期刊文献+
共找到24篇文章
< 1 2 >
每页显示 20 50 100
Development of a loop‑mediated isothermal amplification assay for detection of Austropeplea tomentosa from environmental water samples
1
作者 Lily Tran Vignesh A.Rathinasamy Travis Beddoe 《Animal Diseases》 2023年第1期35-48,共14页
Lymnaeid snails are key intermediate hosts for the development and survival of Fasciola spp.,the causative agent of Fascioliasis which are economically important parasites infecting humans and livestock globally.The c... Lymnaeid snails are key intermediate hosts for the development and survival of Fasciola spp.,the causative agent of Fascioliasis which are economically important parasites infecting humans and livestock globally.The current control method for treating Fascioliasis is heavily reliant on anthelmintic drugs,particularly Triclabendazole(TCBZ)which has resulted in drug-resistant parasites and poses significant risk as there are no long-term efficacious alternatives available.Sustainable control measures at the farm level could include both parasite and snail control will play an important role in Fasciola spp.control and reduce the reliance on anthelmintic drugs.Implementation of such sustainable control measures requires effective identification of snails on the property however Lymnaeid snails are small and difficult to physically locate.Snail identification using an environmental DNA approach is a recent approach in which physically locating snails are not required.Austropeplea tomentosa,is the primary intermediate snail host for F.hepatica transmission in South-East Australia and we present an in-field loop-mediated isothermal amplification and water filtering method for the detection of A.tomentosa eDNA from water samples to improve current surveillance methods.This methodology is highly sensitive with a detection limit of 5×10^(−6)ng/μL,detected in<20 minutes,with cumulative sample preparation and amplification time under 1 hour.This proposed workflow could assist in monitoring areas to determine the risk of Fascioliasis infection and implement strategies to manage snail populations to ultimately reduce the risk of infection for humans and livestock. 展开更多
关键词 Fasciola spp. SNAIL Molecular detection DNA diagnostics LAMP environmental sampling EDNA
下载PDF
Scanning electron microscopy coupled with energydispersive X-ray spectrometry for quick detection of sulfuroxidizing bacteria in environmental water samples 被引量:1
2
作者 SUN Chengjun JIANG Fenghua +5 位作者 GAO Wei LI Xiaoyun YU Yanzhen YIN Xiaofei WANG Yong DING Haibing 《Chinese Journal of Oceanology and Limnology》 SCIE CAS CSCD 2017年第1期185-191,共7页
Detection of sulfur-oxidizing bacteria has largely been dependent on targeted gene sequencing technology or traditional cell cultivation, which usually takes from days to months to carry out. This clearly does not mee... Detection of sulfur-oxidizing bacteria has largely been dependent on targeted gene sequencing technology or traditional cell cultivation, which usually takes from days to months to carry out. This clearly does not meet the requirements of analysis for time-sensitive samples and/or complicated environmental samples. Since energy-dispersive X-ray spectrometry(EDS) can be used to simultaneously detect multiple elements in a sample, including sulfur, with minimal sample treatment, this technology was applied to detect sulfur-oxidizing bacteria using their high sulfur content within the cell. This article describes the application of scanning electron microscopy imaging coupled with EDS mapping for quick detection of sulfur oxidizers in contaminated environmental water samples, with minimal sample handling. Scanning electron microscopy imaging revealed the existence of dense granules within the bacterial cells, while EDS identified large amounts of sulfur within them. EDS mapping localized the sulfur to these granules. Subsequent 16S rRNA gene sequencing showed that the bacteria detected in our samples belonged to the genus Chromatium, which are sulfur oxidizers. Thus, EDS mapping made it possible to identify sulfur oxidizers in environmental samples based on localized sulfur within their cells, within a short time(within 24 h of sampling). This technique has wide ranging applications for detection of sulfur bacteria in environmental water samples. 展开更多
关键词 sulfur bacteria energy-dispersive X-ray spectrometry scanning electron microscopy bacteria detection environmental water samples 16S rRNA sequencing
原文传递
Application of closed-vessel microwave digestion method for the determination of multi-elements in environmental samples by sequential ICP-AES
3
作者 Xu Liqiang, Shen Wangxing and Zhu Jingfang Shanghai Institute of Metallurgy,Academia Sinica,Shanghai 200050,China 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 1989年第2期69-75,共7页
A closed-vessel microwave digestion method is described for the rapid dissolution of environmental samples such as foods, soils and sediments. Depending on the sample type, 0.1-0.2 g sample was decomposed with HNO3/H2... A closed-vessel microwave digestion method is described for the rapid dissolution of environmental samples such as foods, soils and sediments. Depending on the sample type, 0.1-0.2 g sample was decomposed with HNO3/H2O2 or HNO3 / H2O2/HF acid mixture in a PTFE digestion vessel by using microwave heating for 2-3 min at 500W of microwave power. The solution, or to which 0.5 g of boric acid was added, was diluted to 25-50 ml and directly determined by sequential ICP-AES. The accuracy of the procedure was validated by the analysis of six standard reference materials for 10 elements. Ail results were in a good agreements with the certified values. 展开更多
关键词 microwave digestion environmental sampl sequential ICP-AES elemental analysis.
