期刊文献+
共找到109篇文章
< 1 2 6 >
每页显示 20 50 100
Bioinspired Closed-loop CPG-based Control of a Robotic Manta for Autonomous Swimming
1
作者 Yiwei Hao Yonghui Cao +5 位作者 Yingzhuo Cao Xiong Mo Qiaogao Huang Lei Gong Guang Pan Yong Cao 《Journal of Bionic Engineering》 SCIE EI CSCD 2024年第1期177-191,共15页
Fish in nature exhibit a variety of swimming modes such as forward swimming,backward swimming,turning,pitching,etc.,enabling them to swim in complex scenes such as coral reefs.It is still difficult for a robotic fish ... Fish in nature exhibit a variety of swimming modes such as forward swimming,backward swimming,turning,pitching,etc.,enabling them to swim in complex scenes such as coral reefs.It is still difficult for a robotic fish to swim autonomously in a confined area as a real fish.Here,we develop an untethered robotic manta as an experimental platform,which consists of two flexible pectoral fins and a tail fin,with three infrared sensors installed on the front,left,and right sides of the head to sense the surrounding obstacles.To generate multiple swimming modes of the robotic manta and online switching of different modes,we design a closed-loop Central Pattern Generator(CPG)controller based on distance information and use a combination of phase difference and amplitude of the CPG model to achieve stable and rapid adjustment of yaw angle.To verify the autonomous swimming ability of the robotic manta in complex scenes,we design an experimental scenario with a concave obstacle.The experimental results show that the robotic manta can achieve forward swimming,backward swimming,in situ turning within the concave obstacle,and finally exit from the area safely while relying on the perception of external obstacles,which can provide insight into the autonomous exploration of complex scenes by the biomimetic robotic fish.Finally,the swimming ability of the robotic manta is verified by field tests. 展开更多
关键词 Biomimetic robotic manta Central Pattern Generator closed-loop control Backward swimming
下载PDF
A chaotic hierarchical encryption/watermark embedding scheme for multi-medical images based on row-column confusion and closed-loop bi-directional diffusion
2
作者 张哲祎 牟俊 +1 位作者 Santo Banerjee 曹颖鸿 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第2期228-237,共10页
Security during remote transmission has been an important concern for researchers in recent years.In this paper,a hierarchical encryption multi-image encryption scheme for people with different security levels is desi... Security during remote transmission has been an important concern for researchers in recent years.In this paper,a hierarchical encryption multi-image encryption scheme for people with different security levels is designed,and a multiimage encryption(MIE)algorithm with row and column confusion and closed-loop bi-directional diffusion is adopted in the paper.While ensuring secure communication of medical image information,people with different security levels have different levels of decryption keys,and differentiated visual effects can be obtained by using the strong sensitivity of chaotic keys.The highest security level can obtain decrypted images without watermarks,and at the same time,patient information and copyright attribution can be verified by obtaining watermark images.The experimental results show that the scheme is sufficiently secure as an MIE scheme with visualized differences and the encryption and decryption efficiency is significantly improved compared to other works. 展开更多
关键词 chaotic hierarchical encryption multi-medical image encryption differentiated visual effects row-column confusion closed-loop bi-directional diffusion transform domain watermark embedding
原文传递
Evaluation of hybrid closed-loop insulin delivery system in type 1 diabetes in real-world clinical practice:One-year observational study
3
作者 Ahmed Eldib Shilton Dhaver +8 位作者 Karim Kibaa Astrid Atakov-Castillo Tareq Salah Marwa Al-Badri Abdelrahman Khater Ryan McCarragher Omnia Elenani Elena Toschi Osama Hamdy 《World Journal of Diabetes》 SCIE 2024年第3期455-462,共8页
