期刊文献+
共找到9,156篇文章
< 1 2 250 >
每页显示 20 50 100
Biomechanical Response of the Root System in Tomato Seedlings under Wind Disturbance
1
作者 Zhengguang Liu Jun Yang +2 位作者 Tobi Fadiji Zhiguo Li Jiheng Ni 《Phyton-International Journal of Experimental Botany》 SCIE 2023年第4期1071-1090,共20页
Wind disturbance as a green method can effectively prevent the overgrowth of tomato seedlings,and its mechanism may be related to root system mechanics.This study characterized the biophysical mechanical properties of... Wind disturbance as a green method can effectively prevent the overgrowth of tomato seedlings,and its mechanism may be related to root system mechanics.This study characterized the biophysical mechanical properties of taproot and lateral roots of tomato seedlings at five seedling ages and seedling substrates with three different moisture content.The corresponding root system-substrate finite element(FE)model was then developed and validated.The study showed that seedling age significantly affected the biomechanical properties of the taproot and lateral roots of the seedlings and that moisture content significantly affected the biomechanical properties of the seedling substrate(p<0.05).The established FE model was sensitive to wind speed,substrate moisture content,strong seedling index,and seedling age and was robust.The multiple linear regression equations obtained could predict the maximum stress and strain of the root system of tomato seedlings in the wind field.The strong seedling index had the greatest impact on the biomechanical response of the seedling root system during wind disturbance,followed by wind speed.In contrast,seedling age had no significant effect on the biomechanical response of the root system during wind disturbance.In the simulation,no mechanical damage was observed on the tissue of the seedling root system,but there were some strain behaviors.Based on the plant stress resistance,wind disturbance may affect the growth and development of the root system in the later growth stage.In this study,finite element and statistical analysis methods were combined to provide an effective approach for indepth analysis of the biomechanical mechanisms of wind disturbances that inhibit tomato seedlings’growth from the root system’s perspective. 展开更多
关键词 Tomato seedling root system age level wind disturbance biomechanical response finite element analysis
下载PDF
Rotator cuff repair with an interposition polypropylene mesh:A biomechanical ovine study
2
作者 Winston Shang Rong Lim Andy Khye Soon Yew +2 位作者 Hannah Lie Siaw Meng Chou Denny Tijauw Tjoen Lie 《World Journal of Orthopedics》 2023年第5期319-327,共9页
BACKGROUND Chronic large to massive rotator cuff tears are difficult to treat and re-tears are common even after surgical repair.We propose using a synthetic polypropylene mesh to increase the tensile strength of rota... BACKGROUND Chronic large to massive rotator cuff tears are difficult to treat and re-tears are common even after surgical repair.We propose using a synthetic polypropylene mesh to increase the tensile strength of rotator cuff repairs.We hypothesize that using a polypropylene mesh to bridge the repair of large rotator cuff tears will increase the ultimate failure load of the repair.AIM To investigate the mechanical properties of rotator cuff tears repaired with a polypropylene interposition graft in an ovine ex-vivo model.METHODS A 20 mm length of infraspinatus tendon was resected from fifteen fresh sheep shoulders to simulate a large tear.We used a polypropylene mesh as an interposition graft between the ends of the tendon for repair.In seven specimens,the mesh was secured to remnant tendon by continuous stitching while mattress stitches were used for eight specimens.Five specimens with an intact tendon were tested.The specimens underwent cyclic loading to determine the ultimate failure load and gap formation.RESULTS The mean gap formation after 3000 cycles was 1.67 mm in the continuous group,and 4.16 mm in the mattress group(P=0.001).The mean ultimate failure load was significantly higher at 549.2 N in the continuous group,426.4 N in the mattress group and 370 N in the intact group(P=0.003).CONCLUSION The use of a polypropylene mesh is biomechanically suitable as an interposition graft for large irreparable rotator cuff tears. 展开更多
关键词 Rotator cuff repair Massive tear Interposition graft biomechanicS Polypropylene mesh
下载PDF
Changes in corneal biomechanics and posterior corneal surface elevation after FS-LASIK
3
作者 Zhong-Ji Li Chen Yang +2 位作者 Su-Han Liu Jiao Guo Yu-Hui Duan 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第11期1832-1837,共6页
AIM:To investigate the changes in corneal biomechanics and posterior corneal surface elevation after femtosecond laser-assisted in situ keratomileusis(FS-LASIK).METHODS:Totally 197 eyes of 100 patients who underwent t... AIM:To investigate the changes in corneal biomechanics and posterior corneal surface elevation after femtosecond laser-assisted in situ keratomileusis(FS-LASIK).METHODS:Totally 197 eyes of 100 patients who underwent the FS-LASIK from April 2022 to November 2022 were included.They were divided into three groups according to the ratio of residual corneal stroma thickness/corneal thickness(RCST/CT):Group I(50%≤RCST/CT<55%,63 eyes of 32 patients),Group II(55%≤RCST/CT<60%,67 eyes of 34 patients),and Group III(RCST/CT≥60%,67 eyes of 34 patients).The intraocular pressure(IOP),corneal compensated IOP(IOPcc),corneal hysteresis(CH)and corneal resistance factor(CRF)were measured immediately,1,and 3mo postoperatively by ocular response