期刊文献+
共找到1,399篇文章
< 1 2 70 >
每页显示 20 50 100
The Differences of Interstitial Lung Diseases in High-Resolution Computerized Tomography and Pulmonary Function Test among Different Connective Tissue Diseases, and the Correlated Factors 被引量:1
1
作者 Zhen Jiang Wenyou Pan +1 位作者 Jinhui Tao Xiangpei Li 《Open Journal of Rheumatology and Autoimmune Diseases》 2018年第2期53-65,共13页
Objective. To study the difference of interstitial lung diseases (ILDs) in high-resolution computerized tomography and pulmonary function test among different connective tissue diseases (CTDs). Methods. 209 patients w... Objective. To study the difference of interstitial lung diseases (ILDs) in high-resolution computerized tomography and pulmonary function test among different connective tissue diseases (CTDs). Methods. 209 patients with different CTDs were recruited and underwent lung HRCT and PFT. Eerythrocyte sedimentation rate (ESR), C-reactive protein (CRP), serum ferritin (SF), anti-SSA, and so on were tested. Based on HRCT, a patient was classified into ILD group (CTD+ILD) or non-ILD group (CTD-ILD). HRCT, PFT, and laboratory markers were compared according to CTDs and CTD-associated ILDs. Results. The incidences of ILD were 79.6%, 82.0%, 89.7%, and 97.1% respectively for Rheumatoid arthritis (RA), primary Sjogren’s symptom (pSS), dermatomyositis/polymyositis (DM/PM), and systemic sclerosis (SSc) groups. RA and pSS patients exhibited more nodules, patching, ground-glass opacity, and cord shadow foci in HRCT, DM/PM and SSc patients exhibited more reticular opacity and honeycombing foci. RA and pSS patients exhibited more obstructive ventilatory disorder, small airway dysfunction and emphysema in PFT, and DM/PM and SSc patients exhibited more restrictive ventilatory disorder, mixed ventilatory disorder. ESR, CRP and SF were significantly higher in total CTD+ILD group than in total CTD-ILD group (P = 0.047, 0.006, 0.004, respectively), and higher in different CTD+ ILD groups than in comparable CTD-ILD groups (P = 0.049, 0.048, and 0.023, pSS+ILD, SSc+ILD and RA+ILD compared to pSS-ILD, SSc-ILD and RA-ILD, respectively for ESR, CRP, SF). The positive rate of anti-SSA was significantly higher in DM/PM+ILD group than in DM/PM-ILD group (P = 0.025). Conclusions. The manifestations and incidences of ILDs differ among different CTDs in HRCT and PFT, and inflammation and anti-SSA are positively correlated with ILDs in different CTDs, which provide important evidences for judging disease condition and prognosis. 展开更多
关键词 CONNECTIVE Tissue Diseases INTERSTITIAL lung Disease high-resolution computerized tomography PULMONARY Function Test Inflammation
下载PDF
Computerized tomography-guided therapeutic percutaneous puncture catheter drainage-combined with somatostatin for severe acute pancreatitis: An analysis of efficacy and safety 被引量:1
2
作者 Xue-Lan Zheng Wan-Ling Li +1 位作者 Yan-Ping Lin Ting-Long Huang 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第1期59-66,共8页
BACKGROUND Severe acute pancreatitis(SAP),a condition with rapid onset,critical condition and unsatisfactory prognosis,poses a certain threat to human health,warranting optimization of relevant treatment plans to impr... BACKGROUND Severe acute pancreatitis(SAP),a condition with rapid onset,critical condition and unsatisfactory prognosis,poses a certain threat to human health,warranting optimization of relevant treatment plans to improve treatment efficacy.AIM To evaluate the efficacy and safety of computerized tomography-guided the-rapeutic percutaneous puncture catheter drainage(CT-TPPCD)combined with somatostatin(SS)in the treatment of SAP.METHODS Forty-two SAP patients admitted to The Second Affiliated Hospital of Fujian Medical University from June 2020 to June 2023 were selected.On the basis of routine treatment,20 patients received SS therapy(control group)and 22 patients were given CT-TPPCD plus SS intervention(research group).The efficacy,safety(pancreatic fistula,intra-abdominal hemorrhage,sepsis,and organ dysfunction syndrome),abdominal bloating and pain relief time,bowel recovery time,hospital stay,inflammatory indicators(C-reactive protein,interleukin-6,and pro-calcitonin),and Acute Physiology and Chronic Health Evaluation(APACHE)II score of both groups were evaluated for comparison.RESULTS Compared with the control group,the