BACKGROUND In 2016,the Food and Drug Administration approved the first hybrid closed-loop(HCL)insulin delivery system for adults with type 1 diabetes(T1D).There is limited information on the impact of using HCL system... BACKGROUND In 2016,the Food and Drug Administration approved the first hybrid closed-loop(HCL)insulin delivery system for adults with type 1 diabetes(T1D).There is limited information on the impact of using HCL systems on patient-reported outcomes(PROs)in patients with T1D in real-world clinical practice.In this independent study,we evaluated glycemic parameters and PROs over one year of continuous use of Medtronic’s 670G HCL in real-world clinical practice.AIM To assess the effects of hybrid closed loop system on glycemic control and quality of life in adults with T1D.METHODS We evaluated 71 patients with T1D(mean age:45.5±12.1 years;59%females;body weight:83.8±18.7 kg,body mass index:28.7±5.6 kg/m2,A1C:7.6%±0.8%)who were treated with HCL at Joslin Clinic from 2017 to 2019.We measured A1C and percent of glucose time-in-range(%TIR)at baseline and 12 months.We measured percent time in auto mode(%TiAM)for the last two weeks preceding the final visit and assessed PROs through several validated quality-of-life surveys related to general health and diabetes management.RESULTS At 12 mo,A1C decreased by 0.3%±0.1%(P=0.001)and%TIR increased by 8.1%±2.5%(P=0.002).The average%TiAM was only 64.3%±32.8%and was not associated with A1C,%TIR or PROs.PROs,provided at baseline and at the end of the study,showed that the physical functioning submodule of 36Item Short-Form Health Survey increased significantly by 22.9%(P<0.001).Hypoglycemia fear survey/worry scale decreased significantly by 24.9%(P<0.000);Problem Areas In Diabetes reduced significantly by-17.2%(P=0.002).The emotional burden submodules of dietary diversity score reduced significantly by-44.7%(P=0.001).Furthermore,analysis of Clarke questionnaire showed no increase in awareness of hypoglycemic episodes.WHO-5 showed no improvements in subject’s wellbeing among participants after starting the 670G HCL system.Finally,analysis of Pittsburgh Sleep Quality Index showed no difference in sleep quality,sleep latency,or duration of sleep from baseline to 12 mo.CONCLUSION The use of HCL in real-world clinical practice for one year was associated with significant improvements in A1C,%TIR,physical functioning,hypoglycemia fear,emotional distress,and emotional burden related to diabetes management.However,these changes were not associated with time in auto mode. 展开更多
关键词 Artificial pancreas Continuous blood glucose monitor Type 1 diabetes Hybrid closed-loop insulin delivery Quality of life
下载PDF
A compact and closed-loop spin-exchange relaxation-free atomic magnetometer for wearable magnetoencephalography
4
作者 郭清乾 胡涛 +10 位作者 冯晓宇 张明康 陈春巧 张欣 姚泽坤 徐佳玉 王青 付方跃 张寅 常严 杨晓冬 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第4期277-282,共6页
Atomic magnetometers operated in the spin-exchange relaxation-free(SERF)regime are the promising sensor to replace superconducting quantum interference devices(SQUIDs)in the biomagnetism field.The SERF magnetometer wi... Atomic magnetometers operated in the spin-exchange relaxation-free(SERF)regime are the promising sensor to replace superconducting quantum interference devices(SQUIDs)in the biomagnetism field.The SERF magnetometer with compact size and good performance is crucial to the new generation of wearable magnetoencephalography(MEG)system.In this paper,we developed a compact and closed-loop SERF magnetometer with the dimensions of 15.0×22.0×30.0 mm^(3)based on a single-beam configuration.The bandwidth of the magnetometer was extended to 675 Hz while the sensitivity was maintained at 22 f T/Hz^(1/2).A nearly 3-fold enhancement of the bandwidth was obtained in comparison with the open-loop control.The implementation of the closed-loop control also greatly improved the dynamic range,enabling the magnetometer to be robust against the disturbance of the ambient field.Moreover,the magnetometer was successfully applied for the detection of humanα-rhythm and auditory evoked fields(AEFs),which demonstrated the potential to be extended to multi-channel MEG measurements for future neuroscience studies. 展开更多
关键词 atomic magnetometer MINIATURIZATION closed-loop magnetoencephalography(MEG)
原文传递
Type Synthesis of Fully Decoupled Three Translational Parallel Mechanism with Closed-Loop Units and High Stifness
5
作者 Shihua Li Sen Wang +2 位作者 Haoran Li Yongjie Wang Shuang Chen 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2023年第5期231-247,共17页
