期刊文献+
共找到9篇文章
< 1 >
每页显示 20 50 100
Off-label-use of sulfur-hexafluoride in voiding urosonography for diagnosis of vesicoureteral reflux in children:A survey on adverse events 被引量:1
1
作者 Alexander Sauer Clemens Wirth +7 位作者 Isabel Platzer Henning Neubauer Simon Veldhoen Alexander Dierks Reinhard Kaiser Andreas Kunz Meinrad Beer Thorsten Bley 《World Journal of Clinical Pediatrics》 2017年第1期52-59,共8页
AIM To evaluate the risk profile of sulfur hexafluoride in voiding urosonography(VUS) based on a large cohort of children.METHODS Since 2011 sulfur hexafluoride(SH,SonoV ue?,Bracco,Italy) is the only ultrasound contra... AIM To evaluate the risk profile of sulfur hexafluoride in voiding urosonography(VUS) based on a large cohort of children.METHODS Since 2011 sulfur hexafluoride(SH,SonoV ue?,Bracco,Italy) is the only ultrasound contrast available in the European Union and its use in children has not been approved.Within a 4-year-period,531 children with suspected or proven vesicoureteral reflux(f/m = 478/53; mean age 4.9 years; 1 mo-25.2 years) following parental informed consent underwent VUS with administration of 2.6 ± 1.2 mL SH in a two-center study.A standardizedtelephone survey on adverse events was conducted three days later.RESULTS No acute adverse reactions were observed.The survey revealed subacute,mostly self-limited adverse events in 4.1%(22/531).The majority of observed adverse events(17/22) was not suspected to be caused by an allergic reaction: Five were related to catheter placement,three to reactivated urinary tract infections,five were associated with perineal disinfection before voiding urosonography or perineal dermatitis and four with a common cold.In five patients(0.9%) hints to a potential allergic cause were noted: Perineal urticaria was reported in three interviews and isolated,mild fever in two.These were minor self-limited adverse events with a subacute onset and no hospital admittance was necessary.Ninety-six point two percent of the parents would prefer future VUS examinations with use of SH.CONCLUSION No severe adverse events were observed and indications of self-limited minor allergic reactions related to intravesical administration of SH were reported in less than 1%. 展开更多
关键词 Voiding urosonography Ultrasound contrast agent Vesicoureteral reflux SonoV ue Adverse events Sulfur hexafluoride
下载PDF
Detecting Photoacoustic Signals of Sulfur Hexafluoride at Varying Microphone Positions
2
作者 Wittmann S. Murphy Han Jung Park 《Open Journal of Physical Chemistry》 2016年第3期49-53,共5页
Photoacoustic spectroscopy was used to test the photoacoustic properties of sulfur hexafluoride, an optically thick and potent greenhouse gas. While exploring the photoacoustic effect of sulfur hexafluoride, the effec... Photoacoustic spectroscopy was used to test the photoacoustic properties of sulfur hexafluoride, an optically thick and potent greenhouse gas. While exploring the photoacoustic effect of sulfur hexafluoride, the effects of the position of the microphone within a gas cell were determined. Using a 35 cm gas cell, microphones were positioned at 17.5 cm, the middle of the gas cell, 12.5 cm, 7.5 cm, and 2.5 cm from the window of the cell. From the photoacoustic signal produced for each resonance frequency at each microphone position, the effects of acoustic pressure produced at each position on the signal recorded were observed. This is the first study done by experimentation with the photoacoustic effect to show that standing waves have different amplitudes at different microphone positions. 展开更多
关键词 Photoacoustic Effect Sulfur hexafluoride Gas Detection Microphone Placement Acoustic Wave Formation
下载PDF
Selective adsorption of SF_(6) in covalent-and metal-organic frameworks 被引量:1
3
作者 Xianqiang Zheng Yanlong Shen +2 位作者 Shitao Wang Ke Huang Dapeng Cao 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2021年第11期88-95,共8页