research group had a markedly higher total effective rate,faster abdominal bloating and pain relief and bowel recovery,INTRODUCTION Pancreatitis,an inflammatory disease occurring in the pancreatic tissue,is classified as either acute or chronic and is associated with high morbidity and mortality,imposing a socioeconomic burden[1,2].The pathogenesis of this disease involves early protease activation,activation of nuclear factor kappa-B-related inflammatory reactions,and infiltration of immune cells[3].Severe acute pancreatitis(SAP)is a serious condition involving systemic injury and subsequent possible organ failure,accounting for 20%of all acute pancreatitis cases[4].SAP is also characterized by rapid onset,critical illness and unsatisfactory prognosis and is correlated with serious adverse events such as systemic inflammatory response syn-drome and acute lung injury,threatening the health of patients[5,6].Therefore,timely and effective therapeutic inter-ventions are of great significance for improving patient prognosis and ensuring therapeutic effects.Somatostatin(SS),a peptide hormone that can be secreted by endocrine cells and the central nervous system,is in-volved in the regulatory mechanism of glucagon and insulin synthesis in the pancreas[7].It has complex and pleiotropic effects on the gastrointestinal tract,which can inhibit the release of gastrointestinal hormones and negatively modulate the exocrine function of the stomach,pancreas and bile,while exerting a certain influence on the absorption of the di-gestive system[8,9].SS has shown certain clinical effectiveness when applied to SAP patients and can regulate the severity of SAP and immune inflammatory responses,and this regulation is related to its influence on leukocyte apoptosis and adhesion[10,11].Computerized tomography-guided therapeutic percutaneous puncture catheter drainage(CT-TPPCD)is a surgical procedure to collect lesion fluid and pus samples from necrotic lesions and perform puncture and drainage by means of CT image examination and precise positioning[12].In the research of Liu et al[13],CT-TPPCD applied to pa-tients undergoing pancreatic surgery contributes to not only good curative effects but also a low surgical risk.Baudin et al[14]also reported that CT-TPPCD has a clinical success rate of 64.6%in patients with acute infectious necrotizing pan-creatitis,with nonfatal surgery-related complications found in only two cases,suggesting that this procedure is clinically effective and safe in the treatment of the disease.In light of the limited studies on the efficacy and safety of SS plus CT-TPPCD in SAP treatment,this study performed a relevant analysis to improve clinical outcomes in SAP patients. 展开更多
关键词 computerized tomography guidance Therapeutic percutaneous puncture catheter drainage SOMATOSTATIN Severe acute pancreatitis Efficacy and safety
下载PDF
Study on sex differences and potential clinical value of threedimensional computerized tomography pelvimetry in rectal cancer patients
3
作者 Xiao-Cong Zhou Fei-Yue Ke +2 位作者 Gaurav Dhamija Hao Chen Qiang Wang 《World Journal of Gastrointestinal Oncology》 SCIE 2024年第3期773-786,共14页
BACKGROUND Laparoscopic rectal cancer radical surgery is a complex procedure affected by various factors.However,the existing literature lacks standardized parameters for the pelvic region and soft tissues,which hampe... BACKGROUND Laparoscopic rectal cancer radical surgery is a complex procedure affected by various factors.However,the existing literature lacks standardized parameters for the pelvic region and soft tissues,which hampers the establishment of consistent conclusions.AIM To comprehensively assess 16 pelvic and 7 soft tissue parameters through computerized tomography(CT)-based three-dimensional(3D)reconstruction,providing a strong theoretical basis to address challenges in laparoscopic rectal cancer radical surgery.METHODS We analyzed data from 218 patients who underwent radical laparoscopic surgery for rectal cancer,and utilized CT data for 3D pelvic reconstruction.Specific anatomical points were carefully marked and measured using advanced 3D modeling software.To analyze the pelvic and soft tissue parameters,we emp-loyed statistical methods including paired sample t-tests,Wilcoxon rank-sum tests,and correlation analysis.RESULTS The