The Application of the Ground Source and Air-to-Water Heat Pumps in Cold Climate Areas 被引量:3
1
作者 Kaspar Tennokese Teet-Andrus Koiv +1 位作者 Alo Mikola Villu Vares 《Smart Grid and Renewable Energy》 2013年第7期473-481,共9页
This article gives an overview of using the ground source heat pump (GSHP) and air-to-water heat pump (A&WHP) in cold climate areas for heating and for domestic hot water production of buildings. Computer simulati... This article gives an overview of using the ground source heat pump (GSHP) and air-to-water heat pump (A&WHP) in cold climate areas for heating and for domestic hot water production of buildings. Computer simulation and analysis were carried out for a typical detached house, with 200 m2 of living area, the heat demand of 9 kW and the average heat demand for DHW production of 1 kW. In heating period the average Coefficient of Performance (COP) of the A&WHP is considerably lower than COP of the GSHP. 展开更多
关键词 ground source heat Pump Air-Water heat Pump heat Requirement COP
下载PDF
Simulation of embedded heat exchangers of solar aided ground source heat pump system 被引量:1
2
作者 王芳 郑茂余 +1 位作者 邵俊鹏 李忠建 《Journal of Central South University》 SCIE EI CAS 2008年第S2期261-266,共6页
Aimed at unbalance of soil temperature field of ground source heat pump system, solar aided energy storage system was established. In solar assisted ground-source heat pump (SAGSHP) system with soil storage, solar ene... Aimed at unbalance of soil temperature field of ground source heat pump system, solar aided energy storage system was established. In solar assisted ground-source heat pump (SAGSHP) system with soil storage, solar energy collected in three seasons was stored in the soil by vertical U type soil exchangers. The heat abstracted by the ground-source heat pump and collected by the solar collector was employed to heating. Some of the soil heat exchangers were used to store solar energy in the soil so as to be used in next winter after this heating period; and the others were used to extract cooling energy directly in the soil by circulation pump for air conditioning in summer. After that solar energy began to be stored in the soil and ended before heating period. Three dimensional dynamic numerical simulations were built for soil and soil heat exchanger through finite element method. Simulation was done in different strata month by month. Variation and restoration of soil temperature were studied. Economy and reliability of long term SAGSHP system were revealed. It can be seen that soil temperature is about 3 ℃ higher than the original one after one year's running. It is beneficial for the system to operate for long period. 展开更多
关键词 SOLAR assisted ground source heat PUMP (ASGSHP) soil storage three DIMENSIONAL simulations heatING and COOLING
下载PDF
Research on single hole heat transfer power of ground source heat pump system 被引量:2
3
作者 ZHAO Fang-hua 《Journal of Groundwater Science and Engineering》 2018年第1期65-70,共6页
In this paper,the single hole heat transfer power of the ground source heat pump system in Hengshui is compared with data gained from thermal response test.The results show that maximum monitoring data of heat transfe... In this paper,the single hole heat transfer power of the ground source heat pump system in Hengshui is compared with data gained from thermal response test.The results show that maximum monitoring data of heat transfer power per meter in summer is 97.1% of the test data,and the average value accounts for 81.8%.The per meter heat power data through on-site thermal response test can provide references for designing engineering project and optimizing ground source heat pump system as these data do not vary greatly from the actual monitoring data. 展开更多
关键词 ground source heat PUMP Monitoring heat TRANSFER POWER Thermal response test
下载PDF
Study on ground source heat pump system zoning and methods in the Northwest of Shandong Province 被引量:2
4
作者 YU Yi-qiang 《Journal of Groundwater Science and Engineering》 2018年第3期171-177,共7页
