Inosine monophosphate(IMP),as a critical umami substance,is one of the most important indicators for evaluating the quality of meat products.Here,a sensitive electrochemiluminescence(ECL)biosensor based on graphdiyne(...Inosine monophosphate(IMP),as a critical umami substance,is one of the most important indicators for evaluating the quality of meat products.Here,a sensitive electrochemiluminescence(ECL)biosensor based on graphdiyne(GDY)/AuNPs/luminol nanocomposites was constructed to detect IMP.The GDY/AuNPs/luminol nanocomposites were synthesized by using simple one-pot method.GDY utilized its 2D framework to disperse and fix gold nanoparticles,which inhibited the agglomeration of gold nanoparticles and greatly improved its stability and catalytic properties.Importantly,GDY/AuNPs/luminol nanocomposites showed excellent catalytic ability and superior ECL activity towards luminol-H_(2)O_(2) systems due to the synergistic effect of GDY and AuNPs.Under optimal conditions,the prepared biosensor exhibited a wide linear range from 0.01 g/L to 20 g/L,a satisfactory limit detection of 0.0013 g/L,as well as an excellent specificity.Moreover,we carried out the precise analysis of IMP in actual meat samples with acceptable results compared to the liquid chromatography.We believe that this work could offer an efficient ECL platform for accurate and reliable report of IMP levels,which is significant for maintaining food quality and safety.展开更多
A novel method for the determination of two quinolone drugs norfloxacin (NOR) and levofloxacin (LVX) was described by capillary electrophoresis with electrochemiluminescence detection. The good relationship (r ≥...A novel method for the determination of two quinolone drugs norfloxacin (NOR) and levofloxacin (LVX) was described by capillary electrophoresis with electrochemiluminescence detection. The good relationship (r ≥ 0.9991) between peak area and concentration of analytes was established over two orders of magnitude. The limits of detection (LOD, S/N = 3) in standard solution are 4.8 × 10^-7 mol/L for NOR and 6.4 × 10^-7 mol/L for LVX, respectively. The limits of quantitation (LOQ, S/N = 10) in real human urine samples are 1.2 × 10^-6 mol/L for NOR and 1.4 × 10^-6 mol/L for LVX, respectively. The present method was successfully applied to the determination of NOR and LVX in human urine and the studv of oharmacokinetics of NOR.展开更多
The solid-state ECL behavior of a water-insoluble bis-cyclometalated (pq)2Ir(N-phMA) complex is presented, in which pq is a 2-phenylquinoline anion and N-phMA is N-phenyl methacrylamide, a monoanionic bidentate li...The solid-state ECL behavior of a water-insoluble bis-cyclometalated (pq)2Ir(N-phMA) complex is presented, in which pq is a 2-phenylquinoline anion and N-phMA is N-phenyl methacrylamide, a monoanionic bidentate ligand. The MWNTs/(pq)2Ir(N-phMA) film, MWNTs/Ru(bpy)3^2+ film and (pq)2Ir(N-phMA) directly modified glassy carbon electrode were fabricated; only the MWNTs/(pq)2Ir(N-phMA) film can produce steady ECL in the presence of tri-n-propylamine as a coreactant.展开更多
Eu(Ⅲ) complexes with chosen Keggin polyoxomatalates, POM, containing organic counter cations (tetrabutylarnmonium, tetrabutylphosphonium, triphenylethylphosphonium), were synthesized, and their photophysical prop...Eu(Ⅲ) complexes with chosen Keggin polyoxomatalates, POM, containing organic counter cations (tetrabutylarnmonium, tetrabutylphosphonium, triphenylethylphosphonium), were synthesized, and their photophysical properties were studied. The synthesized complexes had the general formula of XnH5-n[EuSiW11O39], formulated based on the results of elemental and thermogravimetric analysis and FTIR spectroscopy. The photophysical properties of the obtained compounds were investigated using photoluminescence and electrochemiluminescence, ECL, methods in solutions and solids. The most intense luminescence of Eu(Ⅲ) was observed for the complexes with tetrabutylarnmonium cations. After the addition of phenanthroline to the XnH5-n[EuSiW11O39] solutions, a large increase in the Eu(Ⅲ) luminescence intensity and a lengthening of its luminescence lifetime were observed as a result of the formation of ternary complexes. Attempts to apply ECL as a method of light emission by generating species capable of forming excited states in Ln/POMs, i.e., Tb(Ⅲ) and Eu(Ⅲ) in the Na9EuW10O36 and Na9TbW10O36 complexes, were made. The influence of the POM complexes on the ECL was also tested using the Tb/EDDHA (EDDA=ethylenediamine di(o-hydroxyphenylacetic acid)) complex, which is effective in generating ECL.展开更多
