期刊文献+
共找到1,255篇文章
< 1 2 63 >
每页显示 20 50 100
Anti-Stokes/Stokes temperature calibration and its application in laser-heating diamond anvil cells
1
作者 赵旻旻 吴彬彬 +1 位作者 刘静仪 雷力 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第9期51-59,共9页
Anti-Stokes/Stokes Raman peak intensity ratio was used to infer sample temperatures,but the influence factors of system correction factors were not clear.Non-contact in-situ anti-Stokes/Stokes temperature calibration ... Anti-Stokes/Stokes Raman peak intensity ratio was used to infer sample temperatures,but the influence factors of system correction factors were not clear.Non-contact in-situ anti-Stokes/Stokes temperature calibration was carried out for up to 1500 K based on six different samples under two excitation light sources(±50 K within 1000 K,±100 K above1000 K),and the system correction factorγwas systematically investigated.The results show that the correction factorγof anti-Stokes/Stokes thermometry is affected by the wavelength of the excitation light source,Raman mode peak position,temperature measurement region and other factors.The anti-Stokes/Stokes thermometry was applied to the laser-heating diamond anvil cell(LHDAC)experiment to investigate the anharmonic effect of h BN under high temperature and high pressure.It is concluded that the strong anharmonic effect caused by phonon scattering at low pressure gradually changes into the predominance of localized molecular lattice thermal expansion at high pressure. 展开更多
关键词 Stokes/anti-Stokes Raman spectroscopy temperature calibration laser-heating diamond anvil cell(LHDAC) anharmonic effect
原文传递
Design and Realization of a Portable Temperature Sensor Calibrator
2
作者 Wei Mingming Liu Yushan Zhang Yunhao 《Meteorological and Environmental Research》 CAS 2018年第2期12-15,19,共5页
Due to the complex erection environment of various types of automatic stations,the provincial meteorological inspection department is difficult to carry out this work in terms of equipment or staffing. For this reason... Due to the complex erection environment of various types of automatic stations,the provincial meteorological inspection department is difficult to carry out this work in terms of equipment or staffing. For this reason,a portable temperature sensor calibrator was developed,and it uses semiconductor refrigeration technology to increase and decrease temperature quickly. It uses an intelligent PID temperature controller as a control device to provide a stable temperature environment; it is small,light and easy to operate,and it provides technical support for the calibration of temperature sensors. The structure and working principle of this equipment were analyzed,and its performance was tested. All the indicators could meet the requirements of field calibration. The calibrator will provide a strong guarantee for the reliability of temperature data obtained at automatic meteorological stations. 展开更多
关键词 Automatic meteorological stations temperature sensors temperature calibration temperature detection
下载PDF
