Surface form inspection with contact coordinate measurement:a review 被引量:4
1
作者 Yijun Shen Jieji Ren +3 位作者 Nuodi Huang Yang Zhang Xinquan Zhang Limin Zhu 《International Journal of Extreme Manufacturing》 SCIE EI CAS CSCD 2023年第2期119-147,共29页
Parts with high-quality freeform surfaces have been widely used in industries,which require strict quality control during the manufacturing process.Among all the industrial inspection methods,contact measurement with ... Parts with high-quality freeform surfaces have been widely used in industries,which require strict quality control during the manufacturing process.Among all the industrial inspection methods,contact measurement with coordinate measuring machines or computer numerical control machine tool is a fundamental technique due to its high accuracy,robustness,and universality.In this paper,the existing research in the contact measurement field is systematically reviewed.First,different configurations of the measuring machines are introduced in detail,which may have influence on the corresponding sampling and inspection path generation criteria.Then,the entire inspection pipeline is divided into two stages,namely the pre-inspection and post-inspection stages.The typical methods of each sub-stage are systematically overviewed and classified,including sampling,accessibility analysis,inspection path generation,probe tip radius compensation,surface reconstruction,and uncertainty analysis.Apart from those classical research,the applications of the emerging deep learning technique in some specific tasks of measurement are introduced.Furthermore,some potential and promising trends are provided for future investigation. 展开更多
关键词 freeform surface form inspection contact measurement coordinate measurement on-machine inspection
下载PDF
Improved contact angle measurement in multiphase lattice Boltzmann
2
作者 钟兴国 刘阳莎 +2 位作者 姚怡辰 何冰 闻炳海 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第5期537-543,共7页
Contact angle is an essential parameter to characterize substrate wettability.The measurement of contact angle in experiment and simulation is a complex and time-consuming task.In this paper,an improved method of meas... Contact angle is an essential parameter to characterize substrate wettability.The measurement of contact angle in experiment and simulation is a complex and time-consuming task.In this paper,an improved method of measuring contact angle in multiphase lattice Boltzmann simulations is proposed,which can accurately obtain the real-time contact angle at a low temperature and larger density ratio.The three-phase contact point is determined by an extrapolation,and its position is not affected by the local deformation of flow field in the three-phase contact region.A series of simulations confirms that the present method has high accuracy and gird-independence.The contact angle keeps an excellent linear relationship with the chemical potential of the surface,so that it is very convenient to specify the wettability of a surface.The real-time contact angle measurement enables us to obtain the dynamic contact angle hysteresis on chemically heterogeneous surface,while the mechanical analyses can be effectively implemented at the moving contact line. 展开更多
关键词 contact angle measurement contact angle hysteresis mechanical analysis lattice Boltzmann method
原文传递
Power equipment vibration visualization using intelligent sensing method based on event-sensing principle
3
作者 Mingzhe Zhao Xiaojun Shen +1 位作者 Lei Su Zihang Dong 《Global Energy Interconnection》 EI CSCD 2024年第2期228-240,共13页
Vibration measurements can be used to evaluate the operation status of power equipment and are widely applied in equipment quality inspection and fault identification.Event-sensing technology can sense the change in s... Vibration measurements can be used to evaluate the operation status of power equipment and are widely applied in equipment quality inspection and fault identification.Event-sensing technology can sense the change in surface light intensity caused by object vibration and provide a visual description of vibration behavior.Based on the analysis of the principle underlying the transformation of vibration behavior into event flow data by an event sensor,this paper proposes an algorithm to reconstruct event flow data into a relationship correlating vibration displacement and time to extract the amplitude-frequency characteristics of the vibration signal.A vibration measurement test platform is constructed,and feasibility and effectiveness tests are performed for the vibration motor and other power equipment.The results show that event-sensing technology can effectively perceive the surface vibration behavior of power and provide a wide dynamic range.Furthermore,the vibration measurement and visualization algorithm for power equipment constructed using this technology offers high measurement accuracy and efficiency.The results of this study provide a new noncontact and visual method for locating vibrations and performing amplitude-frequency analysis on power equipment. 展开更多
关键词 Power equipment Event sensing Non contact measurement Graphic display FEASIBILITY
下载PDF
Analysis of the Correlation between the Level of Contact Degradation and the Dynamic Resistance Curve in Circuit Breakers 被引量:3
4
作者 Ronimack Trajano de Souza Edson Guedes da Costa 《Journal of Energy and Power Engineering》 2014年第6期1104-1111,共8页
The DRM (dynamic contact resistance measurement) in high voltage circuit breakers is a manner of evaluating the internal ageing condition of the chamber. DRM is similar to static contact resistance measurement testi... The DRM (dynamic contact resistance measurement) in high voltage circuit breakers is a manner of evaluating the internal ageing condition of the chamber. DRM is similar to static contact resistance measurement testing, but instead of measuring a single value when the breaker contacts are closed (static value), the ohmic resistance is measured at various contact positions, from the beginning of the contact opening until a complete separation of the contacts. The relationship between the contact resistances of the new circuit breaker and the ageing circuit breaker in operation provides subsidy for the evaluation of both the main and arcing contact conditions. This research aims to analyze the correlation between the various levels of degradation of the contacts and the configuration of the DRM curve. This work considers curve samples from new acceleration tests. breaker chamber contacts and different levels of degradation by 展开更多
关键词 DRM (dynamic contact resistance measurement) circuit breaker dynamic resistance contact resistance resistance curve.
