Hot water flooding is an effective way to develop heavy oil reservoirs.However,local channeling channels may form,possibly leading to a low thermal utilization efficiency and high water cut in the reservoir.The pore s...Hot water flooding is an effective way to develop heavy oil reservoirs.However,local channeling channels may form,possibly leading to a low thermal utilization efficiency and high water cut in the reservoir.The pore structure heterogeneity is an important factor in forming these channels.This study proposes a method that mixes quartz sand with different particle sizes to prepare weakly heterogeneous and strongly heterogeneous models through which hot water flooding experiments are conducted.During the experiments,computer tomography(CT)scanning identifies the pore structure and micro remaining oil saturation distribution to analyze the influence of the pore structure heterogeneity on the channeling channels.The oil saturation reduction and average pore size are divided into three levels to quantitatively describe the relationship between the channeling channel distribution and pore structure heterogeneity.The zone where oil saturation reduction exceeds 20%is defined as a channeling channel.The scanning area is divided into 180 equally sized zones based on the CT scanning images,and threedimensional(3D)distributions of the channeling channels are developed.Four micro remaining oil distribution patterns are proposed,and the morphology characteristics of micro remaining oil inside and outside the channeling channels are analyzed.The results show that hot water flooding is more balanced in the weakly heterogeneous model,and the oil saturation decreases by more than 20%in most zones without narrow channeling channels forming.In the strongly heterogeneous model,hot water flooding is unbalanced,and three narrow channeling channels of different lengths form.In the weakly heterogeneous model,the oil saturation reduction is greater in zones with larger pores.The distribution range of the average pore size is larger in the strongly heterogeneous model.The network remaining oil inside the channeling channels is less than outside the channeling channels,and the hot water converts the network remaining oil into cluster,film,and droplet remaining oil.展开更多
To investigate the macroscopic fatigue properties and the mesoscopic pore evolution characteristics of salt rock under cyclic loading,fatigue tests under different upper-limit stresses were carried out on salt rock,an...To investigate the macroscopic fatigue properties and the mesoscopic pore evolution characteristics of salt rock under cyclic loading,fatigue tests under different upper-limit stresses were carried out on salt rock,and the mesoscopic pore structures of salt rock before and after fatigue tests and under different cycle numbers were measured using CT scanning instrument.Based on the test results,the effects of the cycle number and the upper-limit stress on the evolution of cracks,pore morphology,pore number,pore volume,pore size,plane porosity,and volume porosity of salt rock were analyzed.The failure path of salt rock specimens under cyclic loading was analyzed using the distribution law of plane porosity.The damage variable of salt rock under cyclic loading was defined on basis of the variation of volume porosity with cycle number.In order to describe the fatigue deformation behavior of salt rock under cyclic loading,the nonlinear Burgers damage constitutive model was further established.The results show that the model established can better reflect the whole development process of fatigue deformation of salt rock under cyclic loading.展开更多
The geometry of joints has a significant influence on the mechanical properties of rocks.To simplify the curved joint shapes in rocks,the joint shape is usually treated as straight lines or planes in most laboratory e...The geometry of joints has a significant influence on the mechanical properties of rocks.To simplify the curved joint shapes in rocks,the joint shape is usually treated as straight lines or planes in most laboratory experiments and numerical simulations.In this study,the computerized tomography (CT) scanning and photogrammetry were employed to obtain the internal and surface joint structures of a limestone sample,respectively.To describe the joint geometry,the edge detection algorithms and a three-dimensional (3D) matrix mapping method were applied to reconstruct CT-based and photogrammetry-based jointed rock models.For comparison tests,the numerical uniaxial compression tests were conducted on an intact rock sample and a sample with a joint simplified to a plane using the parallel computing method.The results indicate that the mechanical characteristics and failure process of jointed rocks are significantly affected by the geometry of joints.The presence of joints reduces the uniaxial compressive strength (UCS),elastic modulus,and released acoustic emission (AE) energy of rocks by 37%–67%,21%–24%,and 52%–90%,respectively.Compared to the simplified joint sample,the proposed photogrammetry-based numerical model makes the most of the limited geometry information of joints.The UCS,accumulative released AE energy,and elastic modulus of the photogrammetry-based sample were found to be very close to those of the CT-based sample.The UCS value of the simplified joint sample (i.e.38.5 MPa) is much lower than that of the CT-based sample (i.e.72.3 MPa).Additionally,the accumulative released AE energy observed in the simplified joint sample is 3.899 times lower than that observed in the CT-based sample.CT scanning provides a reliable means to visualize the joints in rocks,which can be used to verify the reliability of photogrammetry techniques.The application of the photogrammetry-based sample enables detailed analysis for estimating the mechanical properties of jointed rocks.展开更多