Dynamic Calibration of the Cutting Temperature Sensor of NiCr/NiSi Thin-film Thermocouple 被引量:16
3
作者 CUI Yunxian YANG Deshun +2 位作者 JIA Ying ZENG Qiyong SUN Baoyuan 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2011年第1期73-77,共5页
In high-speed cutting, natural thermocouple, artificial thermocouple and infrared radiation temperature measurement are usually adopted for measuring cutting temperature, but these methods have difficulty in measuring... In high-speed cutting, natural thermocouple, artificial thermocouple and infrared radiation temperature measurement are usually adopted for measuring cutting temperature, but these methods have difficulty in measuring transient temperature accurately of cutting area on account of low response speed and limited cutting condition. In this paper, NiCr/NiSi thin-film thermocouples(TFTCs) are fabricated according to temperature characteristic of cutting area in high-speed cutting by means of advanced twinned microwave electro cyclotron resonance(MW-ECR) plasma source enhanced radio frequency(RF) reaction non-balance magnetron sputtering technique, and can be used for transient cutting temperature measurement. The time constants of the TFTCs with different thermo-junction film width are measured at four kinds of sampling frequency by using Ultra-CFR short pulsed laser system that established. One-dimensional unsteady heat conduction model is constructed and the dynamic performance is analyzed theoretically. It can be seen from the analysis results that the NiCr/NiSi TFTCs are suitable for measuring transient temperature which varies quickly, the response speed of TFTCs can be obviously improved by reducing the thickness of thin-film, and the area of thermo-junction has little influence on dynamic response time. The dynamic calibration experiments are made on the constructed dynamic calibration system, and the experimental results confirm that sampling frequency should be larger than 50 kHz in dynamic measurement for stable response time, and the shortest response time is 0.042 ms. Measurement methods and devices of cutting heat and cutting temperature measurement are developed and improved by this research, which provide practical methods and instruments in monitoring cutting heat and cutting temperature for research and production in high-speed machining. 展开更多
关键词 thin-film thermocouple cutting temperature sensor dynamic calibration one-dimensional unsteady heat conduction response time
下载PDF
Verification and recalibration of HY-2A microwave radiometer brightness temperature 被引量:2
4
作者 ZHAO Yili LI Huimin +1 位作者 CHEN Chuntao ZHU Jianhua 《Journal of Oceanology and Limnology》 SCIE CAS CSCD 2019年第3期968-981,共14页