analyzer(ORA)and the posterior elevation difference(PED)was measured by Pentacam.RESULTS:After operation,IOP,CH,CRF,and PED were statistically different among the three groups(F=12.99,31.148,23.998,all P<0.0001).There was no statistically significant difference in IOPcc among the three groups(F=0.603,P>0.05).The IOP,IOPcc,CH,and CRF were statistical changed after surgery(F=699.635,104.125,308.474,640.145,all P<0.0001).The PED of Group I was significantly higher than that of Group II(P<0.05),and Group II was significantly higher than that of Group III(P<0.05).The PED value of 3mo after surgery decreased in each group compared with 1mo after surgery,but there was no statistical difference(Group I:t=0.82,P=0.41;Group II:t=0.17,P=0.87;Group III:t=1.35,P=0.18).The correlation analysis of corneal biomechanical parameter changes with PED at 1mo and 3mo after surgery showed thatΔIOP,ΔIOPcc,ΔCH,andΔCRF were not correlated with PED value in three groups(P>0.05).CONCLUSION:The smaller the RCST/CT,the greater effect on corneal biomechanics and posterior surface elevation.There is no correlation between changes in corneal biomechanics and posterior corneal surface elevation in the range of RCST/CT≥50%. 展开更多
关键词 femtosecond laser-assisted in situ keratomileusis corneal biomechanics posterior corneal surface elevation
原文传递
Pregnancy-Induced Changes in Ocular Biomechanics Are Related to Maternal Hormone Levels in Healthy Chinese Pregnant Women
4
作者 Jianting Zhou Fangyuan Chen +2 位作者 Xiaojuan He Xiaoxue Han Qing Zhou 《International Journal of Clinical Medicine》 2023年第11期457-471,共15页
Background: To explore the changes in ocular biomechanics during pregnancy and the postpartum period and their association with maternal hormone level changes. Methods: In a prospective cohort study, 24 eyes of 12 pre... Background: To explore the changes in ocular biomechanics during pregnancy and the postpartum period and their association with maternal hormone level changes. Methods: In a prospective cohort study, 24 eyes of 12 pregnant women were enrolled and monitored throughout pregnancy and after delivery (6 weeks). Intraocular pressure (IOP), central corneal thickness (CCT), corneal endothelium cell (CEC), axial length (AL), corneal curvature (K1, K2), anterior chamber depth (ACD), central subfield thickness (CST), macular volume (MV), cube average thickness (CAT), retinal nerve fibre layer (RNFL), tear meniscus height (TMH), and breaking up time (BUT) were measured throughout pregnancy, and blood plasma levels of maternal hormones were determined at the same time points. Results: A gradual decrease in IOP values was observed as gestation progressed, and there was a statistically significant difference in IOP between the 3rd trimester and the 1st and 2nd trimester and postpartum (p = 0.002, p = 0.006, p = 0.050). There was a significant difference between the 1st and 2nd trimesters in terms of MV (p = 0.023). The difference in RNFL in the 3rd trimester and postpartum was significant (p = 0.011). The levels of the β-hCG showed a significant correlation with K2, ACD, and TMH only in the 2nd trimester (r = 0.588, p = 0.045;r = - 0.740, p = 0.006;r = 0.642, p = 0.024). Regarding luteinizing hormone, there was a negative correlation with MV in the 1st and 2nd trimesters (r = - 0.598, p = 0.040;r = - 0.672, p = 0.017) and CAT in the 1st and 2nd trimesters (r = - 0.599, p = 0.040;r = - 0.655, p = 0.021). Luteinizing hormone levels were correlated with ACD (r = - 0.702, p = 0.011) in the 2nd trimester and K2 (r = 0.585, p = 0.046) in the 3rd trimester. A correlation was found between follicle-stimulating hormone levels and CEC, MV and CAT in the 1st trimester (r = - 0.677, p = 0.016;r = - 0.602, p = 0.039;r = - 0.584, p = 0.046) and AL in the 3rd trimester (r = - 0.618, p = 0.032). The correlation between oestradiol and CST in the 1st trimester (r = - 0.621, p = 0.031) and RNFL (r = 0.594, p = 0.041) in the postpartum. A statistically significant correlation between progesterone and MV (r = 0.583, p = 0.047) and TMH (r = 0.762, p = 0.004) was observed in the 1st trimester. No significant intergroup correlation was observed postpartum (p > 0.05). Conclusion: Ophthalmological parameters showed physiological changes induced by hormone levels in pregnancy and returned to baseline levels after delivery. 展开更多
关键词 PREGNANCY HORMONES Ocular biomechanics Hormone-Related Differences
下载PDF
Effect of cervical spine surgery on the biomechanics of the cervical spine
5
作者 Jie Wang Ke-Xin Jiang Hao-Peng Li 《Biomedical Engineering Communications》 2023年第1期29-33,共5页
In clinical practice,cervical spine surgery inevitably alters the original physiological structure of the cervical spine,thus causing changes in the original biomechanical properties of the cervical spine.The biomecha... In clinical practice,cervical spine surgery inevitably alters the original physiological structure of the cervical spine,thus causing changes in the original biomechanical properties of the cervical spine.The biomechanical properties of the cervical spine are particularly significant as it is an essential structure that supports the head and connects the trunk.Different cervical spine surgery options can have different effects on the biomechanics of the cervical spine.Therefore,this review will discuss recent research advances on the effects of cervical spine surgery on cervical spine biomechanics.We hope that this review will provide some theoretical basis for future studies on the biomechanical effects of cervical spine surgery on the cervical spine. 展开更多
