Influence of sub-bandgap illumination on space charge distribution in CdZnTe detector
1
作者 Rongrong Guo Jinhai Lin +4 位作者 Lili Liu Shiwei Li Chen Wang Feibin Xiong Haijun Lin 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第3期378-385,共8页
The space charge accumulation in CdZnTe crystals seriously affects the performance of high-flux pulse detectors.The influence of sub-bandgap illumination on the space charge distribution and device performance in CdZn... The space charge accumulation in CdZnTe crystals seriously affects the performance of high-flux pulse detectors.The influence of sub-bandgap illumination on the space charge distribution and device performance in CdZnTe crystals were studied theoretically by Silvaco TCAD software simulation.The sub-bandgap illumination with a wavelength of 890 nm and intensity of 8×10−8 W/cm2 were used in the simulation to explore the space charge distribution and internal electric field distribution in CdZnTe crystals.The simulation results show that the deep level occupation faction is manipulated by the sub-bandgap illumination,thus space charge concentration can be reduced under the bias voltage of 500 V.A flat electric field distribution is obtained,which significantly improves the charge collection efficiency of the CdZnTe detector.Meanwhile,premised on the high resistivity of CdZnTe crystal,the space charge concentration in the crystal can be further reduced with the wavelength of 850 nm and intensity of 1×10−7 W/cm2 illumination.The electric field distribution is flatter and the carrier collection efficiency of the device can be improved more effectively. 展开更多
关键词 cdznte detector sub-bandgap illumination space charge charge collection efficiency
原文传递
Research of CdZnTe detector based portable energy dispersive spectrometer 被引量:3
2
作者 CHENG Cheng WEI Yong-Bo XU Hui-Chao ZHAO Cui-Lan ZHANG Jin-Zhou PU Shi-Jie JIANG Da-Zhen 《Nuclear Science and Techniques》 SCIE CAS CSCD 2006年第2期106-112,共7页
A kind of excellent CdZnTe crystal has been grown in Yinnel Tech, Inc. in recent years. Based on these CdZnTe crystals and some new techniques, a portable energy-dispersive spectrometer has been constructed which has ... A kind of excellent CdZnTe crystal has been grown in Yinnel Tech, Inc. in recent years. Based on these CdZnTe crystals and some new techniques, a portable energy-dispersive spectrometer has been constructed which has yielded good results. CdZnTe detector has a 3% relative resolution in high-energy field and can detect gamma rays at room temperature. An integrated circuit based on preamplifier and shaping amplifier chips is connected to the detector. Voltage pulses are transformed into digital signals in MCA (multichannel analyzer) and are then transmitted to com- puter via USB bus. Data process algorithms are improved in this spectrometer. Fast Fourier transform (FFT) and nu- merical differentiation (ND) are used in energy peak’s searching program. Sampling-based correction technique is used in X-ray energy calibration. Modified Gaussian-Newton algorithm is a classical method to solve nonlinear curve fitting problems, and it is used to compute absolute intensity of each detected characteristic line. 展开更多