下载PDF
Determination of polychlorinated biphenyl congeners in environmental samples
4
作者 Chu Shaogang Yang Chun Xu Xiaobai (Research Center for Eco-Environmental Sciences,Chinese Academy of Sciences, Beijing 100085,China ) 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 1996年第1期57-65,共9页
A modified separation method has been developed for determinating polychlorinated biphenyl congeners in environmental samples. Direct treatment of extract with concentrated HzSO4 was employed in the first step for rem... A modified separation method has been developed for determinating polychlorinated biphenyl congeners in environmental samples. Direct treatment of extract with concentrated HzSO4 was employed in the first step for removal of lipids and other interfering substances, then a joint column of alumina-silica gel(Ag+) was applied to separate PCBs fraction from HCH, DDT and its analogs. After this separation, the PCBs fraction was analyzed by capillary gas chromatography with ECD detector and confirmed by GC/MS. The recoveries of individual congeners in Aroclor 1254 through the separation are about 79%-84%. The method is very efficient and useful for determination of trace amount of PCB congeners in environmental samples. 展开更多
关键词 polychlorinated biphenyl capillary gas chromatography environmental samples.
下载PDF
Erratum to “Isolation, Characterization and Antimicrobial Resistance Patterns of Lactose-Fermenter Enterobacteriaceae Isolates from Clinical and Environmental Samples” [Open Journal of Medical Microbiology 5 (2015) 169-176]
5
作者 Israa Abdul Jabbar Ibrahim Tuqa Abdul Kareem Hameed 《Open Journal of Medical Microbiology》 2016年第1期1-2,共2页
The lactose-fermenter Enterobacteriaceae are the most frequent cause of clinical infection in our country. The objective of this study was to isolate and identify the most common lactose-fermenter Enterobacteriaceae f... The lactose-fermenter Enterobacteriaceae are the most frequent cause of clinical infection in our country. The objective of this study was to isolate and identify the most common lactose-fermenter Enterobacteriaceae from clinical samples, including urine, blood, wounds, and sputum, obtained from the local hospital and from environmental samples from a chicken farm, agriculture soil, and water from the Tigris River in Baghdad City. The study also aimed at establishing the antibiotic resistance patterns of the isolated bacteria. A total of 155 bacterial isolates were identified from 10 genera according to the Vitek 2 system. The most common bacterial isolates from the clinical and environmental samples were Escherichia coli and Klebsiella pneumoniae, respectively. The antibiotic resistance patterns showed that all clinical and environmental isolates were multidrug resistant to β-lactam (except carbapenems) drug and aminoglycosides and more sensitive to carbapenems. 展开更多
关键词 ENTEROBACTERIACEAE Lactose Fermenters CLINICAL environmental samples
下载PDF
Rapid HPLC Method for Monitoring Relevant Residues of Pharmaceuticals Products in Environmental Samples
6
作者 Juana Rodriguez Flores Ana Maria Contento Salcedo Lorena Munoz Fernandez 《American Journal of Analytical Chemistry》 2011年第1期18-26,共9页
This work presents a multi-residue analytical method based on solid phase extraction (SPE) followed by high-performance liquid chromatographic (HPLC) with diode array (DAD) detection for the simultaneous determination... This work presents a multi-residue analytical method based on solid phase extraction (SPE) followed by high-performance liquid chromatographic (HPLC) with diode array (DAD) detection for the simultaneous determination of a group of pharmaceutical products that include ten antidepressants and three anticanceri- genic in environmental samples (water and soil). Baseline separation of the studied compounds was obtained on an ultrabase C18 (4.6 mm i.d. × 150 mm, 5 μm particle) column using acetonitrile:phosphate buffer pH 2.5 (35:65 v/v) as mobile phase with a flow rate of 1.5 mL/min. Different aspects including linearity, accuracy, precision and detection and quantification limits were examined in order to validate the proposed method. Detection limits between 1 and 50 ng/mL were obtained for all the target compounds. This method was ap- plied to the analysis of environmental samples as waters and soils of different precedence. Prior, the HPLC determination the samples were purified and enriched using SPE or liquid-liquid extraction (LLE) of the tar- get compounds. 展开更多