关键词 cervical spine SURGERY biomechanicS IMPLANT surgical approaches
下载PDF
Short and long term corneal biomechanical analysis after overnight orthokeratology 被引量:1
6
作者 Amelia Nieto-Bona Paloma Porras-Ángel +2 位作者 Adela Elena Ayllón-Gordillo Gonzalo Carracedo David P Piñero 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2022年第7期1128-1134,共7页
AIM: To investigate the short and long term corneal biomechanical changes after overnight orthokeratology(OK) and compare them with those occurring in subjects not wearing contact lenses.METHODS: Retrospective case co... AIM: To investigate the short and long term corneal biomechanical changes after overnight orthokeratology(OK) and compare them with those occurring in subjects not wearing contact lenses.METHODS: Retrospective case control study enrolling 54 subjects that were divided into three groups 18 subjects each: control group(CG), short term(15 nights) OK(STOK) group, and long term(more than 1 y of OK wear) OK(LTOK) group. Corneal biomechanics were characterized using the Cor Vis? ST system(Oculus), recording parameters such as time [first/second applanation time(AT1, AT2)], speed [velocity of corneal apex at the first/second applanation time(AV1, AV2)], and amplitude of deformation(AD1, AD2) in the first and second corneal flattening, corneal stiffness(SPA1), biomechanically corrected intraocular pressure(b IOP) and corneal(CBI) and tomographic biomechanical indices(TBI).RESULTS: Significantly lower AD1 and standard deviate on of Ambrosio’s relational average thickness related to the horizontal profile(ARTh) values were found in the OK groups compared to CG(P<0.05). Likewise, significantly higher values of CBI were found in STOK and LTOK groups compared to CG(P<0.01). No significant differences between groups were found in integrated radius index(P=0.24), strain stress index(P=0.22), tomographic biomechanical index(P=0.91) and corneal stif fness parameter(SPA1, P=0.97). Significant inverse correlations were found between corneal thickness and CBI in STOK(r=-0.90, P<0.01) and LTOK groups(r=-0.71, P<0.01).CONCLUSION: OK does not seem to alter significantly the corneal biomechanical properties, but special care should be taken when analyzing biomechanical parameters influenced by corneal thickness such as amplitude of deformation, ARTh or CBI, because they change significantly after treatment but mainly due to the reduction and pachymetric progression induced by the corneal molding secondary to OK treatment. 展开更多
关键词 overnight orthokeratology corneal biomechanics PACHYMETRY corneal biomechanical index CorVis?ST tomographic biomechanical index
原文传递
Biomechanics of sclera crosslinked using genipin in rabbit 被引量:7
7
作者 Tai-Xiang Liu Zheng Wang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第3期355-360,共6页
AIM:To strengthen the biomechanics of collagen by crosslinking rabbit scleral collagen with genipin to develop a new therapy for preventing myopic progression. METHODS:Ten New Zealand rabbits were treated with 0.5 mmo... AIM:To strengthen the biomechanics of collagen by crosslinking rabbit scleral collagen with genipin to develop a new therapy for preventing myopic progression. METHODS:Ten New Zealand rabbits were treated with 0.5 mmol/L genipin injected into the sub-Tenon's capsule in the right eyes. Untreated contralateral eyes served as the control. The treated area was cut into scleral strips measuring 4.0 mm×10.0 mm for stress-strain measurements(n=5). The remaining five treated eyes were prepared for histological examination.RESULTS:Compared to the untreated scleral strips,the genipin-crosslinked scleral strips showed that the ultimate stress and Young's modulus at 10% strain were increased by the amplitude of 130% and 303% respectively,ultimate strain was decreased by 24%. There had no α-smooth muscle actin(α-SMA)positive cells in control and treated sclera. Histologically,there was no sign of apoptosis in the sclera,choroid,and retina; and no side effects were found in the peripheral cornea and optic nerve adjacent to the treatment area.CONCLUSION:Genipin induced crosslinking of collagen can increase its biomechanical behavior by direct strengthening of the extracellular matrix in rabbit sclera,with no α-SMA expression seen in the myofibroblasts. As there is no evidence of cytotoxicity in the scleral,choroidal,and retinal cells,genipin is likely a promising agent to strengthen the weakened sclera to prevent myopic progression. 展开更多
关键词 GENIPIN CROSSLINKING biomechanicS 巩膜 近视
原文传递
A Biomechanical Comparison of Conventional versus an Anatomic Plate and Compression Bolts for Fixation of Intra-articular Calcaneal Fractures 被引量:6
8
作者 王海立 杨朝旭 +5 位作者 吴战坡 陈伟 张奇 李明 李智勇 张英泽 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2012年第4期571-575,共5页