Sulfur hexafluoride(SF_(6))is an extremely severe greenhouse gas.It is an urgently important mission to find excellent candidates for selective adsorption of SF_(6),in order to reduce the emission of SF_(6) facilities... Sulfur hexafluoride(SF_(6))is an extremely severe greenhouse gas.It is an urgently important mission to find excellent candidates for selective adsorption of SF_(6),in order to reduce the emission of SF_(6) facilities.Here,we adopt the molecular simulation method to systematically explore the selective adsorption of SF_(6) in 22 kinds of representative covalent-and metal-organic frameworks.Results indicate that COF-6 is a promising candidate for the SF_(6) adsorption at low pressure P<20 kPa because of its small pore size,while MOF-180 and PAF-302 are excellent candidates at high pressure P=2×10^(3) kPa due to their large Brunauer-Emmett-Teller specific surface area(BET SSA)and pore volumes.For the two cases of the power industry(X_(SF_(6))=0.1)and the semiconductor industry(X_(SF_(6))=0.002)environments,COF-6 and ZIF-8 are fairly promising candidates for selective adsorption of SF_(6) from the SF_(6)/N_(2) mixtures,because they not only present the high selectivity,but also the large adsorption capacity at ambient environment,which can be considered as potential adsorbents for selective adsorption of SF_(6) at ambient conditions. 展开更多
关键词 Sulfur hexafluoride(SF_(6)) Metal-organic frameworks Molecular simulation Covalent-organic frameworks ADSORPTION SEPARATION
下载PDF
SF<sub>6</sub>Byproducts in High-Humidity Environment: an Experimental Evaluation between 200<sup>o</sup>C and 500<sup>o</sup>C 被引量:1
4
作者 Yu Wang Li Li Weijian Yao 《Journal of Electromagnetic Analysis and Applications》 2011年第6期179-183,共5页
Abstract: In the occurrence of arc discharges, spark discharges, corona discharges and overheated faults in electrical equipment, SF 6would be decomposed to complicated byproducts, such as SO2 , H2S and HF. Analyzing ... Abstract: In the occurrence of arc discharges, spark discharges, corona discharges and overheated faults in electrical equipment, SF 6would be decomposed to complicated byproducts, such as SO2 , H2S and HF. Analyzing these byproducts is an effective method to judge the internal operation condition of electric equipment. In order to study characters of SF6byproducts at different temperature of overheated faults in the electric equipment, a series of overheated faults of electric equipment were simulated. SF6is very stable and not significantly decomposed at 200oC, 250oC and 300oC. SF6is significantly decomposed to SO2, H2S and HF at 350oC. The concentration of SO2, H2S and HF was 7.2, 1.6 and 1.9 μL/L after heating for 5 hours in environment of SF6with 3616 μL/L water, and it was increased to 23.0, 3.0 and 1.2 μL/L 3 hours later. SF6is more easily to be decomposed and decomposed more rapidly at higher temperature. The concentration of SO2, H2S and HF was 62.2, 15.6 and 3.6 μL/L after heating for 5 hours in environment of SF6with 4064 μL/L water, and it was increased to 91.4, 25.2 and 2.3 μL/L 3 hours later. SF6will be decomposed to format HF, which is strongly corrosive and whose concentration is likely to decrease when it is above a certain concentration. 展开更多
关键词 SULFUR hexafluoride Overheating Faults BYPRODUCTS SULFUR Dioxide Sulfureted Hydrogen Hydrofluoric Acid
下载PDF
浅谈六氟化硫气体介质的危害
5
作者 张瑞梅 《管理观察》 2008年第14期148-150,共3页
SF6气体因其优异的绝缘、灭弧性能及化学稳定性,已被广泛地应用在电力设备中,如高压断路器、变压器、互感器、电容器、避雷器、熔断器、管道母线等。随着SF6气体使用量的增加,范围的扩大,人们对其在使用过程中产生的危害有进一步的认识... SF6气体因其优异的绝缘、灭弧性能及化学稳定性,已被广泛地应用在电力设备中,如高压断路器、变压器、互感器、电容器、避雷器、熔断器、管道母线等。随着SF6气体使用量的增加,范围的扩大,人们对其在使用过程中产生的危害有进一步的认识。至2030年,六氟化硫气体将被禁止使用。 展开更多
关键词 六氟化硫气体Sulphur hexafluoride gas 绝缘材料Insulation materials 高压开关设备HV switchgears 环境污染envi ronment pollution
