Computed tomography pulmonary angiography using a 20% reduction in contrast medium dose delivered in a multiphasic injection 被引量:3
1
作者 Mitchell Chen Gaith Mattar Jamal A Abdulkarim 《World Journal of Radiology》 CAS 2017年第3期143-147,共5页
AIM To evaluate the feasibility of reducing the dose of iodinated contrast agent in computed tomography pulmonary angiography(CTPA). METHODS One hundred and twenty-seven patients clinically suspected of having pulmona... AIM To evaluate the feasibility of reducing the dose of iodinated contrast agent in computed tomography pulmonary angiography(CTPA). METHODS One hundred and twenty-seven patients clinically suspected of having pulmonary embolism underwent spiral CTPA, out of whom fifty-seven received 75 mL and the remaining seventy a lower dose of 60 mL of contrast agent. Both doses were administered in a multiphasic injection. A minimum opacification threshold of 250 Hounsfield units(HU) in the main pulmonary artery is used for assessing the technical adequacy of the scans. RESULTS Mean opacification was found to be positively correlated to patient age(Pearson's correlation 0.4255, P < 0.0001) and independent of gender(male:female, 425.6 vs 450.4,P = 0.34). When age is accounted for, the study and control groups did not differ significantly in their mean opacification in the main(436.8 vs 437.9, P = 0.48),left(416.6 vs 419.8, P = 0.45) or the right pulmonary arteries(417.3 vs 423.5, P = 0.40). The number of sub-optimally opacified scans(the mean opacification in the main pulmonary artery < 250 HU) did not differ significantly between the study and control groups(7 vs 10).CONCLUSION A lower dose of iodine contrast at 60 mL can be feasibly used in CTPA without resulting in a higher number of sub-optimally opacified scans. 展开更多
关键词 Computed tomography pulmonary angiography contrast dose contrast induced nephropathy Acute kidney disease contrast safety contrast dose reduction Multiphasic injection
下载PDF
迭代模型重建与iDose4混合迭代重建在头颈部低剂量CT血管成像中的应用比较
2
作者 朱维聪 曾慧芸 +2 位作者 杜晨 吴雅婷 王彬 《影像诊断与介入放射学》 2024年第3期193-199,共7页
目的探讨迭代模型重建(IMR)对比iDose4混合迭代重建技术在低辐射剂量和低碘摄入量头颈部CT血管成像(CTA)中的应用比较。方法收集本院2024年1月—5月因需行头颈部联合动脉CTA检查,且身体质量指数不超过30 kg/m2的患者60例,分为对照组和... 目的探讨迭代模型重建(IMR)对比iDose4混合迭代重建技术在低辐射剂量和低碘摄入量头颈部CT血管成像(CTA)中的应用比较。方法收集本院2024年1月—5月因需行头颈部联合动脉CTA检查,且身体质量指数不超过30 kg/m2的患者60例,分为对照组和实验组,每组各30例。对照组采用120 kV、150 mAs、对比剂用量50 mL、注射流率5 mL/s和iDose4重建;实验组采用100 kV、100 mAs、对比剂用量30 mL、注射流率3 mL/s,分别使用iDose4和IMR进行图像重建,得到iDsoe4组和IMR组两组重建图像。测量并计算三组图像左侧颈总动脉起始部、左侧颈内动脉起始部和大脑中动脉M1段血管CT值、标准差(SD)、信噪比(SNR)和对比噪声比(CNR);记录并比较对照组和实验组病例容积CT剂量指数、剂量长度乘积,并计算有效剂量。2名诊断医师对图像质量进行主观评分。辐射剂量的比较采用独立样本t检验;CT值、SD、SNR、CNR、主观质量评分的比较采用方差分析或韦尔奇检验,两两比较采用LSD-t检验或Tamhane’s T2检验。结果对照组与IMR组各血管主观质量评分、SD、SNR、CNR的比较差异均无显著性(P>0.05);iDose4组各血管主观质量评分、SNR、CNR均明显低于对照组和IMR组,差异具有显著性(P<0.05);对照组各对应血管的CT值均明显高于iDose4组和IMR组,差异具有显著性(P<0.05);实验组有效剂量(1.62±0.08)较对照组(0.69±0.33)下降了约57.41%,对比剂碘摄入量减少了40%。结论在头颈部CTA检查中,采用低管电压、低管电流、低注射剂量及低注射流率联合IMR技术,可在保证图像质量的同时显著地降低患者辐射剂量和碘摄入量,IMR技术在降低图像噪声、提高图像SNR和CNR方面优于iDose4重建。 展开更多
关键词 迭代模型重建 辐射剂量 对比剂 CT血管成像
下载PDF
Contrast Dose and Radiation Dose Reduction in Abdominal Enhanced Computerized Tomography Scans with Single-phase Dual-energy Spectral Computerized Tomography Mode for Children with Solid Tumors 被引量:1
3
作者 Tong Yu Jun Gao +4 位作者 Zhi-Min Liu Qi-Feng Zhang Yong Liu Ling Jiang Yon Peng 《Chinese Medical Journal》 SCIE CAS CSCD 2017年第7期823-831,共9页