investigation highlighted significant sex disparities in 14 pelvic bone parameters and 3 soft tissue parameters.Males demonstrated larger measurements in pelvic depth and overall curvature,smaller measurements in pelvic width,a larger mesorectal fat area,and a larger anterior-posterior abdominal diameter.By contrast,females exhibited wider pelvises,shallower depth,smaller overall curvature,and an increased amount of subcutaneous fat tissue.However,there were no significant sex differences observed in certain parameters such as sacral curvature height,superior pubococcygeal diameter,rectal area,visceral fat area,waist circumference,and transverse abdominal diameter.CONCLUSION The reconstruction of 3D CT data enabled accurate pelvic measurements,revealing significant sex differences in both pelvic and soft tissue parameters.This study design offer potential in predicting surgical difficulties and creating personalized surgical plans for male rectal cancer patients with a potentially“difficult pelvis”,ultimately improving surgical outcomes.Further research and utilization of these parameters could lead to enhanced surgical methods and patient care in laparoscopic rectal cancer radical surgery. 展开更多
关键词 computerized tomography Rectal cancer Three-dimensional reconstruction PELVIMETRY Sex differences
下载PDF
Detection of tracheal branching with computerized tomography:The relationship between the angles and age-gender
4
作者 Şevket Kahraman Mesut Furkan Yazar +2 位作者 Hüseyin Aydemir Mecit Kantarci Sonay Aydin 《World Journal of Radiology》 2023年第4期118-126,共9页
BACKGROUND The data obtained on the anatomical knowledge of the tracheobronchial system can be used for diagnosis,treatment and interventional interventions in areas such as anesthesia,thoracic surgery,pulmonary physi... BACKGROUND The data obtained on the anatomical knowledge of the tracheobronchial system can be used for diagnosis,treatment and interventional interventions in areas such as anesthesia,thoracic surgery,pulmonary physiology.AIM To determine the tracheobronchial branching angles in pediatric and adult populations by using the multislice computed tomography(CT)and minimum intensity projection(MinIP)technique,which is a non-invasive method.METHODS Our study was carried out retrospectively.Patients who underwent contrast and non-contrast CT examination,whose anatomically and pathophysiologically good tracheobronchial system and lung parenchyma images were obtained,were included in the study.Measurements were made in the coronal plane of the lung parenchyma.In the coronal plane,right main bronchus-left main bronchus angle,right upper lobe bronchus-intermedius bronchus angle,right middle lobe bronchus-right lower lobe bronchus angle,left upper lobe bronchus-left lower lobe bronchus angle were measured.RESULTS The study population consisted of 1511 patients,753 pediatric(mean age:13.4±4.3;range:1-18 years)and 758 adults(mean age:54.3±17.3;range:19-94 years).In our study,tracheal bifurcation angle was found to be 73.3°±13.7°(59.6°-87°)in the whole population.In the pediatric group,the right-left main coronal level was found to be higher in boys compared to girls(74.6°±12.9°vs 71.2°±13.9°,P=0.001).In the adult group,the right-left main coronal level was found to be lower in males compared to females(71.9°±12.9°vs 75.8°±14.7°,P<0.001).CONCLUSIONS Our study,with the number of 1511 patients,is the first study in the literature with the largest number of patient populations including pediatric and adult demographic data,measuring the angle values of the tracheobronchial system using multislice CT and MinIP technique.Study data will not only be a guide during invasive procedures,but it can also guide studies to be done with imaging methods. 展开更多
关键词 Tracheobronchial branching angles Subcarinal angle Multislice computerized tomography Minimum intensity projection technique
下载PDF
Positron emission tomography/computerized tomography in the evaluation of primary non-Hodgkin's lymphoma of prostate 被引量:4
5
作者 Bo Pan Jian-Kui Han +1 位作者 Shi-Cun Wang Ao Xu 《World Journal of Gastroenterology》 SCIE CAS 2013年第39期6699-6702,共4页
