期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Exercise-induced irisin in bone and systemic irisin administration reveal new regulatory mechanisms of bone metabolism 被引量:23
1
作者 Jin Zhang Paloma Valverde +9 位作者 Xiaofang Zhu Dana Murray Yuwei Wu Liming Yu Hua Jiang Michel M Dard Jin Huang Zhiwei Xu Qisheng Tu Jake Chen 《Bone Research》 SCIE CAS CSCD 2017年第1期49-62,共14页
Irisin is a polypeptide hormone derived from the proteolytic cleavage of fibronectin-type III domaincontaining 5(FNDC5) protein. Once released to circulation upon exercise or cold exposure, irisin stimulates browning ... Irisin is a polypeptide hormone derived from the proteolytic cleavage of fibronectin-type III domaincontaining 5(FNDC5) protein. Once released to circulation upon exercise or cold exposure, irisin stimulates browning of white adipose tissue(WAT) and uncoupling protein 1(UCP1) expression, leading to an increase in total body energy expenditure by augmented UCP1-mediated thermogenesis. It is currently unknown whether irisin is secreted by bone upon exercise or whether it regulates bone metabolism in vivo. In this study, we found that 2 weeks of voluntary wheel-running exercise induced high levels of FNDC5 messenger RNA as well as FNDC5/irisin protein expression in murine bone tissues. Increased immunoreactivity due to exercise-induced FNDC5/irisin expression was detected in different regions of exercised femoral bones,including growth plate, trabecular bone, cortical bone, articular cartilage, and bone–tendon interface. Exercise also increased expression of osteogenic markers in bone and that of UCP1 in WAT, and led to bodyweight loss. Irisin intraperitoneal(IP) administration resulted in increased trabecular and cortical bone thickness and osteoblasts numbers, and concurrently induced UCP1 expression in subcutaneous WAT. Lentiviral FNDC5 IP administration increased cortical bone thickness. In vitro studies in bone cells revealed irisin increases osteoblastogenesis and mineralization, and inhibits receptor activator of nuclear factor-k B ligand(RANKL)-induced osteoclastogenesis. Taken together, our findings show that voluntary exercise increases irisin production in bone, and that an increase in circulating irisin levels enhances osteogenesis in mice. 展开更多
关键词 Exercise-induced irisin in bone and systemic irisin administration reveal new regulatory mechanisms of bone metabolism bone
下载PDF
A multiscale 3D finite element analysis of fluid/solute transport in mechanically loaded bone 被引量:2
2
作者 Lixia Fan Shaopeng Pei +1 位作者 X Lucas Lu Liyun Wang 《Bone Research》 SCIE CAS CSCD 2016年第3期154-163,共10页
The transport of fluid, nutrients, and signaling molecules in the bone lacunar–canalicular system(LCS) is critical for osteocyte survival and function. We have applied the fluorescence recovery after photobleaching(F... The transport of fluid, nutrients, and signaling molecules in the bone lacunar–canalicular system(LCS) is critical for osteocyte survival and function. We have applied the fluorescence recovery after photobleaching(FRAP) approach to quantify load-induced fluid and solute transport in the LCS in situ, but the measurements were limited to cortical regions 30–50 μm underneath the periosteum due to the constrains of laser penetration. With this work, we aimed to expand our understanding of load-induced fluid and solute transport in both trabecular and cortical bone using a multiscaled image-based finite element analysis(FEA)approach. An intact murine tibia was first re-constructed from micro CT images into a three-dimensional(3D)linear elastic FEA model, and the matrix deformations at various locations were calculated under axial loading. A segment of the above 3D model was then imported to the biphasic poroelasticity analysis platform(FEBio) to predict load-induced fluid pressure fields, and interstitial solute/fluid flows through LCS in both cortical and trabecular regions. Further, secondary flow effects such as the shear stress and/or drag force acting on osteocytes, the presumed mechano-sensors in bone, were derived using the previously developed ultrastructural model of Brinkman flow in the canaliculi. The material properties assumed in the FEA models