Background:Contrast dose and radiation dose reduction in computerized tomography (CT) scan for adult has been explored successfully,but there have been few studies on the application of low-concentration contrast i... Background:Contrast dose and radiation dose reduction in computerized tomography (CT) scan for adult has been explored successfully,but there have been few studies on the application of low-concentration contrast in pediatric abdominal CT examinations.This was a feasibility study on the use of dual-energy spectral imaging and adaptive statistical iterative reconstruction (ASiR) for the reduction of radiation dose and iodine contrast dose in pediatric abdominal CT patients with solid tumors.Methods:Forty-five patients with solid tumors who had initial CT (Group B) and follow-up CT (Group A) after chemotherapy were enrolled.The initial diagnostic CT scan (Group B) was performed using the standard two-phase enhanced CT with 320 mgI/ml concentration contrast,and the follow-up scan (Group A) was performed using a single-phase enhanced CT at 45 s after the beginning of the 270 mgI/ml contrast injection using spectral mode.Forty percent ASiR was used for the images in Group B and monochromatic images with energy levels ≥60 keV in Group A.In addition,filtered back-projection (FBP) reconstruction was used for monochromatic images 〈60 keV in Group A.The total radiation dose,total iodine load,contrast injection speed,and maximum injection pressure were compared between the two groups.The 40 keV and 60 keV spectral CT images of Group A were compared with the images of Group B to evaluate overall image quality.Results:The total radiation dose,total iodine load,injection speed,and maximum injection pressure for Group A were decreased by 19%,15%,34.4%,and 18.3%,respectively.The optimal energy level in spectral CT for displaying the abdominal vessels was 40 keV.At this level,the CT values in the abdominal aorta and its three branches,the portal vein and its two branches,and the inferior vena cava were all greater than 340 hounsfield unit (HU).The abdominal organs of Groups A and B had similar degrees of absolute and relative enhancement (t =0.36 and-1.716 for liver,0.153 and-1.546 for pancreas,and 2.427 and 0.866 for renal cortex,all P 〉 0.05).Signal-to-noise ratio of the abdominal organs was significantly lower in Group A than in Group B (t =-8.11 for liver,-7.83 for pancreas,and-5.38 for renal cortex,all P 〈 0.05).However,the subjective scores for the 40 keV (FBP) and 60 keV (40% ASiR) spectral CT images determined by two radiologists were all 〉3,indicating clinically acceptable image quality.Conclusions:Single-phase,dual-energy spectral CT used for children with solid abdominal tumors can reduce contrast dose and radiation dose and can also maintain clinically acceptable image quality. 展开更多
关键词 contrast dose Reduction PEDIATRIC Radiation dose Reduction Solid Tunlors
原文传递
Low contrast medium and radiation dose for hepatic computed tomography perfusion of rabbit VX2 tumor 被引量:2
4
作者 Cai-Yuan Zhang Yan-Fen Cui +4 位作者 Chen Guo Jing Cai Ya-Fang Weng Li-Jun Wang Deng-Bin Wang 《World Journal of Gastroenterology》 SCIE CAS 2015年第17期5259-5270,共12页
