECULES 被引量:1
10
作者 魏高原 《Chinese Journal of Polymer Science》 SCIE CAS CSCD 1995年第3期204-209,共6页
The shape asymmetry of gaussian models of linear and circular macromolecules hasbeen numerically invesigated in terms of asphericity and prolateness parameters. Theseparameters are found to decrease with increasing le... The shape asymmetry of gaussian models of linear and circular macromolecules hasbeen numerically invesigated in terms of asphericity and prolateness parameters. Theseparameters are found to decrease with increasing length for the macromolecule eitherconfined to a plane or in three dimensions. The effect of dimensionality on theseparameters is visible only for low dimensions and is generally weak. As dimensionality goesto infinity, it is found that asphericity and prolateness for both chains and rings approachslowly yet descendingly values of corresponding asphericity and prolateness factors, withthe exception of the chain which shows a minimum value of asphericity when theembedding space has a dimensionality of four. 展开更多
关键词 asphericITY Prolateness Macromolecular SHAPE THEORY
下载PDF
Wheel Setting Error Modeling and Compensation for Arc Envelope Grinding of Large-Aperture Aspherical Optics 被引量:1
11
作者 Changsheng Li Lin Sun +4 位作者 Zhaoxiang Chen Jianfang Chen Qijing Lin Jianjun Ding Zhuangde Jiang 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2022年第5期87-99,共13页
Precision grinding is a key process for realizing the use of large-aperture aspherical optical elements in laser nuclear fusion devices,large-aperture astronomical telescopes,and high-resolution space cameras.In this ... Precision grinding is a key process for realizing the use of large-aperture aspherical optical elements in laser nuclear fusion devices,large-aperture astronomical telescopes,and high-resolution space cameras.In this study,the arc envelope grinding process of large-aperture aspherical optics is investigated using a CM1500 precision grinding machine with a maximum machinable diameter ofΦ1500 mm.The form error of the aspherical workpiece induced by wheel setting errors is analytically modeled for both parallel and cross grinding.Results show that the form error is more sensitive to the wheel setting error along the feed direction than that along the lateral direction.It is a bilinear function of the feed-direction wheel setting error and the distance to the optical axis.Based on the error function above,a method to determine the wheel setting error is proposed.Subsequently,grinding tests are performed with the wheels aligned accurately.Using a newly proposed partial error compensation method with an appropriate compensation factor,a form error of 3.4μm peak-to-valley(PV)for aΦ400 mm elliptical K9 glass surface is achieved. 展开更多
关键词 aspherical optics Wheel setting Arc envelope grinding Form error Large aperture
下载PDF
A New Locus Shaping Method of Quadric Aspheric Parts
12
作者 王院生 王鹤岩 +2 位作者 路桂英 蔡立 朴承镐 《Defence Technology(防务技术)》 SCIE EI CAS 2005年第2期233-239,共7页
The original idea and shaping principle of locus shaping method for processing the aspheric optical parts are introduced, and the partial structure of the machine tool designed is described. The method has the advanta... The original idea and shaping principle of locus shaping method for processing the aspheric optical parts are introduced, and the partial structure of the machine tool designed is described. The method has the advantage of high efficiency and low cost compared to the numerical control method. And it is proven that the method is feasible. 展开更多
关键词 aspheric SURFACE CONIC CURVE CONIC curved SURFACE LOCUS SHAPING method
下载PDF
Asphericity in the Fermi Surface and Fermi Energy of Na-K, Na-Rb and Na-Cs Binary Alloys
13
作者 Minal H. Patel A.M. Vora P.N. Gajjar A.R. Jani 《Communications in Theoretical Physics》 SCIE CAS CSCD 2002年第9期365-369,共5页
Detailed theoretical investigations into asphericity in the Fermi surface (FS) and Fermi energy (FE) ofNa1_xKx, Na1_xRbx, and Na1_xCsx binary solid solutions are carried out for the first time. The alloying behavior o... Detailed theoretical investigations into asphericity in the Fermi surface (FS) and Fermi energy (FE) ofNa1_xKx, Na1_xRbx, and Na1_xCsx binary solid solutions are carried out for the first time. The alloying behavior ofthe K, Rb, and Cs with the Na generates the Fermi surface distortion (FSD) of bce simple metals. The FS of Na-K,Na-Rb, and Na-Cs solid solution is a distorted sphere with the largest deviation along [110]. We have found that theimpact of local-field correction function on FSD is maximun at [100] point and minimum at [111] point. The exchangeand correlation effect is found to suppress the value of FE. 展开更多