A capillary electrophoresis (CE) coupled with end-column electrochemiluminescence (ECL) detection method for the analysis of tramadol (TMD) has been investigated. ECL detection was working electrode biased at 1.2 V in...A capillary electrophoresis (CE) coupled with end-column electrochemiluminescence (ECL) detection method for the analysis of tramadol (TMD) has been investigated. ECL detection was working electrode biased at 1.2 V in a 20mmol·L-1 sodium phosphate buffer (pH = 8.0) containing 5 mmol·L-1 Ru (where bpy = 2,2’-bipyridyl). Linear correlation (r ≥ 0.997) between ECL intensity and drug concentration was obtained in the range 3 × 10-4 - 6 × 10-6 mol·L-1. The limits of detection (LODs) for tramadol in water was 3.012 × 10-8 mol·L-1(S/N = 3). The relative standard deviation values on peak size (10-5 mol·L-1 level) and migration time for the tramadol were 4.58% and 1.39% (n = 10), respectively. Applicability of the CE-ECL method to the analysis of human serum spiked with tramadol was展开更多
Investigation of ultraweak emissions in the processes of chemiluminescence, CL, and electrochemiluminesce, ECL, requires special techniques of their recording and spectral analysis. From among the hitherto proposed me...Investigation of ultraweak emissions in the processes of chemiluminescence, CL, and electrochemiluminesce, ECL, requires special techniques of their recording and spectral analysis. From among the hitherto proposed methods of detection of the emission spectra of these processes, that of the cut-off filter was most sensitive. The usefulness of this method in interpretation of the CL and ECL systems of the quantum yields in the range 1×10^-9-1×10^-11 containing ions and complexes of Eu(Ⅲ), Tb(Ⅲ) and Dy0ID was shown. Exceptional character of the emission bands of lanthanide ions, being a result of the f-f electron transitions and in particular their low FWHM, permitted the appli- cation of the cut-off filter method to their analysis. The results obtained for CL and ECL on the basis of analysis of ultraweak emission proved to be successful in analytical applications. The systems containing Eu(Ⅲ) ions hydrated or complexed with organic ligands enabled inferring changes in the coordination sphere of the ions.展开更多
A highly sensitive telomerase detection method that combines telomeric repeat amplification protocol (TRAP) and magnetic beads based electrochemiluminescence (ECL) assay has been developed. Briefly, telomerase rec...A highly sensitive telomerase detection method that combines telomeric repeat amplification protocol (TRAP) and magnetic beads based electrochemiluminescence (ECL) assay has been developed. Briefly, telomerase recognizes biotinylated telomerase synthesis primer (B-TS) and synthesizes extension products, which then serve as the templates for PCR amplification using B-TS as the forward primer and tris-(2′2′-bipyridyl) ruthenium (TBR) labeled ACX (TBR-ACX) as the reversed primer. The amplified product is captured on streptavidin-coated paramagnetic beads and detected by ECL. Telomerase positive HeLa cells were used to validate the feasibility of the method. The experimental results showed down to 10 cancer cells can be detected easily. The method is a useful tool for telomerase activity analysis due to its sensitivity, rapidity, safety, high throughput, and low cost. It can be used for screening a large amount of clinical samples.展开更多
The unique cathodic electrochemiluminescence(ECL) emission of Ru(bpy)3^2+(bpy=2,2′-bipyridine) was observed via Nation film at Au electrode[Au/Nafion/Ru(bpy)3^2+] at about 0.20 V(vs. Ag/AgCl) and applied ...The unique cathodic electrochemiluminescence(ECL) emission of Ru(bpy)3^2+(bpy=2,2′-bipyridine) was observed via Nation film at Au electrode[Au/Nafion/Ru(bpy)3^2+] at about 0.20 V(vs. Ag/AgCl) and applied to the determination of several amino acids without prior derivatization with high sensitivity. The cathodic electrochemiluminescence(ECL) exhibits the detection limits and linear ranges of several amino acids comparable to or better than those of capillary electrophoresis with conventional ECL detection method(at 1.10-1.20 V vs. Ag/AgCl) based on precolumn derivatization. The results suggest that the cathodic ECL is promising for the detection of amino acids in bioanalysis.展开更多
An on-line Ag/Al galvanic cell is investigated and employed to generate electrochemiluminescence (ECL). The potential of the galvanic cell could be adjusted by varying the components of flow reagent. The cell perfor...An on-line Ag/Al galvanic cell is investigated and employed to generate electrochemiluminescence (ECL). The potential of the galvanic cell could be adjusted by varying the components of flow reagent. The cell performed perfect capability of supplying a stable potential for ECL generation. Based on the weak ECL of calcein blue could be greatly sensitized by the presence of calcium in alkaline solution, calcium contents in milk samples and in cabbage were assayed and the results were compared with those from ICP-AES method.展开更多
