期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Novel Cascade Refrigeration Cycle for Cold Supply Chain of COVID-19 Vaccines at Ultra-Low Temperature -80°C Using Ethane (R170) Based Hydrocarbon Pair
1
作者 Tarek A. Mouneer Abdelrahman M. Elshaer Mohamed H. Aly 《World Journal of Engineering and Technology》 2021年第2期309-336,共28页
Several media report highlight on that the pharmaceutical companies require ultra-low temperatures -80<span style="white-space:nowrap;">°</span>C to transport and store its COVID-19 vaccines... Several media report highlight on that the pharmaceutical companies require ultra-low temperatures -80<span style="white-space:nowrap;">°</span>C to transport and store its COVID-19 vaccines. This research presents the thermodynamic analysis on cascade refrigeration system (CRS) with several refrigerant pairs which are R32/R170, R123/R170, R134a/R170, R404A/R170, R407c/R170, R410/R170, and the hydrocarbon (HC) refrigerant pair Propane/Ethane, namely R290/R170. Besides, the results of R22/R170 pair, which is not recommended to be used due to phase out of R22 as per Montréal Protocol, are included as base case to compare the novel hydrocarbon pairs in CRS and the old trend of refrigerant pairs. Thermodynamic properties of all these pairs were investigated and compared under different intermediate temperature used in CRS heat exchanger, which thermally connected both the Low and High temperature cycles (LTC) and (HTC). By applying the first law of thermodynamics, the coefficients of performance (COPs) and the specific power consumptions (SPC) in kW/TR are presented and compared. In addition, by applying the second law of thermodynamics the exergetic efficiencies were estimated. The results reveal the promising opportunity of using the HC pair (R290/R170). The minimum SPC in kW/TR is recorded for the pair R123/R170. One the other hand, the highest exegetic efficiency values are observed to be 40%, 38%, and 35% for the pairs R123/R170, R290/R170, and R134/R170, respectively. This research concludes that the HC pair (R290/R170) is highly recommended for CRS applications either to transport the COVID-19 or store it in cold storage rooms in hospitals and clinics. All precautionary measures should be carefully applied in design and operation of HC pair (R290/R170) due to its flammability hazard. 展开更多
关键词 cascade refrigeration Cold Supply Chain COVID-19 Vaccine Ultra-Low Temperature -80°C Hydrocarbon Refrigerants Refrigerant Pair
下载PDF
Experimental Investigation of the Ejector Refrigeration Cycle for Cascade System Application 被引量:1
2
作者 HAO Xinyue GAO Neng +3 位作者 CHEN Guangming VOLOVYK Oleksii WANG Xuehui XUAN Yongmei 《Journal of Thermal Science》 SCIE EI CAS CSCD 2022年第5期1476-1486,共11页
Ejector refrigeration cycle(ERC)with advantages of simple structure and low cost holds great application potential in cascade/hybrid cycles to improve the overall system performance by removing or recovering the heat ... Ejector refrigeration cycle(ERC)with advantages of simple structure and low cost holds great application potential in cascade/hybrid cycles to improve the overall system performance by removing or recovering the heat from the main cycle.In this paper,a theoretical and experimental investigation of the ERC as a part of a cascade system was carried out.The operating parameters were optimized.The experimental ERC test rig was designed,developed and investigated at high evaporating temperatures and wide ranges of operating conditions.The influence of operating conditions on the efficiency of the ejector and ERC was analyzed.Experimental results and analysis in this study can be helpful for the application and operating condition optimization of ERC in cascade/hybrid refrigeration systems. 展开更多
关键词 EJECTOR ejector refrigeration cycle cascade refrigeration system EXPERIMENT PERFORMANCE
原文传递
Experimental study on a -60 °C cascade refrigerator with dual running mode 被引量:1
3
作者 Xiu-fang LIU Jiong-hui LIU +2 位作者 Hong-li ZHAO Qiao-yu ZHANG Juan-li MA 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2012年第5期375-381,共7页
In this study,an experimental setup is designed and built to investigate the feasibility and performance of the proposed dual-mode cascade refrigeration cycle.The apparatus can be operated in two modes:dual-stage mode... In this study,an experimental setup is designed and built to investigate the feasibility and performance of the proposed dual-mode cascade refrigeration cycle.The apparatus can be operated in two modes:dual-stage mode and single-stage mode such that the low temperature cycle(LTC) can be operated together with the high temperature cycle(HTC) or can run independently.Experimental results validate the feasibility of independent operation of LTC.The performance of the independent operation of LTC mode is theoretically investigated using experimental data as bases.Detailed suggestions are made for the improvement of the coefficient of performance(COP) of the experimental system.Theoretically,high COP of the cycle provides excellent application for the presented refrigeration cycle. 展开更多
关键词 cascade refrigeration DUAL-MODE REGENERATOR Optimization EFFECTIVENESS
原文传递
上一页 1 下一页 到第