In order to solve the problem of weak stifness of the existing fully decoupled parallel mechanism, a new synthesis method of fully decoupled three translational (3T) parallel mechanisms (PMs) with closed-loop units an... In order to solve the problem of weak stifness of the existing fully decoupled parallel mechanism, a new synthesis method of fully decoupled three translational (3T) parallel mechanisms (PMs) with closed-loop units and high stifness is proposed based on screw theory. Firstly, a new criterion for the full decoupled of PMs is presented that the reciprocal product of the transmission wrench screw matrix and the output twist screw matrix of PMs is a diagonal matrix, and all elements on the main diagonal are nonzero constants. The forms of the transmission wrench screws are determined by the criterion. Secondly, the forms of the actuated and unactuated screws can be obtained according to their relationships with the transmission wrench screws. The basic decoupled limbs are generated by combination of the above actuated and unactuated screws. Finally, a closed-loop units construction method is investigated to apply the decoupled mechanisms in a better way on the high stifness occasion. The closed-loop units are constructed in the basic decoupled limbs to generate a high-stifness fully decoupled 3T PM. Kinematic and stifness analyses show that the Jacobian matrix is a diagonal matrix, and the stifness is obviously higher than that of the coupling mechanisms, which verifes the correctness of the proposed synthesis method. The mechanism synthesized by this method has a good application prospect in vehicle durability test platform. 展开更多
关键词 Screw theory Three translational parallel mechanism Full decoupled closed-loop units High stifness
下载PDF
Subspace Identification for Closed-Loop Systems With Unknown Deterministic Disturbances
6
作者 Kuan Li Hao Luo +2 位作者 Yuchen Jiang Dejia Tang Hongyan Yang 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2023年第12期2248-2257,共10页
This paper presents a subspace identification method for closed-loop systems with unknown deterministic disturbances.To deal with the unknown deterministic disturbances,two strategies are implemented to construct the ... This paper presents a subspace identification method for closed-loop systems with unknown deterministic disturbances.To deal with the unknown deterministic disturbances,two strategies are implemented to construct the row space that can be used to approximately represent the unknown deterministic disturbances using the trigonometric functions or Bernstein polynomials depending on whether the disturbance frequencies are known.For closed-loop identification,CCF-N4SID is extended to the case with unknown deterministic disturbances using the oblique projection.In addition,a proper Bernstein polynomial order can be determined using the Akaike information criterion(AIC)or the Bayesian information criterion(BIC).Numerical simulation results demonstrate the effectiveness of the proposed identification method for both periodic and aperiodic deterministic disturbances. 展开更多
关键词 Bernstein polynomial closed-loop system subspace identification unknown deterministic disturbances
下载PDF
Closed-Loop System Identification Approach of the Inertial Models
7
作者 Irina Cojuhari 《Applied Mathematics》 2023年第2期107-120,共14页
The mathematical model that approximates the dynamics of the industrial process is essential for the efficient synthesis of control algorithms in industrial applications. The model of the process can be obtained accor... The mathematical model that approximates the dynamics of the industrial process is essential for the efficient synthesis of control algorithms in industrial applications. The model of the process can be obtained according to the identification procedures in the open-loop, or in the closed-loop. In the open-loop, the identification methods are well known and offer good process approximation, which is not valid for the closed-loop identification, when the system provides the feedback output and doesn’t permit it to be identified in the open-loop. This paper offers an approach for experimental identification in the closed-loop, which supposes the approximation of the process with inertial models, with or without time delay and astatism. The coefficients are calculated based on the values of the critical transfer coefficient and period of the underdamped response of the closed-loop system with P controller, when system achieves the limit of stability. Finally, the closed-loop identification was verified by the computer simulation and the obtained results demonstrated, that the identification procedure in the closed-loop offers good results in process of estimation of the model of the process. 展开更多