AIM:To evaluate the feasibility of low contrast medium and radiation dose for hepatic computed tomography(CT) perfusion of rabbit VX2 tumor.METHODS:Eleven rabbits with hepatic VX2 tumor underwent perfusion CT scanning... AIM:To evaluate the feasibility of low contrast medium and radiation dose for hepatic computed tomography(CT) perfusion of rabbit VX2 tumor.METHODS:Eleven rabbits with hepatic VX2 tumor underwent perfusion CT scanning with a 24-h interval between a conventional tube potential(120 k Vp) protocol with 350 mg I/m L contrast medium and filtered back projection,and a low tube potential(80 k Vp) protocol with 270 mg I/m L contrast medium with iterative reconstruction.Correlation and agreement among perfusion parameters acquired by the conventional and low dose protocols were assessed for the viable tumor component as well as whole tumor.Image noise and tumor-to-liver contrast to noise ratio during arterial and portal venous phases were evaluated.RESULTS:A 38% reduction in contrast medium dose(360.1 ± 13.3 mg I/kg vs 583.5 ± 21.5 mg I/kg,P < 0.001) and a 73% decrease in radiation dose(1898.5 m Gy·cm vs 6951.8 m Gy·cm) were observed.Interestingly,there was a strong positive correlation in hepatic arterial perfusion(r = 0.907,P < 0.001;r = 0.879,P < 0.001),hepatic portal perfusion(r = 0.819,P = 0.002;r = 0.831,P = 0.002),and hepatic blood flow(r = 0.945,P < 0.001;r = 0.930,P < 0.001) as well as a moderate correlation in hepatic perfusion index(r = 0.736,P = 0.01;r = 0.636,P = 0.035) between the low dose protocol with iterative reconstruction and the conventional protocol for the viable tumor component and the whole tumor.These two imaging protocols provided a moderate but acceptable agreement for perfusion parameters and similar tumorto-liver CNR during arterial and portal venous phases(5.63 ± 2.38 vs 6.16 ± 2.60,P = 0.814;4.60 ± 1.27 vs 5.11 ± 1.74,P = 0.587).CONCLUSION:Compared with the conventional protocol,low contrast medium and radiation dose with iterative reconstruction has no significant influence on hepatic perfusion parameters for rabbits VX2 tumor. 展开更多
关键词 LOW radiation dose LOW concentrationcontrast MEDIUM PERFUSION COMPUTED tomography Liver VX2 tumor
下载PDF
Clinical Outcome of Low Dose Contrast during Percutaneous Coronary Intervention in Patients with Moderate to Severe Kidney Impairment
5
作者 Wassam Eldin Elshafey Walaa Farid Abdel Aziz +1 位作者 Ahmed Magdy Kamal Eldin Mohamed Mahmoud Khattab 《World Journal of Cardiovascular Diseases》 2019年第11期781-795,共15页
Background: Chronic kidney disease patients are at a greater risk for nephropathy requiring dialysis after percutaneous coronary intervention. Such patients are usually deferred due to fear of “Renalism”.?Objectives... Background: Chronic kidney disease patients are at a greater risk for nephropathy requiring dialysis after percutaneous coronary intervention. Such patients are usually deferred due to fear of “Renalism”.?Objectives This study assesses the outcome of Low dose contrast protocol during PCI in CKD patients whose e-GFR 60 ml/min/1.72 m and investigates a safety margin for contrast use in these high-risk categories.?Methods: Patients were into three groups according to CV/e-GFR ratio: Group (A) low-dose: CV/e-GFR ratio 2.0 Group (B) medium-dose: CV/e-GFR ratio > 2.0 and × bodyweight\s.creatinine). Group (C) high-dose: CV/e-GFR ratio > MACD. Results: A total of 73 patients were enrolled. Average age was 54 ± 8 years,81.4% were male and 18.6% were females and 52% were diabetic. Mean baseline e-GFR was 40 ± 8.0 ml/min/1.73m2. Contrast Volume used in group A was (58.26 ± 15.05) (n = 24), in group B (109.42 ± 17.11) (n = 26) and in group C (304.5 ± 60.30) (n = 23), respectively. The incidences of CI-AKI in the 3 groups were 0%, 11.5% and 35%, respectively (p = 0.02). All-cause death 0%, 17% and introduction of maintenance hemo dialysis was 0%, 11.5% and 26%, respectively (p Conclusion: Low dose contrast protocol is safe, effective and easily applicable technique without CI-AKI or death. 展开更多