关键词 High-Performance Liquid Chromatographic(HPLC) Breast Cancer ANTIDEPRESSANT environmental samples
下载PDF
Novel Screen-Printed All-Solid-State Copper(II)-Selective Electrode for Mobile Environmental Analysis 被引量:1
7
作者 Johannes Schwarz Kathrin Trommer Michael Mertig 《American Journal of Analytical Chemistry》 2016年第7期525-532,共9页
Based on poly(vinyl chloride) membranes, a novel miniaturized screen-printed all-solid-state copper(II)-selective electrode has been developed for applications in environmental monitoring. Performance and applicabilit... Based on poly(vinyl chloride) membranes, a novel miniaturized screen-printed all-solid-state copper(II)-selective electrode has been developed for applications in environmental monitoring. Performance and applicability of the ion-selective electrode (ISE) have been proved by potentiometric investigations. Conducting polymers were used as intermediate layers and as solid contacts between the ion-selective membrane and the graphite transducer. The ion-complexing reagent 2-mercapto-benzoxazole was incorporated into poly(vinyl chloride) membranes. In the concentration range 10<sup>-6</sup> - 10<sup>-2</sup> mol/L, the ISE exhibited a linear Nernstian potential response to copper(II) with an average slope value of 28 mV/decade. The detection limit was 3 × 10<sup>-7</sup> mol/L. The electrode exhibits a short response time (<10 s) and can be used in the range of pH = 3 - 7. Selectivity coefficents against certain interfering ions are investigated. The life time of the electrode under laboratory conditions was approximately 12-month. The electrode was applied in the investigation of different aqueous environmental samples and the electrode characteristics were described. The copper(II) ASS electrode has also successfully been used in potentiometric, complexometric titrations with ethylenediaminetetraacetic acid. 展开更多
关键词 All-Solid-State Copper(II)-Selective Electrode Conducting Polymers Potentiometric Titration environmental samples
下载PDF
A Modified Qu EChERS-DART-MS/MS Technique for High-Throughput Detection of Organophosphate Nerve Agent Hydrolysis Products in Environmental Samples 被引量:2
8
作者 Gang Qu Bo Chen +3 位作者 Shilei Liu Qiaoli Zhang Yang Yang Qingshan Fu 《Journal of Analysis and Testing》 EI CSCD 2023年第2期163-171,共9页
Organophosphate nerve agents(OPNAs)are lethal chemical weapons(CWs)which hydrolyze rapidly to alkyl phosphate compounds in the environment.The identification of alkyl phosphate compounds in the environment is critical... Organophosphate nerve agents(OPNAs)are lethal chemical weapons(CWs)which hydrolyze rapidly to alkyl phosphate compounds in the environment.The identification of alkyl phosphate compounds in the environment is critical for the verification of OPNAs.Currently,due to the complex sample preparation and long detection process for organophosphate nerve agent hydrolysis products(OPNAHPs),their high-throughput determination is difficult.To simplify sample preparation and detection of OPNAHPs from environmental samples,a quick,easy,cheap,effective,rugged and safe(Qu ECh ERS)method for the simultaneous purification of the five OPNAHPs in environmental samples combined with detection through direct analysis in real-time ionization source coupled with tandem mass spectrometer(DART-MS/MS)was developed.An internal standard method was applied for the quantification.The method exhibited a good linearity(R^(2)>0.991)in the range of 1.00 ng/m L-4.00μg/m L.The limits of detection and limits of quantification were 1.00-7.00 ng/m L and 10.0-20.0 ng/m L,respectively.The recoveries of OPNAHPs in environmental samples were between 65.3%and 107%,with relative standard deviations ranged from 1.6%to 19%.In addition,the sample preparation and analysis process for OPNAHPs could be completed in less than 10 min.The results demonstrated that the modified Qu ECh ERS method could quickly and efficiently remove the matrix of environmental samples.Combined with DART-MS/MS,an accurate and high-throughput detection method of OPNAHPs in environmental samples was provided.The developed method has great potential in the fields of early warning,clinical treatment and environmental decontamination. 展开更多