The purpose of this study was to compare the biomechanical stability obtained by using our technique featured an anatomical plate and compression bolts versus that of the conventional anatomic plate and cancellous scr... The purpose of this study was to compare the biomechanical stability obtained by using our technique featured an anatomical plate and compression bolts versus that of the conventional anatomic plate and cancellous screws in the fixation of intraarticular calcaneal fractures.Eighteen fresh frozen lower limbs of cadavers were used to create a reproductive Sanders type-Ⅲ calcaneal fracture model by using osteotomy.The calcaneus fractures were randomly selected to be fixed either using our anatomical plate and compression bolts or conventional anatomic plate and cancellous screws.Reduction of fracture was evaluated through X radiographs.Each calcaneus was successively loaded at a frequency of 1 Hz for 1000 cycles through the talus using an increasing axial force 20 N to 200 N and 20 N to 700 N,representing the partial weight bearing and full weight bearing,respectively,and then the specimens were loaded to failure.Data extracted from the mechanical testing machine were recorded and used to test for difference in the results with the Wilcoxon signed rank test.No significant difference was found between our fixation technique and conventional technique in displacement during 20-200 N cyclic loading(P=0.06),while the anatomical plate and compression bolts showed a great lower irreversible deformation during 20-700 N cyclic loading(P=0.008).The load achieved at loss of fixation of the constructs for the two groups had significant difference:anatomic plate and compression bolts at 3839.6±152.4 N and anatomic plate and cancellous screws at 3087.3±58.9 N(P=0.008).There was no significant difference between the ultimate displacements.Our technique featured anatomical plate and compression bolts for calcaneus fracture fixation was demonstrated to provide biomechanical stability as good as or better than the conventional anatomic plate and cancellous screws under the axial loading.The study supports the mechanical viability of using our plate and compression bolts for the fixation of calcaneal fracture. 展开更多
关键词 calcaneal fracture ANATOMIC PLATE FIXATION compression BOLTS CONVENTIONAL screws biomechanicAL testing
下载PDF
Biomechanics of the anterior cruciate ligament:Physiology,rupture and reconstruction techniques 被引量:9
9
作者 Christoph Domnick Michael J Raschke Mirco Herbort 《World Journal of Orthopedics》 2016年第2期82-93,共12页
The influences and mechanisms of the physiology,rupture and reconstruction of the anterior cruciate ligament(ACL)on kinematics and clinical outcomes have been investigated in many biomechanical and clinical studies ov... The influences and mechanisms of the physiology,rupture and reconstruction of the anterior cruciate ligament(ACL)on kinematics and clinical outcomes have been investigated in many biomechanical and clinical studies over the last several decades.The knee is a complex joint with shifting contact points,pressures and axes that are affected when a ligament is injured.The ACL,as one of the intra-articular ligaments,has a strong influence on the resulting kinematics.Often,other meniscal or ligamentous injuries accompany ACL ruptures and further deteriorate the resulting kinematics and clinical outcomes.Knowing the surgical options,anatomic relations and current evidence to restore ACL function and considering the influence of concomitant injuries on resulting kinematics to restore full function can together help to achieve an optimal outcome. 展开更多
关键词 biomechanicS ANTERIOR CRUCIATE LIGAMENT joint pressure ANTERIOR CRUCIATE LIGAMENT RUPTURE graft fixation ANTERIOR CRUCIATE LIGAMENT reconstruction
下载PDF
Effect of femtosecond and microkeratome flaps creation on the cornea biomechanics during laser in situ keratomileusis: one year follow-up 被引量:7
10
作者 Qian Sun Zheng-Zheng Deng +2 位作者 Yue-Hua Zhou Jing Zhang Xiao-Yan Peng 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第10期1409-1414,共6页
AIM: To compare the corneal biomechanical outcomes at one year after laser in situ keratomileusis(LASIK) with the flaps created by Ziemer and Moria M2 microkeratome with 110 head and -20 blade.METHODS: Totally 100 eye... AIM: To compare the corneal biomechanical outcomes at one year after laser in situ keratomileusis(LASIK) with the flaps created by Ziemer and Moria M2 microkeratome with 110 head and -20 blade.METHODS: Totally 100 eyes of 50 consecutive patients were enrolled in this prospective study and divided into two groups for corneal flaps created by Ziemer Femto LDV and Moria M2 microkeratome with 110 head and -20 blade.Corneal biomechanical properties including cornea resistance factor(CRF) and cornea hysteresis(CH) were measured before and 1,3,6,12 mo after surgery by ocular response analyzer.Central cornea thickness and corneal flap thickness were measured by optical coherence tomography.RESULTS: The ablation depth(P=0.693),residual corneal thickness(P=0.453),and postoperative corneal curvature(P=0.264) were not significant different between Ziemer group and Moria 110-20 group after surgery.The residual stromal bed thickness,corneal flap thickness,CH and CRF at 12 mo after surgery were significant different between Ziemer group and Moria 110-20 group(P<0.01); Ziemer group gained better corneal biomechanical results.The CRF and CH increased gradually from 1 to12 mo after surgery in Ziemer group,increased from 1 to 6 mo but decreased from 6 to 12 mo in Moria 110-20 group.Both CRF and CH at one year after surgery increased with the increasing of residual cornea thickness; pre-LASIK CRF,CRF also increased with residual stromal bed thickness,while CH decreased with the increasing of pre-LASIK intraocular pressure and cornea flap thickness(P<0.01).CONCLUSION: In one year follow-up,femtosecond laser can provide better cornea flaps with stable cornea biomechanics than mechanical microkeratome. 展开更多
关键词 FEMTOSECOND MICROKERATOME biomechanics keratomileusis
原文传递
Scleral ultrastructure and biomechanical changes in rabbits after negative lens application 被引量:5
11
作者 Xiao Lin Bing-Jie Wang +6 位作者 Yen-Chiao Wang Ren-Yuan Chu Jin-Hui Dai Xing-Tao Zhou Xiao-Mei Qu Hong Liu Hao Zhou 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第3期354-362,共9页