关键词 asphericITY in the FERMI surface FERMI energy pseudopotential exchange and correlation effects binary alloys
下载PDF
Research on Large Depth Diameter Ratio Ultra-precision Aspheric Grinding System
14
作者 CHEN Ming-jun, LI Dan, DONG Shen (Precision Engineering Research Institute, Harbin Institute of Technology, Harbin 150001, China) 《厦门大学学报(自然科学版)》 CAS CSCD 北大核心 2002年第S1期26-27,共2页
In this paper, the factors of affecting surface roughness and profiles accuracy of the machined larege depth diamter ratio aspheric surfaces in ultra-precision grinding process are analyzed theoretically. An ultra-pre... In this paper, the factors of affecting surface roughness and profiles accuracy of the machined larege depth diamter ratio aspheric surfaces in ultra-precision grinding process are analyzed theoretically. An ultra-precision aspheric grinding system is then designed and manufactured. Aerostatic form is adopted to build the spindle of the workpiece, transverse guideway, longitudinal guideway and the spindle of the grinder in this system. The following specification is achieved, such as the turning accuracy of the spindle of the workpiece is 0.05 μm, radial rigidity of the spindle is GE 220N/μm, axial rigidity is GE 160 N/μm, radial rigidity of the guideway is GE 200N/μm, the highest rotational speed of the grinder is 80 000 rev/min and its turning accuracy is 0.1 μm, the resolution of linear displacement of the transverse and longitudinal guideway is 4.9 nm. Adjusting range of this adjusting mechanism is 2 mm in the Y direction, the adjusting accuracy of the precise adjusting mechanism is 0.1 μm. Micro displacement measuring system of this ultra-precision aspheric grinding adopts two-backfeed strategy, and angle displacement back-feed is realized by photoelectric encoder, it’s resolution is 655 360 pulse/rev. after 4 frequency multiplication, it’s angle displacement resolution is achieved 2 621 440 pulse/rev. Straight-line displacement is monitored by single frequency laser interferometer (DLSTAX LTM-20B, made in Japan). This CNC system adopts inimitable bi-arc step length flex CN interpolation algorithm, it’s CN system resolution is 5 nm.So this aspheric grinding system ensures profile accuracy of the machined part. The resolution of this interferometer is 5 nm. Finally, lots of ultra-precision grinding experiments are carried out on this grinding system. Some optical aspheric parts, with profiles accuracy of 0.3 μm, surface roughness less than 0.01 μm, are obtained. 展开更多
关键词 ultra-precision grinding optical aspheric surface precise adjusting mechanism large depth diameter ratio
下载PDF
Design of Ultra-Precision CNC Grinding Machine and Its Application in Machining Large Aspheric Mirrors
15
作者 Bin Li Huiying Zhao +1 位作者 Jianpu Xi Dongxu Ren 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2015年第2期61-66,共6页
Large aspheric mirrors are needed for the remote sensing and ground based telescope optical systems,these mirrors are made of hard and brittle materials which require ultra-precision grinding process to guarantee the ... Large aspheric mirrors are needed for the remote sensing and ground based telescope optical systems,these mirrors are made of hard and brittle materials which require ultra-precision grinding process to guarantee the high profile accuracy and machining efficiency. The ultra-precision aspheric CNC grinding machine( UAG900) is presented by this paper,as well as its grinding capability. The hydrostatic bearings of high accuracy and stiffness are adopted by the linear and rotary motions to guarantee the mirror accuracy,material removal rate and subsurface damage. Disk type grinding wheel with arc edge is used. The material removal rate can be up to 360 mm3/ min to guarantee the machining efficiency during rough grinding using D180 diamond grinding wheel while the fine grinding is performed using D15 grinding wheel. It indicates that the grinding wheel radius measuring error is proportional to the profile error induced by the grinding path. The grinding step size is better to be 0. 01 mm for the reduction of the grinding movement accelerations and program length. The grinding path is planned and expressed based on the grinding mode according to the mirror shape. One540 mm×450 mm× 100 mm zerodur mirror is ground and re-ground using the measuring data acquired by the Leitz CMM. The final surface accuracy of P-V value is less than 5 μm after compensation grinding. 展开更多