关键词 Chronic KIDNEY Disease (CKD) Maximum Allowed contrast dose (MACD) contrast Induced Acute KIDNEY Injury (CI-AKI) Low dose Protocol contrast Volume to e-GFR Ratio
下载PDF
Optimization of Contrast Material Dose for Abdominal Multi-Detector Row CT: Predicting Patient Lean Body Weight by Using Preliminary Transverse CT Images
6
作者 Antonino Guerrisi Daniele Marin +4 位作者 Huiman Barnhart Lisa Ho Thomas L. Toth Carlo Catalano Rendon C. Nelson 《Advances in Computed Tomography》 2014年第1期1-10,共10页
Estimated LBW could be used to determine the contrast material dose and rate during MDCT. The aim of this study is to test the accuracy of a technique for estimation of lean body weight (LBW) from a single multi-detec... Estimated LBW could be used to determine the contrast material dose and rate during MDCT. The aim of this study is to test the accuracy of a technique for estimation of lean body weight (LBW) from a single multi-detector row computed tomographic (MDCT) abdominal image, using a bioelectrical body composition analyzer scale as the reference standard. CT images of 21 patients with previously measured LBW (mLBW) were processed using computer-assisted, vendor-specific software (Advantage Windows 4.2;GE Healthcare, Inc). For each transverse image, a fat-fraction was automatically measured as the number of fat pixels (-200 to -50 HU) divided by the total number of pixels having an attenuation value ≥-200 HU. Estimated LBW (eLBW) of five single contiguous sections was calculated in each of three abdominal regions (upper abdomen, mid abdomen and pelvis) by multiplying TBW by (1 – fat-fraction). Bland-Altman plot with limits of agreement was used to assess agreement between mLBW and eLBW. The mean mLBW for all patients was 56 kg (range, 39 - 75 kg). Mean differences and limits of agreement between mLBW and eLBW measurements for the upper abdomen, mid abdomen and pelvis reported were -8.9 kg (-25.6 kg, +7.5 kg), -10.6 kg (-27.7 kg, +6.4 kg), and +0.5 kg (-12.8 kg, +13.8 kg) respectively. eLBW deriving directly from a transverse CT image of the pelvis can accurately predict mLBW. 展开更多
关键词 LEAN Body WEIGHT Multi-Detector CT contrast dose
下载PDF
Effects of oral contrast on dose in abdominopelvic computed tomography with pure iterative reconstruction
7
作者 Kevin P Murphy Liam J Healy +5 位作者 Lee Crush Maria Twomey Fiachra Moloney Sylvia Sexton Owen J O'Connor Michael M Maher 《World Journal of Radiology》 CAS 2016年第9期809-815,共7页