关键词 cdznte探测器 前置放大器 能量弥散光谱仪 光谱分析
下载PDF
Simulation of the anode structure for capacitive Frisch grid CdZnTe detectors 被引量:2
3
作者 MIN Jiahua SHI Zhubin +4 位作者 QIAN Yongbiao SANG Wenbin ZHAO Hengyu TENG Jianyong LIU Jishan 《Nuclear Science and Techniques》 SCIE CAS CSCD 2009年第1期46-50,共5页
CdZnTe(CZT)capacitive Frisch grid detectors can achieve a higher detecting resolution.The anode structure might have an important role in improving the weighting potential distribution of the detectors.In this paper, ... CdZnTe(CZT)capacitive Frisch grid detectors can achieve a higher detecting resolution.The anode structure might have an important role in improving the weighting potential distribution of the detectors.In this paper, four anode structures of capacitive Frisch grid structures have been analyzed with FE simulation,based on a 3-dimensional weighting potential analysis.The weighting potential distributions in modified anode devices(Model B, C and D)are optimized compared with a square device(Model A).In model C and D,the abrupt weighting potential can be well modified.However,with increased radius of the circular electrode in Model C the weighting potential platform away from the anode becomes higher and higher and in Model D,the weighting potential does not vary too much. 展开更多
关键词 cdznte探测器 性能 重离子 原子核 核电子学
下载PDF
Characteristics of a prototype CdZnTe detector 被引量:3
4
作者 XU Huichao CHENG Cheng +2 位作者 ZHAO Cuilan ZHANG Jinzhou PU Shijie 《Nuclear Science and Techniques》 SCIE CAS CSCD 2007年第6期358-361,共4页
Cadmium zinc telluride(CZT)is a preferred material for X-ray and gamma-ray detector.Thanks to the relatively high atomic number,high density and wide band-gap,CZT detector possesses sharp energy resolution and high de... Cadmium zinc telluride(CZT)is a preferred material for X-ray and gamma-ray detector.Thanks to the relatively high atomic number,high density and wide band-gap,CZT detector possesses sharp energy resolution and high detection efficiency without cryogenic cooling.We have developed a CdZnTe detector with an energy resolution of 3.45%(FWHM)at 59.54 keV at room temperature,and it is used for X-ray fluorescence analysis.In this paper, leakage current,energy resolution and long term stability of the CZT detector are discussed. 展开更多
关键词 粒子探测 探测器 形状 稳定性
下载PDF
Analog rise-time discriminator for CdZnTe detector
5
作者 Chuan-Hao Hu Guo-Qiang Zeng +4 位作者 Liang-Quan Ge Shi-Long Wei Jian Yang Qiang Li Hong-Zhi Li 《Nuclear Science and Techniques》 SCIE CAS CSCD 2017年第4期59-65,共7页