关键词 closed-loop Identification Mathematical Modelling Inertial Models Time Delay Astatism
下载PDF
Closed-Loop MIMO系统线性预编码技术
8
作者 卢鑫 《中国新通信》 2008年第11期67-70,共4页
本文讨论了Closed-Loop MIMO系统在有限反馈资源下如何进行反馈的方法,即两种发射端线性预编码的思路,特别是其中的反馈码本设计问题。由于需要接收端向发射端反馈信道信息,而上行反馈资源又非常有限,所以发射端线性预编码技术成为解决... 本文讨论了Closed-Loop MIMO系统在有限反馈资源下如何进行反馈的方法,即两种发射端线性预编码的思路,特别是其中的反馈码本设计问题。由于需要接收端向发射端反馈信道信息,而上行反馈资源又非常有限,所以发射端线性预编码技术成为解决把MIMO技术应用于新一代蜂窝系统或无线局域网的关键问题之一,具有无限广阔的发展前景。 展开更多
关键词 closed-loop MIMO 系统 预编码 波束赋形 信道状态信息
下载PDF
Closed-loop cobalt recycling from spent lithium-ion batteries based on a deep eutectic solvent (DES) with easy solvent recovery 被引量:3
9
作者 Taibai Li Yige Xiong +4 位作者 Xiaohui Yan Tao Hu Siqi Jing Zhongjie Wang Xiang Ge 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2022年第9期532-538,I0015,共8页
Efficient recycling technology for the rapid growth of spent lithium-ion batteries(LIBs)is essential to tackle the resources and environmental crisis.Hydrometallurgical approach has attracted extensive research due to... Efficient recycling technology for the rapid growth of spent lithium-ion batteries(LIBs)is essential to tackle the resources and environmental crisis.Hydrometallurgical approach has attracted extensive research due to its potential to reduce the consumption of energy and threat to the environment.However,the simultaneous realization of green,efficient and closed-loop recycling is still challenging.Herein,we report a closed-loop and highly efficient approach to recycle lithium cobalt oxide from spent LIBs based on a choline chloride:oxalic acid(ChCl:OA)type deep eutectic solvent(DES).An ultrafast leaching process is observed at 180°C for 10 s with no observable residues.The energy barrier during leaching is calculated to be 113.9 kJ/mol.Noteworthy,the solubility of cobalt ions can be reversibly tuned by simply adding/evaporating deionized water,thus avoiding the addition of precipitant and enabling the easy recovery of the leaching solvent for realizing a closed-loop recycling process.The simultaneous realization of high efficiency,green and closed-loop process is expected to push the DES into practical application for recycling the electrodes of LIBs. 展开更多
关键词 Lithium-ion batteries recycle Deep eutectic solvent closed-loop High efficiency Solvent recovery
下载PDF
Bioinspired Closed-loop CPG-based Control of a Robot Fish for Obstacle Avoidance and Direction Tracking 被引量:2
10
作者 Jiayong Chen Bo Yin +3 位作者 Chengcai Wang Fengran Xie Ruxu Du Yong Zhong 《Journal of Bionic Engineering》 SCIE EI CSCD 2021年第1期171-183,共13页
This paper presents a study on bioinspired closed-loop Central Pattern Generator(CPG)based control of a robot fish for obstacle avoidance and direction tracking.The biomimetic robot fish is made of a rigid head with a... This paper presents a study on bioinspired closed-loop Central Pattern Generator(CPG)based control of a robot fish for obstacle avoidance and direction tracking.The biomimetic robot fish is made of a rigid head with a pair of pectoral fins,a wire-driven active body covered with soft skin,and a compliant tail.The CPG model consists of four input parameters:the flapping amplitude,the flapping angular velocity,the flapping offset,and the time ratio between the beat phase and the restore phase in flapping.The robot fish is equipped with three infrared sensors mounted on the left,front and right of the robot fish,as well as an inertial measurement unit,from which the surrounding obstacles and moving direction can be sensed.Based on these sensor signals,the closed-loop CPG-based control can drive the robot fish to avoid obstacles and to track designated directions.Four sets of experiments are presented,including avoiding a static obstacle,avoiding a moving obstacle,tracking a designated direction and tracking a designated direction with an obstacle in the path.The experiment results indicated that the presented control strategy worked well and the robot fish can accomplish the obstacle avoidance and direction tracking effectively. 展开更多
关键词 biomimetic robot fish closed-loop control Central Pattern Generator(CPG) obstacle avoidance direction tracking Copyright c Jilin University 2021.