AIM: To address the microstructure and biomechanical changes of the sclera of rabbits after negative lens application by spectacle frame apparatus.METHODS: Five New Zealand rabbits of seven weeks post-natal were treat... AIM: To address the microstructure and biomechanical changes of the sclera of rabbits after negative lens application by spectacle frame apparatus.METHODS: Five New Zealand rabbits of seven weeks post-natal were treated with-8 D lens monocularly over the course of two weeks. Refractive errors and axial length(AXL) were measured at the 1 st, 7 th and 14 th days of the induction period. Ultrastructure of sclera was determined with electron microscopy. Biomechanical properties were tested by an Instron 5565 universal testing machine.RESULTS: Lens-induced(LI) eyes elongated more rapidly compared with fellow eyes with AXL values of 15.56±0.14 and 15.21±0.14 mm(P<0.01). Fibril diameter was significantly smaller in the LI eyes compared with control ones in the inner, middle, and outer layers(inner layer, 63.533 vs 76.467 nm; middle layer, 92.647 vs 123.984 nm; outer layer, 86.999 vs 134.257 nm, P<0.01, respectively). In comparison with control eyes, macrophage-like cells that engulfed fibroblasts, dilated endoplasmic reticulum, and vacuoles in fibroblasts were observed in the inner and middle stroma in the LI eyes. Ultimate stress and Young's modulus were lower in the LI eyes compared with those in the control eyes.CONCLUSION: Negative lens application alters eye growth, and results in axial elongation with changes in scleral ultrastructural and mechanical properties. 展开更多
关键词 否定透镜 兔子 biomechanicS 巩膜 超微结构
原文传递
Corneal biomechanical data and biometric parameters measured with Scheimpflug-based devices on normal corneas 被引量:6
12
作者 Gabor Nemeth Eszter Szalai +3 位作者 Ziad Hassan Agnes Lipecz Zsuzsa Flasko Laszlo Modis 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第2期217-222,共6页
AIM: To analyze the correlations between ocular biomechanical and biometric data of the eye,measured by Scheimpflug-based devices on healthy subjects.METHODS: Three consecutive measurements were carried out using the ... AIM: To analyze the correlations between ocular biomechanical and biometric data of the eye,measured by Scheimpflug-based devices on healthy subjects.METHODS: Three consecutive measurements were carried out using the corneal visualization Scheimpflug technology(Cor Vis ST) device on healthy eyes and the 10 device-specific parameters were recorded.Pentacam HR-derived parameters(corneal curvature radii on the anterior and posterior surfaces;apical pachymetry;corneal volume;corneal aberration data;depth,volume and angle of the anterior chamber) and axial length(AL) from IOLMaster were correlated with the 10 specific CorV is ST parameters.RESULTS: Measurements were conducted in 43 eyes of 43 volunteers(age 61.24±15.72y).The 10 specific Cor Vis ST data showed significant relationships with corneal curvature radii both on the anterior and posterior surface,pachymetric data,root mean square(RMS) data of lower-order aberrations,and posterior RMS of higher-order aberrations and spherical aberration of the posterior cornea.Anterior chamber depth showed a significant relationship,but there were no significant correlations between corneal volume,anterior chamber volume,mean chamber angle or AL and the 10 specific CorV is ST parameters.CONCLUSION: Cor Vis ST-generated parameters are influenced by corneal curvature radii,some corneal RMS data,but corneal volume,anterior chamber volume,chamber angle and AL have no correlation with the biomechan-ical parameters.The parameters measured by CorV is ST seem to refer mostly to corneal properties of the eye. 展开更多
关键词 前面的片断参数 biomechanicS 角膜的可视化 Scheimpflug 技术 眼睛的反应分析器
原文传递
Precontoured buttress plate vs reconstruction plate for acetabulum posterior wall fractures: A biomechanical study 被引量:4
13
作者 Güray Altun Gürsel Saka +2 位作者 Teyfik Demir Fatma Kübra Erbay Elibol Mehmet Or?un Polat 《World Journal of Orthopedics》 2019年第5期219-227,共9页
BACKGROUND The purpose of open reduction and internal fixation of acetabulum posterior wall fractures is to restore anatomical structure and stability of the hip joint, in order to start weight bearing as soon as poss... BACKGROUND The purpose of open reduction and internal fixation of acetabulum posterior wall fractures is to restore anatomical structure and stability of the hip joint, in order to start weight bearing as soon as possible and prevent hip arthrosis; restoration of the anatomy should preserve function of the joint as well. Although "special shaped precontoured plates" have been developed in recent years for surgical treatment of this region, studies comparing the traditional plates with the newly designed precontoured plates are lacking.AIM To evaluate the biomechanical properties of precontoured anatomic buttress and conventional curved reconstruction plates(CCRPs) for posterior wall acetabulum fracture treatment.METHODS Twelve pelvis models were created for testing plate treatment of fracture in the posterior wall of the acetabulum. These 12 pelvis models were used to create 24 hemipelvis models(experimental) by cutting from the sagittal plane and passing over the center of gravity, after which the posterior wall acetabular fractures(of similar type and size) were created. In these experimental models, the right acetabulum was fixed with a 5-hole CCRP, while the left was fixed with a precontoured anatomic buttress plate(PABP). Samples were placed through thetest device and were subjected to static load testing, with a constant testing velocity of 2 mm/min until the load reached 