Due to variable time for charge collection,energy resolution of nuclear detectors declines,especially compound semiconductor detectors like cadmium zinc telluride(CdZnTe) detector.To solve this problem,an analog rise-... Due to variable time for charge collection,energy resolution of nuclear detectors declines,especially compound semiconductor detectors like cadmium zinc telluride(CdZnTe) detector.To solve this problem,an analog rise-time discriminator based on charge comparison principle is designed.The reference charge signal after attenuation is compared with the deconvoluted and delayed current signal.It is found that the amplitude of delayed current signal is higher than that of the reference charge signal when rise time of the input signal is shorter than the discrimination time,thus generating gating signal and triggering DMCA(digital multi-channel analyzer) to receive the total integral charge signal.When rise time of the input signal is longer than discrimination time,DMCA remains inactivated and the corresponding total integral charge signal is abandoned.Test results show that combination of the designed rise-time discriminator and DMCA can reduce hole tailing of CdZnTe detector significantly.Energy resolution of the system is 0.98%@662 keV,and it is still excellent under high counting rates. 展开更多
关键词 ANALOG rise-time DISCRIMINATOR cdznte detector Charge comparison PRINCIPLE
下载PDF
A test device for isotopic γ-ray imaging with CdZnTe detector
6
作者 HUANG Jin WANG Xiaolian +1 位作者 ZENG Hui XU Zizong 《Nuclear Science and Techniques》 SCIE CAS CSCD 2007年第2期107-110,共4页
A test device for isotopic γ-ray imaging, which consists of an isotope γ-ray source, a CdZnTe γ-ray spec- trometer and other auxiliary equipment, is studied here. Compared with the conventional X-ray, the isotope ... A test device for isotopic γ-ray imaging, which consists of an isotope γ-ray source, a CdZnTe γ-ray spec- trometer and other auxiliary equipment, is studied here. Compared with the conventional X-ray, the isotope γ-ray, which is utilized in this project, has its own advantages in imaging. Furthermore, with a room-temperature high-energy-resolution CdZnTe detector and a modern imaging processing technique, this device is capable of effec- tively suppressing the background and gaining more information, thus it can obtain a better image than conventional X-ray devices. In the experiment of PCB imaging, all soldered points and chip components are sharply demonstrated. 展开更多
关键词 同位素γ射线源 成像 检测装置 cdznte探测器
下载PDF
Design of a Low-Noise Front-End Readout Circuit for CdZnTe Detectors
7
作者 Bo Gan Tingcun Wei +2 位作者 Wu Gao Huiming Zeng Yann Hu 《Journal of Signal and Information Processing》 2013年第2期123-128,共6页
In this paper, the design of a novel low-noise front-end readout circuit for Cadmium zinc telluride (CdZnTe) X-ray and γ-ray detectors is described. The front-end readout circuits include the charge sensitive amplifi... In this paper, the design of a novel low-noise front-end readout circuit for Cadmium zinc telluride (CdZnTe) X-ray and γ-ray detectors is described. The front-end readout circuits include the charge sensitive amplifier (CSA) and the CR-RC shaper is implemented in TSMC 0.35 μm mixed-signal CMOS technology. The die size of the prototype chip is 4.9 mm × 2.2 mm. The simulation results show that, the noise performance is 46 electrons + 10 electrons/pF, and power consumption is 1.65 mW per channel. 展开更多