下载PDF
Optically Powered Temperature Measuring Instrument for Big Rotor
5
作者 ZHENG Dezhong(Yanshan University, Qinhuandao 066004, CHN) 《Semiconductor Photonics and Technology》 CAS 1997年第1期35-39,共5页
Abstract: A micro - power consumption non - contact temperature measuring instrument for big rotor is introduced. As it solves very well the signal coupling under high speed rotation and power supply problem for probe... Abstract: A micro - power consumption non - contact temperature measuring instrument for big rotor is introduced. As it solves very well the signal coupling under high speed rotation and power supply problem for probe, the instrument can realize persistent on - line temperature measurement for big rotor drived by the ordinary light transmitted by optical fiber under the room light. 展开更多
关键词 Non - contact Measurement Optical Fiber ROTOR SemiconductorThermistor
下载PDF
A Contact and Non-Contact Hybrid Profilometer with Large Range
6
作者 YUN Jianping YANG Xudong +1 位作者 XIE Tiebang CHANG Suping 《Wuhan University Journal of Natural Sciences》 CAS 2007年第6期1066-1072,共7页
A novel hybrid instrument of contact and non-contact measurement with large range is developed, and both measurement systems are based on a Linnik interference microscope and on white-light interference measuring tech... A novel hybrid instrument of contact and non-contact measurement with large range is developed, and both measurement systems are based on a Linnik interference microscope and on white-light interference measuring techniques. The ambiguity presented in conventional monochromatic interferometers is not present in the contact and non-contact measurement, and they have a virtually unlimited unambiguous range. For the contact measurement, the vertical measuring range is ±5 mm with a resolution of 1 nm and the horizontal measuring range is ±25 mm in x-range and y-range with a resolution of 1.25 μm; for the non-contact measurement, the vertical measuring range is ~5 mm with a resolution of 1 nm and the horizontal resolution better than 0.5 urn. 展开更多
关键词 surface topography contact/non-contact measurement interference microscope
下载PDF
CAD-DIRECTED INSPECTION PLANNING FOR FREEFORM SURFACE USING CONTACT PROBES
7
作者 Chen Manyi Li Bin Duan Zhengcheng 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2005年第4期579-581,共3页
A methodology for CAD-directed measurement of freeform surface using a coordinate measuring machine equipped with a touch-trigger probe is presented, mainly including adaptive sampling of measurement points and regist... A methodology for CAD-directed measurement of freeform surface using a coordinate measuring machine equipped with a touch-trigger probe is presented, mainly including adaptive sampling of measurement points and registration of freeform surface. The proposed sampling method follows four steps: Freeform surface is fitted by bi-cubic B-spline; Curvedness measure of the surface is computed; Given a number of sampling points, an iterative algorithm is constructed for selecting a set of measurement points by employing the curvedness information; The measurement points is regularized for tradeoff between maximizing the measurement accuracy and minimizing the sampling time and cost. The aforesaid algorithm is demonstrated in term of a marine propeller blade. An offset surface registration method is presented to improve alignment accuracy of freeform objects, and Monte Carlo simulation is conducted to verify the effectiveness of the method. 展开更多
关键词 Freeform surface Inspection Coordinate measurement contact probe
下载PDF
A novel method for geometric quality assurance of rock joint replicas in direct shear testing-Part 2:Validation and mechanical replicability
8
作者 J.Larsson F.Johansson +3 位作者 D.Mas Ivars E.Johnson M.Flansbjer N.W.Portal 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2023年第9期2209-2223,共15页
Each rock joint is unique by nature which means that utilization of replicas in direct shear tests is required in experimental parameter studies.However,a method to acquire knowledge about the ability of the replicas ... Each rock joint is unique by nature which means that utilization of replicas in direct shear tests is required in experimental parameter studies.However,a method to acquire knowledge about the ability of the replicas to imitate the shear mechanical behavior of the rock joint and their dispersion in direct shear testing is lacking.In this study,a novel method is presented for geometric quality assurance of replicas.The aim is to facilitate generation of high-quality direct shear testing data as a prerequisite for reliable subsequent analyses of the results.In Part 1 of this study,two quality assurance parameters,smf and V_(Hp100),are derived and their usefulness for evaluation of geometric deviations,i.e.geometric reproducibility,is shown.In Part 2,the parameters