Based on the basic geology, hydrogeology, engineering geology, geothermal geology and ground source heat pump(GSHP) engineering of the work space, the thesis studies the local shallow geothermal energy. Three conditio... Based on the basic geology, hydrogeology, engineering geology, geothermal geology and ground source heat pump(GSHP) engineering of the work space, the thesis studies the local shallow geothermal energy. Three conditions of the attribute index for the suitability zoning of the northwest of Shandong are determined, namely, hydrodynamic condition, geological and hydrogeological condition and geological environment condition. The assessment result is that the total area of the suitable zone is 205.88 km^2, that of relative suitable zone, 1 407.76 km^2, and that of unsuitable zone, 286.8 km^2. The result conforms to the real development situation and provides experience for similar regions needed for selecting and assigning a value to suitability zoning of GSHP. 展开更多
关键词 ground source heat pump NORTHWEST of SHANDONG Province Engineering GEOLOGY SUITABILITY ZONING
下载PDF
Experimental Investigation on System with Combination of Ground-Source Heat Pump and Solar Collector 被引量:4
5
作者 胡涛 朱家玲 张伟 《Transactions of Tianjin University》 EI CAS 2013年第3期157-167,共11页
This paper presents the heating performance and energy distribution of a system with the combination of ground-source heat pump and solar collector or a solar-assisted ground-source heat pump system (SAGSHPS) by calcu... This paper presents the heating performance and energy distribution of a system with the combination of ground-source heat pump and solar collector or a solar-assisted ground-source heat pump system (SAGSHPS) by calculation and experiment.The results show that the average absolute error is less than 0.6 ℃ and the relative error is less than 5% under the pulse load when the analytical solution to the 2-D solid cylindrical source model is used for the SAGSHPS.The coefficient of performance (COP) of the SAGSHPS is 2.95-4.70.The average fluid temperature in the borehole heat exchanger can increase by 3 ℃ with the assistance of solar collector,which will improve the COP of the heat pump by approximately 10% from the experimental data.The energy contributions to the total heating load of soil,electricity and solar are 56.30%,36.87% and 6.83%,respectively. 展开更多
关键词 ground-source heat PUMP solar energy heating performance BOREHOLE heat EXCHANGER
下载PDF
Monitoring actual performance of ground source heat pump system using GPRS-based data transmission: A case analysis in Tangshan 被引量:2
6
作者 杜红普 孔祥飞 +1 位作者 李敏 齐承英 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第4期1554-1562,共9页
The energy efficiency monitoring is an essential precondition for ground source heat pump system's controlling and energy saving operation. Based on the data monitoring applied in the school building, this work is... The energy efficiency monitoring is an essential precondition for ground source heat pump system's controlling and energy saving operation. Based on the data monitoring applied in the school building, this work is focused on the parameters acquisition and operation analysis of the GSHP system in Tangshan. Results show the average COPs(coefficient of performance) are2.85 and 2.70 in summer and winter, respectively, and heat(cold) unbalance underground existed after whole year operation. The analysis of data also indicates that the direct borehole air-conditioning saved some power consumption obviously in the early stage of summer and energy saving of the GSHP system depended remarkably on its operation and management level. Besides the observation points of ground temperature are laid for a large-scale GSHP system, and the hydraulic balance of the pipes group needs to be concerned specially in safeguarding better reliability. 展开更多
关键词 ground source heat pump monitoring operation performance
下载PDF
Research on Performance of Ground-Source Heat Pump Double U Underground Pipe Heat Exchange 被引量:1
7
作者 Youyin Jing Jing Hou Peng Yang 《Open Journal of Modelling and Simulation》 2013年第1期1-6,共6页
This paper uses FLUENT software building the three-dimensional unsteady state model of ground source heat pump single U and double U underground pipe to study on heat exchange of underground pipe system in the conditi... This paper uses FLUENT software building the three-dimensional unsteady state model of ground source heat pump single U and double U underground pipe to study on heat exchange of underground pipe system in the condition of unsteady state long-term continuous running, analyzes the change of soil temperature filed around underground pipe and performance of underground pipe heat exchange between single U and double U pipe system. The results show that double U pipe system is better than single U system, which can improve unit depth heat exchange efficiency, reduce the number of wells and reduce the initial investment. 展开更多