关键词 cdznte detector Low Noise FRONT-END READOUT CMOS
下载PDF
Design and performances of a low-noise and radiation-hardened readout ASIC for CdZnTe detectors 被引量:1
8
作者 甘波 魏廷存 +1 位作者 高武 胡永才 《Journal of Semiconductors》 EI CAS CSCD 2016年第6期177-183,共7页
In this paper,we present the design and performances of a low-noise and radiation-hardened front-end readout application specific integrated circuit(ASIC) dedicated to CdZnTe detectors for a hard X-ray imager in spa... In this paper,we present the design and performances of a low-noise and radiation-hardened front-end readout application specific integrated circuit(ASIC) dedicated to CdZnTe detectors for a hard X-ray imager in space applications.The readout channel is comprised of a charge sensitive amplifier,a CR-RC shaping amplifier,an analog output buffer,a fast shaper,and a discriminator.An 8-channel prototype ASIC is designed and fabricated in TSMC 0.35-μm mixed-signal CMOS technology,the die size of the prototype chip is 2.2×2.2 mm^2.The input energy range is from 5 to 350 keV.For this 8-channel prototype ASIC,the measured electrical characteristics are as follows:the overall gain of the readout channel is 210 V/pC,the linearity error is less than 2%,the crosstalk is less than 0.36%,The equivalent noise charge of a typical channel is 52.9 e^- at zero farad plus 8.2 e^- per picofarad,and the power consumption is less than 2.4 mW/channel.Through the measurement together with a CdZnTe detector,the energy resolution is 5.9%at the 59.5-keV line under the irradiation of the radioactive source ^(241)Am.The radiation effect experiments show that the proposed ASIC can resist the total ionization dose(TID) irradiation of higher than200 krad(Si). 展开更多
关键词 cdznte detector low-noise front-end readout ASIC X-ray radiation-hardened
原文传递
Parallel readout of two-element CdZnTe detectors with real-time digital signal processing
9
作者 施朱斌 王林军 +6 位作者 秦凯丰 闵嘉华 张继军 梁小燕 黄健 唐可 夏义本 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2010年第12期83-86,共4页
Readout electronics, especially digital electronics, for two-element CdZnTe (CZT) detectors in parallel are developed. The preliminary results show the detection efficiency of the two-element CZT detectors in parall... Readout electronics, especially digital electronics, for two-element CdZnTe (CZT) detectors in parallel are developed. The preliminary results show the detection efficiency of the two-element CZT detectors in parallel with analog electronics is as many as 1.8 and 2.1 times the single ones, and the energy resolution (FWHM) is limited by that of the single one by the means of analog electronics. However, the digital method for signal processing will be sufficiently better by contrast with an analog method especially in energy resolution. The energy resolution by the means of digital electronics can be improved by about 26.67%, compared to that only with analog electronics, while their detection efficiency is almost the same. The cause for this difference is also discussed. 展开更多
