期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Proton Radioactivity Within a Hybrid Method 被引量:1
1
作者 张鸿飞 《原子核物理评论》 CAS CSCD 北大核心 2016年第2期167-172,共6页
The proton radioactivity half-lives are investigated theoretically within a hybrid method.The potential barriers preventing the emission of protons are determined in the quasimolecular shape path within a generalized ... The proton radioactivity half-lives are investigated theoretically within a hybrid method.The potential barriers preventing the emission of protons are determined in the quasimolecular shape path within a generalized liquid drop model(GLDM). The penetrability is calculated with the WentzelKramers-Brillouin(WKB) approximation. The spectroscopic factor has been taken into account in halflife calculation, which is obtained by employing the relativistic mean field(RMF) theory combined with the Bardeen-Cooper-Schrieffer(BCS) method. The half-lives within the present hybrid method reproduced the experimental data very well. Some predictions for proton radioactivity are made for future experiments. 展开更多
关键词 proton radioactivity generalized liquid drop model WKB approximation bcs method relativistic mean field theory
原文传递
Study of n-γ discrimination in low energy range(above 40 keVee) by charge comparison method with a BC501A liquid scintillation detector 被引量:3
2
作者 陈永浩 陈熙萌 +8 位作者 张小东 雷家荣 安力 邵剑雄 郑普 王新华 朱传新 何铁 阳剑 《Chinese Physics C》 SCIE CAS CSCD 2014年第3期26-30,共5页
A VME-based experiment system for n-y discrimination using the charge comparison method was established.A data acquisition program for controlling the programmable modules and processing data online via VME64X bus was... A VME-based experiment system for n-y discrimination using the charge comparison method was established.A data acquisition program for controlling the programmable modules and processing data online via VME64X bus was developed through the use of Lab VIEW.The two-dimensional(2D) scatter plots of the charge in the slow component vs.the total charge from ^(241)Am-Be and 252Cf neutron sources are presented.The 2D scatter plots of the energy vs.the ratio of the charge in the slow component to the total charge of the pulses are also presented.The quality of n-γ discrimination was checked by the figure-of-merit,and the results showed good performance of n-γ discrimination at the low energy range.Neutrons and γ-rays were separated above 50 keVee(electron-equivalent energy).The quality of n-γ discrimination has been improved compared with others' results at five energies(150,250,350,450,550 keVee). 展开更多
关键词 n-γ discrimination charge comparison method VME bus BC501A liquid scintillation detector low energy range
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部