关键词 ground-source heat PUMP DOUBLE U UNDERground PIPE heat Exchange Soil Temperature Field
下载PDF
Experiments Using Capillary Mat as Ground Heat Exchanger for Ground Source Heat Pump Heating Application
8
作者 Arif Widiatmojo Shrestha Gaurav +5 位作者 Takeshi Ishihara Akira Tomigashi Kasumi Yasukawa Youhei Uchida Shohei Kaneko Mayumi Yoshioka 《Energy and Power Engineering》 2019年第11期363-378,共16页
The cooling and heating of spaces are among the largest sources for household’s energy demand. Ground Source Heat Pump (GSHP) is a promising technology to reduce the energy for cooling and heating purposes. However, ... The cooling and heating of spaces are among the largest sources for household’s energy demand. Ground Source Heat Pump (GSHP) is a promising technology to reduce the energy for cooling and heating purposes. However, the major obstacle hindering the utilization of this technology is the high initial cost, especially for the installation of ground coupled heat exchanger. The horizontal closed-loop system offers lower installation cost, as it requires no vertical borehole construction. Instead, the heat exchangers can be installed in shallow trenches that may be excavated, by small excavator or even by human labor. This paper presents the comparison of two different heat exchangers, namely, the capillary mat and the widely used slinky pipe. Both heat exchangers are connected to a heat pump, where continuous heating tests were carried out for 165 hours (~7 days) for each configuration. The purpose of this research is to show the performance of capillary mat in comparison to slinky pipe. Despite during the entire test for capillary mat required 6% higher electricity consumption, compared to slinky heat exchanger, the results still suggest the potential use of capillary mat as alternative to slinky heat exchanger. Additionally, the results also highlight the high hydraulic resistance of installed capillary mat heat exchangers may become the major disadvantage of the capillary mat. 展开更多
关键词 HORIZONTAL heat EXCHANGER ground source heat PUMP CAPILLARY MAT
下载PDF
Comprehensive Benefit Analysis of Direct Expansion Ground Source Heat Pump System
9
作者 Yuefen Gao Yingxin Peng Juanjuan Liu 《Energy and Power Engineering》 2013年第2期76-81,共6页
Direct Expansion Ground Source Heat Pump (DXGSHP) system directly extracts heat or cold energy from ground by consuming electricity to provide for space conditioning. Compared with the currently widely-used secondary ... Direct Expansion Ground Source Heat Pump (DXGSHP) system directly extracts heat or cold energy from ground by consuming electricity to provide for space conditioning. Compared with the currently widely-used secondary loop Ground Couple Heat Pump (GCHP) system, it has higher energy efficiency, lower operating costs, and less environmental impact. A case study is carried out in this paper. The subject is a residential building located in Beijing, China. It is assumed that the building adopts the DXGSHP system and the GCHP system respectively. Annual loads and energy consumption are simulated and computed. Then the initial cost, operating cost and CO2 emission are calculated. The economic benefit is analyzed with the Payback Time method and the Dynamic Annual Cost Value method. The environmental benefit is discussed mainly by comparing the CO2 emission savings. The results show that the DXGSHP system has higher initial costs, but lower operating costs, and less greenhouse gas emissions. The DXGSHP system has better comprehensive benefits than the GCHP system. 展开更多
关键词 Direct EXPANSION ground source heat PUMP ECONOMIC BENEFIT ENVIRONMENTAL BENEFIT
下载PDF
Analysis of Thermodynamic Characteristic Changes in Direct Expansion Ground Source Heat Pump Using Hydrofluoroolefins (HFOs) Substituting for HFC-134a
10
作者 Yuefen Gao Honglei Zhao +1 位作者 Yingxin Peng Tony Roskilly 《Energy and Power Engineering》 2013年第2期11-17,共7页