AIM To assess the effect of neutral(NC) and positive(PC) oral contrast use on patient dose in low-dose abdominal computed tomography(CT).METHODS Low-dose clinically indicated CTs were performed on 79 Crohn's patie... AIM To assess the effect of neutral(NC) and positive(PC) oral contrast use on patient dose in low-dose abdominal computed tomography(CT).METHODS Low-dose clinically indicated CTs were performed on 79 Crohn's patients(35 = PC, 1 L 2% gastrografin; 44 = NC, 1.5 L polyethylene glycol). Scanner settings for both acquisitions were identical apart from 25 s difference in intravenous contrast timing. Body mass index(BMI), scan-ranges, dose-length product and size-specific dose estimated were recorded. Data was reconstructed with pure model-based iterative reconstruction. Image quality was objectively and subjectively analysed. Data analysis was performed with Statistical Package for Social Scientists.RESULTS Higher doses were seen in neutral contrast CTs(107.60 ± 78.7 m Gy.cm, 2.47 ± 1.21 m Gy vs 85.65 ± 58.2 m Gy.cm, 2.18 ± 0.96 m Gy). The differencehad both NC and PC investigations. Image-quality assessment yielded 6952 datapoints. NC image quality was significantly superior(P < 0.001)(objective noise, objective signal to noise ratio, subjective spatial resolution, subjective contrast resolution, diagnostic acceptability) at all levels. NC bowel distension was significantly(P < 0.001) superior.CONCLUSION The use of polyethylene glycol as a neutral OC agent leads to higher radiation doses than standard positive contrast studies, in low dose abdominal CT imaging. This is possibly related to the osmotic effect of the agent resulting in larger intraluminal fluid volumes and resultant increased overall beam attenuation. 展开更多
关键词 Radiation dose Low dose COMPUTED TOMOGRAPHY ABDOMINAL imaging ORAL contrast COMPUTED TOMOGRAPHY
下载PDF
钆对比剂剂量对增强T2 FLAIR序列与增强T1WI序列脑转移瘤强化效果的影响及对比研究 被引量:1
8
作者 曹明慧 苏赟 +3 位作者 苏卫锋 毛家骥 李韵华 沈君 《磁共振成像》 CAS CSCD 北大核心 2024年第1期152-157,共6页
目的 对比不同剂量钆对比剂注射后增强液体衰减反转恢复(contrast enhanced T2 fluid attenuated inversion recovery,CE-T2 FLAIR)序列与对比增强T1WI(contrast enhanced T1WI, CE-T1WI)上脑转移瘤的强化效果,探讨半剂量对比剂条件下CE... 目的 对比不同剂量钆对比剂注射后增强液体衰减反转恢复(contrast enhanced T2 fluid attenuated inversion recovery,CE-T2 FLAIR)序列与对比增强T1WI(contrast enhanced T1WI, CE-T1WI)上脑转移瘤的强化效果,探讨半剂量对比剂条件下CE-T2 FLAIR序列在脑转移瘤MRI检查的诊断价值。材料与方法 前瞻性纳入颅外原发恶性肿瘤经病理学明确诊断、脑转移瘤经病理或临床随访证实的患者30例,于3.0 T MRI设备行头颅MRI增强扫描,在常规平扫序列的基础上,行半剂量(0.05 mmol/kg)CE-T2 FLAIR和CE-T1WI扫描,随后分次补充钆对比剂达常规剂量(0.1 mmol/kg)后至双倍剂量(0.2 mmol/kg),在注射对比剂后均进行CE-T2 FLAIR和CE-T1WI扫描。由两位观察者对三次扫描的CE-T2 FLAIR和CE-T1WI图像进行客观测量。计算不同剂量条件下CE-T2 FLAIR和CE-T1WI图像的对比信噪比(contrast to noise ratio, CNR)、相对对比度(relative contrast, RC)及百分比增加(percentage increase, PI)。采用方差分析对客观测量结果进行组间比较,差异有统计学意义(P<0.05)时进行后续多重比较;采用t检验比较两组之间的差异。结果 两位观察者客观评分一致性良好。三组对比剂剂量下CE-T2 FLAIR图像间CNR值与RC值差异无统计学意义(P>0.05);与平扫T2 FLAIR相比,病灶PI增高,增强效果良好。三组对比剂剂量下CE-T1WI图像间CNR值与RC值差异有统计学意义(P<0.05),两两比较结果表明双倍剂量CE-T1WI图像上CNR值及RC值均明显大于半剂量组(P<0.05)。半剂量及常规剂量CE-T2 FLAIR图像CNR值及RC值上均较该组CE-T1WI明显增大,差异有统计学意义(P<0.05)。半剂量CE-T2 FLAIR图像CNR值及RC值均明显大于常规剂量CE-T1WI(P<0.05)。与双倍剂量CE-T1WI相比,半剂量CE-T2 FLAIR图像CNR值增大(P<0.05),RC值差异无统计学意义(P>0.05)。结论 半剂量对比剂下CE-T2FLAIR图像上脑转移瘤的强化效果与常规CE-T1WI相仿,病灶显示良好,为半剂量对比剂的CE-T2 FLAIR序列应用于脑转移瘤MRI检查提供依据。 展开更多
关键词 脑转移瘤 磁共振成像 液体衰减反转恢复序列 半剂量钆对比剂 对比增强
下载PDF
结合监测点优化的能谱扫描在双低剂量下肢动脉血管CT成像中的应用价值
9
作者 梅莞翠 李铖铖 +5 位作者 汤倩 陈文 王赛 陈素萍 杨波 刘超 《放射学实践》 CSCD 北大核心 2024年第9期1221-1227,共7页
目的:探讨能谱扫描结合腘动脉水平监测在双低剂量(低辐射剂量和低对比剂剂量)下肢动脉血管CT成像(CTA)中的应用价值。方法:前瞻性纳入需行下肢CTA检查的111例患者,分为A、B、C三组。A组(35例)采用常规扫描模式,对比剂105 mL,监测腹主动... 目的:探讨能谱扫描结合腘动脉水平监测在双低剂量(低辐射剂量和低对比剂剂量)下肢动脉血管CT成像(CTA)中的应用价值。方法:前瞻性纳入需行下肢CTA检查的111例患者,分为A、B、C三组。A组(35例)采用常规扫描模式,对比剂105 mL,监测腹主动脉;B组(38例)采用能谱扫描模式,对比剂95 mL,监测腹主动脉;C组(38例)采用能谱扫描模式,对比剂85 mL,监测腘动脉。记录3组的辐射剂量与对比剂剂量。对于B、C两组,生成50 keV单能图像进行分析。由2位医师采用5分法对3组图像腹髂段(AIS)、股腘段(FPS)和膝下段(LKS)进行图像质量评分。测量CT值及噪声值,计算信噪比(SNR)及对比噪声比(CNR)。比较3组图像间的客观参数、主观评分、辐射剂量和对比剂剂量。结果:C组对比剂剂量较A组降低了19.04%,ED降低了14%,差异均有统计学意义(P均<0.05)。B、C两组在各血管处CT值均高于A组(P<0.05)。从腹主动脉到踝动脉,C组的客观图像质量优势逐渐显现,在踝动脉处的SNR和CNR最高,其次为B组,A组最低,差异均有统计学意义(P均<0.05)。图像质量主观评分方面,AIS段3组图像质量评分差异无统计学意义;FPS段B、C组评分高于A组;LKS段C组评分最高,B组次之,A组最低,差异有统计学意义(P<0.05)。结论:与传统下肢CTA、腹主动脉点监测扫描方案相比,能谱结合腘动脉水平监测点扫描方案在双低剂量下可提高下肢动脉的图像质量,尤其提高了对膝下血管的显示能力,具有较高的临床应用价值。 展开更多