HY-2A is the first one of the Chinese HY-2 ocean satellite series carrying a microwave radiometer(RM)to measure sea surface temperature,sea surface wind speed,atmospheric water vapor,cloud liquid water content,and rai... HY-2A is the first one of the Chinese HY-2 ocean satellite series carrying a microwave radiometer(RM)to measure sea surface temperature,sea surface wind speed,atmospheric water vapor,cloud liquid water content,and rain rate.We verified the RM level 1B brightness temperature(T B)to retrieve environmental parameters.In the verification,TB that simulated using the ocean-atmosphere radiative transfer model(RTM)was used as a reference.The total bias and total standard deviation(SD)of the RM level 1B TB,with reference to the RTM simulation,ranged-20.6-4.38 K and 0.7-2.93 K,respectively.We found that both the total bias and the total SD depend on the frequency and polarization,although the values for ascending and descending passes are different.In addition,substantial seasonal variation of the bias was found at all channels.The verification results indicate the RM has some problems regarding calibration,e.g.,correction of antenna spillover and antenna physical emission,especially for the 18.7-GHz channel.Based on error analyses,a statistical recalibration algorithm was designed and recalibration was performed for the RM level 1B TB.Validation of the recalibrated TB indicated that the quality of the recalibrated RM level 1B TB was improved significantly.The bias of the recalibrated T B at all channels was reduced to<0.4 K,seasonal variation was almost eradicated,and SD was diminished(i.e.,the SD of the 18.7-GHz channel was reduced by more than 0.5K). 展开更多
关键词 HY-2A MICROWAVE RADIOMETER BRIGHTNESS temperature(TB) VERIFICATION calibration
下载PDF
In-situ ultrasonic calibrations of pressure and temperature in a hinge-type double-stage cubic large volume press 被引量:1
5
作者 Qingze Li Xiping Chen +3 位作者 Lei Xie Tiexin Han Jiacheng Sun Leiming Fang 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第6期272-277,共6页
Here,simultaneous in-situ calibration of pressures and temperatures was performed in a hinge-type second-stage cubic large volume press(LVP)up to 15 GPa and 1400 K by an acoustic travel-time approach.Based on the rece... Here,simultaneous in-situ calibration of pressures and temperatures was performed in a hinge-type second-stage cubic large volume press(LVP)up to 15 GPa and 1400 K by an acoustic travel-time approach.Based on the recently reported P-tSand P-T-tP-tSequations for Al2O3buffer rod,the cell pressures and temperatures in the chamber of LVP were insitu determined,in comparison with those by conventional off-line(or fixed-points)pressure calibration method and direct thermocouple measurement,respectively.It is found that the cell pressures of the LVP chamber are significantly reduced after annealing at simultaneous high pressures and high temperatures,owing to the stress relaxation as accumulate in the LVP chamber.This acoustic travel-time method is verified to be a good way for precise determination of thermal(cell)pressures at high temperature conditions,and is of great importance and necessity to conduct in-situ physical property measurements under extreme high P-T conditions,especially when the precious synchrotron x-ray/neutron diffraction beams are not available. 展开更多