下载PDF
Corrosion and wear resistance of coatings produced on AZ31 Mg alloy by plasma electrolytic oxidation in silicate-based K2TiF6 containing solution:Effect of waveform
6
作者 Maryam Rahmati Keyvan Raeissi +2 位作者 Mohammad Reza Toroghinejad Amin Hakimizad Monica Santamaria 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2022年第9期2574-2587,共14页
In this research,plasma electrolytic oxidation coatings were prepared on AZ31 Mg alloy in a silicate-based solution containing K_(2)TiF_(6) using bipolar and soft sparking waveforms with 10,20,and 30%cathodic duty cyc... In this research,plasma electrolytic oxidation coatings were prepared on AZ31 Mg alloy in a silicate-based solution containing K_(2)TiF_(6) using bipolar and soft sparking waveforms with 10,20,and 30%cathodic duty cycles.The coatings displayed a net-like surface morphology consisted of irregular micro-pores,micro-cracks,fused oxide particles,and a sintered structure.Due to the incorporation of TiO_(2) colloidal particles and the cathodic pulse repair effect,most of the micro-pores were sealed.Long-term corrosion performance of the coatings was investigated using electrochemical impedance spectroscopy during immersion in 3.5 wt.%NaCl solution up to 14 days.The coating grown by the soft sparking waveform with a 20%cathodic duty cycle having the lowest porosity(6.2%)and a sharp layer concentrated in F element at the substrate/coating interface shows the highest corrosion resistance.The friction coefficient of this coating has remained stable during the sliding even under 5 N normal load,showing relatively higher wear resistance than other coatings.The coating produced using the equivalent unipolar waveform,as the reference specimen,showed the highest friction coefficient and the lowest wear resistance despite its highest micro-hardness. 展开更多
关键词 Plasma electrolytic oxidation Pulsed waveforms AZ31 Mg alloy Dipotassium titanium hexafluoride Corrosion resistance Wear resistance
下载PDF
The Use of SF<sub>6</sub>and GIS to Study Farfield Modeling of Ocean Outfall Plumes in Florida
7
作者 Frederick Bloetscher Fernando J. Pleitez +10 位作者 Thomas Romah Ahmed Albasri Chase Dickinson Husayn El Sharif Kevin Matthews Trung-Duong Nguyen Lucrece Riche Frank Youngman Thomas P. Carsey Jack Stamates John R. Proni 《Journal of Environmental Protection》 2014年第11期1037-1052,共16页
In June, 2004 and February, 2007, in field tracer studies were conducted on the Hollywood and South Central outfalls, using sulfur hexafluoride (SF6) as a tracer. The objective of these studies was to determine if the... In June, 2004 and February, 2007, in field tracer studies were conducted on the Hollywood and South Central outfalls, using sulfur hexafluoride (SF6) as a tracer. The objective of these studies was to determine if the tracer could be detected in the farfield at significant distance, and if so, could this data be used to construct a model of the farfield plume. Prior models for farfield plume movement do not appear to comport well with the conditions in southeast Florida. Extensive research was conducted in southeast Florida on 4 outfalls, which led to the development of nearfield dilution equations for same. However farfield modeling of outfall plumes was difficult to accomplish because the tracers used are not detectable for significant distances. The SF6 resolved that problem and as a result the Hollywood outfall was used to construct a model. Two methods were investigated for modeling the plume, 1) the Eureqa formulation method and 2) the Gamma-Curve method. The concentrations in the x-y plane were first found by using the Eureqa formulation to calculate the concentration at each grid point given its depth and the concentration of the centerline at the same latitude. The plume models were generated using MATLAB that matched with the results actually seen in the field. 展开更多