关键词 OPNAHPs QUECHERS DART-MS/MS environmental samples
原文传递
Fluorescence analysis of antibiotics and antibiotic-resistance genes in the environment: A mini review
9
作者 Yuxin Li Chengbin Liu +1 位作者 Qiuju Li Shun Mao 《Chinese Chemical Letters》 SCIE CAS CSCD 2024年第10期82-91,共10页
Antibiotics,as widely used antibacterial drug,exist in various environmental media.Antibiotic residues can affect biological metabolism and lead to bacterial resistance and the formation of antibiotic-resistance genes... Antibiotics,as widely used antibacterial drug,exist in various environmental media.Antibiotic residues can affect biological metabolism and lead to bacterial resistance and the formation of antibiotic-resistance genes,posing a threat to human health and ecological safety.Establishing efficient detection methods for antibiotics and antibiotic-resistance genes has great environmental significance.Fluorescence detection methods,due to their fast response,high sensitivity and specificity,and low-cost,are widely used in chemical and biological sensing.This review first summarizes the pre-treatment methods for different types of environmental samples,and then focuses on the recent advances of fluorescence methods for the detection of antibiotics and antibiotic-resistance genes.Finally,main challenges and future research directions of fluorescence methods for antibiotic and antibiotic-resistance genes detection are discussed.This review highlights the promising prospect of fluorescence methods in-situ detection and monitoring of antibiotics and antibiotic-resistance genes,and provides guidance for the construction of overall risk assessment system of environmental media. 展开更多
关键词 ANTIBIOTICS Antibiotic-resistancegenes Fluorescence detection environmental samples In-situdetection
原文传递
同位素稀释-HRGC-LRMS法测定环境样品中二噁英类多氯联苯 被引量:8
10
作者 刘劲松 谭香萍 +3 位作者 庞晓露 高亮 钟光剑 许行义 《分析测试学报》 CAS CSCD 北大核心 2004年第z1期177-180,共4页
  多氯联苯(PCBs)是一类具有209种同类物的高毒性、难降解、强脂溶性和生物累积性的持久性有机污染物,自从1996年Jensen首次在鹰和鲱鱼中发现PCBs后[1,2],现在已在世界各地不同的环境介质中都发现有PCBs的存在[3].……
关键词 Isotope dilution HRGC - LRMS Dioxin-like PCBs environmental sample
下载PDF
Immunoassay for Cadmium Detection and Quantification 被引量:4
11
作者 GONG-LIANG LIU JU-FANG WANG +2 位作者 ZHI-YONG LI SHI-ZHONG LIANG XIAO-NING WANG 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2009年第3期188-193,共6页
Objective To detect cadmium in environmental and food samples by graphite furnace atomic absorption spectroscopy (GFAAS) and inductively coupled plasma atomic emission spectroscopy (ICPAES). Methods An indirect co... Objective To detect cadmium in environmental and food samples by graphite furnace atomic absorption spectroscopy (GFAAS) and inductively coupled plasma atomic emission spectroscopy (ICPAES). Methods An indirect competitive enzyme-linked immunosorbent assay (IC-ELISA) was developed based on a cadmium-specific monoclonal antibody. IC-ELISA for cadmium in environmental and food samples was evaluated. Results IC-ELISA showed an IC50 of 45.6 μg/L with a detection limit of 1.95 μg/L for cadmium, and showed a mean recovery ranging 97.67%-107.08%. The coefficient of variations for intra- and interassay was 3.41%-6.61% and 4.70%-9.21%, respectively. The correlation coefficient between IC-ELISA and GFAAS was 0.998. Conclusion IC-ELISA can detect and quantify cadmium residue in environmental or food samples. 展开更多
关键词 CADMIUM ITCBE Monoclonal antibody ELISA FOOD environmental samples
下载PDF
The Relations Among Various Markov Chains 被引量:8
12
作者 Hu Di\|he College of Mathematics and Statistics,Wuhan University, Wuhan 430072, China 《Wuhan University Journal of Natural Sciences》 EI CAS 2001年第3期643-648,共6页
Some basic equations and the relations among various Markov chains are established. These works are the bases in the investigation of the theory of Markov chain in random environment.