2.3 kN or the acetabular fixation failed. Dynamic tests were also performed with sinusoidal wave load, with a maximal load of 2.3 kN and a load ratio of 0.1.RESULTS The average stiffness values were 460.83 ± 95.47 N/mm for the PABP and 291.99± 118.58 N/mm for the 5-hole CCRP. The precontoured anatomic acetabulum buttress plates had significantly higher rigidity than the CCRPs(P = 0.022). There was a statistically significant difference between the unloaded and 2.3 kN-loaded values of AL(posterosuperior fracture line vertical to the ground surface) and CL(posteroinferior fracture line vertical to the ground surface) parameters for both the PABPs and the 5-hole CCRPs(P = 0.036 and P = 0.045, respectively).According to the static tests, the amount of total displacement was significantly less in the PABPs than in the CCRPs. Comparative analysis of the displacement in the BL(posterior wall fracture line horizontal to the ground) parameter yielded no statistically significant differences between the PABP and the 5-hole CCRPs(P= 0.261).CONCLUSION PABP provides more stable fixation in acetabulum posterior wall fractures than5-hole CCRP, allowing for proximal or distal fracture line screw application without reshaping. 展开更多
关键词 ACETABULAR FRACTURE Anatomical PLATE Precontoured PLATE Posterior wall FRACTURE biomechanicAL study
下载PDF
Effect of Plaque Composition on Biomechanical Performance of a Carotid Stent: Computational Study 被引量:3
14
作者 Xinyang Cui Qingshuai Ren +4 位作者 Zihao Li Kun Peng Gaoyang Li ZhaoyongGu Aike Qiao 《Computer Modeling in Engineering & Sciences》 SCIE EI 2018年第9期455-469,共15页
Clinical application of bare metal stents is constrained by the occurrence of instent restenosis,mainly due to the complex biomechanical environment in the body.Numerical simulation method was used to evaluate the eff... Clinical application of bare metal stents is constrained by the occurrence of instent restenosis,mainly due to the complex biomechanical environment in the body.Numerical simulation method was used to evaluate the effect of plaque composition on stent performance in a carotid artery.CT angiography(CTA)data were used as a reference,and zero-load state of the carotid artery was used to establish a 3D stenotic artery model.Different plaque compositions,calcified and hypo-cellular were defined in Model 1 and Model 2,respectively.Interactions between the stents and arterial tissues within the stent crimping-expansion process were analyzed to explore the effects of plaque composition on the mechanical parameters of carotid stents.Goodman diagram and fatigue safety factor(FSF)were analyzed to explore the effects of plaque composition on fatigue performance of a carotid stent in the stent service process.In the stent crimping-expansion process,the von Mises stress in the stent and the dog-boning ratio in Model 1 were higher than that in Model 2.The calcified plaque prevented the stent from expanding the stenotic vessel to a pre-set diameter.Thus,the risk of rupture in the calcified plaque was higher than that in the hypo-cellular plaque.Plaque also affected the stress/strain in the vessel wall,which was observed to be lower in Model 1 than in Model 2.This indicated that calcified plaque could decrease the stress-induced injury of arterial tissues.Within the stent service process,the stents used in these two models were predicted to not fail under fatigue rupture as calculated by the Goodman diagram.Additionally,the points closer to the fatigue limit were generally observed at the inner bend of the stent crowns.The FSF of the stent in Model 1 was lower than that in Model 2.The stent operating in the presence of calcified plaques suffered high risk of fractures.Reliability and fatigue performance of the stent were found to be associated with plaque composition.Hence,this study may provide stent designers an approach toward enhancing the mechanical reliability of a stent. 展开更多
关键词 PLAQUE COMPOSITION biomechanicAL CAROTID STENT
下载PDF
Corneal biomechanical properties changes after coaxial 2,2-mm microincision and standard 3,0-mm phacoemulsification 被引量:4
15
作者 Zhe Zhang Hua Yu +3 位作者 Hui Dong Li Wang Ya-Ding Jia Su-Hua Zhang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第2期230-234,共5页
AIM: To compare the changes in corneal biomechanics measured by ocular response analyzer(ORA) after 2.2-mm microincision cataract surgery and 3.0-mm standard coaxial phacoemulsification.· METHODS: The prospective... AIM: To compare the changes in corneal biomechanics measured by ocular response analyzer(ORA) after 2.2-mm microincision cataract surgery and 3.0-mm standard coaxial phacoemulsification.· METHODS: The prospective nonrandomized study comprised eyes with cataract that had 2.2-mm coaxial microincision or 3.0-mm standard incision phacoemulsification. The corneal hysteresis(CH), corneal resistance factor(CRF), corneal-compensated intraocular pressure(IOPcc) and Goldmann-correlated intraocular pressure(IOPg) were measured by ORA preoperatively and at 1d, 1-, 2-, 3- and 4-week postoperatively. Results were analyzed and compared between groups.· RESULTS: In both groups, CH decreased in the immediate postoperative period(P <0.05), returned to the preoperative level at one week(P =0.249) in the 2.2-mm group, and at two weeks in the 3.0-mm group(P =0.264);there was no significant change in CRF values. In 2.2-mm group, mean IOPcc and IOPg increased at 1d postoperatively(both P <0.05), and returned to preoperative level at one week(P =0.491 and P =0.923, respectively).In 3.0-mm group, mean IOPcc and IOPg increased at 1d and 1wk postoperatively(P =0.005 and P =0.029,respectively), and returned to preoperative level at 2wk(P =0.347 and P =0.887, respectively).· CONCLUSION: Significant differences between preoperative and postoperative corneal biomechanical values were found for CH, IOPcc and IOPg. But the recovery time courses were different between the twogroups. The 2.2-mm coaxial microincision cataract surgery group seemed recovery faster compared to the3.0-mm standard coaxial phacoemulsification group. 展开更多
