The electrophysiological methods using microelectrodes are not appropriate for the simultaneous measurement of neural activities of many neurons. To overcome the difficulty, the fluorescent imaging technique using vol...The electrophysiological methods using microelectrodes are not appropriate for the simultaneous measurement of neural activities of many neurons. To overcome the difficulty, the fluorescent imaging technique using voltage sensitive dyes can be a powerful technique. The voltage sensitive dyes, however, generally exhibit a relatively small change in their fluorescence intensities, resulting in a low S/N ratio. Additionally, they often exhibit photobleaching and phototoxity. We have therefore improved the fluorescent voltage imaging technique by using a LED as the light source and an electron multiplying (EM)-CCD camera as the fluorescence detector. In this study, we applied our imaging system for the measurement of two kind of molluscan neural activities;one of which is involved in the olfactory processing of the land slug Limax valentianus and the other is involved in the feeding rhythm of the pond snail Lymnaea stagnalis. The system enabled us to measure the neural activities for a long time with a high speed and a high S/N ratio, and the obtained results showed some new physiological findings.展开更多
Background:Determining the Helicobacter pylori (H. pylori) infection state during the gastroscopic process is important but still challenging. The linked color imaging (LCI) technique might emphasize the mucosal color...Background:Determining the Helicobacter pylori (H. pylori) infection state during the gastroscopic process is important but still challenging. The linked color imaging (LCI) technique might emphasize the mucosal color change after H. pylori infection, which might help the diagnosis. In the present study, we aimed to compare the LCI technique with traditional white light imaging (WLI) endoscopy for diagnosing active H. pylori infection.Methods:We collected and analyzed gastroscopic images from 103 patients in our hospital from November 2017 to March 2018, including both LCI and WLI modes. All images were randomly disordered and independently evaluated by four endoscopists who were blinded to the H. pylori status of patients. In addition, the H. pylori state was determined by both rapid urease test and pathology staining. The sensitivity, specificity, positive prediction value (PPV), and negative prediction value (NPV) were calculated for the detection of H. pylori infection. Moreover, the kappa value and interclass correlation coefficient (ICC) were used to evaluate the inter-observer variety by SPSS 24.0 software.Results:Of the 103 enrolled patients, 27 of them were positive for H. pylori infection, while the 76 patients were negative. In total, 388 endoscopic images were selected, including 197 WLI and 191 LCI. The accuracy rate for H. pylori evaluation in the corpus LCI group was significantly higher than other groups (81.2% vs. 64.3%-76.5%, χ2 = 34.852, P < 0.001). Moreover, the corpus LCI group had the optimal diagnostic power with the sensitivity of 85.41% (95% confidence interval [CI]: 76.40%-91.51%), the specificity of 79.71% (95% CI: 74.38%-84.19%), the PPV of 59.42% (95% CI: 50.72%-67.59%), and the NPV of 94.02% (95% CI: 89.95%-96.56%), respectively. The kappa values between different endoscopists were higher with LCI than with WLI (0.433-0.554 vs. 0.331-0.554). Consistently, the ICC value was also higher with LCI than with WLI (0.501 [95% CI: 0.429-0.574] vs. 0.397 [95% CI: 0.323-0.474]). We further analyzed the factors that might lead to misjudgment, revealing that active inflammation might disturb WLI judgment (accuracy rate: 58.70% vs. 76.16%, χ2 = 21.373, P < 0.001). Atrophy and intestinal metaplasia might affect the accuracy of the LCI results (accuracy rate: 66.96% vs. 73.47%, χ2 = 2.027;68.42% vs. 73.53 %, χ2 = 1.594, respectively);however, without statistical significance (P = 0.154 and 0.207, respectively).Conclusions:The application of LCI at the corpus to identify H. pylori infection is reliable and superior to WLI. The inter-observer variability is lower with LCI than with WLI.展开更多
AIM: To assess potential contributions of biliary IgA for crystal agglomeration into gallstones, we visualized cholesterol crystal binding of biliary IgA. METHODS: Crystal binding biliary proteins were extracted from ...AIM: To assess potential contributions of biliary IgA for crystal agglomeration into gallstones, we visualized cholesterol crystal binding of biliary IgA. METHODS: Crystal binding biliary proteins were extracted from human gallbladder bile using lectin affinity chromatography.Biliary IgA was isolated from the bound protein fraction by immunoaffinity chromatography. Pure cholesterol monohydrate crystals were incubated with biliary IgA and fluoresceine isothiocyanate (FITC)conjugated anti IgA at 37 degree. Samples were examined under polarizing and fluorescence light microscopy with digital image processing. RESULTS: Binding of biliary IgA to cholesterol monohydrate crystals could be visualized with FITC conjugated anti IgA antibodies.Peak fluorescence occurred at crystal edges and dislocations. Controls without biliary IgA or with biliary IgG showed no significant fluorescence. CONCLUSION: Fluorescence light microscopy provided evidence for cholesterol crystal binding of biliary IgA. Cholesterol crystal binding proteins like IgA might be important mediators of crystal agglomeration and growth of cholesterol gallstones by modifying the evolving crystal structures in vivo.展开更多
文摘The electrophysiological methods using microelectrodes are not appropriate for the simultaneous measurement of neural activities of many neurons. To overcome the difficulty, the fluorescent imaging technique using voltage sensitive dyes can be a powerful technique. The voltage sensitive dyes, however, generally exhibit a relatively small change in their fluorescence intensities, resulting in a low S/N ratio. Additionally, they often exhibit photobleaching and phototoxity. We have therefore improved the fluorescent voltage imaging technique by using a LED as the light source and an electron multiplying (EM)-CCD camera as the fluorescence detector. In this study, we applied our imaging system for the measurement of two kind of molluscan neural activities;one of which is involved in the olfactory processing of the land slug Limax valentianus and the other is involved in the feeding rhythm of the pond snail Lymnaea stagnalis. The system enabled us to measure the neural activities for a long time with a high speed and a high S/N ratio, and the obtained results showed some new physiological findings.