Hemangioblastomas are benign vascular tumors of the brain. These are rare tumors, usually located in the cerebellum and most often affecting young adults. The aim was to study the value of CT in the management of hema...Hemangioblastomas are benign vascular tumors of the brain. These are rare tumors, usually located in the cerebellum and most often affecting young adults. The aim was to study the value of CT in the management of hemangioblastoma through observation. We report the case of a 38-year-old patient referred to the radiology and Medical Imaging Department of the Marie Curie Medical Clinic in Bamako, Mali, for an orbito-cerebral CT scan in a context of bilateral eyelid edema. The examination was performed using multi-slice computed tomography (16 slices) with reconstruction in the 3 planes of space without and with the injection of an iodinated contrast agent. The CT scan was crucial in making the diagnosis of hemangioblastoma incidentally, which allowed for adequate management. The patient was operated on, and the radiological outcome was favorable, without significant cystic formation, after postoperative control and clinical signs were resolved. CT can be an interesting alternative in countries like ours despite MRI being the examination of choice in hemangioblastomas.展开更多
Objective: To compare and analyze the image quality and radiation dose of three scanning modes of dual-source CT coronary artery retrospectively, and to discuss the application value of TurboFlash coarse pitch scannin...Objective: To compare and analyze the image quality and radiation dose of three scanning modes of dual-source CT coronary artery retrospectively, and to discuss the application value of TurboFlash coarse pitch scanning mode. Methods: The imaging data of 100 patients who underwent CT coronary angiography (CCTA) using Siemens force CT retrospective gated triggering spiral scan (RES-SPIRAL), adaptive prospective gated triggering sequence scan (SEQ) and prospective coarse pitch scan (TurboFlash) retrospectively was collected. The image quality was evaluated by objective and subjective methods. The effective radiation dose of patients was compared and analyzed, and the indications of the three scanning modes were analyzed. The application value of dual-source CT TurboFlash coarse pitch scanning in coronary artery imaging was evaluated. Results: The results showed that the left main coronary artery, the right coronary artery and their tertiary branches could be clearly displayed in the three groups of images: the left anterior descending branch, the left circumflex branch, and their three-level branches. There was no statistical difference in subjective image quality among the three groups of pictures (P > 0.05). There was no statistical difference in objective evaluation indexes, such as CT value, SNR, CNR and Noise among the three groups (P > 0.05). The patient radiation dose results showed that the effective radiation dose ED of RES-SPIRA scan was (9.22 ± 1.33) mSv. The dose of SEQ was (2.88 ± 2.47) mSv, and the dose of TurboFlash was (0.51 ± 0.16) mSv. There was significant difference in comparison of the three groups (P 0.05). RES-spiral scanning had the highest radiation dose and TurboFlash coarse pitch scanning (TurboFlash) had the lowest radiation dose. Conclusion: TurboFlash coarse pitch scanning is low in dosage, fast in speed and wide in adaptability. It is especially suitable for the elderly, children, coma and other patients who cannot cooperate with breath-holding examination, as well as for the screening and examination of coronary artery diseases in asymptomatic population. Undoubtedly, it is a worthy method of heart coronary artery examination.展开更多
基金supported by the National Key Research and Development Program of China (Grant No.2018YFA0702400)the National Natural Science Foundation of China (Grant No.52174050)+1 种基金the Natural Science Foundation of Shandong Province (Grant No.ZR2020ME088)the National Natural Science Foundation of Qingdao (Grant No.23-2-1-227-zyyd-jch)。
文摘Hot water flooding is an effective way to develop heavy oil reservoirs.However,local channeling channels may form,possibly leading to a low thermal utilization efficiency and high water cut in the reservoir.The pore structure heterogeneity is an important factor in forming these channels.This study proposes a method that mixes quartz sand with different particle sizes to prepare weakly heterogeneous and strongly heterogeneous models through which hot water flooding experiments are conducted.During the experiments,computer tomography(CT)scanning identifies the pore structure and micro remaining oil saturation distribution to analyze the influence of the pore structure heterogeneity on the channeling channels.The oil saturation reduction and average pore size are divided into three levels to quantitatively describe the relationship between the channeling channel distribution and pore structure heterogeneity.The zone where oil saturation reduction exceeds 20%is defined as a channeling channel.The scanning area is divided into 180 equally sized zones based on the CT scanning images,and threedimensional(3D)distributions of the channeling channels are developed.Four micro remaining oil distribution patterns are proposed,and the morphology characteristics of micro remaining oil inside and outside the channeling channels are analyzed.The results show that hot water flooding is more balanced in the weakly heterogeneous model,and the oil saturation decreases by more than 20%in most zones without narrow channeling channels forming.In the strongly heterogeneous model,hot water flooding is unbalanced,and three narrow channeling channels of different lengths form.In the weakly heterogeneous model,the oil saturation reduction is greater in zones with larger pores.The distribution range of the average pore size is larger in the strongly heterogeneous model.The network remaining oil inside the channeling channels is less than outside the channeling channels,and the hot water converts the network remaining oil into cluster,film,and droplet remaining oil.
基金supported by the National Natural Science Foundation of China(No.52178354).