关键词 同轴的 microincision 奔流外科 2.2 公里 microincision 角膜的 biomechanical 参数 时间路线
原文传递
Correlation of discoloration and biomechanical properties in porcine sclera induced by genipin 被引量:2
16
作者 Tai-Xiang Liu Xin Luo +2 位作者 Yu-Wei Gu Bin Yang Zheng Wang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2014年第4期621-625,共5页
·AIM: To study the feasibility of using the discoloration to evaluate the biomechanical properties after treating with genipin.·METHODS: Porcine cadaver eyes were treated for30 min with 1.0%(by w/v) genipin.... ·AIM: To study the feasibility of using the discoloration to evaluate the biomechanical properties after treating with genipin.·METHODS: Porcine cadaver eyes were treated for30 min with 1.0%(by w/v) genipin. Untreated samples were used as controls. After treatment, scleral strips of4.0 ×10.0-mm2 were cut. The denaturation temperature(Td) measurement and stress-strain test were performed after taking photograph to analyze the color.·RESULTS: Within 24 h after treating with genipin, the sclera exhibited a bluish color which became deeper with time. And the denaturation temperature also was increased gradually. Compared with untreated groups, at1, 6, 12, 24 and 36 h after treatment, the ultimate stress were increased by 56%, 153%, 173%, 225% and 211%respectively. The Young's modulus at 10% strain also increased by 170%, 246%, 264%, 389% and 288%respectively. There were strong correlation between the discoloration and the biomechanical properties(ΔE-Ultimate stress:R2=0.892, P =0.00; ΔE-Young's modulus:R2=0.602, P =0.00).·CONCLUSION: Genipin could be used to strengthen collagen gradually in a relatively short time span. And the biomechanical properties could be reliably evaluated via simple visible discoloration. 展开更多
关键词 Correlation of DISCOLORATION and biomechanicAL properties in PORCINE SCLERA INDUCED by GENIPIN
原文传递
Effects of Blast Wave-induced Biomechanical Changes on Lung Injury in Rats 被引量:2
17
作者 LIU Wei CHAI Jia Ke +10 位作者 QIN Bin HAN Shao Fang WANG Xiao Teng JIANG Shuai BAI Hai Liang LIU Ling Ying CHANG Yang YUE Xiao Tong WU Yu Shou ZHANG Zi Hao TANG Lang 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2020年第5期338-349,共12页
Objective To observe the dynamic impacts of shock waves on the severity of lung injury in rats with different injury distances.Methods Simulate open-field shock waves;detect the biomechanical effects of explosion sour... Objective To observe the dynamic impacts of shock waves on the severity of lung injury in rats with different injury distances.Methods Simulate open-field shock waves;detect the biomechanical effects of explosion sources at distances of 40,44,and 48 cm from rats;and examine the changes in the gross anatomy of the lungs,lung wet/dry weight ratio,hemoglobin concentration,blood gas analysis,and pathology.Results Biomechanical parameters such as the overpressure peak and impulse were gradually attenuated with an increase in the injury distance.The lung tissue hemorrhage,edema,oxygenation index,and pathology changed more significantly for the 40 cm group than for the 44 and 48 cm groups.The overpressure peak and impulse were significantly higher for the 40 cm group than for the 44 and 48 cm groups(P<0.05 or P<0.01).The animal mortality was significantly higher for the 40 cm group than for the other two groups(41.2%vs.17.8%and 10.0%,P<0.05).The healing time of injured lung tissues for the 40 cm group was longer than those for the 44 and 48 cm groups.Conclusions The effects of simulated open-field shock waves on the severity of lung injuries in rats were correlated with the injury distances,the peak overpressure,and the overpressure impulse. 展开更多
关键词 Shock wave Animal model Open-field blast Lung injury biomechanical effect
下载PDF
Evaluation of corneal topographic,tomographic and biomechanical indices for detecting clinical and subclinical keratoconus:a comprehensive three-device study 被引量:2
18
作者 Zahra Heidari Hassan Hashemi +2 位作者 Mehrdad Mohammadpour Kazem Amanzadeh Akbar Fotouhi 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第2期228-239,共12页
AIM:To evaluate the diagnostic ability of topographic and tomographic indices with Pentacam and Sirius as well as biomechanical parameters with Corvis ST for the detection of clinical and subclinical forms of keratoco... AIM:To evaluate the diagnostic ability of topographic and tomographic indices with Pentacam and Sirius as well as biomechanical parameters with Corvis ST for the detection of clinical and subclinical forms of keratoconus(KCN).METHODS:In this prospective diagnostic test study,70 patients with clinical KCN,79 patients with abnormal findings in topography and tomography maps with no evidence on clinical examination(subclinical KCN),and 68 normal control subjects were enrolled.The accuracy of topographic,tomographic,and biomechanical parameters was evaluated using the area under the receiver operating characteristic curve(AUC)and cross-validation analysis.The Delong method was used for comparing AUCs.RESULTS:In distinguishing KCN from normal,all parameters showed statistically significant differences