An improved electrochemiluminescence polymerase chain reaction (ECL-PCR) method was developed and applied to detect Fusarium wilt. Briefly, the internal transcribed spacer (ITS) sequence of Fusarium oxysporumf, sp...An improved electrochemiluminescence polymerase chain reaction (ECL-PCR) method was developed and applied to detect Fusarium wilt. Briefly, the internal transcribed spacer (ITS) sequence of Fusarium oxysporumf, sp Cubense (FOC) was amplified by PCR. Two universal fragments, which were complimentary to Ru(bpy)3^2+ (TBR) labeled probe and Biotin labeled probe, respectively, were connected to the tail of primers so that all the PCR products got universal sequences. Then biotin labeled probes and TBR labeled probes were hybridized with the PCR products at the same time. Through the specific interaction between biotin and streptavidin, the PCR products were captured by streptavidin coated magnetic bead and then detected by ECL assay. The experiment results showed that the healthy banana samples and infected ones can be discriminated by this ECL-PCR method. This improved ECL-PCR approach is useful in Fusarium wilt detection due to its high sensitivity, simplicity and stability.展开更多
The antidepressant trimipramine(Tri) enantiomers were successfully separated by capillary electrophoresis(CE) coupled with electrochemiluminescence(ECL) detection in aqueous-organic media. A dual cyclodextrin(C...The antidepressant trimipramine(Tri) enantiomers were successfully separated by capillary electrophoresis(CE) coupled with electrochemiluminescence(ECL) detection in aqueous-organic media. A dual cyclodextrin(CD) system combining β-CD and hydroxypropyl-β-cyclodextrin(HP-β-CD) was used as chiral selector. Acetonitrile(ACN) was added to the running buffer to improve the separation efficiency, detection sensitivity and repeatability. The method was also successfully applied to the chiral separation of Tri in spiked human urine sample.展开更多
The electrochemi luminescence <ecl> of a new reagent 6-<2-hydroxy-4-diethylaminophenylazo>-2, 3-dihydro-1, 4-phthatazine-1, 4-dione <HDEA> in basic aqueous solution was studied. Trace amount of silve...The electrochemi luminescence <ecl> of a new reagent 6-<2-hydroxy-4-diethylaminophenylazo>-2, 3-dihydro-1, 4-phthatazine-1, 4-dione <HDEA> in basic aqueous solution was studied. Trace amount of silver showed significant effect on the efficiency of light emission of HDEA during a positive trigonometrical wave pulse was exerted on the electrodes In the present paper, the ecl spectra of HDEA have been measured. λ_(max) is 410 nm. The reaction of HDEA chemiluminescence and the circular voltammetry, ultraviolet-visible spectrometry for the system have been investigated. The possible mechanism of the ecl of HDEA-KCL-KOH-Ag(I) system has been proposed.展开更多
A new approach combined the specificity of allele-specific amplification (ASA) with the sensitivity of electrochemiluminescence (ECL) assay for single nucleotide polymorphism (SNP) analysis was proposed. Briefly...A new approach combined the specificity of allele-specific amplification (ASA) with the sensitivity of electrochemiluminescence (ECL) assay for single nucleotide polymorphism (SNP) analysis was proposed. Briefly, target gene was amplified by a biotin-labeled allele-specific forward primer and a Ru(bpy)3 ^2+(TBR)-labeled universal reverse primer. Then, the amplicon was captured onto streptavidin-coated paramagnetic beads through biotin label, and detected by measuring the ECL signal of TBR label. Different genotypes were distinguished according to the ECL values of the amplicons by different genotypic primers. K-ras oncogene was used as a target to validate the feasibility of the method. The experiment results show that the different genotypes can be clearly distinguished by ASA-ECL assay. The method is useful in SNP analysis due to its sensitivity,safety, and simplicity.展开更多
Ru(bpy)3^2+ electrochemiluminescence (ECL) was applied to determination of rutin. ECL intensity of Ru(bpy)3^2+ could be enhanced in the presence of rufin in basic solution on platinum electrode. At pH 9.9, lig...Ru(bpy)3^2+ electrochemiluminescence (ECL) was applied to determination of rutin. ECL intensity of Ru(bpy)3^2+ could be enhanced in the presence of rufin in basic solution on platinum electrode. At pH 9.9, light emission intensity was found to be linear with rutin in the range of 1-50μmol/L.展开更多
Three kinds of platinum electrodes with different geometry were designed. The relation of the electrochemiluminescence (ECL) intensity with the geometry of these electrodes has been investigated. The optical charact...Three kinds of platinum electrodes with different geometry were designed. The relation of the electrochemiluminescence (ECL) intensity with the geometry of these electrodes has been investigated. The optical character of these electrodes was directly studied by observation of ECL image and measurement of the ECL intensity. The results showed that the ECL not only concentrated on the edge of the electrode but also concentrated on the edge of holes, which contain in the electrode. The ECL intensity from Ru(bpy)3Cl2·6H2O on round electrode was about half of that on four-hole round disk electrode for a same concentration of Ru(bpy)3Cl2·6H2O, so the detection limit was improved to 10-18 mol/L Ru(bpy)3Cl2·6H2O on four-hole round disk electrode, three times higher than that on round disk electrode.展开更多