关键词 Hopf Markov chain Markov chain in random environment skew product Markov chain sample Markov chain in random environment
下载PDF
Free-Standing Membrane Liquid-State Platform for SERS-Based Determination of Norfloxacin in Environmental Samples 被引量:1
13
作者 Jing Liu Wen Liu +3 位作者 Sha-Na Zhou Dong-Mei Wang Zheng-Jun Gong Mei-Kun Fan 《Journal of Analysis and Testing》 EI 2021年第3期217-224,共8页
Surface-enhanced Raman scattering(SERS)has been widely used in various fields due to high sensitivity,but it is hindered by its low repeatability.Here,we explored a highly reproducible free-standing liquid-state platf... Surface-enhanced Raman scattering(SERS)has been widely used in various fields due to high sensitivity,but it is hindered by its low repeatability.Here,we explored a highly reproducible free-standing liquid-state platform(FSM)for monitoring norfloxacin(NOR)in the environmental field.After optimizing the types of nanoparticles(NPs)and pH value in NOR solution,the relative standard deviation(RSD)of FSM SERS analysis can be stabilized below 10%(n≥8),and the R^(2)of the calibration curve in the range of 20μg/L-100μg/L was 0.995.In addition,the results showed that the limit of detection(LOD)(3σ/k)of NOR was 1.3μg/L.Moreover,the NOR in the spiked samples was successfully quantified by FSM,and the recovery rate exceeded 95%.The proposed method has the potential for rapid analysis of drug residues in environmental samples. 展开更多
关键词 SERS NORFLOXACIN Drug residues environmental samples FSM
原文传递
Determination of Triazine Herbicides in Environmental Water Samples by Acetonitrile Inorganic Salt Aqueous Two-Phase Microextraction System 被引量:1
14
作者 Shiqian Gao Gege Wu +4 位作者 Xiaomeng Li Jie Chen Youyi Wu Junxia Wang Zhanen Zhang 《Journal of Analysis and Testing》 EI 2018年第4期322-331,共10页
Acetonitrile inorganic salt aqueous two-phase extraction method was established for the determination of triazine herbicides(simeton,cyanazine,desmetryn,terbumeton,terbuthylazine and dimethametryn)in environmental wat... Acetonitrile inorganic salt aqueous two-phase extraction method was established for the determination of triazine herbicides(simeton,cyanazine,desmetryn,terbumeton,terbuthylazine and dimethametryn)in environmental water samples by high-performance liquid chromatography(HPLC).The extraction solvents types and volume of acetonitrile,the inorganic salt types and amount of(NH_(4))_(2)SO_(4),extraction time and pH of sample solution were optimized by single-factor experiment and central composite design.Under the optimum extraction conditions,all linear ranges were obtained with coefficients of determination(r)≥0.9993.The limits of detection for this proposed method were in the range of 0.16-0.28μg/L for six triazine herbicides.The developed method has been successfully applied to the analysis of target triazine herbicides from lake,canal and moat in real-world water samples.The recoveries of target analytes were in the range from 87.0 to 110.9%and the relative standard deviation was lower than 7.3%. 展开更多
关键词 Acetonitrile inorganic salt Aqueous two-phase microextraction Triazine herbicides environmental water samples High-performance liquid chromatography
原文传递
Flow-Injection Flame Atomic Absorption Determination of Hexavalent Chromium with On-Line Preconcentration on an Anion Imprinted Polymer 被引量:1
15
作者 María Carmen Yebra-Biurrun Jesús Manuel Castro-Romero Nieves Carro-Marino 《American Journal of Analytical Chemistry》 2012年第11期755-760,共6页
A flow injection preconcentration system for the flame atomic absorption spectrometric determination of hexavalent chromium has been developed. The method employs on-line preconcentration of Cr(VI) on a minicolumn pac... A flow injection preconcentration system for the flame atomic absorption spectrometric determination of hexavalent chromium has been developed. The method employs on-line preconcentration of Cr(VI) on a minicolumn packed with Cr(VI)-imprinted poly(4-vinyl pyridineco-2-hydroxyethyl methacrylate) placed into a flow injection system. Hexava-lent chromium was eluted with a small volume of diluted hydrochloric acid into the nebulizer-burner system of a flame atomic absorption spectrometer. An enrichment factor of 550 and a 3σ detection limit of 0.04 μg·L-1 along a sampling frequency of 4 h-1 at a sample flow rate of 3.5 mL·min-1. The relative standard deviation is 2.9% for 1 μg·L-1 Cr(VI) (n = 11). The flow injection system proposed has the advantage of being simpler because the use of expensive and sophisticated instruments is avoided. Ease of use, continuous process and selectivity make this method suitable for Cr(VI) determination in different environmental samples such as sea and river waters, soils and sediments. 展开更多