关键词 能谱CT 体层摄影术 X线计算机 下肢动脉 辐射剂量 对比剂剂量 阈值监测
下载PDF
低剂量对比剂肺动脉CTA检查在急性肺动脉栓塞诊断中的应用价值分析 被引量:1
10
作者 宋福遥 刘巧林 《影像技术》 CAS 2024年第1期24-28,共5页
目的:探究低剂量对比剂肺动脉CTA检查在急性肺动脉栓塞诊断中的应用价值。方法:选取59例急性肺动脉栓塞患者作为研究对象,将患者分成两组(其中使用常规剂量对比剂患者29例,低剂量对比剂患者30例),所有数据均在后处理工作站行多平面重组... 目的:探究低剂量对比剂肺动脉CTA检查在急性肺动脉栓塞诊断中的应用价值。方法:选取59例急性肺动脉栓塞患者作为研究对象,将患者分成两组(其中使用常规剂量对比剂患者29例,低剂量对比剂患者30例),所有数据均在后处理工作站行多平面重组技术(multi planar reformatting,MRP)、最大密度投影(maximum intensity projection,MIP)和容积重现(volume rendering,VR)后处理,由两名高年资(副主任职称以上)医生采用双盲法行图像质量主观评价,并在工作站分析患者肺动脉CTA图像中肺动脉干及两下肺动脉CT值用统计学方法比较、肺动脉栓子检出情况对比进行客观评价。结果:常规剂量对比剂肺动脉CTA与低剂量对比剂肺动脉CTA图像质量在主观评估方面无明显差异,两组肺动脉干、两下肺动脉CT值差异无统计学意义(P>0.05)及肺静脉CT值差异有统计学意义(P<0.05),肺动脉栓子检出情况对比无差别。结论:低剂量对比剂肺动脉CTA图像质量主观评价无明显差异,客观评估无统计学意义,并且肺动脉栓子检出情况对比无明显差异,对肺动脉栓塞的诊断无影响,且所用造影剂剂量较少,故低剂量对比剂肺动脉CTA在肺栓塞诊断中的临床应用价值显著,有效降低了对比剂的使用量,为临床医师及时采取有效治疗方案提供有力的依据,值得广泛地推广应用。 展开更多
关键词 肺动脉栓塞 肺动脉CTA 诊断 低剂量对比剂 CT
下载PDF
人工智能迭代重建算法在腹部低剂量增强CT中的临床应用价值
11
作者 张宝平 李傲 +5 位作者 李宇航 朱书萌 田倩 赵文哲 杨健 金超 《遵义医科大学学报》 2024年第5期487-494,501,共9页
目的探究人工智能迭代重建(AIIR)算法在腹部低剂量增强CT中的临床应用价值。方法前瞻性纳入2023年1-8月于我院行腹部增强CT检查的患者31例,男/女(24/7);平均年龄(60.5±10.8)岁。同时采集常规剂量(100 KVp,采用管电流调制技术,剂量... 目的探究人工智能迭代重建(AIIR)算法在腹部低剂量增强CT中的临床应用价值。方法前瞻性纳入2023年1-8月于我院行腹部增强CT检查的患者31例,男/女(24/7);平均年龄(60.5±10.8)岁。同时采集常规剂量(100 KVp,采用管电流调制技术,剂量等级3级,参考管电流213 mAs)和低剂量(80 KVp,采用管电流调制技术,剂量等级1级,参考管电流47 mAs)门静脉期腹部增强CT图像并记录辐射剂量参数。常规剂量(SD)CT采用迭代(Karl)重建,低剂量(RD)CT采用Karl和AIIR算法1、3、5级强度重建。测量5组图像门静脉、肝实质、肌肉、脂肪的CT值、噪声指数、信噪比(SNR)和对比度噪声比(CNR),主观评价5组图像的整体图像质量和“蜡质感”。选择长径大于5 mm的肝脏病变共61个,测量病变的SNR及CNR并进行病变显著性主观评价。结果SD腹部增强CT的有效剂量(ED)为(7.06±2.50)mSv,RD腹部增强CT的ED为(1.18±0.54)mSv,RD组辐射剂量较SD组降低约83.3%。5组图像中肝实质、肌肉、脂肪的CT值无差异(P>0.05),门静脉CT值在SD Karl组与RDKarl组之间、RDKarl组与RDAIIR各组之间存在差异(P<0.005)。RDAIIR重建图像的噪声指数、SNR和CNR值均显著优于RD和SD Karl重建图像(P<0.005),RD AIIR 5级重建在整体图像质量和“蜡质感”方面与SD Karl重建相当,符合临床诊断要求。RDAIIR各组病变的SNR和CNR值均显著高于RDKarl组(P<0.005),RD AIIR 5组病变显著性主观评分与SD Karl组相当,高于RDKarl、RD AIIR 1、RD AIIR 3组(P<0.005)。结论AIIR算法可有效降低腹部低剂量增强CT的图像噪声,改善图像质量,提高病变显著性。 展开更多
关键词 腹部增强CT 低剂量CT 人工智能迭代重建 肝脏
下载PDF
对比剂稀释法在婴幼儿胸部增强CT检查中的应用
12
作者 边传振 张朋 朱明水 《影像科学与光化学》 CAS 2024年第3期264-268,共5页
目的:探讨通过生理盐水稀释对比剂,以降低儿童胸部增强CT检查对比剂浓度和剂量。方法:前瞻性搜集行胸部CT增强检查的0~3岁患儿100例,随机分配到A、B两组,使用注碘克沙醇(规格:320 mgI/mL)对比剂进行增强检查,A组对比剂用量为2 mL/kg, B... 目的:探讨通过生理盐水稀释对比剂,以降低儿童胸部增强CT检查对比剂浓度和剂量。方法:前瞻性搜集行胸部CT增强检查的0~3岁患儿100例,随机分配到A、B两组,使用注碘克沙醇(规格:320 mgI/mL)对比剂进行增强检查,A组对比剂用量为2 mL/kg, B组对比剂采用生理盐水稀释为A组浓度的60%,3 mL/kg,其余扫描条件均相同。测量两组患儿增强图像主动脉弓处、降主动脉处及肺动脉干处CT值,测量主动脉弓层面竖脊肌CT值和CT值标准差(SD)值,计算SNR和CNR,并对两组患儿的图像质量进行主观评分。后对A、B两组患儿的CT值、SNR、CNR、主观评分、辐射剂量、对比剂剂量进行对比分析。结果:B组患儿主动脉弓、降主动脉和肺动脉干处CT值分别为(336.4±11.7)HU、(347.2±10.6)HU和(365.5±12.3)HU,均低于A组同感兴趣区测量值[(464.3±13.1)HU、(485.4±12.9)HU和(492.2±11.7)HU],差异有统计学意义(t=15.5、20.6、12.8;P均<0.001);B组患儿SNR和CNR分别为44.7±4.6和35.6±3.9,均低于A组同感兴趣区测量值(53.2±5.1和42.7±4.4),差异有统计学意义(t=7.12、6.37;P均<0.001);B组患儿图像质量主观评分低于A组(P<0.001);A组患儿的CTDIVOL[(1.91±0.18)mGy]、DLP[(56.41±3.53)mGy·cm]和B组CTDIVOL[(1.89±0.16)mGy]、DLP[(53.17±4.05)mGy·cm]间的差异均无统计学意义(t=0.18、1.48;P=0.86、0.15);B组患儿对比剂剂量[(21.75±2.73)mL]低于A组[(15.55±2.09)mL),差异有统计学意义(t=6.02,P<0.001)。结论:在婴幼儿胸部CT增强检查时,将碘克沙醇(规格:320 mgI/mL)浓度降低至60%,能够得到满足临床需求的图像质量且能降低注入患儿体内对比剂剂量,降低患儿肾损伤风险,有一定推广价值。 展开更多