between the two groups(P<0.001).Indices with the perfect diagnostic ability(AUC≥0.999)were Sirius KCN vertex of back(KVb),Pentacam random forest index(PRFI),Pentacam index of height decentration(IHD),and Corvis integrated tomographic/biomechanical index(TBI).In distinguishing subclinical KCN from normal,Sirius symmetry index of back(SIb;AUC=0.908),Pentacam inferior-superior difference(IS)value(AUC=0.862),PRFI(AUC=0.847),and Corvis TBI(AUC=0.820)performed best.There were no significant differences between the highest AUCs within keratoconic groups(De Long,P>0.05).CONCLUSION:In clinical KCN,all topographic,tomographic,and biomechanical indices have acceptable outcomes in terms of sensitivity and specificity.However,in differentiating subclinical forms of KCN from normal corneas,curvature-based parameters(SIb and IS value)followed by integrated indices(PRFI and TBI)are the most powerful tools for early detection of KCN. 展开更多
关键词 TOPOGRAPHY TOMOGRAPHY biomechanical index KERATOCONUS subclinical keratoconus
原文传递
A Review of the Application of Additive Manufacturing in Prosthetic and Orthotic Clinics from a Biomechanical Perspective 被引量:2
19
作者 Yan Wang Qitao Tan +2 位作者 Fang Pu David Boone Ming Zhang 《Engineering》 SCIE EI 2020年第11期1258-1266,共9页
Prostheses and orthoses are common assistive devices to meet the biomechanical needs of people with physical disabilities.The traditional fabrication approach for prostheses or orthoses is a materialwasting,time-consu... Prostheses and orthoses are common assistive devices to meet the biomechanical needs of people with physical disabilities.The traditional fabrication approach for prostheses or orthoses is a materialwasting,time-consuming,and labor-intensive process.Additive manufacturing(AM)technology has advantages that can solve these problems.Many trials have been conducted in fabricating prostheses and orthoses.However,there is still a gap between the hype and the expected realities of AM in prosthetic and orthotic clinics.One of the key challenges is the lack of a systematic framework of integrated technologies with the AM procedure;another challenge is the need to design a prosthetic or orthotic product that can meet the requirements of both comfort and function.This study reviews the current state of application of AM technologies in prosthesis and orthosis fabrication,and discusses optimal design using computational methods and biomechanical evaluations of product performance.A systematic framework of the AM procedure is proposed,which covers the scanning of affected body parts through to the final designed adaptable product.A cycle of optimal design and biomechanical evaluation of products using finite-element analysis is included in the framework.A mature framework of the AM procedure and sufficient evidence that the resulting products show satisfactory biomechanical performance will promote the application of AM in prosthetic and orthotic clinics. 展开更多
关键词 Additive manufacturing biomechanics of the musculoskeletal system Computational model Prostheses and orthoses 3D printing
下载PDF
Biomechanical characteristics of bone in streptozotocin-induced diabetic rats:An in-vivo randomized controlled experimental study 被引量:2
20
作者 Nektarios Korres Eleftherios Tsiridis +3 位作者 George Pavlou Athanasios Mitsoudis Despina N Perrea Aristedes B Zoumbos 《World Journal of Orthopedics》 2013年第3期124-129,共6页
AIM: To investigate the in vivo effects of type Ⅰdiabetes on the mechanical strength of tibial bone in a rodent model.METHODS: The biomechanical effect of diabetes on the structural integrity of the tibia in streptoz... AIM: To investigate the in vivo effects of type Ⅰdiabetes on the mechanical strength of tibial bone in a rodent model.METHODS: The biomechanical effect of diabetes on the structural integrity of the tibia in streptozotocin induced diabetic Wistar rats was analysed. Induction of diabetes was achieved by an intra-peritoneal injection and confirmed by measuring serial blood glucose levels(> 150 mg/d L). After 8 wk the tibiae were harvested and compared to a control group. Biomechanical analysis of harvested tibiae was performed using a threepoint bending technique on a servo hydraulic MTS 858 MiniB ionix frame. Maximum force applied to failure(N), stiffness(N × mm) and energy absorbed(N/mm) were recorded and plotted on load displacement curves. A displacement control loading mode of 1 mm/min was selected to simulate quasi-static loading conditions. Measurements from load-displacement curves were directly compared between groups.RESULTS: Fourteen streptozotocin induced diabetic Wistar rats were compared against nineteen non-diabetic controls. An average increase of 155.2 g in body weight was observed in the control group compared with only 5 g in the diabetic group during the experimental study period. Levels of blood glucose increased to 440.25 mg/d L in the diabetic group compared to 116.62 mg/d L in the control group.The biomechanical results demonstrate a highly significant reduction in the maximum load to failure from 69.5 N to 58 N in diabetic group compared to control(P = 0.011). Energy absorption to fracture was reduced from 28.2 N in the control group to 23.5 N in the diabetic group(P = 0.082). No significant differences were observed between the groups for bending stiffness.CONCLUSION: Streptozotocin-induced diabetes in rodents reduces the maximum force and energy absorption to failure of bone, suggesting a predisposition for fracture risk. 展开更多
关键词 STREPTOZOTOCIN RODENT BONE biomechanicS
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部