下载PDF
Fuel cell performance assessment for closed-loop renewable energy systems 被引量:2
11
作者 Fabio V.Matera Irene Gatto +1 位作者 Assunta Patti Enza Passalacqua 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2016年第3期531-538,共8页
Fuel cells and electrolysis are promising candidates for future energy production from renewable energy sources. Usually, polymer electrolyte fuel cell systems run on hydrogen and air, while the most of electrolysis s... Fuel cells and electrolysis are promising candidates for future energy production from renewable energy sources. Usually, polymer electrolyte fuel cell systems run on hydrogen and air, while the most of electrolysis systems vent out oxygen as unused by-product. Replacing air with pure oxygen, fuel cell electrochemical performance, durability and system efficiency can be significantly increased with a further overall system simplification and increased reliability. This work, which represents the initial step for pure H_2/O_2 polymer electrolyte fuel cell operation in closed-loop systems, focuses on performance validation of a single cell operating with pure H_2/O_2 under different relative humidity(RH) levels, reactants stoichiometry conditions and temperature. As a result of this study, the most convenient and appropriate operative conditions for a polymer electrolyte fuel cell stack integrated in a closed loop system were selected. 展开更多
关键词 Polymer electrolyte fuel cell(PEFC) H2/O2 fuel cell closed-loop fuel cell system
下载PDF
Reliability Analysis on Repairable System with Dual Input Closed-Loop Feedback Link Considering Shutdown Correlation Based on Goal Oriented Methodology 被引量:2
12
作者 伊枭剑 石坚 +3 位作者 穆慧娜 张瑶 郭少伟 梁启海 《Journal of Donghua University(English Edition)》 EI CAS 2016年第2期314-318,共5页
Goal oriented( GO) methodology is a kind of success oriented system reliability analysis method and has been used widely.The repairable system with dual input closed-loop feedback link( DICLFL) considering shutdown co... Goal oriented( GO) methodology is a kind of success oriented system reliability analysis method and has been used widely.The repairable system with dual input closed-loop feedback link( DICLFL) considering shutdown correlation didn't make reliability analysis accurately based on existing GO methodology. So, a reliability analysis method used to deal with DICLFL considering shutdown correlation is provided based on GO methodology.Firstly, a new operator, which is used to describe DICLFL considering shutdown correlation,whose number is 1,is created and named as Type 9C operator. And then,the formulas of type 9C operator are derived based on Markov process theory. Finally,the new method presented in this paper is adopted to conduct the reliability analysis of an electro-hydraulic servo speed control system. The analysis result is compared with those of Monte Carlo simulation and fault tree analysis( FTA). The comparison results show that this new reliability analysis method based on GO methodology is feasible and meaningful for reliability analysis of repairable systems with DICLFL considering shutdown correlation.Meantime,it will be useful for more other applications. 展开更多
关键词 shutdown correlation goal oriented(GO) methodology GO operator dual input closed-loop feedback link(DICLFL) reliability analysis
下载PDF
Application of Single Neuron Adaptive PID Regulators with Auto-tuning Gain in Industrial Parameter(Pressure)Closed-loop Process Control Systems 被引量:1
13
作者 Shaoyuan Sun Huade Li +1 位作者 Bin Qian Jianping Wei(Information Engineering School, University of Science and Technology Beijing, Beijing 100083, China) 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 1999年第2期152-153,共2页
1IntroductionTheworkcontroloffluidmachinessuchasfans,waterPUInpsandair-Pressersetc.frequentlyemploypressureclosed-loopprocesscontrolSystems[11.IndustrialproducingandPracticingshowthatthesystemshaveaseriousPressurefluc... 1IntroductionTheworkcontroloffluidmachinessuchasfans,waterPUInpsandair-Pressersetc.frequentlyemploypressureclosed-loopprocesscontrolSystems[11.IndustrialproducingandPracticingshowthatthesystemshaveaseriousPressurefluctUationPhenomenonduringworkingPro... 展开更多