关键词 ULTRA-PRECISION large aspheric mirror compensation grinding
下载PDF
Computer Controlled Polishing of the Off-axis Aspheric Mirrors 被引量:4
16
作者 ZHANG Xue jun,WENG Zhi cheng,ZHANG Zhong yu, WANG Quan dou,ZHANG Feng (Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130022, China) 《光学精密工程》 EI CAS CSCD 2001年第5期467-473,共7页
In this paper, the manufacturing and testing procedures to make large off-axis aspherical mirrors are presented. The difficulties in polishing and testing for both circular aperture and rectangular aperture mirrors ar... In this paper, the manufacturing and testing procedures to make large off-axis aspherical mirrors are presented. The difficulties in polishing and testing for both circular aperture and rectangular aperture mirrors are previewed, and a possible solution is given. The two mirrors have been polished by means of CCOS, and the final accuracy is 25nm rms for 770mm×210mm rectangular mirror and 20nm rms for φ600mm circular mirror. These results just meet the optical tolerances specified by the designer, and the manufacturing and testing procedures presented here show good ability to make the large off-axis aspherical mirrors. 展开更多
关键词 asphere computer-controlled POLISHING OPTICAL TESTING
下载PDF
High-speed, large-area and high-precision fabrication of aspheric micro-lens array based on 12-bit direct laser writing lithography
17
作者 Shiyi Luan Fei Peng +3 位作者 Guoxing Zheng Chengqun Gui Yi Song Sheng Liu 《Light(Advanced Manufacturing)》 2022年第4期50-60,共11页
Aspheric micro-lens array(AMLA),featured with low dispersion and diffraction-limited imaging quality,plays an important role in advanced optical imaging.Ideally,the fabrication of commercially applicable AMLAs should ... Aspheric micro-lens array(AMLA),featured with low dispersion and diffraction-limited imaging quality,plays an important role in advanced optical imaging.Ideally,the fabrication of commercially applicable AMLAs should feature low cost,high precision,large area and high speed.However,these criteria have been achieved only partially with conventional fabrication process.Herein,we demonstrate the fabrication and characterization of AMLAs based on 12-bit direct laser writing lithography,which exhibits a high fabrication speed,large area,perfect lens shape control via a three-dimensional optical proximity correction and average surface roughness lower than 6 nm.In particular,the AMLAs can be flexibly designed with customized filling factor and arbitrary off-axis operation for each single micro-lens,and the proposed pattern transfer approach with polydimethylsiloxane(PDMS)suggests a low-cost way for mass manufacturing.An auto-stereoscopic-display flexible thin film with excellent display effect has been prepared by using above technology,which exhibits a new way to provide flexible auto-stereoscopic-display at low cost.In brief,the demonstrated fabrication of AMLAs based on direct laser writing lithography reduce the complexity of AMLA fabrication while significantly increasing their performance,suggesting a new route for high-quality three-dimentional optical manufacturing towards simplified fabrication process,high precision and large scale. 展开更多
关键词 aspheric micro-lens array Large-area fabrication Sub 6 nm roughness 12-bit direct laser writing lithography
原文传递
Current Status of Extreme Ultraviolet Lithography in Japan 被引量:2
18
作者 Kazuya Ota, Iwao Nishiyama, Taro Ogawa, Ei Yano, Shinji Okazaki (ASET EUV Laboratory, Atsugi-Shi, Kanagawa 243-0198, 《光学精密工程》 EI CAS CSCD 2001年第5期424-429,共6页