The electrochemiluminescence (ECL) of a new reagent 6- (2-hydroxy- 4 diethy laminophenylazo)-2,3-dihydro-1 ,4-phthalazine-1,4-dione (HDEA) in a basic aqueous so lution was studied by using the apparatus designed by ou...The electrochemiluminescence (ECL) of a new reagent 6- (2-hydroxy- 4 diethy laminophenylazo)-2,3-dihydro-1 ,4-phthalazine-1,4-dione (HDEA) in a basic aqueous so lution was studied by using the apparatus designed by ourselves. Trace amounts of silver ( Ⅰ ) shows a significant effect on the efficiency of light emission of HDEA during a positive trigonometrical wave pulse was exerted on the solution. The linear relationship between the light intensity and the concentration of silver( Ⅰ ) occurs in the range of 5. 0×10-8 to 3. 0×10-8 mol/L Ag(Ⅰ ) in a medium of KOH-KCl-HDEA (pH= 12. 8). The detection limit of the method is 2. 0×10-8 mol/LAg( Ⅰ ), and the r. s. d. for 1.0×10-7 mo)/L Ag ( Ⅰ ) is 5%. Of 21 metal ions concerned, only nickel( Ⅱ ), cerium( Ⅳ ) and cobalt( Ⅱ ) interfere the silver detection seriously; Ⅰ and Br also have some interference.展开更多
Objective To investigate the electrochemiluminescence (ECL) behavior of cloperastine hydrochloride. Methods ECL intensity of tris (2,2′-bipyridyl) rutheniumo(Ⅱ) was enhanced, the method for the determination of clop...Objective To investigate the electrochemiluminescence (ECL) behavior of cloperastine hydrochloride. Methods ECL intensity of tris (2,2′-bipyridyl) rutheniumo(Ⅱ) was enhanced, the method for the determination of cloperastine hydrochloride was established using capillary electrophoresis (CE) coupled with electrochemilumolinescence (ECL) detection. Results Under the optimum conditions, ECL intensity varied linearly with cloperastine hydrochloride concentration from 7.0×10-6g/mL to 1.0×10-4g/mL. The detection limit (S/N=3) was 8.05×10-7g/mL. The relative standard deviation of the ECL intensity and the migration time for 11 consecutive injections of 1.0×10-5g/mL cloperastine hydrochloride was 2.9% and 1.5%, respectively. This method was successfully applied to cloperastine hydrochloride tablet determination. Conclusion The method has been established, validated and applied for determination of cloperastine hydrochloride.展开更多
[ Objective] This study aimed to establish an electrochemiluminescence method for determining the trace molybdenum in plant seeds. [ Method ] The equipment used in this study consisted of an electrogenerated reagent s...[ Objective] This study aimed to establish an electrochemiluminescence method for determining the trace molybdenum in plant seeds. [ Method ] The equipment used in this study consisted of an electrogenerated reagent system and a flow-injection chemiluminescence detection system. The optimal electric poten- tial, reagent acidity, flow rate of sample solution, as well as the concentration and alkalinity of luminal were screened to measure the trace molybdenum in plant seeds. [ Result I The unstable molybdenum (III) was on-line electrogenerated from molybdenum (VI) via controlled potential electrolysis technique using a home- made flow-through carbon electrolytic cell at the potential of -0.60 V (vs Ag/AgC1). The method allowed the determination of 5.0 × 10-10 _ 5.0 ×10-7 g/ml mo- lybdenum with a detection limit of 5 × 10 u g/ml molybdenum (VI). The relative standard deviation was 2.6% for the 1.0 × 10 -9 g/ml molybdenum solution in 11 measurements. [ Conclusion] Compared with the previous methods, this electrochemilum^nescence method not only improved the selectivity of the determina- tion, but also avoided the use of toxic reagent mercury.展开更多
The anodic oxygen evolution reaction is a well-acknowledged side reaction in traditional aqueous electrochemiluminescence(ECL) systems due to the generation and surface aggregation of oxygen at the electrode, which de...The anodic oxygen evolution reaction is a well-acknowledged side reaction in traditional aqueous electrochemiluminescence(ECL) systems due to the generation and surface aggregation of oxygen at the electrode, which detrimentally impacts the stability and efficiency of ECL emission. However, the effect of reactive oxygen species generated during water oxidation on ECL luminophores has been largely overlooked. Taking the typical luminol emitter as an example, herein, we employed NiIr single-atom alloy aerogels possessing efficient water oxidation activity as a prototype co-reaction accelerator to elucidate the relationship between ECL behavior and water oxidation reaction kinetics for the first time. By regulating the concentration of hydroxide ions in the electrolyte, the electrochemical oxidation processes of both luminol and water are finely tuned. When the concentration of hydroxide ions in electrolyte is low,the kinetics of water oxidation is attenuated, which limits the generation of oxygen, effectively mitigates the influence of oxygen accumulation on the ECL strength, and offers a novel perspective for harnessing side reactions in ECL systems. Finally, a sensitive and stable sensor for antioxidant detection was constructed and applied to the practical sample detection.展开更多
基金supported by The National Natural Science Foundation of China(31972198,31622042)The National Key R&D Program of China(2016YFD0400803,2016YFD0401501).