were validated against previously obtained strain and FRAP transport data measured on the cortical cortex.Our results demonstrated the feasibility of this computational approach in estimating the fluid flux in the LCS and the cellular stimulation forces(shear and drag forces) for osteocytes in any cortical and trabecular bone locations, allowing further studies of how the activation of osteocytes correlates with in vivo functional bone formation. The study provides a promising platform to reveal potential cellular mechanisms underlying the anabolic power of exercises and physical activities in treating patients with skeletal deficiencies. 展开更多
关键词 A multiscale 3D finite element analysis of fluid/solute transport in mechanically loaded bone FIGURE
下载PDF
Role and mechanism of action of leucine-rich repeat kinase 1 in bone 被引量:2
3
作者 Weirong Xing Helen Goodluck +1 位作者 Canjun Zeng Subburaman Mohan 《Bone Research》 SCIE CAS CSCD 2017年第1期14-26,共13页
Leucine-rich repeat kinase 1 (LRRK1) plays a critical role in regulating cytoskeletal organization, osteoclast activity, and bone resorption with little effect on bone formation parameters. Deficiency of Lrrk1 in mice... Leucine-rich repeat kinase 1 (LRRK1) plays a critical role in regulating cytoskeletal organization, osteoclast activity, and bone resorption with little effect on bone formation parameters. Deficiency of Lrrk1 in mice causes a severe osteopetrosis in the metaphysis of the long bones and vertebrae bones, which makes LRRK1 an attractive alternative drug target for the treatment of osteoporosis and other high-turnover bone diseases.This review summarizes recent advances on the functions of the Lrrk1-related family members, Lrrk1deficiency-induced skeletal phenotypes, LRRK1 structure–function, potential biological substrates and interacting proteins, and the mechanisms of LRRK1 action in osteoclasts. 展开更多
关键词 GENE Role and mechanism of action of leucine-rich repeat kinase 1 in bone
下载PDF
Osteocyte pericellular and perilacunar matrices as markers of bone-implant mechanical integrity
4
作者 ReMY GAUTHIER HeLÈNE FOLLET +5 位作者 ANA-MARIA TRUNFIO-SFARGHIU DELPHINE FARLAY NINA ATTIK SYLVAIN MEILLE JeRÔME CHEVALIER DAVID MITTON 《BIOCELL》 SCIE 2022年第10期2209-2216,共8页
To develop durable bone healing strategies through improved control of bone repair,it is of critical importance to understand the mechanisms of bone mechanical integrity when in contact with biomaterials and implants.... To develop durable bone healing strategies through improved control of bone repair,it is of critical importance to understand the mechanisms of bone mechanical integrity when in contact with biomaterials and implants.Bone mechanical integrity is defined here as the adaptation of structural properties of remodeled bone in regard to an applied mechanical loading.Accordingly,the authors present why future investigations in bone repair and regeneration should emphasize on the matrix surrounding the osteocytes.Osteocytes are mechanosensitive cells considered as the orchestrators of bone remodeling,which is the biological process involved in bone homeostasis.These bone cells are trapped in an interconnected porous network,the lacunocanalicular network,which is embedded in a bone mineralized extracellular matrix.As a consequence of an applied mechanical loading,the bone deformation results in the deformation of this lacunocanalicular network inducing a shift in interstitial fluid pressure and velocity,thus resulting in osteocyte stimulation.The material environment surrounding each osteocyte,the so called perilacunar and pericellular matrices properties,define its mechanosensitivity.While this mechanical stimulation pathway is well known,the laws used to predict bone remodeling are based on strains developing at a tissue scale,suggesting that these strains are related to the shift in fluid pressure and velocity at the lacunocanalicular scale.While this relationship has been validated through observation in healthy bone,the fluid behavior at the bone-implant interface is more complex.The presence of the implant modifies fluid behavior,so that for the same strain at a tissue scale,the shift in fluid pressure and velocity will be different than in a healthy bone tissue.In that context,new markers for bone mechanical integrity,considering fluid behavior,have to be defined.The viewpoint exposed by the authors indicates that the properties of the pericellular and the perilacunar matrices have to be systematically investigated and used as structural markers of fluid behavior in the course of bone biomaterial development. 展开更多