HFO-1234yf and HFO-1234ze[E] have low global warming potential and zero ozone depletion potential. If they are used in the direct expansion ground source heat pump system substituting for HFC-134a, the system will be ... HFO-1234yf and HFO-1234ze[E] have low global warming potential and zero ozone depletion potential. If they are used in the direct expansion ground source heat pump system substituting for HFC-134a, the system will be beneficial to mitigating climate change. This study aims to find out the thermodynamic characteristics of the direct expansion ground source heat pump system using HFO-1234yf or HFO-1234ze[E] by theoretical calculation. The results indicate that HFO-1234yf system in an actual cycle has the highest COP. HFO-1234yf and HFO-1234ze[E] have such smaller capacity per unit of swept volume that they need larger compression capacity if providing the same heating or cooling loads. For a given unit when HFC-134a is replaced with HFO-1234yf or HFO-1234ze[E], the capacity will decrease. More refrigerant charge is required in the HFO-1234yf or HFO-1234ze[E] system. The results also present that more refrigerant charge is required in the cooling mode than in the heating mode. 展开更多
关键词 Direct EXPANSION ground source heat PUMP (DXGSHP) THERMODYNAMIC Performance HFO-1234YF HFO-1234ze[E] HFC-134A
下载PDF
Application of Ground Source Heat Pump to a Supermarket in Portugal
11
作者 Joao Garcia Luis Coelho +3 位作者 Rita Cerdeira Burkhard Sanner Philippe Lentz Nicolas Frechin 《Journal of Civil Engineering and Architecture》 2011年第3期241-247,共7页
The objective of the present paper is to describe a technical and economical visibility study of the application of ground source heat pumps (GSHP) in a supermarket in Portugal. The study was developed under the Eur... The objective of the present paper is to describe a technical and economical visibility study of the application of ground source heat pumps (GSHP) in a supermarket in Portugal. The study was developed under the European project "Integration of Geothermal Energy Into Industrial Application - IGEIA", project number EIE 06/001, supported by the Intelligent Energy for Europe, IEE, of EACI, European Commission. In general for supermarkets installed in single buildings, the building envelope has higher rates of envelope areas per indoor air volume. In Portugal this fact produces high need of heating during the winter season and high cooling needs during the summer season. Inside the building there are strong internal heat loads produced by high densities of lights and equipments. However these internal loads are not distributed uniformly. There are some areas with high production of heat but there are others with production of cooling. Therefore the acclimatization of this kind of buildings is not so easy and the balance of heating and cooling needs is depending of different parameters which should be well evaluated. The energy consummation of the cold display cases and deep freezers in market area and storage is also very high. The different energy needs could be studied in an integrated way and could be partially satisfied by geothermal energy using ground source heat pumps. At the same time the boreholes could be used as an energy reservoir increasing the efficiency of whole system. Four different climatic zones in Portugal were selected, (north coast, interior north, south coast and interior south) using the same system. The results of the study show that the all energy needs can by partially satisfied by geothermal energy but they need to be integrated to increase the global efficiency. The paper shows that the geothermal energy can be an attractive application for the supermarkets in Portugal if the energy solution is studied in an integrated way and if it is also considered as a cost the emissions of CO2 avoid by the new system. 展开更多
关键词 Geothermal energy ground source heat pump high efficiency
下载PDF
Evaluation of suitability area by ground source heat pump system in Baotou plain
12
作者 WANG Chunpeng WANG Qinghua +2 位作者 FENG Lei FENG Ye CHENG Sanhuan 《Global Geology》 2014年第3期176-181,共6页