文摘Inosine monophosphate(IMP),as a critical umami substance,is one of the most important indicators for evaluating the quality of meat products.Here,a sensitive electrochemiluminescence(ECL)biosensor based on graphdiyne(GDY)/AuNPs/luminol nanocomposites was constructed to detect IMP.The GDY/AuNPs/luminol nanocomposites were synthesized by using simple one-pot method.GDY utilized its 2D framework to disperse and fix gold nanoparticles,which inhibited the agglomeration of gold nanoparticles and greatly improved its stability and catalytic properties.Importantly,GDY/AuNPs/luminol nanocomposites showed excellent catalytic ability and superior ECL activity towards luminol-H_(2)O_(2) systems due to the synergistic effect of GDY and AuNPs.Under optimal conditions,the prepared biosensor exhibited a wide linear range from 0.01 g/L to 20 g/L,a satisfactory limit detection of 0.0013 g/L,as well as an excellent specificity.Moreover,we carried out the precise analysis of IMP in actual meat samples with acceptable results compared to the liquid chromatography.We believe that this work could offer an efficient ECL platform for accurate and reliable report of IMP levels,which is significant for maintaining food quality and safety.
基金the National Natural Science Foundation of China(No.20575056)Henan Innovation Project for University Research Talents(No.2005126).
文摘A novel method for the determination of two quinolone drugs norfloxacin (NOR) and levofloxacin (LVX) was described by capillary electrophoresis with electrochemiluminescence detection. The good relationship (r ≥ 0.9991) between peak area and concentration of analytes was established over two orders of magnitude. The limits of detection (LOD, S/N = 3) in standard solution are 4.8 × 10^-7 mol/L for NOR and 6.4 × 10^-7 mol/L for LVX, respectively. The limits of quantitation (LOQ, S/N = 10) in real human urine samples are 1.2 × 10^-6 mol/L for NOR and 1.4 × 10^-6 mol/L for LVX, respectively. The present method was successfully applied to the determination of NOR and LVX in human urine and the studv of oharmacokinetics of NOR.
基金supported by the National Natural Science Foundation of China (No.20571033).
文摘The solid-state ECL behavior of a water-insoluble bis-cyclometalated (pq)2Ir(N-phMA) complex is presented, in which pq is a 2-phenylquinoline anion and N-phMA is N-phenyl methacrylamide, a monoanionic bidentate ligand. The MWNTs/(pq)2Ir(N-phMA) film, MWNTs/Ru(bpy)3^2+ film and (pq)2Ir(N-phMA) directly modified glassy carbon electrode were fabricated; only the MWNTs/(pq)2Ir(N-phMA) film can produce steady ECL in the presence of tri-n-propylamine as a coreactant.
文摘Eu(Ⅲ) complexes with chosen Keggin polyoxomatalates, POM, containing organic counter cations (tetrabutylarnmonium, tetrabutylphosphonium, triphenylethylphosphonium), were synthesized, and their photophysical properties were studied. The synthesized complexes had the general formula of XnH5-n[EuSiW11O39], formulated based on the results of elemental and thermogravimetric analysis and FTIR spectroscopy. The photophysical properties of the obtained compounds were investigated using photoluminescence and electrochemiluminescence, ECL, methods in solutions and solids. The most intense luminescence of Eu(Ⅲ) was observed for the complexes with tetrabutylarnmonium cations. After the addition of phenanthroline to the XnH5-n[EuSiW11O39] solutions, a large increase in the Eu(Ⅲ) luminescence intensity and a lengthening of its luminescence lifetime were observed as a result of the formation of ternary complexes. Attempts to apply ECL as a method of light emission by generating species capable of forming excited states in Ln/POMs, i.e., Tb(Ⅲ) and Eu(Ⅲ) in the Na9EuW10O36 and Na9TbW10O36 complexes, were made. The influence of the POM complexes on the ECL was also tested using the Tb/EDDHA (EDDA=ethylenediamine di(o-hydroxyphenylacetic acid)) complex, which is effective in generating ECL.