关键词 cubic press simultaneous in-situ calibration of pressures and temperatures acoustic travel-time high pressure and high temperature
原文传递
The Study of In-Orbit Calibration Accuracy of NOAA Satellite Infrared Sounder and Its Effect on Temperature Profile Retrievals 被引量:1
6
作者 董超华 刘全华 +1 位作者 黎光清 张凤英 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 1990年第2期211-219,共9页
The calibration accuracy of High Resolution Infrared Radiation Sounder Mod. 2 (HIRS / 2) on NOAA-10 satellite is analyzed in this paper. The non-linear effect in the linear calibration curve induces a deviation of 1.5... The calibration accuracy of High Resolution Infrared Radiation Sounder Mod. 2 (HIRS / 2) on NOAA-10 satellite is analyzed in this paper. The non-linear effect in the linear calibration curve induces a deviation of 1.5 degrees (k) of brightness temperature in the tenth channel (8.3 um, water vapor absorption) of the HIRS/2 and the non-linear effect affects the other channels to a different extent. Based on analyzing non- linearity in two-point calibration curve, a tri-point calibration equation is given. A numerical test of effects of the linear and non-linear calibration models on the accuracy of atmospheric temperature retrievals is carried out. 展开更多
关键词 In The Study of In-Orbit calibration Accuracy of NOAA Satellite Infrared Sounder and Its Effect on temperature Profile Retrievals NOAA CLI
下载PDF
Temperature control for thermal treatment of aluminum alloy in a large-scale vertical quench furnace 被引量:2
7
作者 沈玲 贺建军 +1 位作者 喻寿益 桂卫华 《Journal of Central South University》 SCIE EI CAS CSCD 2016年第7期1719-1728,共10页
The temperature control of the large-scale vertical quench furnace is very difficult due to its huge volume and complex thermal exchanges. To meet the technical requirement of the quenching process, a temperature cont... The temperature control of the large-scale vertical quench furnace is very difficult due to its huge volume and complex thermal exchanges. To meet the technical requirement of the quenching process, a temperature control system which integrates temperature calibration and temperature uniformity control is developed for the thermal treatment of aluminum alloy workpieces in the large-scale vertical quench furnace. To obtain the aluminum alloy workpiece temperature, an air heat transfer model is newly established to describe the temperature gradient distribution so that the immeasurable workpiece temperature can be calibrated from the available thermocouple temperature. To satisfy the uniformity control of the furnace temperature, a second order partial differential equation(PDE) is derived to describe the thermal dynamics inside the vertical quench furnace. Based on the PDE, a decoupling matrix is constructed to solve the coupling issue and decouple the heating process into multiple independent heating subsystems. Then, using the expert control rule to find a compromise of temperature rising time and overshoot during the quenching process. The developed temperature control system has been successfully applied to a 31 m large-scale vertical quench furnace, and the industrial running results show the significant improvement of the temperature uniformity, lower overshoot and shortened processing time. 展开更多