关键词 bone mechanical integrity OSTEOCYTES Pericellular Perilacunar MECHANOSENSITIVITY
下载PDF
A New Volumetric Parameter for a Comparative Finite-Element Analysis of a Six- or Four-Implant Mandibular Total-Arch Rehabilitation
5
作者 Alfredo Natali Enrico Bertocchi +3 位作者 Andrea Baldini Giuseppe Antonio Mulas Matteo Martinolli Bortolini Sergio 《Open Journal of Stomatology》 2016年第1期12-21,共10页
In a full-arch implant rehabilitation ad modum Branemark, the distribution of stress and strain in mandibular bone is influenced by the type, number and position of implants used. In particular, the biomechanical beha... In a full-arch implant rehabilitation ad modum Branemark, the distribution of stress and strain in mandibular bone is influenced by the type, number and position of implants used. In particular, the biomechanical behaviour of the bone structure after complete osseointegration depends on the load transferred to the bone by each fixture. In this study, a finite-element analysis of two models was performed. Models of an all-on-four configuration and a six-implant configuration were compared in a worst-case scenario. A new V parameter is presented to aid the quantitative and comparative analysis of the all-on-four and six-implant configurations. The influence of orthotropy was also investigated, and a geometric change in the all-on-four configuration is presented. 展开更多
关键词 Finite-Element Analysis Oral Implants All-on-Four Configuration Six-Implant Configuration bone mechanics Comparative Analysis
下载PDF
On the material dependency of peri-implant morphology and stability in healing bone
6
作者 Stefan Bruns Diana Krüger +7 位作者 Silvia Galli D.C.Florian Wieland Jorg U.Hammel Felix Beckmann Ann Wennerberg Regine Willumeit-Romer Berit Zeller-Plumhoff Julian Moosmann 《Bioactive Materials》 SCIE CSCD 2023年第10期155-166,共12页
The microstructural architecture of remodeled bone in the peri-implant region of screw implants plays a vital role in the distribution of strain energy and implant stability.We present a study in which screw implants ... The microstructural architecture of remodeled bone in the peri-implant region of screw implants plays a vital role in the distribution of strain energy and implant stability.We present a study in which screw implants made from titanium,polyetheretherketone and biodegradable magnesium-gadolinium alloys were implanted into rat tibia and subjected to a push-out test four,eight and twelve weeks after implantation.Screws were 4 mm in length and with an M2 thread.The loading experiment was accompanied by simultaneous three-dimensional imaging using synchrotron-radiation microcomputed tomography at 5μm resolution.Bone deformation and strains were tracked by applying optical flow-based digital volume correlation to the recorded image sequences.Implant stabilities measured for screws of biodegradable alloys were comparable to pins whereas non-degradable biomaterials experienced additional mechanical stabilization.Peri-implant bone morphology and strain transfer from the loaded implant site depended heavily on the biomaterial utilized.Titanium implants stimulated rapid callus formation displaying a consistent monomodal strain profile whereas the bone volume fraction in the vicinity of magnesium-gadolinium alloys exhibited a minimum close to the interface of the implant and less ordered strain transfer.Correlations in our data suggest that implant stability benefits from disparate bone morphological properties depending on the biomaterial utilized.This leaves the choice of biomaterial as situational depending on local tissue properties. 展开更多
关键词 Biodegradable implant materials bone mechanical testing Implant stability Synchrotron micro-computed tomography imaging Digital volume correlation
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部