文摘A capillary electrophoresis (CE) coupled with end-column electrochemiluminescence (ECL) detection method for the analysis of tramadol (TMD) has been investigated. ECL detection was working electrode biased at 1.2 V in a 20mmol·L-1 sodium phosphate buffer (pH = 8.0) containing 5 mmol·L-1 Ru (where bpy = 2,2’-bipyridyl). Linear correlation (r ≥ 0.997) between ECL intensity and drug concentration was obtained in the range 3 × 10-4 - 6 × 10-6 mol·L-1. The limits of detection (LODs) for tramadol in water was 3.012 × 10-8 mol·L-1(S/N = 3). The relative standard deviation values on peak size (10-5 mol·L-1 level) and migration time for the tramadol were 4.58% and 1.39% (n = 10), respectively. Applicability of the CE-ECL method to the analysis of human serum spiked with tramadol was
基金support from the Polish Ministry of Science and Higher EducationGrant N N204 028236
文摘Investigation of ultraweak emissions in the processes of chemiluminescence, CL, and electrochemiluminesce, ECL, requires special techniques of their recording and spectral analysis. From among the hitherto proposed methods of detection of the emission spectra of these processes, that of the cut-off filter was most sensitive. The usefulness of this method in interpretation of the CL and ECL systems of the quantum yields in the range 1×10^-9-1×10^-11 containing ions and complexes of Eu(Ⅲ), Tb(Ⅲ) and Dy0ID was shown. Exceptional character of the emission bands of lanthanide ions, being a result of the f-f electron transitions and in particular their low FWHM, permitted the appli- cation of the cut-off filter method to their analysis. The results obtained for CL and ECL on the basis of analysis of ultraweak emission proved to be successful in analytical applications. The systems containing Eu(Ⅲ) ions hydrated or complexed with organic ligands enabled inferring changes in the coordination sphere of the ions.
基金This research is supported by the National Natural Science Foundation of China (No.30600128 30700155);the National High Technology Research and Development Program of China (863 Program) (No.2007AA10Z204);the Natural Science Foundation of Guangdong Province (No.7005825).
文摘A highly sensitive telomerase detection method that combines telomeric repeat amplification protocol (TRAP) and magnetic beads based electrochemiluminescence (ECL) assay has been developed. Briefly, telomerase recognizes biotinylated telomerase synthesis primer (B-TS) and synthesizes extension products, which then serve as the templates for PCR amplification using B-TS as the forward primer and tris-(2′2′-bipyridyl) ruthenium (TBR) labeled ACX (TBR-ACX) as the reversed primer. The amplified product is captured on streptavidin-coated paramagnetic beads and detected by ECL. Telomerase positive HeLa cells were used to validate the feasibility of the method. The experimental results showed down to 10 cancer cells can be detected easily. The method is a useful tool for telomerase activity analysis due to its sensitivity, rapidity, safety, high throughput, and low cost. It can be used for screening a large amount of clinical samples.
基金Supported by the National Natural Science Foundation of China(No.20605020)the Distinguished Young Scholars of Jilin Province, China(No.20060112)the Fundamental Research Funds for the Central Universities(No.DL09BB25)
文摘The unique cathodic electrochemiluminescence(ECL) emission of Ru(bpy)3^2+(bpy=2,2′-bipyridine) was observed via Nation film at Au electrode[Au/Nafion/Ru(bpy)3^2+] at about 0.20 V(vs. Ag/AgCl) and applied to the determination of several amino acids without prior derivatization with high sensitivity. The cathodic electrochemiluminescence(ECL) exhibits the detection limits and linear ranges of several amino acids comparable to or better than those of capillary electrophoresis with conventional ECL detection method(at 1.10-1.20 V vs. Ag/AgCl) based on precolumn derivatization. The results suggest that the cathodic ECL is promising for the detection of amino acids in bioanalysis.
基金This work was supportod by the National Natural Science Foundation of China(No.20175039).
