The slip-sweep technique is one of the high-efficiency, high-fidelity, and environmental vibroseis seismic prospecting techniques which consists of a vibrator group sweeping without waiting for the previous group's s...The slip-sweep technique is one of the high-efficiency, high-fidelity, and environmental vibroseis seismic prospecting techniques which consists of a vibrator group sweeping without waiting for the previous group's sweep to terminate. The cycle time can be reduced drastically and hence the production efficiency can be increased significantly but harmonic distortion of one sweep will leak into the record of the other sweep. In this paper, we propose an anti-correlation method for removing harmonic distortion in vibroseis data. This method is based on decomposition of the ground force signal into fundamental and harmonic components. Then the corresponding anti-correlation operator can be computed to estimate the energy of each harmonic after correlating the vibroseis data with the corresponding harmonic component. Finally, the vibroseis harmonic noise to be removed can be obtained by subtracting the extracted harmonic noise from the traces of the previous group's sweep. The advantage of the proposed method is that it can process both uncorrelated and correlated vibroseis seismic data. Moreover, the algorithm is simple, stable, and computationally fast. Especially, the significant contribution of this method is a considerable reduction in the harmonic without any alteration of the desired signals. The method was tested on both synthetic and field data sets to validate the good harmonic noise suppression results.展开更多
A correlation-based digital background calibration algorithm for pipelined Analog-to- Digital Converters (ADCs) is presented in this paper. The merit of the calibration algorithm is that the main errors information, w...A correlation-based digital background calibration algorithm for pipelined Analog-to- Digital Converters (ADCs) is presented in this paper. The merit of the calibration algorithm is that the main errors information, which include the capacitor mismatches and residue amplifier distortion, are extracted integrally. A modified 1st pipelined stage is adopted to solve the signal overflow caused by the Pseudo-random Noise (PN) sequences. Behavioral simulation results verify the effectiveness of the algorithm. It improves the Signal-to-Noise-plus-Distortion Ratio (SNDR) and Spurious-Free-Dynamic-Range (SFDR) of the pipelined ADC from 41.8 dB to 78.3 dB and 55.6 dB to 98.6 dB, respectively, which is comparable to the prior arts.展开更多
Multi-level inverters(MLIs)have become popular in different applications such as industrial power control systems and distributed generations.There are different forms of MLIs.The cascaded MLIs(CMLIs)have some special...Multi-level inverters(MLIs)have become popular in different applications such as industrial power control systems and distributed generations.There are different forms of MLIs.The cascaded MLIs(CMLIs)have some special advantages among them such as more different output voltage levels using the same number of components and higher power quality.In this paper,a 27-level inverter switching algorithm considering total harmonic distortion(THD)minimization is investigated.Switching angles of the inverter switches are achieved by minimizing a THD-based objective function.In order to minimize the THD-based objective function,the hyper-spherical search(HSS)algorithm,as a novel optimization algorithm,is improved and the results of improved HSS(IHSS)are compared with HSS algorithm and other five evolutionary algorithms to show the advantages of IHSS algorithm.展开更多
This multilevel inverter methodology is the center of focus among researchers in recent era.It has been focused due to its advantages over existing topologies,drawbacks and improvement of power quality,Multi-level inv...This multilevel inverter methodology is the center of focus among researchers in recent era.It has been focused due to its advantages over existing topologies,drawbacks and improvement of power quality,Multi-level inverter has the ability to generate nearly sinusoidal waves.This sinusoidal wave can be further improved by increasing the level of output voltage or with the help of filter design,and this manuscript presents single-phase Multi cell Multi-Level Inverter(MLI).It has been considered for reducing component count to get a higher number of output voltage levels and lower Total harmonics distortion profile.It comprises with four symmetric DC input voltage and 10 IGBT switches to produces stepped output of 9 level,and when deploy asymmetric Dc voltage source the same circuit will produce 31 level output with some changes in firing scheme,moreover this circuit is the family of cascaded hybrid bridge inverter so this circuit covered advantage of CHB MLI,This circuit uses lower no.of switch as compared to existing conventional MLIs such as FC-MLI,CHB-MLI,NPC-MLI,This paper also provides one of most pertinent controls and modulation mechanisms for a MLI using a hybrid reference/carrier-oriented sinusoidal PWM mechanism.At last,simulated outcomes are to validate the performance of both architectures in MLI structure as well as verify the concept.展开更多