关键词 Hexavalent Chromium Flame Atomic Absorption Spectrometry PRECONCENTRATION Flow Injection environmental samples
下载PDF
On-line solid-phase extraction using alizarin violet functionalized silica gel for determination of trace lead in environmental samples and wastewater by sequential injection spectrophotometry
16
作者 FAN Jing, ZHU GuiFen, WANG HaiBo & WANG JianJi Henan Key Laboratory for Environmental Pollution Control Key Laboratory for Yellow and Huai River Water Environmental and Pollution Control, Ministry of Education School of Chemical and Environmental Sciences, Henan Normal University, Xinxiang 453007, China 《Science China Chemistry》 SCIE EI CAS 2011年第6期998-1003,共6页
Trace of Pb(Ⅱ) has been on-line separated and enriched from environmental samples and wastewater by using the self-made alizarin violet functionalized silica gel micro-column coupling with a sequential injection samp... Trace of Pb(Ⅱ) has been on-line separated and enriched from environmental samples and wastewater by using the self-made alizarin violet functionalized silica gel micro-column coupling with a sequential injection sampling technology. The determination is based on the color reaction of Pb(Ⅱ) with iodide and crystal violet to form an ionic association complex in the presence of polyvinyl alcohol and hydrochloric acid. The use of the microcolumn can prevent the interference of most familiar metal ions, and therefore improve the selectivity and sensitivity of this analytical technique. The proposed method was used for the determination of Pb(Ⅱ) in environmental samples and wastewater. No statistically significant difference was observed between the results determined by the present method and atomic absorption spectrometry. 展开更多
关键词 on-line solid-phase extraction sequential injection LEAD environmental sample alizarin violet functionalized silica gel
原文传递
Methods for Detection of Viruses in Water and Wastewater
17
作者 Alicja Hryniszyn Magdalena Skonieczna Jaroslaw Wiszniowski 《Advances in Microbiology》 2013年第5期442-449,共8页
Viruses present in water might be harmful for human health and life. Nowadays over 100 pathogenic human virus species occur in water polluted with sewage. Chlorination, which is the most popular disinfection method is... Viruses present in water might be harmful for human health and life. Nowadays over 100 pathogenic human virus species occur in water polluted with sewage. Chlorination, which is the most popular disinfection method is not able to remove easily viruses from treated water. Due to this, it’s necessary to detect viruses in water before treatment in order to determine disinfectant dose and to ensure the sanitary safety level of treated water. The aim of this article is to review viruses detection methods as well as the problems related to implementation of those methods in analysis of water and wastewater samples. 展开更多
关键词 Viruses Analytical Problems environmental samples Detection Methods
下载PDF
Identifying the Risk of SARS-CoV-2 Infection and Environmental Monitoring in Airborne Infectious Isolation Rooms(AIIRs) 被引量:3
18
作者 Zhi-Gang Song Yan-Mei Chen +10 位作者 Fan Wu Lin Xu Bang-Fang Wang Lei Shi Xiao Chen Fa-Hui Dai Jia-Lei She Jian-Min Chen Edward CHolmes Tong-Yu Zhu Yong-Zhen Zhang 《Virologica Sinica》 SCIE CAS CSCD 2020年第6期785-792,共8页
Healthcare workers(HCWs)are at high risk of occupational exposure to the new pandemic human coronavirus,SARSCoV-2,and are a source of nosocomial transmission in airborne infectious isolation rooms(AIIRs).Here,we perfo... Healthcare workers(HCWs)are at high risk of occupational exposure to the new pandemic human coronavirus,SARSCoV-2,and are a source of nosocomial transmission in airborne infectious isolation rooms(AIIRs).Here,we performed comprehensive environmental contamination surveillance to evaluate the risk of viral transmission in AIIRs with 115 rooms in three buildings at the Shanghai Public Health Clinical Center,Shanghai,during the treatment of 334 patients infected with SARS-CoV-2.The results showed that the risk of airborne transmission of SARS-CoV-2 in AIIRs was low(1.62%,25/1544)due to the directional airflow and strong environmental hygiene procedures.However,we detected viral RNA on the surface of foot-operated openers and bathroom sinks in AIIRs(viral load:55.00–3154.50 copies/mL).This might be a source of contamination to connecting corridors and object surfaces through the footwear and gloves used by HCWs.The risk of infection was eliminated by the use of disposable footwear covers and the application of more effective environmental and personal hygiene measures.With the help of effective infection control procedures,none of 290 HCWs was infected when working in the AIIRs at this hospital.This study has provided information pertinent for infection control in AIIRs during the treatment of COVID-19 patients. 展开更多