关键词 large-scale vertical quench furnace temperature calibration thermal dynamic model decoupling control
下载PDF
Research on sea surface temperature retrieval by the one-dimensional synthetic aperture microwave radiometer, 1D-SAMR 被引量:2
8
作者 Weihua Ai Mengyan Feng +1 位作者 Guanyu Chen Wen Lu 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2020年第5期115-122,共8页
Due to the low spatial resolution of sea surface temperature(T_S)retrieval by real aperture microwave radiometers,in this study,an iterative retrieval method that minimizes the differences between brightness temperatu... Due to the low spatial resolution of sea surface temperature(T_S)retrieval by real aperture microwave radiometers,in this study,an iterative retrieval method that minimizes the differences between brightness temperature(T_B)measured and modeled was used to retrieve sea surface temperature with a one-dimensional synthetic aperture microwave radiometer,temporarily named 1 D-SAMR.Regarding the configuration of the radiometer,an angular resolution of 0.43°was reached by theoretical calculation.Experiments on sea surface temperature retrieval were carried out with ideal parameters;the results show that the main factors affecting the retrieval accuracy of sea surface temperature are the accuracy of radiometer calibration and the precision of auxiliary geophysical parameters.In the case of no auxiliary parameter errors,the greatest error in retrieved sea surface temperature is obtained at low T_S scene(i.e.,0.7106 K for the incidence angle of 35°under the radiometer calibration accuracy of0.5 K).While errors on auxiliary parameters are assumed to follow a Gaussian distribution,the greatest error on retrieved sea surface temperature was 1.3305 K at an incidence angle of 65°in poorly known sea surface wind speed(W)(the error on W of 1.0 m/s)over high W scene,for the radiometer calibration accuracy of 0.5 K. 展开更多
关键词 sea surface temperature synthetic aperture microwave radiometer retrieval accuracy radiometer calibration accuracy auxiliary parameter errors high spatial resolution
下载PDF
A research on high-temperature permittivity and loss tangent of low-loss dielectric by resonant-cavity technique 被引量:1
9
作者 曹茂盛 Hou Zhiling +1 位作者 Shi Xiaoling Wang Fuchi 《High Technology Letters》 EI CAS 2007年第3期279-282,共4页
Resonant-cavity technique was introduced to measure the permittivity and loss tangent of low-loss dielectrics. The dielectric properties at 9-10 GHz are measured accurately at the temperature up to 800 ℃ by the reson... Resonant-cavity technique was introduced to measure the permittivity and loss tangent of low-loss dielectrics. The dielectric properties at 9-10 GHz are measured accurately at the temperature up to 800 ℃ by the resonant cavity technique. The only electrical parameters that need to be measured are quality factors (Q) and resonant length (L) of resonant cavity loaded and unloaded with dielectric sample. Moreover, the error caused by thermal expansion effect was resolved by error analysis and experimental calibration. 展开更多