关键词 cdznte detectors detectors in parallel digital method radiation measurement
原文传递
Performance simulation and structure design of Binode CdZnTe gamma-ray detector 被引量:1
10
作者 牛莉博 李玉兰 +4 位作者 张岚 傅楗强 江灏 何彬 李元景 《Nuclear Science and Techniques》 SCIE CAS CSCD 2014年第1期53-58,共6页
A new electrode structure CdZnTe(Cadmium Zinc Telluride) detector named Binode CdZnTe has been proposed in this paper.Together with the softwares of MAXWELL,GEANT4,and ROOT,the charge collection process and its gamma ... A new electrode structure CdZnTe(Cadmium Zinc Telluride) detector named Binode CdZnTe has been proposed in this paper.Together with the softwares of MAXWELL,GEANT4,and ROOT,the charge collection process and its gamma spectrum of the detector have been simulated and the detector structure has been optimized.In order to improve its performance further,Compton scattering effect correction has been used.The simulation results demonstrate that with refined design and Compton scattering effect correction,Binode CdZnTe detectors is capable of achieving 3.92%FWHM at 122 keV,and 1.27%FWHM at 662 keV.Compared with other single-polarity(electron-only) detector configurations,Binode CdZnTe detector offers a cost effective and simple structure alternative with comparable energy resolution. 展开更多
关键词 结构设计 性能模拟 检测器 阳极 ZNTE 碲锌镉探测器 Γ射线 CD
下载PDF
电极对CdZnTe光电探测器性能的影响 被引量:1
11
作者 师好智 王林军 《上海大学学报(自然科学版)》 CAS CSCD 北大核心 2023年第4期796-802,共7页
CdZnTe材料具有较宽的禁带宽度和化学稳定性,使其成为制备紫外光电探测器的理想材料.电极与CdZnTe材料之间良好的接触特性对制备高灵敏度和高稳定性的紫外探测器具有关键作用.制备了单电极Au/CdZnTe/Au探测器和复合电极Au/GaZnO(GZO)/Cd... CdZnTe材料具有较宽的禁带宽度和化学稳定性,使其成为制备紫外光电探测器的理想材料.电极与CdZnTe材料之间良好的接触特性对制备高灵敏度和高稳定性的紫外探测器具有关键作用.制备了单电极Au/CdZnTe/Au探测器和复合电极Au/GaZnO(GZO)/CdZnTe/GZO/Au探测器,研究了不同电极对CdZnTe紫外光电探测器性能的影响. 展开更多
关键词 cdznte 电极 光电探测器 紫外线探测器 接触特性
下载PDF
Analysis of Te and TeO<sub>2</sub>on CdZnTe Nuclear Detectors Treated with Hydrogen Bromide and Ammonium-Based Solutions
12
作者 Mebougna L. Drabo Stephen U. Egarievwe +3 位作者 Ifechukwude O. Okwechime Dominique E. Jones Anwar Hossain Ralph B. James 《Journal of Materials Science and Chemical Engineering》 2017年第4期9-18,共10页
Surface defects caused during cutting and polishing in the fabrication of cadmium zinc telluride (CdZnTe) nuclear detectors limit their spectral performance. Chemical treatments are often used to remove surface damage... Surface defects caused during cutting and polishing in the fabrication of cadmium zinc telluride (CdZnTe) nuclear detectors limit their spectral performance. Chemical treatments are often used to remove surface damages and defects. In this paper, we present the analysis of Te and TeO2 species on the surfaces of CdZnTe nuclear detectors treated with hydrogen bromide and ammonium-based solutions. The CdZnTe wafers were chemo-mechanically polished in a mixture of hydrogen bromide in hydrogen peroxide and ethylene glycol, followed by a chemical passivation in a mixture