关键词 single neuron GAIN adaptiVe PID REGULATOR PRESSURE closed-loop control
下载PDF
Interference Management for DS-CDMA Systems through Closed-Loop Power Control, Base Station Assignment, and Beamforming 被引量:1
14
作者 Mohamad Dosaranian Moghadam Hamidreza Bakhshi Gholamreza Dadashzadeh 《Wireless Sensor Network》 2010年第6期472-482,共11页
In this paper, we propose a smart step closed-loop power control (SSPC) algorithm and a base station assignment method based on minimizing the transmitter power (BSA-MTP) technique in a direct sequence-code division m... In this paper, we propose a smart step closed-loop power control (SSPC) algorithm and a base station assignment method based on minimizing the transmitter power (BSA-MTP) technique in a direct sequence-code division multiple access (DS-CDMA) receiver with frequency-selective Rayleigh fading. This receiver consists of three stages. In the first stage, with constrained least mean squared (CLMS) algorithm, the desired users’ signal in an arbitrary path is passed and the inter-path interference (IPI) is reduced in other paths in each RAKE finger. Also in this stage, the multiple access interference (MAI) from other users is reduced. Thus, the matched filter (MF) can use for more reduction of the IPI and MAI in each RAKE finger in the second stage. Also in the third stage, the output signals from the matched filters are combined according to the conventional maximal ratio combining (MRC) principle and then are fed into the decision circuit of the desired user. The simulation results indicate that the SSPC algorithm and the BSA-MTP technique can significantly reduce the network bit error rate (BER) compared to the other methods. Also, we observe that significant savings in total transmit power (TTP) are possible with our methods. 展开更多
关键词 Adaptive BEAMFORMING Antenna Array Base Station ASSIGNMENT closed-loop Power Control Constrained LMS DS-CDMA
下载PDF
Pricing and decision of carbon emission reduction for closed-loop supply chain considering carbon trading mechanism 被引量:1
15
作者 YUAN Kai-fu DONG Hui 《Ecological Economy》 2019年第1期39-44,共6页
To determine the optimal pricing and carbon emission reduction decision, a closed-loop supply chain with a manufacturer and a retailer is investigated. In this system, the manufacturer manufactures new products and re... To determine the optimal pricing and carbon emission reduction decision, a closed-loop supply chain with a manufacturer and a retailer is investigated. In this system, the manufacturer manufactures new products and remanufactures used products while the retailer is responsible for selling new products and remanufactured products. The profit functions of the manufacturer and the retailer are developed, and the corresponding solution formulae for decision variables are given by the Stackelberg game model. Finally, a numerical example is given, and the optimal wholesale price, retail price, carbon emission reduction and others are obtained. Through the sensitivity of the unit carbon allowance price, some significant managerial insights are derived. 展开更多
关键词 closed-loop supply chain CARBON ALLOWANCE CARBON emission reduction INVESTMENT
原文传递
Noise behaviors of a closed-loop micro-electromechanical system capacitive accelerometer
16
作者 马铭骏 金仲和 +1 位作者 刘义冬 马铁英 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第12期4634-4644,共11页
The noise of closed loop micro-electromechanical systems(MEMS) capacitive accelerometer is treated as one of the significant performance specifications.Traditional optimization of noise performance often focuses on de... The noise of closed loop micro-electromechanical systems(MEMS) capacitive accelerometer is treated as one of the significant performance specifications.Traditional optimization of noise performance often focuses on designing large capacitive sensitivity accelerometer and applying closed loop structure to shape total noise,but different noise sources in closed loop and their behaviors at low frequencies are seldom carefully studied,especially