Objective:To explore the curative effect of Carisolv,a minimally invasive caries removal technique and traditional mechanical caries removal treatment on children’s dental caries.Methods:A total of 97 children with d...Objective:To explore the curative effect of Carisolv,a minimally invasive caries removal technique and traditional mechanical caries removal treatment on children’s dental caries.Methods:A total of 97 children with dental caries who were treated in the Department of Stomatology in Affiliated Hospital of Chifeng University,Chifeng from September 2017 to May 2019 were selected and recruited as the research subjects.They were divided into two groups by random number table method.Forty-nine individuals were assigned in the control group while the remaining 48 individuals in the observation group.The control group was treated with traditional mechanical caries removal method,and the observation group was treated with minimally invasive caries removal technique,i.e.Carisolv.Both groups were followed up for six months.The degree of pain,recovery time of dental function and complications after six months of treatment were observed in the two groups of children.Results:During the treatment,compared with the control group,the children in the observation group experienced lower degree of pain and had shorter recovery time of dental function.After six months of treatment,the incidence of complications in the observation group was lower than that in the control group.The difference was statistically significant(P<0.05).Conclusion:Compared with traditional mechanical caries removal method,Carisolv,a minimally invasive caries removal technique could reduce the pain of children during the treatment process,shorten the time to restore dental function,reduce the occurrence of complications,and had a better therapeutic effect in treating children’s dental caries.展开更多
Purpose: To evaluate the 3-year efficiency and safety of XEN<sup>®</sup> 45 gel stent implantation in a heterogenous group of open angle glaucoma patients. Methods: In this prospective, non-randomized...Purpose: To evaluate the 3-year efficiency and safety of XEN<sup>®</sup> 45 gel stent implantation in a heterogenous group of open angle glaucoma patients. Methods: In this prospective, non-randomized observational study we identified patients who had undergone either stand-alone XEN<sup>®</sup> implantation (XEN solo) or XEN<sup>®</sup> implantation in combination with phacoemulsification (XEN combi). All patients who had undergone an implantation during the period 01.04.17-31.10.19 at the Department of Ophthalmology, Drammen Hospital, Norway, were asked to participate. Success was defined as IOP between 5 - 18 mmHg and 20% pressure reduction without medications. Qualified success required the same pressure interval and reduction but allowed medications. The procedure was deemed as failure if pressure requirements were not met, vision was reduced to light perception or worse, or if there was a converion to secondary glaucoma surgery. Results: Out of 115 patients and 133 eyes identified, 87 patients and 99 eyes consented to participate. All patients were Caucasians with a mean age of 73.6 years. The study had a mean (range) follow-up of 38.9 (28 - 54) months. The mean medicated baseline (SD) was reduced from 22.6 (7.9) mmHg on 3.2 (1.1) medications to 14.2 (5.6) mmHg on 1.4 (1.6) medications. Success and qualified success were achieved in 22.2% and 21.2%, respectively. Needling was performed in 34 eyes. Conclusion: XEN<sup>®</sup> 45 gel stent implantation is a safe procedure, offering a significantly lower IOP and number of medications in a subset of patients with open angle glaucoma.展开更多
Our aim was to report quality of life(QOL) outcomes following Xen45 Gel Stent implantation surgery in patients suffering with primary open angle glaucoma(POAG). A retrospective analysis was performed on all patients w...Our aim was to report quality of life(QOL) outcomes following Xen45 Gel Stent implantation surgery in patients suffering with primary open angle glaucoma(POAG). A retrospective analysis was performed on all patients who had Xen45 implantation surgery during a 2-year period(Jun, 2016-Apr, 2018). Of 52 consecutive patients were included with a total of 58 eyes being operated on. QOL was compared both pre-operatively and 6 weeks postoperatively using the GQL-15 questionnaire. There was an overall improvement in GQL-15 summary scores for our patient group. All item scores showed either no change or some degree of improvement. The Xen45 Gel Stent Implant is a promising new intervention which has shown improved QOL scores in our patient group. Further, higher power studies are now needed to compare the Xen45 to trabeculectomy(TE), which is currently the gold standard.展开更多
文摘Objective:To explore the curative effect of Carisolv,a minimally invasive caries removal technique and traditional mechanical caries removal treatment on children’s dental caries.Methods:A total of 97 children with dental caries who were treated in the Department of Stomatology in Affiliated Hospital of Chifeng University,Chifeng from September 2017 to May 2019 were selected and recruited as the research subjects.They were divided into two groups by random number table method.Forty-nine individuals were assigned in the control group while the remaining 48 individuals in the observation group.The control group was treated with traditional mechanical caries removal method,and the observation group was treated with minimally invasive caries removal technique,i.e.Carisolv.Both groups were followed up for six months.The degree of pain,recovery time of dental function and complications after six months of treatment were observed in the two groups of children.Results:During the treatment,compared with the control group,the children in the observation group experienced lower degree of pain and had shorter recovery time of dental function.After six months of treatment,the incidence of complications in the observation group was lower than that in the control group.The difference was statistically significant(P<0.05).Conclusion:Compared with traditional mechanical caries removal method,Carisolv,a minimally invasive caries removal technique could reduce the pain of children during the treatment process,shorten the time to restore dental function,reduce the occurrence of complications,and had a better therapeutic effect in treating children’s dental caries.
文摘Purpose: To evaluate the 3-year efficiency and safety of XEN<sup>®</sup> 45 gel stent implantation in a heterogenous group of open angle glaucoma patients. Methods: In this prospective, non-randomized observational study we identified patients who had undergone either stand-alone XEN<sup>®</sup> implantation (XEN solo) or XEN<sup>®</sup> implantation in combination with phacoemulsification (XEN combi). All patients who had undergone an implantation during the period 01.04.17-31.10.19 at the Department of Ophthalmology, Drammen Hospital, Norway, were asked to participate. Success was defined as IOP between 5 - 18 mmHg and 20% pressure reduction without medications. Qualified success required the same pressure interval and reduction but allowed medications. The procedure was deemed as failure if pressure requirements were not met, vision was reduced to light perception or worse, or if there was a converion to secondary glaucoma surgery. Results: Out of 115 patients and 133 eyes identified, 87 patients and 99 eyes consented to participate. All patients were Caucasians with a mean age of 73.6 years. The study had a mean (range) follow-up of 38.9 (28 - 54) months. The mean medicated baseline (SD) was reduced from 22.6 (7.9) mmHg on 3.2 (1.1) medications to 14.2 (5.6) mmHg on 1.4 (1.6) medications. Success and qualified success were achieved in 22.2% and 21.2%, respectively. Needling was performed in 34 eyes. Conclusion: XEN<sup>®</sup> 45 gel stent implantation is a safe procedure, offering a significantly lower IOP and number of medications in a subset of patients with open angle glaucoma.
文摘Our aim was to report quality of life(QOL) outcomes following Xen45 Gel Stent implantation surgery in patients suffering with primary open angle glaucoma(POAG). A retrospective analysis was performed on all patients who had Xen45 implantation surgery during a 2-year period(Jun, 2016-Apr, 2018). Of 52 consecutive patients were included with a total of 58 eyes being operated on. QOL was compared both pre-operatively and 6 weeks postoperatively using the GQL-15 questionnaire. There was an overall improvement in GQL-15 summary scores for our patient group. All item scores showed either no change or some degree of improvement. The Xen45 Gel Stent Implant is a promising new intervention which has shown improved QOL scores in our patient group. Further, higher power studies are now needed to compare the Xen45 to trabeculectomy(TE), which is currently the gold standard.