关键词 OCEAN OUTFALL Treated Sewage Effluent Disposal Farfield Modeling Sulfur hexafluoride
下载PDF
High Density Fluorine Negative-Ion Source Generated by Utilizing Magnetized SF<sub>6</sub>
8
作者 M. Abid Imtiaz Tetsu Mieno 《Journal of Modern Physics》 2014年第2期89-91,共3页
In a magnetized plasma column generated from an electronegative gas, negative-ions accumulate around the plasma column via radial diffusion. In this study, a dc discharge is applied in SF6 gas to produce a plasma colu... In a magnetized plasma column generated from an electronegative gas, negative-ions accumulate around the plasma column via radial diffusion. In this study, a dc discharge is applied in SF6 gas to produce a plasma column, and the radial density profile of negative-ions is measured by Langmuir probes using the modified Bohm criterion. The gas pressure and discharge current dependences of negative-ion density are also measured. It is found that the negative-ion density of 8.0 × 1017 m-3 is obtained around the plasma column at r = 1.0 cm when SF6 pressure is 0.13 Pa and discharge current is 0.50 A. The negative-ion density has radial gradient, and the electron density is much lower in this region. 展开更多
关键词 FLUORINE NEGATIVE-ION Ion Source String-Type PLASMA Radial Diffusion Langmuir Probe MAGNETIZED PLASMA Sulfur hexafluoride
下载PDF
Environment-friendly Insulating Gases for HVDC Gas-insulated Transmission Lines 被引量:1
9
作者 Geng Chen Youping Tu +6 位作者 Cong Wang Jue Wang Zhikang Yuan Guoming Ma Jian Wang Bo Qi Chuanyang Li 《CSEE Journal of Power and Energy Systems》 SCIE CSCD 2021年第3期510-529,共20页
Environment-friendly gas insulating mediums adapted to a DC gas-insulated transmission line(GIL)electric field condition is the key to the next generation of Environment-friendly HVDC GILs.In this paper,we review the ... Environment-friendly gas insulating mediums adapted to a DC gas-insulated transmission line(GIL)electric field condition is the key to the next generation of Environment-friendly HVDC GILs.In this paper,we review the literature on sulfur hexafluoride(SF6)alternatives including the scientific understanding,control,and implementation of gas-solid systems in this type of power transmission.First,the structure-activity relationship between the molecular structure and physico-chemical properties of Environment-friendly insulating gases is presented.Then,the search and prediction of important physicochemical properties of gases are summarized.Subsequently,in view of the potential of environmental friendly insulating gases,the swarm parameters of gas discharge and breakdown properties in a quasi-uniform field,inhomogeneous field,and at the gas-solid interface,that need to be taken into account with industrialized DC GILs are discussed.The latest research progress on insulation characteristics,especially the polarity effect in DC gas-solid insulation systems,the sensitivity to the electrode surface state,and the non-uniformity of the electric field,and the influence of metal particles and their variation with air pressure,is highlighted.In addition,the heat transfer characteristics of insulating gases,related to DC GIL transmission with a large current-carrying capacity and the influence of alternative gases on the heat transfer characteristics are described.Finally,aiming at solving the contradiction of low environmental impact,high dielectric strength and low liquefaction temperatures in the selection of alternative gases,an coordinated regulation model for Environment-friendly gases in DC GILs is established.Considerations for future work on this topic are also presented. 展开更多
关键词 Environmental friendly insulating gas gas-insulated transmission line high-voltage direct-current transmis-sion sulfur hexafluoride
原文传递
上一页 1 下一页 到第