Primary malignant lymphoma of the prostate is exceedingly rare.Here we report a case of a 65-year-old man who presented with increased urinary frequency,urinary urgency,and urinary incontinence for two years.Benign pr... Primary malignant lymphoma of the prostate is exceedingly rare.Here we report a case of a 65-year-old man who presented with increased urinary frequency,urinary urgency,and urinary incontinence for two years.Benign prostatic hypertrophy was suspected at primary impression.Ultrasound revealed a hypoechoic lesion of the prostate.The total serum prostate-specific antigen was within normal range.Positron emission tomography/computerized tomography(PET/CT)showed a hypermetabolic prostatic lesion.Prostate biopsy was consistent with a non-germinal center diffuse large B cell lymphoma.There was complete remission of the prostatic lesion following six cycles of chemotherapy as shown on the second PET/CT imaging.18F-fluoro-deoxy glucose PET/CT is not only a complement to conventional imaging,but also plays a significant role in the diagnosis and evaluation of treatment response of prostatic lymphoma. 展开更多
关键词 Fluoro-Deoxy-Glucose Positron emission tomography/computerized tomography Non-Hodgkin’s LYMPHOMA PROSTATIC LYMPHOMA EVALUATION
下载PDF
Use of high-resolution X-ray computed tomography and 3D image analysis to quantify mineral dissemination and pore space in oxide copper ore particles 被引量:8
6
作者 Bao-hua Yang Ai-xiang Wu +2 位作者 Guillermo A.Narsilio Xiu-xiu Miao Shu-yue Wu 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2017年第9期965-973,共9页
Mineral dissemination and pore space distribution in ore particles are important features that influence heap leaching performance. To quantify the mineral dissemination and pore space distribution of an ore particle,... Mineral dissemination and pore space distribution in ore particles are important features that influence heap leaching performance. To quantify the mineral dissemination and pore space distribution of an ore particle, a cylindrical copper oxide ore sample (I center dot 4.6 mm x 5.6 mm) was scanned using high-resolution X-ray computed tomography (HRXCT), a nondestructive imaging technology, at a spatial resolution of 4.85 mu m. Combined with three-dimensional (3D) image analysis techniques, the main mineral phases and pore space were segmented and the volume fraction of each phase was calculated. In addition, the mass fraction of each mineral phase was estimated and the result was validated with that obtained using traditional techniques. Furthermore, the pore phase features, including the pore size distribution, pore surface area, pore fractal dimension, pore centerline, and the pore connectivity, were investigated quantitatively. The pore space analysis results indicate that the pore size distribution closely fits a log-normal distribution and that the pore space morphology is complicated, with a large surface area and low connectivity. This study demonstrates that the combination of HRXCT and 3D image analysis is an effective tool for acquiring 3D mineralogical and pore structural data. 展开更多
关键词 high-resolution X-ray computed tomography 3D image analysis ore particles mineral dissemination pore space
下载PDF
Application of Proton Magnetic Resonance Spectroscopy and Computerized Tomography in the Diagnosis and Treatment of Nonalcoholic Fatty Liver Disease 被引量:4
7
作者 王南 董慧 +1 位作者 魏世超 陆付耳 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2008年第3期295-298,共4页
In order to investigate the application of proton magnetic resonance spectroscopy (ill-MRS) and computerized tomography (CT) in the quantitative diagnosis of nonalcoholic fatty liver disease (NAFLD) and evaluati... In order to investigate the application of proton magnetic resonance spectroscopy (ill-MRS) and computerized tomography (CT) in the quantitative diagnosis of nonalcoholic fatty liver disease (NAFLD) and evaluation of therapeutic effects, 22 patients with NAFLD were selected according to the Chinese Medical Association's (CMA) standard of the NAFLD in comparison with 20 healthy volunteers (as control group). Blood samples for biochemistry were collected. The severity of hepatosteatosis was evaluated by ^1H-MRS scan and CT scan of liver. The intrahepatic content of lipid (IHCL) and CT value ratio of liver to spleen were calculated. The patients in NAFLD group were treated with Ganzhixiao Capsule for 8 weeks. The changes in IHCL and CT value ratio of liver to spleen were observed before and after treatment. In NAFLD group serum ALT, TG, IHCL calculated by ^1HMRS were increased and CT value ratio of liver to spleen decreased significantly as compared with control group. After treatment for 8 weeks serum ALT, TG, IHCL were decreased significantly, while CT value ratio of liver to spleen increased significantly in NAFLD group. It was suggested that IHCL could be measured precisely by ^1HMRS. NAFLD was treated effectively by Ganzhixiao capsule. 展开更多