of ammonium fluoride and hydrogen peroxide solution. X-ray photoelectron spectroscopy showed significant conversion of Te to TeO2, thus producing a more chemically stable surface. The resistivity of the CdZnTe samples is in the order of 1010 ohms-cm. The current for a given applied voltage increased following the passivation and decreased after a 3-hour period. Results from spectral response measurements showed that the 59.5-keV gamma-peak of Am-241 was stable under the same channel for the surface treatment processes. 展开更多
关键词 cdznte Chemical Treatment Nuclear detectors Surface PASSIVATION XPS
下载PDF
Study of Chemical Etching and Chemo-Mechanical Polishing on CdZnTe Nuclear Detectors 被引量:1
13
作者 Aaron L. Adams Stephen U. Egarievwe +4 位作者 Ezekiel O. Agbalagba Rubi Gul Anwar Hossain Utpal N. Roy Ralph B. James 《Journal of Materials Science and Chemical Engineering》 2019年第8期33-41,共9页
Cadmium zinc telluride (CdZnTe) semiconductor has applications in the detection of X-rays and gamma-rays at room temperature without having to use a cooling system. Chemical etching and chemo-mechanical polishing are ... Cadmium zinc telluride (CdZnTe) semiconductor has applications in the detection of X-rays and gamma-rays at room temperature without having to use a cooling system. Chemical etching and chemo-mechanical polishing are processes used to smoothen CdZnTe wafer during detector device fabrication. These processes reduce surface damages left after polishing the wafers. In this paper, we compare the effects of etching and chemo-mechanical polishing on CdZnTe nuclear detectors, using a solution of hydrogen bromide in hydrogen peroxide and ethylene glycol mixture. X-ray photoelectron spectroscopy (XPS) was used to monitor TeO2 on the wafer surfaces. Current-voltage and detector-response measurements were made to study the electrical properties and energy resolution. XPS results showed that the chemical etching process resulted in the formation of more TeO2 on the detector surfaces compared to chemo-mechanical polishing. The electrical resistivity of the detector is of the order of 1010 &#937;-cm. The chemo-mechanical polishing process increased the leakage current more that chemical etching. For freshly treated surfaces, the etching process is more detrimental to the energy resolution compared to chemo-mechanically polishing. 展开更多
关键词 cdznte CHEMICAL ETCHING Chemo-Mechanical POLISHING Gamma RAYS Nuclear detectors X-Ray PHOTOELECTRON Spectroscopy
下载PDF
平面型CdZnTe探测器电荷收集效率对能谱测量的影响 被引量:4
14
作者 李杨 罗文芸 +2 位作者 贾晓斌 张家磊 王林军 《上海大学学报(自然科学版)》 CAS CSCD 北大核心 2016年第2期231-237,共7页
采用蒙特卡洛程序Geant4构建平面型CdZnTe探测器,模拟^(241)Am(59.5 keV)与^(137)Cs(662 keV)两种不同能量射线从阴极面垂直入射探测器.通过在Geant4中添加Hecht方程来计算探测器不同位置处的电荷收集效率.根据模拟输出的能谱,结合能量... 采用蒙特卡洛程序Geant4构建平面型CdZnTe探测器,模拟^(241)Am(59.5 keV)与^(137)Cs(662 keV)两种不同能量射线从阴极面垂直入射探测器.通过在Geant4中添加Hecht方程来计算探测器不同位置处的电荷收集效率.根据模拟输出的能谱,结合能量沉积分布、电子-空穴对分布及其相互作用类型,在考虑电荷收集效率的情况下,研究了探测器能谱测量的变化.结果发现,在考虑电荷收集效率后,能谱向低能部分偏移,偏移程度与最大电荷收集效率紧密相关. 展开更多
关键词 GEANT4 cdznte探测器 电子 空穴对 电荷收集效率 能谱