According to the elements of hydrogeological conditions,lithology,stratigraphic thermal physical parameters,construction technology and economic rational elements,the evaluation system of ground source heat pump( GSHP... According to the elements of hydrogeological conditions,lithology,stratigraphic thermal physical parameters,construction technology and economic rational elements,the evaluation system of ground source heat pump( GSHP) were established in Baotou plain. The factor weights were determined by using analytic hierarchy process,and the comprehensive element method was selected to evaluate the region suitability of GSHP system. The results show that the suitable area is 559. 63 km2 for utilizing GSHP in the studied area,accounting for 62. 58% of the total area; while the unsuitable area is 334. 60 km2,accounting for37.42%. The evaluating results can provide not only a scientific basis for development and utilization rationally of shallow geothermal heat in Baotou,but also offer an important reference to the other areas. 展开更多
关键词 Baotou plain ground source heat pump suitability area evaluation: analytic hierarchy process comprehensive element method
下载PDF
Possibilities of Reducing Energy Consumption by Optimization of Ground Source Heat Pump Systems in Babylon, Iraq
13
作者 Jenny Lindblom Nadhir Al-Ansari Qais Al-Madhlom 《Engineering(科研)》 2016年第3期130-139,共10页
Iraq is located in the Middle East with an area that reaches 437,072 km2 and a population of about 36 million. This country is suffering from severe electricity shortage problems which are expected to increase with ti... Iraq is located in the Middle East with an area that reaches 437,072 km2 and a population of about 36 million. This country is suffering from severe electricity shortage problems which are expected to increase with time. In this research, an attempt is made to minimize this problem by combining the borehole thermal energy storage (BTES) with a heat pump, the indoor temperature of a residential building or other facility may be increased or reduced beyond the temperature interval of the heat carrier fluid. Due to the relatively high ground temperature in Middle Eastern countries, the seasonal thermal energy storages (STES) and ground source heat pump (GSHP) systems have a remarkable potential, partly because the reduced thermal losses from the underground storage and the expected high COP (ratio of thermal energy gain to required driving energy (electricity)) of a heat pump, partly because of the potential for using STES directly for heating and cooling. In this research, groundwater conditions of Babylon city in Iraq were investigated to evaluate the possibility of using GSHP to reduce energy consumption. It is believed that such system will reduce consumed energy by about 60%. 展开更多
关键词 ground source heat Pump Seasonal Thermal Energy Storages Energy Saving BABYLON Iraq
下载PDF
Research on ground heat exchanger of Ground Source Heat Pump technique
14
作者 LIUDong-sheng SUNYou-hong GAOKe WUXiao-hang 《Journal of Geoscientific Research in Northeast Asia》 2004年第2期196-199,共4页
Ground Source Heat Pump technique and its operating principle are described in this paper. Ground heat exchanger is the key technique of ground source heat pump and its patterns are discussed. Software is helpful to d... Ground Source Heat Pump technique and its operating principle are described in this paper. Ground heat exchanger is the key technique of ground source heat pump and its patterns are discussed. Software is helpful to design ground heat exchanger. A project of Chinese Ground Source Heat Pump is introduced and its market is more and more extensive. 展开更多
关键词 ground source heat Pump ground heat exchanger SOFTWARE DESIGN
下载PDF
Arrangement Strategy of Ground Heat Exchanger with Groundwater 被引量:4
15
作者 李太禄 朱家玲 张伟 《Transactions of Tianjin University》 EI CAS 2012年第4期291-297,共7页
The orientation strategy of side pipe and the heat transfer performance of six ground heat exchangers(GHEs) were optimized by numerical simulation,with soil being treated as a porous medium.An experiment on the heat t... The orientation strategy of side pipe and the heat transfer performance of six ground heat exchangers(GHEs) were optimized by numerical simulation,with soil being treated as a porous medium.An experiment on the heat transfer of four GHEs was carried out in 2010.Results indicate that the velocity field is disturbed by GHEs.The optimal orientation strategy of side pipe is that the upward pipe is located upstream and the downward pipe downstream.The space between GHEs should be appropriately adjusted,depending on the direction and flow velocity.Groups of GHEs should be installed perpendicular to the mainstream in a single row,but if the acreage does not meet the requirements,GHEs should be installed in staggered multiple rows.Fewer GHEs parallel to the mainstream strengthen the heat transfer.Moreover,numerical results agree well with the test data,with the maximum relative error being less than 7.7%. 展开更多