文摘An on-line Ag/Al galvanic cell is investigated and employed to generate electrochemiluminescence (ECL). The potential of the galvanic cell could be adjusted by varying the components of flow reagent. The cell performed perfect capability of supplying a stable potential for ECL generation. Based on the weak ECL of calcein blue could be greatly sensitized by the presence of calcium in alkaline solution, calcium contents in milk samples and in cabbage were assayed and the results were compared with those from ICP-AES method.
基金the National Natural Science Foundation of China(No.3060012830470494)the Natural Science Foundation of Guangdong Province(No.70058257117865).
文摘An improved electrochemiluminescence polymerase chain reaction (ECL-PCR) method was developed and applied to detect Fusarium wilt. Briefly, the internal transcribed spacer (ITS) sequence of Fusarium oxysporumf, sp Cubense (FOC) was amplified by PCR. Two universal fragments, which were complimentary to Ru(bpy)3^2+ (TBR) labeled probe and Biotin labeled probe, respectively, were connected to the tail of primers so that all the PCR products got universal sequences. Then biotin labeled probes and TBR labeled probes were hybridized with the PCR products at the same time. Through the specific interaction between biotin and streptavidin, the PCR products were captured by streptavidin coated magnetic bead and then detected by ECL assay. The experiment results showed that the healthy banana samples and infected ones can be discriminated by this ECL-PCR method. This improved ECL-PCR approach is useful in Fusarium wilt detection due to its high sensitivity, simplicity and stability.
基金Supported by the National Natural Science Foundation of China(No20875085)the Fund of Chinese Academy of Sciences(NoKJCX2-YW-H11)
文摘The antidepressant trimipramine(Tri) enantiomers were successfully separated by capillary electrophoresis(CE) coupled with electrochemiluminescence(ECL) detection in aqueous-organic media. A dual cyclodextrin(CD) system combining β-CD and hydroxypropyl-β-cyclodextrin(HP-β-CD) was used as chiral selector. Acetonitrile(ACN) was added to the running buffer to improve the separation efficiency, detection sensitivity and repeatability. The method was also successfully applied to the chiral separation of Tri in spiked human urine sample.
基金This work was supported by National Natural Science Foundation of China
文摘The electrochemi luminescence <ecl> of a new reagent 6-<2-hydroxy-4-diethylaminophenylazo>-2, 3-dihydro-1, 4-phthatazine-1, 4-dione <HDEA> in basic aqueous solution was studied. Trace amount of silver showed significant effect on the efficiency of light emission of HDEA during a positive trigonometrical wave pulse was exerted on the electrodes In the present paper, the ecl spectra of HDEA have been measured. λ_(max) is 410 nm. The reaction of HDEA chemiluminescence and the circular voltammetry, ultraviolet-visible spectrometry for the system have been investigated. The possible mechanism of the ecl of HDEA-KCL-KOH-Ag(I) system has been proposed.
基金the National Natural Science Foundation of China (Nos. 30600128, 30670507,30470494) the Natural Science Foundation of Guangdong Province (No. 015012).
文摘A new approach combined the specificity of allele-specific amplification (ASA) with the sensitivity of electrochemiluminescence (ECL) assay for single nucleotide polymorphism (SNP) analysis was proposed. Briefly, target gene was amplified by a biotin-labeled allele-specific forward primer and a Ru(bpy)3 ^2+(TBR)-labeled universal reverse primer. Then, the amplicon was captured onto streptavidin-coated paramagnetic beads through biotin label, and detected by measuring the ECL signal of TBR label. Different genotypes were distinguished according to the ECL values of the amplicons by different genotypic primers. K-ras oncogene was used as a target to validate the feasibility of the method. The experiment results show that the different genotypes can be clearly distinguished by ASA-ECL assay. The method is useful in SNP analysis due to its sensitivity,safety, and simplicity.
基金This work was supported by the National Natural Science Foundation of China (No. 20475004);Instrumental Analysis Fund of Peking University.
文摘Ru(bpy)3^2+ electrochemiluminescence (ECL) was applied to determination of rutin. ECL intensity of Ru(bpy)3^2+ could be enhanced in the presence of rufin in basic solution on platinum electrode. At pH 9.9, light emission intensity was found to be linear with rutin in the range of 1-50μmol/L.
文摘Three kinds of platinum electrodes with different geometry were designed. The relation of the electrochemiluminescence (ECL) intensity with the geometry of these electrodes has been investigated. The optical character of these electrodes was directly studied by observation of ECL image and measurement of the ECL intensity. The results showed that the ECL not only concentrated on the edge of the electrode but also concentrated on the edge of holes, which contain in the electrode. The ECL intensity from Ru(bpy)3Cl2·6H2O on round electrode was about half of that on four-hole round disk electrode for a same concentration of Ru(bpy)3Cl2·6H2O, so the detection limit was improved to 10-18 mol/L Ru(bpy)3Cl2·6H2O on four-hole round disk electrode, three times higher than that on round disk electrode.