下载PDF
基于Monte-Carlo模拟和峰形拟合的CdZnTe探测器G(E)函数简便计算方法研究 被引量:5
15
作者 黄金峰 王莹 +2 位作者 熊文俊 骆志平 陈凌 《原子能科学技术》 EI CAS CSCD 北大核心 2017年第1期165-169,共5页
提出了一种简便的CdZnTe探测器能谱-剂量转换函数(G(E)函数)的计算方法。峰形拟合函数被用于表征CdZnTe探测器对γ射线的低能拖尾,峰形拟合函数的参数通过实验测量获取,并通过拟合得到其随能量变化的关系。Monte-Carlo模拟计算得到的探... 提出了一种简便的CdZnTe探测器能谱-剂量转换函数(G(E)函数)的计算方法。峰形拟合函数被用于表征CdZnTe探测器对γ射线的低能拖尾,峰形拟合函数的参数通过实验测量获取,并通过拟合得到其随能量变化的关系。Monte-Carlo模拟计算得到的探测器理想沉积谱,经峰形拟合函数卷积得到了修正的模拟能谱,修正的模拟能谱与实际测量能谱吻合较好。基于修正的模拟能谱计算得到了CdZnTe探测器的G(E)函数。标准辐射场中的实验结果表明,用G(E)函数加权积分计算的周围剂量当量率与约定真值基本一致。 展开更多
关键词 cdznte探测器 G(E)函数 峰形拟合 MONTE-CARLO模拟
下载PDF
室温半导体CdZnTe(CdTe)探测器性能综述 被引量:27
16
作者 艾宪芸 魏义祥 《核电子学与探测技术》 CAS CSCD 北大核心 2004年第3期325-328,277,共5页
CdZnTe(CdTe)探测器是近年来迅速发展的新型半导体探测器,具有体积小、分辨率高、可在室温下工作等优点。由于探测器晶体内电荷收集不完全,导致所测的γ谱会产生低能尾巴,从而增加了谱解析的困难,需要进行新的解谱算法研究。介绍了其基... CdZnTe(CdTe)探测器是近年来迅速发展的新型半导体探测器,具有体积小、分辨率高、可在室温下工作等优点。由于探测器晶体内电荷收集不完全,导致所测的γ谱会产生低能尾巴,从而增加了谱解析的困难,需要进行新的解谱算法研究。介绍了其基本性能、电极设计、γ谱解析方法和发展趋势。 展开更多
关键词 镉锌碲探测器 碲化镉探测器 Γ谱 谱解析 半导体
下载PDF
基于CdZnTe探测器的低噪声小尺寸电荷灵敏前置放大器的设计 被引量:4
17
作者 郝魁红 王化祥 赵迎春 《核技术》 EI CAS CSCD 北大核心 2007年第5期459-462,共4页
通过分析CdZnTe半导体射线探测器的性能,并考虑到电荷灵敏放大器的噪声特性,设计了用于便携式探测器中的低噪声小尺寸电荷灵敏放大器。在常温下,3mm×7mm×3mm的CdZnTe探测器与小尺寸电荷灵敏前置放大器探测系统对于241Amd的59.... 通过分析CdZnTe半导体射线探测器的性能,并考虑到电荷灵敏放大器的噪声特性,设计了用于便携式探测器中的低噪声小尺寸电荷灵敏放大器。在常温下,3mm×7mm×3mm的CdZnTe探测器与小尺寸电荷灵敏前置放大器探测系统对于241Amd的59.5keVγ射线的能量分辨率为4.38%。 展开更多
关键词 电荷灵敏放大器 cdznte探测器 噪声 能量分辨率
下载PDF
基于CdZnTe像素阵列探测技术的伽玛源成像 被引量:8
18
作者 黎淼 肖沙里 +4 位作者 张流强 曹玉琳 陈宇晓 沈敏 王玺 《强激光与粒子束》 EI CAS CSCD 北大核心 2010年第9期2165-2170,共6页
根据高能射线针孔成像理论,采用CdZnTe像素阵列探测器建立了直接成像探测模式的伽玛源针孔探测系统。测试分析了CdZnTe像素阵列探测器的能量分辨力及峰值效率,讨论研究了针孔成像探测系统的调制传递函数和附加噪声特性,测试获得直径5mm1... 根据高能射线针孔成像理论,采用CdZnTe像素阵列探测器建立了直接成像探测模式的伽玛源针孔探测系统。测试分析了CdZnTe像素阵列探测器的能量分辨力及峰值效率,讨论研究了针孔成像探测系统的调制传递函数和附加噪声特性,测试获得直径5mm137Cs源的探测图像,采用Lucy-Richardson迭代算法得到了137Cs源的复原图像。实验结果表明:CdZnTe探测器对662keV137Cs源的能量分辨力为6.25%~7.50%,峰值效率65.0%~72.5%;成像系统探测图像存在一定扩散现象,所采用的Lucy-Richardson迭代复原算法能较好地修正图像扩散,提高探测图像中心区域细节分辨力;估算所得137Cs源尺寸误差约0.5mm,所建立的CdZnTe针孔成像探测系统能有效得到小尺寸伽玛源的辐照强度分布及尺寸信息。 展开更多
关键词 辐射成像探测 半导体探测器 cdznte 针孔成像 峰值效率
下载PDF
CdZnTe像素探测器的制备与表征 被引量:3
19
作者 王闯 查钢强 +3 位作者 齐阳 郭榕榕 王光祺 介万奇 《原子能科学技术》 EI CAS CSCD 北大核心 2015年第7期1320-1324,共5页
本文采用CdZnTe单晶制成像素探测器,并对其能谱响应特性及均匀性进行了系统表征。通过I-V和能谱响应测试,测定了晶体的电阻率和载流子迁移率与寿命的积,并用红外透过显微成像观察了晶体内Te夹杂的分布特性。采用光刻、剥离和真空蒸镀技... 本文采用CdZnTe单晶制成像素探测器,并对其能谱响应特性及均匀性进行了系统表征。通过I-V和能谱响应测试,测定了晶体的电阻率和载流子迁移率与寿命的积,并用红外透过显微成像观察了晶体内Te夹杂的分布特性。采用光刻、剥离和真空蒸镀技术,在CdZnTe晶片上制备了8×8的像素电极,用丝网印刷和贴片技术通过导电银胶实现像素电极与读出电路的准确连接,制备出CdZnTe像素探测器。对像素探测器的测试表明,-300V下单像素最大漏电流小于0.7nA,对241 Am 59.5keV的能量分辨率可达5.6%,优于平面探测器。进一步分析了晶体内Te夹杂等缺陷对探测器漏电流和能谱响应特性的影响规律,结果表明,Te夹杂的聚集会显著增加漏电流,并降低探测器的能量分辨率。 展开更多
关键词 cdznte 像素探测器 能量分辨率
下载PDF
人工神经网络解析CdZnTe探测器γ谱 被引量:4
20
作者 艾宪芸 魏义祥 肖无云 《核电子学与探测技术》 CAS CSCD 北大核心 2005年第6期626-629,共4页
半导体CdZnTe探测器具有体积小、分辨率高、可在室温下工作等优点而适用于野外便携式γ谱仪系统。由于CdZnTe晶体内电荷收集不完全导致γ谱产生低能尾巴,因而增加了常规谱解析的难度。采用了人工神经网络方法进行全γ谱法定性定量分析,... 半导体CdZnTe探测器具有体积小、分辨率高、可在室温下工作等优点而适用于野外便携式γ谱仪系统。由于CdZnTe晶体内电荷收集不完全导致γ谱产生低能尾巴,因而增加了常规谱解析的难度。采用了人工神经网络方法进行全γ谱法定性定量分析,可以充分利用γ谱所含信息,迅速准确地得出结果,避免了采用常规谱解析方法时低能尾巴对峰形拟合的影响。 展开更多
关键词 cdznte探测器 人工神经网络 Γ能谱 核素识别
下载PDF