Background: Ultrasonic energy devices are utilized for transection, incision, and hemostasis in traditional open and laparoscopic procedures. The Harmonic HD 1000i Shears, designed to deliver a precise amount of therm...Background: Ultrasonic energy devices are utilized for transection, incision, and hemostasis in traditional open and laparoscopic procedures. The Harmonic HD 1000i Shears, designed to deliver a precise amount of thermal energy during tissue transection and vessel sealing, has been utilized in many specialties. This study aimed to confirm real-world safety and performance of the Harmonic device in two thoracoscopic procedures: lobectomy and segmentectomy. Methods: The primary endpoint of this retrospective, observational, single-arm study was rate of post-operative blood transfusions related to study device or procedure. Secondary endpoints included occurrence of intra- and post-operative adverse events (AEs) or complications device- or procedure-related, and rate of required additional hemostatic measures. Adults included those who underwent thoracoscopic lobectomy or segmentectomy where HD 1000i shears were used while excluding those where additional advanced energy devices were used. The study was conducted at Severance Hospital, Yonsei University Health System, South Korea from May 1, 2018, to November 30, 2020. Results: Subjects included n = 766 lobectomies (mean age 63.79, 52% male) and n = 215 segmentectomies (mean age 63.19, 54% male). Estimated blood loss was 50 mL (0 min, 3200 max) and 20 mL (0 min, 800 max), intraoperative transfusion rate 0.001% and 0%, intraoperative complication/AE rate 1% and 2%, and post-operative complication/AE rate 9% and 4% in the lobectomy and segmentectomy groups, respectively. Median operative times were 108 min. (35 min, 395 max) for lobectomies and 105 min. (32 min, 574 max) for segmentectomies. Conclusion: Given the low rate of blood loss and intra- and post-operative complication/AE rates, HD 1000i can be used confidently for thoracoscopic pulmonary resection in adults.展开更多
In recent day’s power distribution system is distress from acute power quality issues.In this work,for compensating Power Quality(PQ)disturbances a seven level cascaded H-bridge inverter is implemented in distributio...In recent day’s power distribution system is distress from acute power quality issues.In this work,for compensating Power Quality(PQ)disturbances a seven level cascaded H-bridge inverter is implemented in distribution static com-pensator which protects power quality problems in currents.Distribution Static Compensator(DSTATCOM)aid to enhances power factor and removes total har-monic distortion which is drawn from non-linear load.The D–Q reference theory based hysteresis current controller is employed to generate reference current for compensation of harmonics and reactive power,additionally Probabilistic Neural Network(PNN)classifier is used which easily separates exact harmonics.In the meantime fuzzy logic controller is also used to maintain capacitor DC-link poten-tial.When comparing to PI controller it decreases steady state time and reduces maximum peak overshoot.Cascaded H-bridge multilevel inverter converts direct current to Alternating current,through inductor opposite harmonics are injected in Power Control Centre reduces source current harmonics and reactive power.The implementation of CHBMLI in distribution STATic COMpensator simulation model is simulated by means of MATLAB.展开更多
The generation of photovoltaic(PV)solar energy is increasing continuously because it is renewable,unlimited,and clean energy.In the past,generation systems depended on non-renewable sources such as oil,coal,and gas.Th...The generation of photovoltaic(PV)solar energy is increasing continuously because it is renewable,unlimited,and clean energy.In the past,generation systems depended on non-renewable sources such as oil,coal,and gas.Therefore,this paper assesses the performance of a 51 kW PV solar power plant connected to a low-voltage grid to feed an administrative building in the 6th of October City,Egypt.The performance analysis of the considered grid-connected PV system is carried out using power system simulator for Engineering(PSS/E)software.Where the PSS/E program,monitors and uses the power analyzer that displays the parameters and measures some parameters such as current,voltage,total power,power factor,frequency,and current and voltage harmonics,the used inverter from the type of grid inverter for the considered system.The results conclude that when the maximum solar radiation is reached,the maximum current can be obtained from the solar panels,thus obtaining the maximum power and power factor.Decreasing total voltage harmonic distortion,a current harmonic distortion within permissible limits using active harmonic distortion because this type is fast in processing up to 300 microseconds.The connection between solar stations and the national grid makes the system more efficient.展开更多