关键词 SARS-CoV-2 COVID-19 Nosocomial transmission AIIRs environmental sampling
原文传递
Science Letters:Quantification of Helicobacter pylori levels in soil samples from public playgrounds in Spain 被引量:2
19
作者 Leonardo Martín PéREZ Francesc CODONY +3 位作者 Daniela LóPEZ LEYTON Mariana FITTIPALDI Bárbara ADRADOS Jordi MORATó 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2010年第1期27-29,共3页
Helicobacter pylori are ubiquitous Gram-negative bacteria with a high estimated level of infection in the world populations, but a majority of the infected persons are asymptomatic. This pathogen has been classified b... Helicobacter pylori are ubiquitous Gram-negative bacteria with a high estimated level of infection in the world populations, but a majority of the infected persons are asymptomatic. This pathogen has been classified by the World Health Organization as a class I carcinogen and recognized as the causal agent of most peptic ulcers and chronic gastritis that might lead to stomach cancer. Although not all the transmission pathways of these bacteria into humans have been propedy identified, enough data have suggested that the oral-oral or fecal-oral ones are the main infection routes. Helicobacterpylori have been detected in non-treated water and in drinking water, which suggested that water might be an important infection source. As childhood is the critical period of infection, the aim of the present work was to examine the presence of Helicobacterpylori in soil samples from public playing areas of Spanish parks. 展开更多
关键词 Heficobacterpylori Real time polymerase chain reaction (qPCR) environmental soil samples
原文传递
Environmental sampling of volatile organic compounds during the 2018 Camp Fire in Northern California 被引量:1
20
作者 Leslie A.Simms Eva Borras +5 位作者 Bradley S.Chew Bruno Matsui Mitchell M.McCartney Stephen K.Robinson Nicholas Kenyon Cristina E.Davis 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2021年第5期135-147,共13页
Trace analysis of volatile organic compounds(VOCs) during wildfires is imperative for environmental and health risk assessment. The use of gas sampling devices mounted on unmanned aerial vehicles(UAVs) to chemically s... Trace analysis of volatile organic compounds(VOCs) during wildfires is imperative for environmental and health risk assessment. The use of gas sampling devices mounted on unmanned aerial vehicles(UAVs) to chemically sample air during wildfires is of great interest because these devices move freely about their environment, allowing for more representative air samples and the ability to sample areas dangerous or unreachable by humans. This work presents chemical data from air samples obtained in Davis, CA during the most destructive wildfire in California's history-the 2018 Camp Fire – as well as the deployment of our sampling device during a controlled experimental fire while fixed to a UAV. The sampling mechanism was an in-house manufactured micro-gas preconcentrator(μPC) embedded onto a compact battery-operated sampler that was returned to the laboratory for chemical analysis. Compounds commonly observed in wildfires were detected during the Camp Fire using gas chromatography mass spectrometry(GC–MS), including BTEX(benzene, toluene, ethylbenzene, m + p-xylene, and o-xylene), benzaldehyde, 1,4-dichlorobenzene, naphthalene, 1,2,3-trimethylbenzene and 1-ethyl-3-methylbenzene. Concentrations of BTEX were calculated and we observed that benzene and toluene were highest with average concentrations of 4.7 and 15.1 μg/m^(3), respectively. Numerous fire-related compounds including BTEX and aldehydes such as octanal and nonanal were detected upon experimental fire ignition, even at a much smaller sampling time compared to samples taken during the Camp Fire. Analysis of the air samples taken both stationary during the Camp Fire and mobile during an experimental fire show the successful operation of our sampler in a fire environment. 展开更多
关键词 Volatile organic compounds(VOCs) WILDFIRE 2018 Camp Fire Micro preconcentrators environmental sampling Mobile VOC sampling
原文传递
上一页 1 2 下一页 到第
使用帮助 返回顶部