关键词 high temperature resonant cavity method PERMITTIVITY errors calibration
下载PDF
基于总温探针的高精度总焓测量方法优化研究
10
作者 朱新新 隆永胜 +3 位作者 赵顺洪 杨远剑 李泽禹 赵文峰 《实验流体力学》 CAS CSCD 北大核心 2024年第5期107-114,共8页
为提高中低焓来流的总焓测量精准度,以铱铑铱热电偶为测温元件研制了一种总温探针。基于流热耦合计算模型对该探针各部件尺寸参数进行了优化设计,使得总温探针的复温率不低于0.9;计算和试验结果表明铱铑铱热电偶结点温度会随着热电偶后... 为提高中低焓来流的总焓测量精准度,以铱铑铱热电偶为测温元件研制了一种总温探针。基于流热耦合计算模型对该探针各部件尺寸参数进行了优化设计,使得总温探针的复温率不低于0.9;计算和试验结果表明铱铑铱热电偶结点温度会随着热电偶后端面温度和屏蔽罩温度的升高而缓慢升高,导致不同测量时间段下得到的总温值不同,因此必须规定测量时间段并进行溯源校准。为此,借助一种新设计的加热器弧室总温探针,将应用于电弧风洞超声速流场的总温探针向亚声速流场总温校准装置进行了溯源校准。在电弧风洞中开展了总焓测量验证试验,采用基于精度极限和偏差极限的不确定度评估方法,计算了总焓测量结果的不确定度。结果表明:所研制的总温探针具有较高的总焓测量精准度,就本文试验结果而言,其重复性精度约为3%,不确定度约为6.4%。 展开更多
关键词 总焓测量 总温探针 流热耦合 溯源校准 不确定度分析
下载PDF
用于定标海表测温辐射计的镓黑体辐射源
11
作者 张凯临 赵治园 +2 位作者 任传运 杨铭伦 曲利芹 《光子学报》 EI CAS CSCD 北大核心 2024年第1期118-128,共11页
设计了镓黑体对海表测温辐射计进行定标。首先,介绍了该黑体的结构与工作原理,对黑体发射率进行仿真,并开展发射率的测量实验,讨论其不确定度的来源。然后,开展了电加热和水浴加热下镓的相变复现实验,讨论电加热功率对镓相变复现的影响... 设计了镓黑体对海表测温辐射计进行定标。首先,介绍了该黑体的结构与工作原理,对黑体发射率进行仿真,并开展发射率的测量实验,讨论其不确定度的来源。然后,开展了电加热和水浴加热下镓的相变复现实验,讨论电加热功率对镓相变复现的影响。最后,通过红外海面温度自主辐射计实验对该黑体进行验证。结果表明:该黑体基于蒙特卡罗软件仿真的发射率优于0.9988,实验测得的黑体辐射源发射率结果与仿真结果较为吻合,测量重复性(标准偏差)达0.1%;相变温度坪台的复现性均优于±0.03 K;相变温坪附近时,红外海面温度自主辐射计和FLUKE 1524测温仪测得的黑体腔附近温度的数据差值均在±0.15 K以内。设计的镓黑体可以应用到海表测温辐射计进行校准,为发展自主知识产权的海表测温设备提供校准源。 展开更多
关键词 红外测温 黑体辐射源 镓固定点 船载辐射计定标
下载PDF
小惯性热电偶动态校准及频域分析
12
作者 赵俭 《计量学报》 CSCD 北大核心 2024年第5期666-670,共5页
发动机进气温度畸变影响发动机的稳定性,通常使用小惯性热电偶来测量其快速变化的气流温度。为准确全面获取小惯性热电偶的动态特性,提出了一种小惯性热电偶的动态特性校准及评价方法,并阐述了小惯性热电偶动态校准装置的构建、校准试... 发动机进气温度畸变影响发动机的稳定性,通常使用小惯性热电偶来测量其快速变化的气流温度。为准确全面获取小惯性热电偶的动态特性,提出了一种小惯性热电偶的动态特性校准及评价方法,并阐述了小惯性热电偶动态校准装置的构建、校准试验以及频域分析。采用脉冲激光器与校准风洞相结合的小惯性热电偶动态校准方法,通过幅频特性和相频特性分析,拓展了小惯性热电偶的动态特性评价方法。用该校准方法对小惯性热电偶进行动态校准,结果A类相对不确定度最大值由7.2%减小到2.4%,可应用于30 ms以下量级快响应温度传感器的动态校准,为发动机进气温度畸变等高频动态温度测量提供技术参考。 展开更多
关键词 温度计量 小惯性热电偶 动态校准 温度畸变 脉冲激光器 校准风洞 发动机稳定性
下载PDF
连续热电偶检定炉的设计与研制
13
作者 王喆 余松林 王晓丹 《自动化与仪表》 2024年第3期117-120,159,共5页
连续热电偶是基于塞贝克效应制成的一种新型温度传感器。在校准连续热电偶时,热电偶检定炉是较为重要的热源之一。该研究在传统检定炉的基础之上设计四温区检定炉,通过对炉体和温度控制的改造,对多种控温模式的设计,研制出能够适用连续... 连续热电偶是基于塞贝克效应制成的一种新型温度传感器。在校准连续热电偶时,热电偶检定炉是较为重要的热源之一。该研究在传统检定炉的基础之上设计四温区检定炉,通过对炉体和温度控制的改造,对多种控温模式的设计,研制出能够适用连续热电偶等多种高温传感器校准的热源。 展开更多
关键词 温度计量 管式炉 热电偶检定炉 热电偶 连续热电偶
下载PDF
一种变焦红外成像测温方法
14
作者 李科 朱金华 +2 位作者 邵先军 孙子林 姜凯华 《激光与红外》 CAS CSCD 北大核心 2024年第8期1272-1276,共5页
以适合大风、高温等极端天气条件下使用的固定安装式变焦测温热像仪为背景,针对连续变焦热像仪的测温问题,提出了一种变焦红外成像测温方法,在文中给出的定焦热像仪工程测温方法基础上,扩展了焦距维度,构建了变焦热像仪测温的多项式模型... 以适合大风、高温等极端天气条件下使用的固定安装式变焦测温热像仪为背景,针对连续变焦热像仪的测温问题,提出了一种变焦红外成像测温方法,在文中给出的定焦热像仪工程测温方法基础上,扩展了焦距维度,构建了变焦热像仪测温的多项式模型,并通过最优化方法计算反演参数,从而得到不同焦距时的测温结果,进一步给出了变焦测温时的数据标定方法。基于高精度黑体对自主研发的变焦热像仪进行了数据标定,分析了不同焦距时的测温精度,并进行了实验室环境和户外环境的观测试验。试验结果表明,不同焦距都可获得高精度的测温结果,达到国标要求的±2℃精度。该项成果可以在各型变焦热像仪上推广应用,提高对高压线类远距离目标的测温精度。 展开更多
关键词 红外成像 连续变焦 数据标定 测温
下载PDF
自动化温度阻值关系校准系统设计及优化
15
作者 李毅华 姚金涛 +3 位作者 王志鹏 王坤 陆刚 韩佳乐 《计量与测试技术》 2024年第8期9-13,共5页