文摘Background:Determining the Helicobacter pylori (H. pylori) infection state during the gastroscopic process is important but still challenging. The linked color imaging (LCI) technique might emphasize the mucosal color change after H. pylori infection, which might help the diagnosis. In the present study, we aimed to compare the LCI technique with traditional white light imaging (WLI) endoscopy for diagnosing active H. pylori infection.Methods:We collected and analyzed gastroscopic images from 103 patients in our hospital from November 2017 to March 2018, including both LCI and WLI modes. All images were randomly disordered and independently evaluated by four endoscopists who were blinded to the H. pylori status of patients. In addition, the H. pylori state was determined by both rapid urease test and pathology staining. The sensitivity, specificity, positive prediction value (PPV), and negative prediction value (NPV) were calculated for the detection of H. pylori infection. Moreover, the kappa value and interclass correlation coefficient (ICC) were used to evaluate the inter-observer variety by SPSS 24.0 software.Results:Of the 103 enrolled patients, 27 of them were positive for H. pylori infection, while the 76 patients were negative. In total, 388 endoscopic images were selected, including 197 WLI and 191 LCI. The accuracy rate for H. pylori evaluation in the corpus LCI group was significantly higher than other groups (81.2% vs. 64.3%-76.5%, χ2 = 34.852, P < 0.001). Moreover, the corpus LCI group had the optimal diagnostic power with the sensitivity of 85.41% (95% confidence interval [CI]: 76.40%-91.51%), the specificity of 79.71% (95% CI: 74.38%-84.19%), the PPV of 59.42% (95% CI: 50.72%-67.59%), and the NPV of 94.02% (95% CI: 89.95%-96.56%), respectively. The kappa values between different endoscopists were higher with LCI than with WLI (0.433-0.554 vs. 0.331-0.554). Consistently, the ICC value was also higher with LCI than with WLI (0.501 [95% CI: 0.429-0.574] vs. 0.397 [95% CI: 0.323-0.474]). We further analyzed the factors that might lead to misjudgment, revealing that active inflammation might disturb WLI judgment (accuracy rate: 58.70% vs. 76.16%, χ2 = 21.373, P < 0.001). Atrophy and intestinal metaplasia might affect the accuracy of the LCI results (accuracy rate: 66.96% vs. 73.47%, χ2 = 2.027;68.42% vs. 73.53 %, χ2 = 1.594, respectively);however, without statistical significance (P = 0.154 and 0.207, respectively).Conclusions:The application of LCI at the corpus to identify H. pylori infection is reliable and superior to WLI. The inter-observer variability is lower with LCI than with WLI.
文摘AIM: To assess potential contributions of biliary IgA for crystal agglomeration into gallstones, we visualized cholesterol crystal binding of biliary IgA. METHODS: Crystal binding biliary proteins were extracted from human gallbladder bile using lectin affinity chromatography.Biliary IgA was isolated from the bound protein fraction by immunoaffinity chromatography. Pure cholesterol monohydrate crystals were incubated with biliary IgA and fluoresceine isothiocyanate (FITC)conjugated anti IgA at 37 degree. Samples were examined under polarizing and fluorescence light microscopy with digital image processing. RESULTS: Binding of biliary IgA to cholesterol monohydrate crystals could be visualized with FITC conjugated anti IgA antibodies.Peak fluorescence occurred at crystal edges and dislocations. Controls without biliary IgA or with biliary IgG showed no significant fluorescence. CONCLUSION: Fluorescence light microscopy provided evidence for cholesterol crystal binding of biliary IgA. Cholesterol crystal binding proteins like IgA might be important mediators of crystal agglomeration and growth of cholesterol gallstones by modifying the evolving crystal structures in vivo.
基金the National Natural Science Foundation of China(81672520,81870484,61975172,and 82001874,used for procurement of materials and labor cost)Science and Technology Planning Project of Zhejiang(2019C03089,used for procurement of materials)Zhejiang Provincial Natural Science Foundation of China(LR17F050001,used for procurement of materials).