关键词 proton magnetic resonance spectroscopy computerized tomography nonalcoholic fatty liver disease
下载PDF
Pore structure of ore granular media by computerized tomography image processing 被引量:6
8
作者 吴爱祥 杨保华 +1 位作者 习泳 江怀春 《Journal of Central South University of Technology》 EI 2007年第2期220-224,共5页
The pore structure images of ore particles located at different heights of leaching column were scanned with X-ray computerized tomography (CT) scanner, the porosity and pore size distribution were calculated and the ... The pore structure images of ore particles located at different heights of leaching column were scanned with X-ray computerized tomography (CT) scanner, the porosity and pore size distribution were calculated and the geometrical shape and connectivity of pores were analyzed based on image process method, and the three dimensional reconstruction of pore structure images was realized. The results show that the porosity of ore particles bed in leaching column is 42.92%, 41.72%, 39.34% at top, middle and bottom zone, respectively. Obviously it has spatial variability and decreases appreciably along the height of the column. The overall average porosity obtained by image processing is 41.33% while the porosity gotten from general measurement method in laboratory is 42.77% showing the results of both methods are consistent well. The pore structure of ore granular media is characterized as a dynamical space network composed of interconnected pore bodies and pore throats. The ratio of throats with equivalent diameter less than 1.91 mm to the total pores is 29.31%, and that of the large pores with equivalent diameter more than 5.73 mm is 2.90%. 展开更多
关键词 ore granular media pore structure X-ray computerized tomography image processing
下载PDF
Effects of Irregular Respiratory Motion on the Positioning Accuracy of Moving Target with Free Breathing Cone-Beam Computerized Tomography 被引量:1
9
作者 Xiang Li Tianfang Li +9 位作者 Ellen Yorke Gig Mageras Xiaoli Tang Maria Chan Weijun Xiong Marsha Reyngold Richard Gewanter Abraham Wu John Cuaron Margie Hunt 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2018年第2期173-183,共11页
For positioning a moving target, a maximum intensity projection (MIP) or average intensity projection (AIP) image derived from 4DCT is often used as the reference image which is matched to free breathing cone-beam CT ... For positioning a moving target, a maximum intensity projection (MIP) or average intensity projection (AIP) image derived from 4DCT is often used as the reference image which is matched to free breathing cone-beam CT (FBCBCT) before treatment. This method can be highly accurate if the respiratory motion of the patient is stable. However, a patient’s breathing pattern is often irregular. The purpose of this study is to investigate the effects of irregular respiration on positioning accuracy for a moving target aligned with FBCBCT. Nine patients’ respiratory motion curves were selected to drive a Quasar motion phantom with one embedded cubic and two spherical targets. A 4DCT of the phantom was acquired on a CT scanner (Philips Brilliance 16) equipped with a Varian RPM system. The phase binned 4DCT images and the corresponding MIP and AIP images were transferred into Eclipse for analysis. FBCBCTs of the phantom driven by the same respiratory curves were also acquired on a Varian TrueBeam and fused such that both CBCT and MIP/AIP images share the same target zero positions. The sphere and cube volumes and centroid differences (alignment error) determined by MIP, AIP and FBCBCT images were calculated, respectively. Compared to the volume determined by MIP, the volumes of the cube, large sphere, and small sphere in AIP and FBCBCT images were smaller. The alignment errors for the cube, large sphere and small sphere with center to center matches between MIP and FBCBCT were 2.5 ± 1.8 mm, 2.4 ± 2.1 mm, and 3.8 ± 2.8 mm, and the alignment errors between AIP and FBCBCT were 0.5 ± 1.1 mm, 0.3 ± 0.8 mm, and 1.8 ± 2.0 mm, respectively. AIP images appear to be superior reference images to MIP images. However, irregular respiratory pattern could compromise the positioning accuracy, especially for smaller targets. 展开更多