关键词 婴幼儿 对比剂 胸部CT 辐射剂量
下载PDF
双低剂量冠状动脉CTA应用价值研究
13
作者 薛贞龙 焦志云 《影像研究与医学应用》 2024年第8期43-46,共4页
目的:探讨使用低辐射剂量、低对比剂剂量的双低技术方案在第三代双源CT冠状动脉成像中对图像质量及辐射剂量的影响。方法:收集扬州大学附属医院2023年7月—2023年12月行冠状动脉计算机体层血管成像(CTA)检查的70例患者,随机分为低管电压... 目的:探讨使用低辐射剂量、低对比剂剂量的双低技术方案在第三代双源CT冠状动脉成像中对图像质量及辐射剂量的影响。方法:收集扬州大学附属医院2023年7月—2023年12月行冠状动脉计算机体层血管成像(CTA)检查的70例患者,随机分为低管电压70 kVp图像(A组)与120 kVp正常管电压(B组)两组进行比较。结果:A组计量长度乘积(DLP)、有效剂量(ED)、容积CT剂量指数(CTDI vol)低于B组,差异均具有统计学意义(P<0.05),A组平均碘摄入量低于B组,差异具有统计学意义(P<0.05)。两组图像质量主观评分差异无统计学意义(P>0.05)。两组患者血管噪声、信噪比(SNR)及对比度噪声比(CNR)在冠状动脉左主干差异均有统计学意义(P<0.05);两组患者血管CT值、噪声、SNR及CNR在右冠状动脉、左前降支及左回旋支差异均无统计学意义(P>0.05)。结论:双低冠状动脉CTA技术可在保证影像质量的前提下大幅度减少病人的辐射剂量及对比剂用量。 展开更多
关键词 CTA 冠状动脉 辐射剂量 对比剂剂量
下载PDF
个性化对比剂剂量在胸腹主动脉CTA触发扫描中的应用研究
14
作者 谭志明 黎丽 +1 位作者 周懿君 崔济钧 《智慧健康》 2024年第3期61-64,共4页
目的 探讨个性化对比剂剂量在胸腹主动脉CTA触发扫描中的应用价值。方法 选择2022年1月—2023年1月于粤北人民医院行胸腹主动脉CTA检查的患者100例为研究对象,按照随机数字表法分成对照组和观察组,每组50例。对照组、观察组分别给予常... 目的 探讨个性化对比剂剂量在胸腹主动脉CTA触发扫描中的应用价值。方法 选择2022年1月—2023年1月于粤北人民医院行胸腹主动脉CTA检查的患者100例为研究对象,按照随机数字表法分成对照组和观察组,每组50例。对照组、观察组分别给予常规剂量对比剂和个性化剂量对比剂。对比两组胸腹主动脉主观阅片结果、CT值及不良反应。结果 观察组胸腹主动脉主观阅片评价优于对照组,差异有统计学意义(P<0.05);两组L2水平腹主动脉、T7水平胸主动脉、主动脉弓、主动脉分叉处的CT值比较差异无统计学意义(P>0.05);观察组不良反应发生率较对照组低(P<0.05)。结论 根据体质量制定的个性化对比剂剂量在胸腹主动脉CTA触发扫描中具有较高的应用价值,可获得满足诊断质量的图像,且安全性好。 展开更多
关键词 胸腹主动脉 个性化对比剂剂量 CT血管造影 不良反应
下载PDF
L-LWiDose^4技术在新生儿先天性心脏病CT血管成像中的临床应用 被引量:5
15
作者 徐雷 陈博 +2 位作者 陈廷港 吴爱琴 程建敏 《温州医科大学学报》 CAS 2019年第3期189-193,共5页
目的:探讨低X线辐射剂量及低碘浓度等渗对比剂联合iDose^4迭代重建技术(L-LWiDose^4)在新生儿先天性心脏病CT血管成像(CTA)中的可行性。方法:前瞻性收集2015年1月至2018年3月温州医科大学附属第二医院育英儿童医院新生儿科需行心脏CTA... 目的:探讨低X线辐射剂量及低碘浓度等渗对比剂联合iDose^4迭代重建技术(L-LWiDose^4)在新生儿先天性心脏病CT血管成像(CTA)中的可行性。方法:前瞻性收集2015年1月至2018年3月温州医科大学附属第二医院育英儿童医院新生儿科需行心脏CTA检查的连续102例患者,随机分为2组,采用不同的扫描方案:常规组(A组)53例,采用100 kVp、100 mAs、碘海醇(350 mg I/mL),重建方式为滤波反投影(FBP)算法;实验组49例,采用80 kVp、80 mAs、碘克沙醇(270 mg I/mL),根据iDose^4迭代算法可以得到i Dose4-1~i Dose4-7 7组图像,选取iDose^4-2~i Dose^4-6 5组图像,分别记为B组、C组、D组、E组、F组。依据新生儿体质量采取不同的对比剂注射剂量并计算碘摄入量。测量主动脉弓、气管分叉水平降主动脉、肺动脉干及主动脉弓层面两侧胸大肌和竖脊肌CT值,测量气管分叉层面周围空气CT值的标准差(SD),记为背景噪声,计算信噪比(SNR)和对比噪声比(CNR),并对图像质量进行主观评价。记录容积CT剂量指数(CTDIvol) 和剂量长度乘积(DLP),并计算有效剂量(ED)和体型特异性剂量评估(SSDE)。以手术或心导管造影为"金标准",统计并比较各组CTA检查的诊断符合率。结果:实验组CTDIvol、SSDE、DLP、ED较常规组分别降低了57.08%、56.62%、58.31%、56.97%(P<0.05)。常规组、实验组对比剂碘摄入量分别为(1.83±1.27)g和(1.61±1.36)g,差异有统计学意义(P<0.05)。B组、F组图像客观评价不及A组、C组、D组、E组(P<0.05)。A组、D组、E组图像主观评价差异无统计学意义。常规组、实验各组诊断符合率分别为98.6%、81.6%、87.7%、97.9%、97.9%、96.9%,差异无统计学意义(P>0.05)。结论:80 kVp、80 mAs、碘克沙醇(270 mg I/mL)联合iDose^4迭代重建技术新生儿先天性心脏病CTA检查,在降低患者的电离辐射剂量和对比剂碘剂量的同时,其图像质量能够满足临床诊断需要。 展开更多
关键词 辐射剂量 非离子型碘对比剂 先天性心脏病 迭代重建 体层摄影术 X线计算机
下载PDF
血清LAPTM4B-35及DKK1联合低剂量超声造影在肝肿瘤良恶性诊断中的应用价值
16
作者 徐鹏 于德洋 +2 位作者 董茹婷 王宁 王磊 《医学研究与战创伤救治》 CAS 北大核心 2024年第1期53-57,共5页
目的探讨溶酶体相关4次跨膜蛋白B-35(LAPTM4B-35)、Dickkopf相关蛋白1(DKK1)在肝肿瘤血清中的表达以及联合低剂量超声造影在肝肿瘤良恶性诊断中的应用价值。方法收集2021年1月至2022年8月青岛市中心医院急诊创伤外科进行治疗的160例肝... 目的探讨溶酶体相关4次跨膜蛋白B-35(LAPTM4B-35)、Dickkopf相关蛋白1(DKK1)在肝肿瘤血清中的表达以及联合低剂量超声造影在肝肿瘤良恶性诊断中的应用价值。方法收集2021年1月至2022年8月青岛市中心医院急诊创伤外科进行治疗的160例肝肿瘤患者临床资料。根据病理学结果,将患者分为良性组(n=74)和恶性组(n=86)。比较两组血清LAPTM4B-35、DKK1水平及低剂量超声造影指标;多因素Logistic回归分析肝恶性肿瘤的影响因素;ROC曲线分析血清LAPTM4B-35、DKK1联合低剂量超声造影对肝恶性肿瘤的诊断效能。结果恶性组患者血清LAPTM4B-35、DKK1表达水平均高于良性组(P<0.05)。恶性组达峰时间低于良性组(P<0.05),峰值强度显著高于良性组(P<0.05)。多因素Logistic回归分析,结果显LAPTM4B-35、DKK1、达峰时间、峰值强度是发生肝恶性肿瘤的影响因素(P<0.05)。ROC曲线显示,血清LAPTM4B-35、DKK1、低剂量超声造影联合检测诊断肝恶性肿瘤的AUC为0.960,敏感性为89.53%,特异性为91.89%,优于其各自单独预测(Z两者联合-LAPTM4B-35=5.116、Z两者联合-DKK1=4.986、Z两者联合-达峰时间=4.657、Z两者联合-峰值强度=4.214,P<0.05)。结论肝肿瘤恶性患者血清LAPTM4B-35、DKK1表达水平显著升高,联合低剂量超声造影在肝恶性肿瘤的诊断中具有较高的应用价值。 展开更多