关键词 ground source heat pump ground heat exchanger groundWATER GEOTHERMICS
下载PDF
Numerical Simulation of Heat Transfer Characteristics of Horizontal Ground Heat Exchanger in Frozen Soil Layer 被引量:2
16
作者 王华军 赵军 《Transactions of Tianjin University》 EI CAS 2007年第3期200-204,共5页
A simplified numerical model of heat transfer characteristics of horizontal ground heat exchanger (GHE) in the frozen soil layer is presented and the steady-state distribution of temperature field is simulated. Numeri... A simplified numerical model of heat transfer characteristics of horizontal ground heat exchanger (GHE) in the frozen soil layer is presented and the steady-state distribution of temperature field is simulated. Numerical results show that the frozen depth mainly depends on the soil′s moisture content and ambient temperature. The heat transfer loss of horizontal GHE tends to grow with the increase of the soil′s moisture content and the decrease of ambient temperature. Backfilled materials with optimal thermal conductivity can reduce the thermal loss effectively in the frozen soil. The applicability of the Chinese national standard “Technical Code for Ground Source Heat Pump (GB 50366-2005)” is verified. For a ground source heat pump project, the feasible layout of horizontal GHE should be determined based on the integration of the soil′s structure, backfilled materials, weather data, and economic analysis. 展开更多
关键词 ground source heat pump horizontal ground heat exchanger frozen soil layer heat transfer
下载PDF
Thermal Analysis of the Ground Properties with a Single Borehole Heat Exchanger
17
作者 王尧萍 周亚素 WU Shen-yi 《Journal of Donghua University(English Edition)》 EI CAS 2010年第5期610-613,共4页
The effect of ground properties with heat conduction between soil and ground loop heat exchangers(GLHEs)has been analyzed.A finite line source model proposed by Cui,Yang,and Fang is used.Far field radius is defined.Th... The effect of ground properties with heat conduction between soil and ground loop heat exchangers(GLHEs)has been analyzed.A finite line source model proposed by Cui,Yang,and Fang is used.Far field radius is defined.The analyses for a 1.5m borehole line source in three kinds of soil conditions:damp and breeze(D.B.),damp and heavy(D.H.),and saturated and heavy(S.H.)are carried out.The results of the comparisons show that in the condition of continuous operation,the variation of the far field radius is related to soil thermal conductivity.The rate of heat transfer will decrease after long time operation.And then soil condition will not influence the far field radius obviously. 展开更多
关键词 ground source heat pump finite line source model far field radius
下载PDF
Development of Instantaneous Hot Water Dispenser Based on Water Source Heat Pump
18
作者 Satoshi Yoshida Ryozo Ooka +1 位作者 Toshiyuki Hino Kazuo Kodama 《Journal of Energy and Power Engineering》 2014年第10期1703-1711,共9页
Natural energy use is important to reduce the energy consumption of buildings. However, further reducing energy consumption with traditional systems is difficult. Therefore, we proposed a MMHP (multi-source and multi... Natural energy use is important to reduce the energy consumption of buildings. However, further reducing energy consumption with traditional systems is difficult. Therefore, we proposed a MMHP (multi-source and multi-use heat pump) to achieve higher efficiency than traditional systems. The MMHP system connects multiple heat sources such as solar heat, the ground, and air and multiple heat uses such as cooling, heating, and a hot water dispenser with a water loop. Each type of heat use side can utilize heat efficiently. However, there is a distinct lack of highly efficient hot water dispensers available. Therefore, we developed the IHWD WS (instantaneous hot water dispenser based on a water source) heat pump. In this study, we developed a prototype of the IHWD WS heat pump. The coefficient of performance of the IHWD WS heat pump was 5.2-8.5 throughout a year. When it is improved, COP (coefficient of performance) is expected to be 9.3-9.9. 展开更多
关键词 heat pumps hot water EFFICIENCY COP ground source.