关键词 CONE Beam computerized tomography RESPIRATORY Motion Effect
下载PDF
Comments on the article about correlation between computerized tomography and surgery in acute pancreatitis 被引量:1
10
作者 Enver Zerem Goran Imamovi +1 位作者 Zoran Mavija Bahrija Harai 《World Journal of Gastroenterology》 SCIE CAS CSCD 2011年第3期407-408,共2页
We read with great interest the article by Vege et al published in issue 34 of World J Gastroenterol 2010. The article evaluates the ability of contrast-enhanced computerized tomography (CECT) to characterize the natu... We read with great interest the article by Vege et al published in issue 34 of World J Gastroenterol 2010. The article evaluates the ability of contrast-enhanced computerized tomography (CECT) to characterize the nature of peripancreatic collections found at surgery. The results of their study indicate that most of the peripancreatic collections seen on CECT in patients with severe acute pancreatitis who require operative intervention contain necrotic tissue and CECT has a limited role in differentiating various types of collections. However, there are some points that need to be addressed, including data about the stage of acute pancreatitis in which CECT was done and the time span between CECT examination and surgery. 展开更多
关键词 Acute pancreatitis Pancreatic necrosis Peripancreatic fluid collection Contrast-enhanced computerized tomography SURGERY
下载PDF
Screening for lung cancer with chest computerized tomography: Is it cost efficient?
11
作者 Tomasz Jaroslaw Szczesny Malgorzata Kanarkiewicz Janusz Kowalewski 《World Journal of Respirology》 2015年第2期160-165,共6页
Despite lung cancer(LC) screening by low-dose computerized tomography(LDCT) gaining many proponents worldwide, for many years it was not recognized as a life-prolonging and cost-effective procedure, until recently. Pr... Despite lung cancer(LC) screening by low-dose computerized tomography(LDCT) gaining many proponents worldwide, for many years it was not recognized as a life-prolonging and cost-effective procedure, until recently. Prospective observational studies had not been able to prove that this screening prolongs survival, but they helped to specify the inclusion and exclusion criteria. Long-awaited results of a prospective, randomized trial finally provided the evidence that LC screening with LDCT can prolong survival of the screened population. Several costeffectiveness analyses were performed to justify mass introduction of this screening. Results of these analyses are equivocal, although conclusions highly depend upon inclusion and exclusion criteria, methods of analysis and prices of medical procedures which differ between countries as well as the incidence of other pulmonary nodules, especially tuberculosis. Therefore, costeffectiveness analysis should be performed separately for every country. Cost-effectiveness depends especially upon the rate of false-positive results and the rate of unnecessary diagnostic, screening and treatment procedures. To ensure high cost-effectiveness, LC screening should be performed in accordance with screening protocol, in dedicated screening centers equipped with nodule volume change analysis, or as a prospective non-randomized trial, to ensure compliance with the inclusion and exclusion criteria. To ensure high cost-effectiveness of LC screening, future research should concentrate on determination of highrisk groups and further specifying the inclusion and exclusion criteria. 展开更多
关键词 Lung cancer Non-small cell lung cancers SCREENING COST-EFFECTIVENESS computerized tomography Low-dose computerized tomography
下载PDF
The possible value of ~18F-FDG positron emission tomography/computerized tomography imaging in detection of atherosclerotic plaque
12
作者 Jianwei Yuan Yanlin Feng +1 位作者 Lingxiao Fan Xiaohong He 《Journal of Nanjing Medical University》 2008年第1期61-65,共5页
