Percutaneous Ventricular Restoration Therapy Using the Parachute Device in Chinese Patients with Ischemic Heart Failure: Three-Month Primary End-point Results of PARACHUTE China Study 被引量:18
1
作者 Yue-Jin Yang Yong Huo +6 位作者 Ya-Wei Xu Jian-An Wang Ya-Ling Han Jun-Bo Ge Rui-Yan Zhang Xiao-Yan Yan Run-Lin Gao 《Chinese Medical Journal》 SCIE CAS CSCD 2016年第17期2058-2062,共5页
Background: The primary cause of ischemic heart failure (HF) is myocardial infarction (MI) resulting in left ventricle (LV) wall motion abnormality secondary to ventricular remodeling. A prospective, nonrandomi... Background: The primary cause of ischemic heart failure (HF) is myocardial infarction (MI) resulting in left ventricle (LV) wall motion abnormality secondary to ventricular remodeling. A prospective, nonrandomized study conducted in China was designed to assess safety and efficacy of the percutaneous ventricular restoration therapy using Parachute device (CardioKinetix, lnc., CA, USA) in ischemic HF patients as a result of LV remodeling after anterior wall M1. Methods: Thirty-one patients with New York Heart Association (NYHA) Class I1, I11 ischemic HF, ejection traction between 15% and 40%, and dilated akinetic or dyskinetic anterior-apical wall without the need to be revascularized were enrolled from seven sites in China from October to December 2014. The Parachute device was implanted through femoral artery. All patients received low-dose aspirin and anticoagulation with warfarin tbr at least 12 months postdevice implantation. The primary end-point was the assessment of efficacy as measured by the reduction in LV end-systolic volume index (LVESVI) against baseline LVESVI at 3 months postdevice implantation, determined by the echocardiography and measured by echocardiography core laboratory. Quality of life was assessed using EQ-SD and visual analog scale (VAS). For quantitative data comparison, paired t-test (normality data) and signed-rank test (abnormality data) were used: application of signed-rank test was tbr the ranked data comparison. Results: A change in LVESVI as measured by echocardiography from the preimplant baseline to 3-month postdevice implantation revealed a statistically significant reduction from 77.5 ~ 20.0 ml/m-' to 53,1 ~ 17.0 ml/m-" (P 〈 0.0001 ), The trial met its primary end-point. Of the 31 patients, the procedural success was 96.8%. Overall, NYHA HF class assessment results showed an improvement of more than halfa class at 3 months (P 〈 0.001 ). Quality of life assessed by the VAS value increased 11.5 points (P 〈 0.01 ), demonstrating improvement at 3 months.Conclusion: The favorable outcomes observed in the high-risk patients provide reassuring safety and efficacy data to support adoption of this technology as a therapeutic option for ischemic HF patients. Trial Registration: ClinicalTrials.gov, NCT02240940; https:// clinicaltrials.gov/ct2/show/NCT02240940. 展开更多
关键词 lschemic heart Failure Left Ventricle Remodeling Percutaneous Ventricular Restoration Structural heart
原文传递
Effects of Qili Qiangxin capsule on lung structural remodeling in heart failure rats after myocardial infarction and its mechanism
2
作者 韩安帮 《China Medical Abstracts(Internal Medicine)》 2017年第1期6-,共1页
Objective To observe the effect of Qili Qiangxin Capsule(QQC)in improving lung structural remodeling on heart failure(HF)rats after myocardial infarction(MI)and to study its possible mechanism.Methods The proximal lef... Objective To observe the effect of Qili Qiangxin Capsule(QQC)in improving lung structural remodeling on heart failure(HF)rats after myocardial infarction(MI)and to study its possible mechanism.Methods The proximal left anterior descending branch of coronary artery was ligated using a terylene suture to establish 展开更多
关键词 LUNG Effects of Qili Qiangxin capsule on lung structural remodeling in heart failure rats after myocardial infarction and its mechanism