their behaviors with different electronic parameters.In this work,a thorough noise analysis is established focusing on the four noise sources transfer functions near 0 Hz with simplified electronic parameters in closed loop,and it is found that the total electronic noise equivalent acceleration varies differently at different frequency points,such that the noise spectrum shape at low frequencies can be altered from 1/f noise-like shape to flat spectrum shape.The bias instability changes as a consequence.With appropriate parameters settings,the 670 Hz resonant frequency accelerometer can reach resolution of 2.6 μg/(Hz)1/2 at 2 Hz and 6 μg bias instability,and 1300 Hz accelerometer can achieve 5μg/(Hz)1/2 at 2 Hz and 31 μg bias instability.Both accelerometers have flat spectrum profile from 2 Hz to 15 Hz. 展开更多
关键词 closed-loop MEMS accelerometer noise spectrum shape electronic parameters bias instability
下载PDF
Simulation of Automotive Engine Phase Signal Based on Closed-Loop Strategy
17
作者 Runlong Cui Mingfa Yao Tao Chen 《Transactions of Tianjin University》 EI CAS 2017年第4期394-400,共7页
In this paper, an automotive engine phase signal simulation algorithm is proposed based on a closed-loop feedback strategy, and its corresponding model is built. The signal incentives are carried out in the front-end,... In this paper, an automotive engine phase signal simulation algorithm is proposed based on a closed-loop feedback strategy, and its corresponding model is built. The signal incentives are carried out in the front-end, and the synchronization capture and comparison are conducted in the back-end. The phase simulation of signal output is achieved using closed-loop strategy, which can effectively eliminate the inconsistency between crankshaft and camshaft phases, and thus the accuracy and flexibility of phase signal generation are guaranteed. Experimental results show that the proposed algorithm is real time, and the deviation of simulated signals from actual phase signals is small. 展开更多
关键词 closed-loop CONTROL ENGINE electronic CONTROL unit SIGNAL SIMULATION SIGNAL CAPTURE
下载PDF
Model Reference Adaptive Control for Switched Systems with Closed-loop Reference Model Under Arbitrary Switching
18
作者 Hao Yang Jing Xie Jun Zhao 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2019年第3期35-42,共8页
This paper explores the model reference adaptive control problem for a class of switched linear systems under arbitrary switching with no need for the measurability of the system state.Based on the state of reference ... This paper explores the model reference adaptive control problem for a class of switched linear systems under arbitrary switching with no need for the measurability of the system state.Based on the state of reference model and the measurable output error, adaptive laws and controllers are designed for switched systems.Each subsystem may have its individual reference model and controller, which increases the design flexibility.The introduction of the closed-loop reference model is to get a better transient performance of the whole switched systems.A numerical example is provided to verify the effectiveness of the main results. 展开更多
关键词 SWITCHED systems MODEL REFERENCE adaptive control common LYAPUNOV function arbitrary switching the closed-loop REFERENCE MODEL
下载PDF
EFFICIENT STEADY-STATE ANALYSIS METHOD FOR CLOSED-LOOP PWM SWITCHING CONVERTERS
19
作者 尹有为 马西奎 《Journal of Pharmaceutical Analysis》 SCIE CAS 2006年第1期6-12,共7页
An analysis technique of steady state and stability for closed-loop PWM DC/DC switching converters is presented. Using this method, the closed-loop switching converter is transformed into an open-loop system. By means... An analysis technique of steady state and stability for closed-loop PWM DC/DC switching converters is presented. Using this method, the closed-loop switching converter is transformed into an open-loop system. By means of the fact that in steady state, the two boundary values are equal in one switching period. The exponential matrix is evaluated by precise time-domain-integration method, and then the related curve between feedback duty cycle and the input one is obtained. Not only can the steady-state duty cycle be found from the curve, but also the stability and stable domain of the system. Compared with other methods, it features with simplicity and less calculation, and fit for numerical simulation and analysis for closed-loop switching converters. The simulation results of examples indicate the correctness of the presented method. 展开更多