are validated by showing a correlation between the parameters and the shear mechanical behavior,which qualifies the parameters for usage in the quality assurance method.Unique results from direct shear tests presenting comparisons between replicas and the rock joint show that replicas fulfilling proposed threshold values of σ_(mf)<0.06 mm and|V_(Hp100)|<0.2 mm have a narrow dispersion and imitate the shear mechanical behavior of the rock joint in all aspects apart from having a slightly lower peak shear strength.The wear in these replicas,which have similar morphology as the rock joint,is in the same areas as in the rock joint.The wear is slightly larger in the rock joint and therefore the discrepancy in peak shear strength derives from differences in material properties,possibly from differences in toughness.It is shown by application of the suggested method that the quality assured replicas manufactured following the process employed in this study phenomenologically capture the shear strength characteristics,which makes them useful in parameter studies. 展开更多
关键词 Three-dimensional(3D)scanning contact area measurements Direct shear testing Geometric quality assurance Mechanical replicability Replicas Rock joint
下载PDF
Biosorption of Cu^(2+) and Zn^(2+) by raw and autoclaved Rocella phycopsis 被引量:7
9
作者 Emine Yalcln Kltigin avusoglu Kadir Klnalloglu 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2010年第3期367-373,共7页
The behavior of Cu2+ and Zn2+ biosorption onto raw and modified Roccella phycopsis from aqueous solutions was studied. Modification process was applied by autoclavation at 121°C for 30 min. The effcts of pH, in... The behavior of Cu2+ and Zn2+ biosorption onto raw and modified Roccella phycopsis from aqueous solutions was studied. Modification process was applied by autoclavation at 121°C for 30 min. The effcts of pH, initial metal concentration and biosorbent dosage were investigated. The maximum Cu2+ biosorption was achieved at pH 5.0 and the maximum biosorption capacities of 31.5 and 37.8 mg/g were recorded for raw and modified biosorbent, respectively. In the case of Zn2+ biosorption, maximum biosorption capacities were obtained at pH 4.0 as 29.1 and 35.3 mg/g for raw and modified biosorbent, respectively. Biosorption of Zn2+ and Cu2+ on all form of R. phycopsis increased much quickly with increasing initial metal concentrations from 10 to 100 mg/L. After modification process, probable changes in the surface polarity of raw and modified R. phycopsis were investigated by contact angle measurements. As expected, R. phycopsis has a polar surface and shows a highest contact angle with water, while after autoclavation water contact angle of R. phycopsis was significantly decreased from 47.5° to 34.4°. 展开更多
关键词 BIOSORPTION Roccella phycopsis polarity contact angle measurement
下载PDF
In-vitro biomineralization and biocompatibility of friction stir additively manufactured AZ31B magnesium alloy-hydroxyapatite composites 被引量:5
10
作者 Yee-Hsien Ho Kun Man +4 位作者 Sameehan S.Joshi Mangesh V.Pantawane Tso-Chang Wu Yong Yang Narendra B.Dahotre 《Bioactive Materials》 SCIE 2020年第4期891-901,共11页
The present study aims to evaluate effect of hydroxyapatite(HA,Ca10(PO4)6OH2),a ceramic similar to natural bone,into AZ31B Mg alloy matrix on biomineralization and biocompatibility.The novel friction stir processing a... The present study aims to evaluate effect of hydroxyapatite(HA,Ca10(PO4)6OH2),a ceramic similar to natural bone,into AZ31B Mg alloy matrix on biomineralization and biocompatibility.The novel friction stir processing additive manufacturing route was employed to fabricate Mg-HA composites.Various HA contents(5,10,20 wt%)were incorporated into Mg matrix.Microstructural observation and chemical composition analysis revealed that refined Mg grains and dispersion of HA particles at micro/nanoscales were achieved in Mg-HA composites after the friction stir processing.The biomineralization evaluation were carried out using immersion experiments in simulated body fluid followed by mineral morphology observation and chemical composition analysis.The wettability measurements were conducted to correlate the biomineralization behavior.The results showed improvement in wettability and bone-like Ca/P ratio in apatite deposit on the composites compared to as-received Mg.In addition,the increase of blood compatibility,cell viability and spreading were found in the higher HA content composites,indicating the improved biocompatibility.Therefore,friction stir processed Mg-20 wt%HA composite exhibited the highest wettability and better cell adhesion among other composites due to the effect of increased HA content within Mg matrix. 展开更多
关键词 Friction stir processing Magnesium alloy HYDROXYAPATITE Additive manufacturing BIOMINERALIZATION contact angle measurement Blood compatibility Cell culture