关键词 溶酶体相关4次跨膜蛋白B-35 Dickkopf相关蛋白1 低剂量超声造影 肝肿瘤 良恶性诊断
下载PDF
基于能谱CT虚拟平扫与常规平扫在肺内部分实性结节图像质量的对照研究
17
作者 洪静静 文戈 +3 位作者 张飞 张莲莲 刘迪斯 黄伟康 《分子影像学杂志》 2024年第5期528-532,共5页
目的探讨双能量CT(DECT)获得的虚拟非对比增强(VNC)图像在评估肺内部分实性结节(PSN)方面的可行性,并与真实非增强(TNC)图像质量进行比较。方法回顾性收集我院2022年1月~2023年1月46例孤立性肺结节患者,同时行TNC扫描和增强DECT扫描(动... 目的探讨双能量CT(DECT)获得的虚拟非对比增强(VNC)图像在评估肺内部分实性结节(PSN)方面的可行性,并与真实非增强(TNC)图像质量进行比较。方法回顾性收集我院2022年1月~2023年1月46例孤立性肺结节患者,同时行TNC扫描和增强DECT扫描(动脉期和静脉期),并根据双期DECT重建双期VNC图像。在双期VNC和TNC图像中测量PSN和同侧竖脊肌的CT值、噪声及病变直径,计算PSN的信噪比和对比度噪声比。记录TNC和VNC模式下的有效辐射剂量。由2位经验丰富的放射科医生使用5分量表进行主观评分。采用非参数检验比较不同扫描阶段图像的主观、客观参数和有效辐射剂量,采用Kappa检验用于评估两位医生主观评分的一致性。结果动、静脉期VNC与TNC图像的客观评价指标(直径、CT值、噪声、信噪比、对比度噪声比)的差异无统计学意义(P>0.05)。TNC图像主观评分均值最高,静脉期VNC图像次之,动脉期主观评分最低,3组评分差异有统计学意义(P<0.001),但双期VNC均满足诊断要求。2位医生主观评分一致性较强(0.63~0.73)。VNC代替TNC约降低30%的辐射剂量。结论双瞬切能谱增强静脉期虚拟平扫技术能够提供与常规平扫相似的图像质量,且能显著减少患者辐射剂量,尤其适用于需要多次复查的患者。 展开更多
关键词 部分实性结节 虚拟平扫 能谱CT 辐射剂量 图像质量
下载PDF
低管电压、低对比剂用量及浓度联合快速迭代重建技术(iDose)在头颈CTA中的应用 被引量:2
18
作者 郭文强 《辽东学院学报(自然科学版)》 CAS 2018年第4期253-258,共6页
60例头颈部CTA受检者随机等分为双低组和对照组。双低组采用100 kV的管电压、浓度为270 mgI/mL的对比剂50 mL联合应用快速迭代重建算法,对照组采用120 kV的管电压、浓度为370mgI/mL的对比剂50 mL。比较两组头颈部血管内CT值、噪声(SD)、... 60例头颈部CTA受检者随机等分为双低组和对照组。双低组采用100 kV的管电压、浓度为270 mgI/mL的对比剂50 mL联合应用快速迭代重建算法,对照组采用120 kV的管电压、浓度为370mgI/mL的对比剂50 mL。比较两组头颈部血管内CT值、噪声(SD)、CNR、SNR、图像质量评分、CTDIvol、DLP,评价其图像质量及辐射剂量。结果显示,双低组颈部血管CT值略低于对照组,颅内血管CT值略高于对照组;两组图像质量均满足临床诊断需要;双低组联合快速迭代重建技术(iDose),噪声(SD)较对照组减低,SNR、CNR较对照组增高;双低组辐射剂量较对照组明显降低,CTDIvol、DLP分别降低约51%、56%。因此,低管电压、低对比剂剂量及浓度联合应用快速迭代重建技术(iDose)进行头颈部CTA检查是可行的,图像质量能完全满足临床诊断需要,而且辐射剂量明显降低。 展开更多
关键词 低管电压 对比剂 快速迭代重建技术 辐射剂量
下载PDF
双低剂量肺动脉血管造影(CTPA)成像技术在诊断肺动脉栓塞的可行性研究 被引量:1
19
作者 汪劭川 曾一红 +2 位作者 孙政文 许馨予 成启华 《中国CT和MRI杂志》 2024年第1期68-70,共3页
目的探讨64排螺旋CT在低碘对比剂剂量和低辐射剂量下施行肺动脉血管造影(CTPA)成像技术在诊断肺动脉栓塞的可行性。方法选取本院2021-2023年度疑似患有肺动脉栓塞的受检者60例。所有受检者均接受CTPA检查,将受检者分为常规剂量组管电压1... 目的探讨64排螺旋CT在低碘对比剂剂量和低辐射剂量下施行肺动脉血管造影(CTPA)成像技术在诊断肺动脉栓塞的可行性。方法选取本院2021-2023年度疑似患有肺动脉栓塞的受检者60例。所有受检者均接受CTPA检查,将受检者分为常规剂量组管电压120KV,碘对比剂剂量30~40ml(30例)和低剂量组管电压100KV,碘对比剂剂量15mL(30例)均使用非离子型水溶性碘对比剂碘美普尔(400gl/100mL)。两组受检者均憋气扫描完成,比较两组受检者的CT值、背景噪声、信噪比(signal to noise ratio,SNR)、容积CT剂量指数(computed tomography dose index,CTDIvoI)、剂量长度乘积(dose length product,DLP)。结果低剂量组与常规剂量组的CT值、背景噪声、SNR、DLP、CTDIvoI相比有差异有统计学意义(P<0.01)。低剂量组与常规剂量组的图像质量相比没有统计学意义(P>0.05)。低剂量组与常规剂量组相比,其动脉栓塞检出率没有统计学意义(P>0.05)。结论在肺动脉血管造影(CTPA)成像上选用双低剂量,能够减少受检者发生碘对比剂肾病(contrast induced nephronpathy,CIN)并降低所承受到的辐射剂量,且双低剂量CTPA成像对肺动脉栓塞检查可行性高值得临床应用及推广。 展开更多
关键词 肺动脉栓塞 肺动脉血管造影CTPA 双低剂量 碘对比剂 计算机体层摄影技术
下载PDF
低浓度对比剂对头颈部CTA患者受辐射剂量、对比剂肾损伤发生率的影响
20
作者 蔡敏华 崔毛毛 叶俊杰 《中国CT和MRI杂志》 2024年第2期52-54,共3页
目的分析低浓度对比剂对头颈部CT血管成像(CTA)患者受辐射剂量、对比剂肾损伤(CIN)发生率的影响。方法将2022年1月~2022年12月入院的68例行头颈部CTA检查者随机分为低浓度组(34例)与高浓度组(34例),低浓度组使用对比剂为碘克沙醇320mgl/... 目的分析低浓度对比剂对头颈部CT血管成像(CTA)患者受辐射剂量、对比剂肾损伤(CIN)发生率的影响。方法将2022年1月~2022年12月入院的68例行头颈部CTA检查者随机分为低浓度组(34例)与高浓度组(34例),低浓度组使用对比剂为碘克沙醇320mgl/mL,管电压为100kVp,高浓度组对比剂为碘海醇350mg l/mL,管电压为120kVp。比较两组图像主观评分及客观图像质量[各部位CT值、信噪比(SNR)、对比噪声比(CNR)]差异,记录两组辐射剂量[CT容积剂量指数(CTDIvol)、剂量长度乘积(DLP)、有效剂量(ED)]及CIN等不良反应发生率,并评估两组超重及肥胖人群的SNR、CNR。结果两组图像主观评分比较,差异无统计学意义(P>0.05),2名放射科医生对两组图像判断的一致性均良好(P<0.05)。低浓度组升主动脉、颈总动脉、大脑中动脉测量的CT值及SNR、CNR均高于高浓度组(P<0.05),CTDIvol、DLP、ED则低于高浓度组(P<0.05)。两组不良反应及超重、肥胖人群各血管SNR、CNR比较,差异无统计学意义(P>0.05)。结论碘克沙醇320mgl/mL碘对比剂及100kVp管电压,结合三维自适应迭代剂量降低算法重建,可实现高图像质量及低辐射剂量的双重优点,对降低CIN发生风险也有利,但对于超重、肥胖受检者可能不适用。 展开更多
关键词 CTA 头颈部 对比剂 低浓度 图像质量 辐射剂量 对比剂肾损伤
下载PDF