关键词 closed-loop system STEADY-STATE stability analysis switching converters
下载PDF
Successful use of closed-loop allostatic neurotechnology for post-traumatic stress symptoms in military personnel: self-reported and autonomic improvements
20
作者 Catherine L.Tegeler Lee Gerdes +4 位作者 Hossam A.Shaltout Jared F.Cook Sean L.Simpson Sung W.Lee Charles H.Tegeler 《Military Medical Research》 SCIE CAS 2018年第1期1-12,共12页
Background:Military-related post-traumatic stress(PTS)is associated with numerous symptom clusters and diminished autonomic cardiovascular regulation.Highresolution,relational,resonance-based,electroencephalic mirrori... Background:Military-related post-traumatic stress(PTS)is associated with numerous symptom clusters and diminished autonomic cardiovascular regulation.Highresolution,relational,resonance-based,electroencephalic mirroringis a noninvasive,closed-loop,allostatic,acoustic stimulation neurotechnology that produces realtime translation of dominant brain frequencies into audible tones of variable pitch and timing to support the autocalibration of neural oscillations.We report clinical,autonomic,and functional effects after the use offor symptoms of military-related PTS.Methods:Eighteen service members or recent veterans(15 active-duty,3 veterans,most from special operations,1 female),with a mean age of 40.9(SD=6.9)years and symptoms of PTS lasting from 1 to 25 years,undertook19.5(SD=1.1)sessions over 12 days.Inventories for symptoms of PTS(Posttraumatic Stress Disorder Checklist–Military version,PCL-M),insomnia(Insomnia Severity Index,ISI),depression(Center for Epidemiologic Studies Depression Scale,CES-D),and anxiety(Generalized Anxiety Disorder 7-item scale,GAD-7)were collected before(Visit1,V1),immediately after(Visit2,V2),and at 1 month(Visit3,V3),3(Visit4,V4),and 6(Visit5,V5)months after intervention completion.Other measures only taken at V1 and V2 included blood pressure and heart rate recordings to analyze heart rate variability(HRV)and baroreflex sensitivity(BRS),functional performance(reaction and grip strength)testing,blood and saliva for biomarkers of stress and inflammation,and blood for epigenetic testing.Paired t-tests,Wilcoxon signed-rank tests,and a repeated-measures ANOVA were performed.Results:Clinically relevant,significant reductions in all symptom scores were observed at V2,with durability through V5.There were significant improvements in multiple measures of HRV and BRS[Standard deviation of the normal beat to normal beat interval(SDNN),root mean square of the successive differences(rMSSD),high frequency(HF),low frequency(LF),and total power,HF alpha,sequence all,and systolic,diastolic and mean arterial pressure]as well as reaction testing.Trends were seen for improved grip strength and a reduction in C-Reactive Protein(CRP),Angiotensin II to Angiotensin 1–7 ratio and Interleukin-10,with no change in DNA n-methylation.There were no dropouts or adverse events reported. Conclusion:Service members or veterans showed reductions in symptomatology of PTS,insomnia,depressive mood,and anxiety that were durable through 6 months after the use of a closed-loop allostatic neurotechnology for the autocalibration of neural oscillations.This study is the first to report increased HRV or BRS after the use of an intervention for service members or veterans with PTS.Ongoing investigations are strongly warranted.Trial registration:NCT03230890,retrospectively registered July 25,2017. 展开更多
关键词 NEUROTECHNOLOGY ALLOSTASIS AUTONOMIC Heart rate variability Baroreflex sensitivity closed-loop Acoustic stimulation Military Post-traumatic stress disorder HIRREM
原文传递
上一页 1 2 6 下一页 到第
使用帮助 返回顶部