基金supported by the Sinopec Service Company and China National Petroleum Corporation
文摘The slip-sweep technique is one of the high-efficiency, high-fidelity, and environmental vibroseis seismic prospecting techniques which consists of a vibrator group sweeping without waiting for the previous group's sweep to terminate. The cycle time can be reduced drastically and hence the production efficiency can be increased significantly but harmonic distortion of one sweep will leak into the record of the other sweep. In this paper, we propose an anti-correlation method for removing harmonic distortion in vibroseis data. This method is based on decomposition of the ground force signal into fundamental and harmonic components. Then the corresponding anti-correlation operator can be computed to estimate the energy of each harmonic after correlating the vibroseis data with the corresponding harmonic component. Finally, the vibroseis harmonic noise to be removed can be obtained by subtracting the extracted harmonic noise from the traces of the previous group's sweep. The advantage of the proposed method is that it can process both uncorrelated and correlated vibroseis seismic data. Moreover, the algorithm is simple, stable, and computationally fast. Especially, the significant contribution of this method is a considerable reduction in the harmonic without any alteration of the desired signals. The method was tested on both synthetic and field data sets to validate the good harmonic noise suppression results.
基金Supported by the Doctoral Program Foundation of Institutions of Higher Education of China (No.20120111120008)State Key Lab of ASIC & System(Fudan University) (No. 11KF001)Special Fund for Doctoral Program (Hefei University of Technology) (No.2011HGBZ0953)
文摘A correlation-based digital background calibration algorithm for pipelined Analog-to- Digital Converters (ADCs) is presented in this paper. The merit of the calibration algorithm is that the main errors information, which include the capacitor mismatches and residue amplifier distortion, are extracted integrally. A modified 1st pipelined stage is adopted to solve the signal overflow caused by the Pseudo-random Noise (PN) sequences. Behavioral simulation results verify the effectiveness of the algorithm. It improves the Signal-to-Noise-plus-Distortion Ratio (SNDR) and Spurious-Free-Dynamic-Range (SFDR) of the pipelined ADC from 41.8 dB to 78.3 dB and 55.6 dB to 98.6 dB, respectively, which is comparable to the prior arts.
文摘Multi-level inverters(MLIs)have become popular in different applications such as industrial power control systems and distributed generations.There are different forms of MLIs.The cascaded MLIs(CMLIs)have some special advantages among them such as more different output voltage levels using the same number of components and higher power quality.In this paper,a 27-level inverter switching algorithm considering total harmonic distortion(THD)minimization is investigated.Switching angles of the inverter switches are achieved by minimizing a THD-based objective function.In order to minimize the THD-based objective function,the hyper-spherical search(HSS)algorithm,as a novel optimization algorithm,is improved and the results of improved HSS(IHSS)are compared with HSS algorithm and other five evolutionary algorithms to show the advantages of IHSS algorithm.
文摘This multilevel inverter methodology is the center of focus among researchers in recent era.It has been focused due to its advantages over existing topologies,drawbacks and improvement of power quality,Multi-level inverter has the ability to generate nearly sinusoidal waves.This sinusoidal wave can be further improved by increasing the level of output voltage or with the help of filter design,and this manuscript presents single-phase Multi cell Multi-Level Inverter(MLI).It has been considered for reducing component count to get a higher number of output voltage levels and lower Total harmonics distortion profile.It comprises with four symmetric DC input voltage and 10 IGBT switches to produces stepped output of 9 level,and when deploy asymmetric Dc voltage source the same circuit will produce 31 level output with some changes in firing scheme,moreover this circuit is the family of cascaded hybrid bridge inverter so this circuit covered advantage of CHB MLI,This circuit uses lower no.of switch as compared to existing conventional MLIs such as FC-MLI,CHB-MLI,NPC-MLI,This paper also provides one of most pertinent controls and modulation mechanisms for a MLI using a hybrid reference/carrier-oriented sinusoidal PWM mechanism.At last,simulated outcomes are to validate the performance of both architectures in MLI structure as well as verify the concept.