下载PDF
Prediction and parametric analysis of 3D borehole and total internal thermal resistance of single U-tube borehole heat exchanger for ground source heat pumps
19
作者 Kun Zhou Jinfeng Mao +2 位作者 Yong Li Hua Zhang Zhongkai Deng 《Energy and Built Environment》 2023年第2期179-194,共16页
The borehole and total internal thermal resistance are both significant parameters in evaluating the thermal performance of the ground source heat pump.This study aimed to obtain the accurate correlation of the 3D bor... The borehole and total internal thermal resistance are both significant parameters in evaluating the thermal performance of the ground source heat pump.This study aimed to obtain the accurate correlation of the 3D borehole and total internal thermal resistance(R_(b,3D)and R_(a,3D))and analyze the impacts of parameters on the R_(b,3D)and R_(a,3D).Firstly,eight parameters affecting the R_(b,3D)and R_(a,3D),including the borehole diameter,pipe diameter,pipe-pipe distance,borehole depth,soil thermal conductivity,grout thermal conductivity,pipe thermal conductivity,and fluid velocity inside the pipe,were considered and an L-54 design matrix was generated.Then,the 3D numerical model,coupling with the four-resistance model,was proposed to calculate R_(b,3D)and R_(a,3D)for each case.After that,the response surface methodology was employed to obtain and verify the correlation of R_(b,3D)and R_(a,3D),which were compared with the existing resistance calculation methods.Lastly,analysis of variance was carried out to reveal parameters that have statistically significant impacts on the R_(b,3D)and R_(a,3D).Results show that the rationality and accuracy of the correlation of R_(b,3D)and R_(a,3D)can be verified by the determination coefficient and P value of regression model,as well as the P value of lack-of-fit.The existing resistance calculation methods are more or less inaccurate and the discrepancies in some cases can be up to 86.74%and 111.35%for the borehole and total internal thermal resistance.The pipe and grout thermal conductivity,pipe and borehole diameter,and the pipe-pipe distance can be seen as the significant contributory factors to the variation of R_(b,3D)and R_(a,3D). 展开更多
关键词 ground source heat pump Borehole thermal resistance Total internal thermal resistance Four-resistance model Response surface methodology
下载PDF
邻域自适应粒子群算法求解地源热泵区域能源系统鲁棒优化调度问题
20
作者 吴亮红 王维 +1 位作者 张红强 贾睿 《控制理论与应用》 EI CAS CSCD 北大核心 2024年第6期1089-1100,共12页
针对地源热泵区域能源系统中冷热负荷和机组效能的不确定性,本文提出了一种考虑双重不确定性的鲁棒优化调度方法.首先,基于多面体不确定模型描述调度模型中的鲁棒变量.然后,针对建筑冷热负荷不确定性,采用对偶原理将双层优化模型等价为... 针对地源热泵区域能源系统中冷热负荷和机组效能的不确定性,本文提出了一种考虑双重不确定性的鲁棒优化调度方法.首先,基于多面体不确定模型描述调度模型中的鲁棒变量.然后,针对建筑冷热负荷不确定性,采用对偶原理将双层优化模型等价为单层优化模型;对于机组效能不确定性,采用场景法进行分析.最后,采用多目标优化约束处理方法处理鲁棒优化调度模型中的约束条件.同时,为更加高效、准确求解所构建的优化调度模型,提出了一种邻域自适应粒子群优化算法(NAPSO).实验结果表明,在制冷和制热工况下,与经验运行策略相比,本文所提方法可分别减少7.22%和5.55%的系统运行成本,是一种解决地源热泵区域能源系统鲁棒优化调度的有效方法. 展开更多
关键词 地源热泵 鲁棒优化调度 邻域自适应 粒子群优化 不确定性
下载PDF