Objective:To evaluate the clinical value with positron emission tomography/computerized tomography(PET/CT) imaging for the detection of vulnerable plaque in atherosclerotic lesions. Methods:Sixty people with a age... Objective:To evaluate the clinical value with positron emission tomography/computerized tomography(PET/CT) imaging for the detection of vulnerable plaque in atherosclerotic lesions. Methods:Sixty people with a age of over 60[mean age (69.2 ± 7.1)years] underwent three dimension(3D) whole-body fluorine-18-2-fluoro-2-deoxy-D-glucose(^18F-FDG) PET/CT imaging and were evaluated retrospectively, including 6 cases assessed as normal and 54 cases with active atherosclerotic plaque. Fifty-four cases with SUVs and CT values in the aortic wall of high-FDG-uptake were measured retrospectively. These high-FDG-uptake cases in the aortic wall were divided into three groups according their CT value. Cases in group 1 had high uptake in atherosclerotic lesions of the aortic wall with CT value of less than 60 Hu(soft plaque). Cases in group 2 had high uptake with CT value between 60-100 Hu (intermediate plaque), Cases in group 3 had high uptake with CT value more than 100 Hu(calcified plaque), Group 4 was normal. Results: In group 1, there were 42 high-FDG-uptake sites (average SUV 1.553 ± 0.486). In group 2, there were 30 high-FDG-uptake sites(average SUV 1.393 ± 0.296). In group 3, there were 36 high-FDG-uptake sites(average SUV 1.354 ± 0.189). In group 4, there were 33 normal-FDG-uptake sites (average SUV was 1.102 ± 0.141), The SUVs showed significant difference among the four groups(F = 678.909, P = 0.000). There were also significant difference found between the normal-FDG-uptake group and the high-FDG-uptake groups(P = 0.000, 0.000, 0.001, respectively). Conclusion:Different degrees of ^18F-FDG uptake in active large atherosclerotic plaque were shown in different stages of atherosclerotic plaque formation. The soft plaque had the highest FDG uptake in this study. This suggested that ^18F- FDG PET/CT imaging may be of great potential value in early diagnosis and monitoring of vulnerable soft plaque in atherosclerotic lesions. 展开更多
关键词 fluorine-18-2-fluoro-2-deoxy-D-glucose positron-emission tomography computerized tomography ATHEROSCLEROSIS vulnerable plaque
下载PDF
Multi-slice computerized tomography critical role in transcatheter aortic valve implantation plan: Review of current literature
13
作者 Edward Koifman Ashraf Hamdan 《World Journal of Hypertension》 2015年第3期107-114,共8页
Transcatheter aortic valve implantation(TAVI) has been shown in improve outcome of severe aortic stenosis(AS) patients, deemed surgical high-risk or inoperable, and has grown popular in the past decade. The procedure ... Transcatheter aortic valve implantation(TAVI) has been shown in improve outcome of severe aortic stenosis(AS) patients, deemed surgical high-risk or inoperable, and has grown popular in the past decade. The procedure requires accurate prior planning, and demands an integration of a "Heart Team" consisted from cardiac surgeons, interventional cardiologists, and imaging experts. The role of cardiac imaging and especially multi-slice computerized tomography(MSCT) has been a mainstay of pre-evaluation of severe AS patients that allows to accurately depict and size the cardiac and vascular structures, and has become the primary tool for procedural planning. This article is aimed to evaluate current uses of MSCT in severe AS patients undergoing TAVI, delineate the various measurements derived from this modality and review current literature regarding it's advantages over other techniques. 展开更多
关键词 TRANSCATHETER AORTIC valve implantation Multi-slice computerized tomography AORTIC ANNULAR sizing Vascular access
下载PDF
Validations of new cut-offs for surgical drains management and use of computerized tomography scan after pancreatoduodenectomy:The DALCUT trial
14
作者 Damiano Caputo Alessandro Coppola +5 位作者 Vincenzo La Vaccara Roberto Passa Ludovico Carbone Massimo Ciccozzi Silvia Angeletti Roberto Coppola 《World Journal of Clinical Cases》 SCIE 2022年第15期4836-4842,共7页