ASET, Association of Super-advanced Electronics Technologies, has been taking the initiative in developing EUV lithography technology in Japan for the past three years. The aspherical mirror metrology using a visible ... ASET, Association of Super-advanced Electronics Technologies, has been taking the initiative in developing EUV lithography technology in Japan for the past three years. The aspherical mirror metrology using a visible light point diffraction interferometer (PDI), the wave front measurement using an at-wavelength PDI, and an at wavelength reflectometry for multilayers, various imaging simulations, multilayer coatings for the mask, the development of absorber materials for mask patterning, the mask substrate cleaning technique, and various photoresist processes have been developed. The visible light PDI employs a 0.5-μm pinhole as an aperture to generate an ideal spherical wave front and can measure a 0.3-N A mirror maximum. The at-wavelength PDI can measure the wave front error of the projection optics. The at-wavelength reflectometer can measure the reflectivity of multilayers and the round-robin test is taking place among ASET, the ALS in Lawrence Berkeley, and BESSY in Germany. The mask cleaning technique employs a supersonic hydro-cleaning technique. We have confirmed that the single layer resists can be used for EUV lithography. 展开更多
关键词 ULTRAVIOLET LITHOGRAPHY aspherical mirrors ALIGNMENT SYSTEMS
下载PDF
Design of a Modified Cassegrain System Used in Joint Transform Correlator
19
作者 MA Yongli WANG Wensheng 《Semiconductor Photonics and Technology》 CAS 2010年第2期68-72,共5页
In order to detect and recognize infrared target with joint transform correlator,a modified Cassegrain optical system is designed.The main advantages of the system are large field-of-view,infrared dual-band common opt... In order to detect and recognize infrared target with joint transform correlator,a modified Cassegrain optical system is designed.The main advantages of the system are large field-of-view,infrared dual-band common optical path and compact structure.In the modified Cassegrain optical system,the working wavelengths are 3.7~4.8μm and 8~12μm,the field-of-view is 4° and the aperture is 240mm.The paraboloidal primary mirror and hyperboloidal secondary mirror are all replaced by spherical surfaces.So the problems of high machining accuracy and alignment become much easier.In order to balance the aberrations,three compensating lenses are used in the system.The total length of the system is 183mm,and the ratio of the total length to focal length is 0.68.Moreover,the system has a good performance of athermalization between negative 40℃ and positive 60℃.The design results of the system show that the MTF value of each field is greater than 0.72 when the cut-off frequency is 11lp/mm.Due to the excellent image quality of the modified optical system,the ability of Joint transform correlator(JTC)applied in target tracking and identification has been improved for further. 展开更多
关键词 optical design joint transform correlator infrared dual-band aspherical surface Cassegrain optical system
下载PDF
3D Modelling of Thermal Replication for Designing Progressive Glass Moulds
20
作者 Dominique Lochegnies Philippe Moreau +1 位作者 Fabienne Hanriot Patrick Hugonneaux 《New Journal of Glass and Ceramics》 2013年第1期34-42,共9页
Worldwide, ESSILOR International provides customers with Progressive Addition Lenses (PAL), which replace bifocal lenses. Thermal replication is one process to produce glass moulds for PAL, using sagged glass on a cer... Worldwide, ESSILOR International provides customers with Progressive Addition Lenses (PAL), which replace bifocal lenses. Thermal replication is one process to produce glass moulds for PAL, using sagged glass on a ceramic slumping block. In this paper, thermal replication for producing PAL glass moulds is developed through 3D modelling and experimentation. Our numerical approach is validated by comparing it with experimentation on the global 3D topology of the sagged glass. It is also validated by using more severe optical comparison criteria, developed by ESSILOR International to analyze the conformity of their products. Through modelling, the thermal replication is analyzed by studying the evolving contact between the sagged glass and the ceramic slumping block during the thermal cycle and the glass flow on the upper side of the sagged glass. 展开更多
关键词 aspherical LENS Finite Element Model Precision Glass FORMING THERMAL REPLICATION METROLOGY
下载PDF
上一页 1 2 下一页 到第
使用帮助 返回顶部