Asymmetrical Fault Current Calculation Method and Influencing Factors Analysis of Droop-Controlled Inverters 被引量:1
1
作者 Huimin Zhao Zhikang Shuai +3 位作者 Jun Ge An Luo Weimin Wu Z.John Shen 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2024年第2期562-573,共12页
Since the fault dynamic of droop-controlled inverter is different from synchronous generators (SGs), protection devices may become invalid, and the fault overcurrent may damage power electronic devices and threaten th... Since the fault dynamic of droop-controlled inverter is different from synchronous generators (SGs), protection devices may become invalid, and the fault overcurrent may damage power electronic devices and threaten the safety of the microgrid. Therefore, it is imperative to conduct a comprehensive fault analysis of the inverter to guide the design of protection schemes. However, due to the complexity of droop control strategy, existing literatures have simplified asymmetric fault analysis of droop-controlled inverters to varying degrees. Therefore, accurate fault analysis of a droop-controlled inverter is needed. In this paper, by analyzing the control system, an accurate fault model is established. Based on this, a calculation method for instantaneous asymmetrical fault current is proposed. In addition, the current components and current characteristics are analyzed. It was determined that fault currents are affected by control loops, fault types, fault distance and nonlinear limiters. In particular, the influences of limiters on the fault model, fault current calculation and fault current characteristics were analyzed. Through detailed analysis, it was found that dynamics of the control loop cannot be ignored, the fault type and fault distance determine fault current level, and part of the limiters will totally change the fault current trend. Finally, calculation and experimental results verify the correctness of the proposed method. 展开更多
关键词 Asymmetrical fault analysis droop control fault current calculation method LIMITER transient fault characteristics
原文传递
Effects of Un-transposed UHV Transmission Line on Fault Analysis of Power Systems
2
作者 王安宁 陈青 周占平 《Transactions of Tianjin University》 EI CAS 2008年第3期231-234,共4页
The conventional fault analysis method based on symmetrical components supposes that the three-phase parameters of un-transposed transmission line are symmetrical in case of fault. The errors caused by the method with... The conventional fault analysis method based on symmetrical components supposes that the three-phase parameters of un-transposed transmission line are symmetrical in case of fault. The errors caused by the method with the symmetrical distributed parameter circuit model as the equivalent circuit of the un-transposed ultra high voltage(UHV) transmission line were studied under both normal operation and fault,and the corresponding problems arising were pointed out. By contrast with electromagnetic transient and power electronics(EMTPE) simulation results with the asymmetrical distributed parameter circuit model of un-transposed line, it is shown that the conventional method cannot show the existence of negative and zero sequences before fault happening and there are many errors on voltage and current after fault happening which are different with fault types. The error ranges of voltage and current are 2.13%-81.13% and -7.82%- -86.15%, respectively. 展开更多
关键词 EMTPE fault calculation SIMULATION un-transposed UHV transmission line
下载PDF
Single-phase-to-ground Fault Detection with Distributed Parameters Analysis in Non-direct Grounded Systems 被引量:18
3
作者 Baowen Liu Hongzhong Ma +1 位作者 Honghua Xu Ping Ju 《CSEE Journal of Power and Energy Systems》 SCIE CSCD 2019年第1期139-147,共9页
The fast and accurate detection of the single-phaseto-ground fault is of great significance for the reliability and safety of the power supply.In this paper,novel algorithms for distribution network protection were pr... The fast and accurate detection of the single-phaseto-ground fault is of great significance for the reliability and safety of the power supply.In this paper,novel algorithms for distribution network protection were proposed with distributed parameters analysis in non-direct grounded systems.At first,novel generating mechanisms of zero-sequence voltage and residual current were proposed.Then the compositions of residue parameters,including residual current and residual admittances,were decomposed in detail.After that,an improved algorithm for a fault resistance calculation of a single phase-to-earth fault was also proposed,and the algorithm is much more convenient as it only needs to measure the variation of the zero-sequence voltage and does not need the prerequisites of the faulty feeder selection.Furthermore,the fault feeder can also be selected by an improved calculation algorithm of zero-sequence admittance of the faulty feeder,which cannot be affected by the asymmetry of the network.Theoretical analysis and the MATALB/Simulink simulation results demonstrate the effectiveness of the proposed algorithms. 展开更多
关键词 fault resistance calculation fault feeder selection non-direct grounded system residual parameters residual current zero-sequence voltage
原文传递