文摘To investigate the macroscopic fatigue properties and the mesoscopic pore evolution characteristics of salt rock under cyclic loading,fatigue tests under different upper-limit stresses were carried out on salt rock,and the mesoscopic pore structures of salt rock before and after fatigue tests and under different cycle numbers were measured using CT scanning instrument.Based on the test results,the effects of the cycle number and the upper-limit stress on the evolution of cracks,pore morphology,pore number,pore volume,pore size,plane porosity,and volume porosity of salt rock were analyzed.The failure path of salt rock specimens under cyclic loading was analyzed using the distribution law of plane porosity.The damage variable of salt rock under cyclic loading was defined on basis of the variation of volume porosity with cycle number.In order to describe the fatigue deformation behavior of salt rock under cyclic loading,the nonlinear Burgers damage constitutive model was further established.The results show that the model established can better reflect the whole development process of fatigue deformation of salt rock under cyclic loading.
基金supported by the National Natural Science Foundation of China(Grant Nos.42277150,41977219)Henan Provincial Science and Technology Research Project(Grant No.222102320271).
文摘The geometry of joints has a significant influence on the mechanical properties of rocks.To simplify the curved joint shapes in rocks,the joint shape is usually treated as straight lines or planes in most laboratory experiments and numerical simulations.In this study,the computerized tomography (CT) scanning and photogrammetry were employed to obtain the internal and surface joint structures of a limestone sample,respectively.To describe the joint geometry,the edge detection algorithms and a three-dimensional (3D) matrix mapping method were applied to reconstruct CT-based and photogrammetry-based jointed rock models.For comparison tests,the numerical uniaxial compression tests were conducted on an intact rock sample and a sample with a joint simplified to a plane using the parallel computing method.The results indicate that the mechanical characteristics and failure process of jointed rocks are significantly affected by the geometry of joints.The presence of joints reduces the uniaxial compressive strength (UCS),elastic modulus,and released acoustic emission (AE) energy of rocks by 37%–67%,21%–24%,and 52%–90%,respectively.Compared to the simplified joint sample,the proposed photogrammetry-based numerical model makes the most of the limited geometry information of joints.The UCS,accumulative released AE energy,and elastic modulus of the photogrammetry-based sample were found to be very close to those of the CT-based sample.The UCS value of the simplified joint sample (i.e.38.5 MPa) is much lower than that of the CT-based sample (i.e.72.3 MPa).Additionally,the accumulative released AE energy observed in the simplified joint sample is 3.899 times lower than that observed in the CT-based sample.CT scanning provides a reliable means to visualize the joints in rocks,which can be used to verify the reliability of photogrammetry techniques.The application of the photogrammetry-based sample enables detailed analysis for estimating the mechanical properties of jointed rocks.
文摘Hemangioblastomas are benign vascular tumors of the brain. These are rare tumors, usually located in the cerebellum and most often affecting young adults. The aim was to study the value of CT in the management of hemangioblastoma through observation. We report the case of a 38-year-old patient referred to the radiology and Medical Imaging Department of the Marie Curie Medical Clinic in Bamako, Mali, for an orbito-cerebral CT scan in a context of bilateral eyelid edema. The examination was performed using multi-slice computed tomography (16 slices) with reconstruction in the 3 planes of space without and with the injection of an iodinated contrast agent. The CT scan was crucial in making the diagnosis of hemangioblastoma incidentally, which allowed for adequate management. The patient was operated on, and the radiological outcome was favorable, without significant cystic formation, after postoperative control and clinical signs were resolved. CT can be an interesting alternative in countries like ours despite MRI being the examination of choice in hemangioblastomas.
文摘Objective: To compare and analyze the image quality and radiation dose of three scanning modes of dual-source CT coronary artery retrospectively, and to discuss the application value of TurboFlash coarse pitch scanning mode. Methods: The imaging data of 100 patients who underwent CT coronary angiography (CCTA) using Siemens force CT retrospective gated triggering spiral scan (RES-SPIRAL), adaptive prospective gated triggering sequence scan (SEQ) and prospective coarse pitch scan (TurboFlash) retrospectively was collected. The image quality was evaluated by objective and subjective methods. The effective radiation dose of patients was compared and analyzed, and the indications of the three scanning modes were analyzed. The application value of dual-source CT TurboFlash coarse pitch scanning in coronary artery imaging was evaluated. Results: The results showed that the left main coronary artery, the right coronary artery and their tertiary branches could be clearly displayed in the three groups of images: the left anterior descending branch, the left circumflex branch, and their three-level branches. There was no statistical difference in subjective image quality among the three groups of pictures (P > 0.05). There was no statistical difference in objective evaluation indexes, such as CT value, SNR, CNR and Noise among the three groups (P > 0.05). The patient radiation dose results showed that the effective radiation dose ED of RES-SPIRA scan was (9.22 ± 1.33) mSv. The dose of SEQ was (2.88 ± 2.47) mSv, and the dose of TurboFlash was (0.51 ± 0.16) mSv. There was significant difference in comparison of the three groups (P 0.05). RES-spiral scanning had the highest radiation dose and TurboFlash coarse pitch scanning (TurboFlash) had the lowest radiation dose. Conclusion: TurboFlash coarse pitch scanning is low in dosage, fast in speed and wide in adaptability. It is especially suitable for the elderly, children, coma and other patients who cannot cooperate with breath-holding examination, as well as for the screening and examination of coronary artery diseases in asymptomatic population. Undoubtedly, it is a worthy method of heart coronary artery examination.