文摘The electrochemiluminescence (ECL) of a new reagent 6- (2-hydroxy- 4 diethy laminophenylazo)-2,3-dihydro-1 ,4-phthalazine-1,4-dione (HDEA) in a basic aqueous so lution was studied by using the apparatus designed by ourselves. Trace amounts of silver ( Ⅰ ) shows a significant effect on the efficiency of light emission of HDEA during a positive trigonometrical wave pulse was exerted on the solution. The linear relationship between the light intensity and the concentration of silver( Ⅰ ) occurs in the range of 5. 0×10-8 to 3. 0×10-8 mol/L Ag(Ⅰ ) in a medium of KOH-KCl-HDEA (pH= 12. 8). The detection limit of the method is 2. 0×10-8 mol/LAg( Ⅰ ), and the r. s. d. for 1.0×10-7 mo)/L Ag ( Ⅰ ) is 5%. Of 21 metal ions concerned, only nickel( Ⅱ ), cerium( Ⅳ ) and cobalt( Ⅱ ) interfere the silver detection seriously; Ⅰ and Br also have some interference.
文摘Objective To investigate the electrochemiluminescence (ECL) behavior of cloperastine hydrochloride. Methods ECL intensity of tris (2,2′-bipyridyl) rutheniumo(Ⅱ) was enhanced, the method for the determination of cloperastine hydrochloride was established using capillary electrophoresis (CE) coupled with electrochemilumolinescence (ECL) detection. Results Under the optimum conditions, ECL intensity varied linearly with cloperastine hydrochloride concentration from 7.0×10-6g/mL to 1.0×10-4g/mL. The detection limit (S/N=3) was 8.05×10-7g/mL. The relative standard deviation of the ECL intensity and the migration time for 11 consecutive injections of 1.0×10-5g/mL cloperastine hydrochloride was 2.9% and 1.5%, respectively. This method was successfully applied to cloperastine hydrochloride tablet determination. Conclusion The method has been established, validated and applied for determination of cloperastine hydrochloride.
基金Supported by the National Natural Science Foundation of China(20275023)
文摘[ Objective] This study aimed to establish an electrochemiluminescence method for determining the trace molybdenum in plant seeds. [ Method ] The equipment used in this study consisted of an electrogenerated reagent system and a flow-injection chemiluminescence detection system. The optimal electric poten- tial, reagent acidity, flow rate of sample solution, as well as the concentration and alkalinity of luminal were screened to measure the trace molybdenum in plant seeds. [ Result I The unstable molybdenum (III) was on-line electrogenerated from molybdenum (VI) via controlled potential electrolysis technique using a home- made flow-through carbon electrolytic cell at the potential of -0.60 V (vs Ag/AgC1). The method allowed the determination of 5.0 × 10-10 _ 5.0 ×10-7 g/ml mo- lybdenum with a detection limit of 5 × 10 u g/ml molybdenum (VI). The relative standard deviation was 2.6% for the 1.0 × 10 -9 g/ml molybdenum solution in 11 measurements. [ Conclusion] Compared with the previous methods, this electrochemilum^nescence method not only improved the selectivity of the determina- tion, but also avoided the use of toxic reagent mercury.
基金supported by the National Natural Science Foundation of China (22374054)Natural Science Foundation of Hubei Province (2023AFB571)+2 种基金Knowledge Innovation Program of Wuhan-Shuguang Project (2023020201020441)the Fundamental Research Funds for the Central Universities (CCNU22JC006)the Program of Introducing Talents of Discipline to Universities of China (111 program, B17019)。
文摘The anodic oxygen evolution reaction is a well-acknowledged side reaction in traditional aqueous electrochemiluminescence(ECL) systems due to the generation and surface aggregation of oxygen at the electrode, which detrimentally impacts the stability and efficiency of ECL emission. However, the effect of reactive oxygen species generated during water oxidation on ECL luminophores has been largely overlooked. Taking the typical luminol emitter as an example, herein, we employed NiIr single-atom alloy aerogels possessing efficient water oxidation activity as a prototype co-reaction accelerator to elucidate the relationship between ECL behavior and water oxidation reaction kinetics for the first time. By regulating the concentration of hydroxide ions in the electrolyte, the electrochemical oxidation processes of both luminol and water are finely tuned. When the concentration of hydroxide ions in electrolyte is low,the kinetics of water oxidation is attenuated, which limits the generation of oxygen, effectively mitigates the influence of oxygen accumulation on the ECL strength, and offers a novel perspective for harnessing side reactions in ECL systems. Finally, a sensitive and stable sensor for antioxidant detection was constructed and applied to the practical sample detection.