文摘Background: Ultrasonic energy devices are utilized for transection, incision, and hemostasis in traditional open and laparoscopic procedures. The Harmonic HD 1000i Shears, designed to deliver a precise amount of thermal energy during tissue transection and vessel sealing, has been utilized in many specialties. This study aimed to confirm real-world safety and performance of the Harmonic device in two thoracoscopic procedures: lobectomy and segmentectomy. Methods: The primary endpoint of this retrospective, observational, single-arm study was rate of post-operative blood transfusions related to study device or procedure. Secondary endpoints included occurrence of intra- and post-operative adverse events (AEs) or complications device- or procedure-related, and rate of required additional hemostatic measures. Adults included those who underwent thoracoscopic lobectomy or segmentectomy where HD 1000i shears were used while excluding those where additional advanced energy devices were used. The study was conducted at Severance Hospital, Yonsei University Health System, South Korea from May 1, 2018, to November 30, 2020. Results: Subjects included n = 766 lobectomies (mean age 63.79, 52% male) and n = 215 segmentectomies (mean age 63.19, 54% male). Estimated blood loss was 50 mL (0 min, 3200 max) and 20 mL (0 min, 800 max), intraoperative transfusion rate 0.001% and 0%, intraoperative complication/AE rate 1% and 2%, and post-operative complication/AE rate 9% and 4% in the lobectomy and segmentectomy groups, respectively. Median operative times were 108 min. (35 min, 395 max) for lobectomies and 105 min. (32 min, 574 max) for segmentectomies. Conclusion: Given the low rate of blood loss and intra- and post-operative complication/AE rates, HD 1000i can be used confidently for thoracoscopic pulmonary resection in adults.
文摘In recent day’s power distribution system is distress from acute power quality issues.In this work,for compensating Power Quality(PQ)disturbances a seven level cascaded H-bridge inverter is implemented in distribution static com-pensator which protects power quality problems in currents.Distribution Static Compensator(DSTATCOM)aid to enhances power factor and removes total har-monic distortion which is drawn from non-linear load.The D–Q reference theory based hysteresis current controller is employed to generate reference current for compensation of harmonics and reactive power,additionally Probabilistic Neural Network(PNN)classifier is used which easily separates exact harmonics.In the meantime fuzzy logic controller is also used to maintain capacitor DC-link poten-tial.When comparing to PI controller it decreases steady state time and reduces maximum peak overshoot.Cascaded H-bridge multilevel inverter converts direct current to Alternating current,through inductor opposite harmonics are injected in Power Control Centre reduces source current harmonics and reactive power.The implementation of CHBMLI in distribution STATic COMpensator simulation model is simulated by means of MATLAB.
文摘The generation of photovoltaic(PV)solar energy is increasing continuously because it is renewable,unlimited,and clean energy.In the past,generation systems depended on non-renewable sources such as oil,coal,and gas.Therefore,this paper assesses the performance of a 51 kW PV solar power plant connected to a low-voltage grid to feed an administrative building in the 6th of October City,Egypt.The performance analysis of the considered grid-connected PV system is carried out using power system simulator for Engineering(PSS/E)software.Where the PSS/E program,monitors and uses the power analyzer that displays the parameters and measures some parameters such as current,voltage,total power,power factor,frequency,and current and voltage harmonics,the used inverter from the type of grid inverter for the considered system.The results conclude that when the maximum solar radiation is reached,the maximum current can be obtained from the solar panels,thus obtaining the maximum power and power factor.Decreasing total voltage harmonic distortion,a current harmonic distortion within permissible limits using active harmonic distortion because this type is fast in processing up to 300 microseconds.The connection between solar stations and the national grid makes the system more efficient.