本文针对Pt100和热敏电阻在温度和温升测量中自动化程度低、耗时长、精度不足的问题,研究了Pt100阻值-温度关系和热敏电阻阻值变化量-温升关系,制定了一套温度校准方法,并设计搭建了温度校准系统。同时,结合校准方法与校准需求,开发了... 本文针对Pt100和热敏电阻在温度和温升测量中自动化程度低、耗时长、精度不足的问题,研究了Pt100阻值-温度关系和热敏电阻阻值变化量-温升关系,制定了一套温度校准方法,并设计搭建了温度校准系统。同时,结合校准方法与校准需求,开发了自动校准与数据处理程序。结果表明:该系统可实现全自动运行,提高了校准效率与精度,满足温度计高精度校准需求,提供了一种多类型、多温度点交叉校准的全自动控制校准方案。 展开更多
关键词 温度校准 热敏电阻 PT100 不确定度 自动化
下载PDF
恒温振荡培养箱校准方法的研究
16
作者 张佳仁 《现代科学仪器》 2024年第1期147-149,211,共4页
研究建立了恒温振荡培养箱的校准方法。通过对生产厂家和用户的调研,参考相关的国家标准、行业标准和校准规范,提出一种采用多通道温度计、转速表和位移传感器作为校准装置,校准恒温振荡培养箱的温度偏差、温度波动度、温度均匀度、振... 研究建立了恒温振荡培养箱的校准方法。通过对生产厂家和用户的调研,参考相关的国家标准、行业标准和校准规范,提出一种采用多通道温度计、转速表和位移传感器作为校准装置,校准恒温振荡培养箱的温度偏差、温度波动度、温度均匀度、振荡频率误差和振荡幅度误差的方法。选择代表性的恒温振荡培养箱,依据该校准方法对计量特性进行实验验证,验证结果符合指标要求。该方法促进了恒温振荡培养箱量值溯源的标准化和规范化,推动其校准规范的制定。 展开更多
关键词 恒温振荡培养箱 溯源 校准 验证
下载PDF
高低温试验箱温度偏差校准结果的测量不确定度评定
17
作者 赵婷婷 周昭亮 《实验室检测》 2024年第7期136-140,共5页
高低温试验箱可以为仪表及材料等提供相应的高低温环境,其温度场性能及测量不确定度是影响温度试验箱测量结果的重要指标,通过对温度偏差校准结果的不确定度评定和影响量分析,进一步了解高低温试验箱的计量性能、误差来源及减小误差影... 高低温试验箱可以为仪表及材料等提供相应的高低温环境,其温度场性能及测量不确定度是影响温度试验箱测量结果的重要指标,通过对温度偏差校准结果的不确定度评定和影响量分析,进一步了解高低温试验箱的计量性能、误差来源及减小误差影响的方法。依据GB/T 10592-2023《高低温试验箱技术条件》规定的校准方法选取满足测量要求的温度传感器,对高低温试验箱温度偏差进行校准。校准确认高低温试验箱温度场性能满足温度偏差±2℃的允差要求,测量不确定度满足1/3最大允许误差的技术指标要求。高低试验箱校准温度场性能良好,测量标准器选取短支A级铂热电阻满足校准要求且稳定性良好符合长时间交替温度的测量使用。 展开更多
关键词 高低温试验箱 温度偏差 校准 测量不确定度
下载PDF
深空探测超宽光谱定标黑体源研制 被引量:1
18
作者 董惠文 张家平 +3 位作者 练敏隆 肖大舟 王伟刚 鲁越晖 《光子学报》 EI CAS CSCD 北大核心 2024年第2期127-139,共13页
针对深空探测超宽光谱定标黑体源的关键技术问题,构建了一种基于优化微结构和纳米超黑涂层的深空探测星上黑体定标源。基于有限元方法仿真,验证了微锥结构不同宽高比与黑体发射率间的对应关系,确定了周期性线阵V槽结构相对于平面结构在... 针对深空探测超宽光谱定标黑体源的关键技术问题,构建了一种基于优化微结构和纳米超黑涂层的深空探测星上黑体定标源。基于有限元方法仿真,验证了微锥结构不同宽高比与黑体发射率间的对应关系,确定了周期性线阵V槽结构相对于平面结构在黑体发射率方面的提升作用。优化星上黑体源高发射率微结构,优选空间超黑高发射涂层,设计星上黑体源高精度测温系统,进而完成黑体源工程设计。最后,通过星上黑体源发射率计量及实验室辐射定标稳定性测试进行验证。检测结果表明,深空探测超宽光谱定标黑体源具有超宽光谱范围、高发射率、高温度稳定性等特点,其光谱范围为5~50μm,法向平均发射率为0.986,温度稳定性达到0.16 K。该定标黑体源可大幅提升高发射率辐射定标源的光谱范围,为深空探测载荷的在轨高精度星上辐射定标提供支撑。 展开更多
关键词 深空探测 定标 超宽光谱 高发射率 PID控温 高稳定性
下载PDF
采用两步式数字校准的低温漂松弛振荡器 被引量:1
19
作者 裴磊 韩佳利 +5 位作者 张程跃 齐欢欢 张杰 许江涛 王晓飞 张鸿 《西安交通大学学报》 EI CAS CSCD 北大核心 2024年第8期166-174,共9页
针对传统片上振荡器设计面临的时钟频率难以实现高精度校准的问题,提出基于二分搜索法的数字校准方法,实现了振荡频率校准并提高了校准的线性度。校准算法采用了粗校准加细校准的两步式校准过程,大大增加了频率校准范围。针对振荡频率... 针对传统片上振荡器设计面临的时钟频率难以实现高精度校准的问题,提出基于二分搜索法的数字校准方法,实现了振荡频率校准并提高了校准的线性度。校准算法采用了粗校准加细校准的两步式校准过程,大大增加了频率校准范围。针对振荡频率的温度漂移问题,提出了新的温度补偿方案,在传统一阶温度补偿的基础上,增加了亚阈值电流自补偿的高阶补偿机制,大大降低了温度变化对输出频率的影响。在校准电路的设计中,合理设置开关电阻阵列的温度系数以保证输出频率的校准不影响输出频率的温度稳定性。对振荡器版图提取了寄生参数,并进行了仿真,仿真结果表明:经过所提频率校准和温度补偿方案,典型情况下振荡频率误差小于0.04%;在-40~125℃温度范围内频率误差小于±0.12%;2.5~5.5 V电源电压范围内频率随电源电压变化误差小于±0.13%;电路工作电流为47.6μA,完成一次校准时长不超过2.7 ms。该振荡器可用于物联网、处理器等应用,可以取代片外晶体振荡器,能够降低系统成本和体积。 展开更多
关键词 松弛振荡器 高精度 两步式数字校准 高阶温度补偿
下载PDF
航空发动机叶片表面红外测温校准及温度场重构
20
作者 方弘毅 罗捷 +5 位作者 王登奎 杨建华 曾敏 邹远禄 胡南滔 杨志 《红外技术》 CSCD 北大核心 2024年第8期940-946,共7页
随着我国航空业的蓬勃发展,航空发动机技术取得了长足的进步。作为航空发动机的关键组件,航空发动机叶片的研制关乎全局。对其温度进行实时、精确的测量监控有助于推动航空发动机叶片相关技术的突破。本文提出了一种基于红外测温技术的... 随着我国航空业的蓬勃发展,航空发动机技术取得了长足的进步。作为航空发动机的关键组件,航空发动机叶片的研制关乎全局。对其温度进行实时、精确的测量监控有助于推动航空发动机叶片相关技术的突破。本文提出了一种基于红外测温技术的航空发动机叶片温度校准算法和温度场三维重构策略。该工作利用多层感知机网络的函数拟合能力,建立了对目标点精确温度与其周围温度分布的函数关系,并将红外测温的误差控制在1.24℃。在此基础上,采用投影法和三维点云法向量估计的创新策略,实现了二维红外图像到三维空间位置映射。该方法能从单视角红外图像得到温度场三维重构,重构过程简单,摆脱了对多视角图像的依赖。 展开更多
关键词 多层感知机 红外温度校准 温度场重建
下载PDF
上一页 1 2 63 下一页 到第
使用帮助 返回顶部