BACKGROUND Postoperative pancreatic fistula(POPF)is the most fearful complication after pancreatic surgery and can lead to severe postoperative complications such as surgical site infections,sepsis and bleeding.A prev... BACKGROUND Postoperative pancreatic fistula(POPF)is the most fearful complication after pancreatic surgery and can lead to severe postoperative complications such as surgical site infections,sepsis and bleeding.A previous study which identified cut-offs of drains amylase levels(DALs)determined on postoperative day(POD)1 and POD3,was able to significantly predict POPF,abdominal collections and biliary fistulas,when related to specific findings detected at the abdominal computerized tomography(CT)scan routinely performed on POD3.AIM To validate the cut-offs of DALs in POD1 and POD3,established during the previous study,to assess the risk of clinically relevant POPF and confirm the usefulness of abdominal CT scan on POD3 in patients at increased risk of abdominal collection.METHODS The DALCUT trial is an interventional prospective study.All patients who will undergo pancreatoduodenectomy(PD)for periampullary neoplasms will be considered eligible.All patients will receive clinical staging and,if eligible for surgery,will undergo routine preoperative evaluation.After the PD,daily DALs will be evaluated from POD1.Drains removal and possible requirement of abdominal CT scans in POD3 will be managed on the basis of the outcome of DALs in the first three postoperative days.RESULTS This prospective study could validate the role of DALs in the management of surgical drains and in assessing the risk or relevant complications after PD.Drains could be removed in POD3 in case of POD1 DALs<666 U/L and POD3 DALs<207 U/L.In case of POD3 DALs≥252,abdominal CT scan will be performed in POD3 to identify abdominal collections≥5 cm.In this latter category of patients,drains could be maintained beyond POD3.CONCLUSION The results of this trial will contribute to a better knowledge of POPF and management of surgical drains. 展开更多
关键词 Pancreatic surgery Drains amylase Pancreatic fistula Postoperative complications computerized tomography scan
下载PDF
The Spleen and Sickle Cell Anemia: A Contrast Enhanced Computerized Tomography Based Study
15
作者 Malaz Mohammed Ali Omer Ahmed Caroline Edward Ayad 《Open Journal of Radiology》 2016年第3期168-180,共13页
The spleen is one of the most frequently affected organs in sickle cell anemia (SCA). This study aims to characterize the spleen in sickle cell anemia patients using contrast enhanced computerized tomography scanning ... The spleen is one of the most frequently affected organs in sickle cell anemia (SCA). This study aims to characterize the spleen in sickle cell anemia patients using contrast enhanced computerized tomography scanning (CECT). 67 patients with SCA from different Saudi Arabian areas were enrolled;ages are ranged from 10 months to 28 years old. The spleen was assessed with CT for abdominal pain and/or unexplained fever. The evaluation was done at different contrast enhancement scanning phases. The study showed that the least number of affected patients was from Eastern Saudi Arabia (1.5%) followed by Asseer (16.4%) then Gazan representing 82.1%. The most common type of SCA affected the Saudi children is Hemoglobin SS Disease (Hb SS) constituting 41 (61.2%). The spleen size, lymph nodes size, spleen Hounsfield (HU), splenic vein diameter and the correlation with the associated findings were evaluated for all of the patients. In children affected with SCA: 26 (38.8%) have splenomegaly, 18 (26.9%) have atrophied spleen and 2 (3.0%) are with very small tissue like structure. Lesions found in the spleen were abscess, infarction, cyst, and calcifications. At the spleen hilum region;dilated splenic vein, presence of multiple collaterals, and thrombus were also been detected. Significantly correlations were noticed between lesions type, child age, enlargement of spleen and splenic lymph nodes at P ≤ 0.033, P ≤ 0.010 and P ≤ 0.012 respectively and showed an evidence that the reduction of the HU and advanced age have significant relation with changing of the spleen size at P ≤ 0.004 and P ≤ 0.000 respectively. Spleen lesions’ enhancement pattern is well emerged in both venous and delay phase and it was significantly related with the scanning phase at P ≤ 0.000 and with different types of SCA at P ≤ 0.037, and P ≤ 0.055 in venous and delay phase in respectively. CECT offers a number of morphological criteria that can be applied to differentiate hypodense lesions of the spleen in SCA. CT characterization criteria of hypodense splenic lesions are acknowledged to aid interpretation during evaluation of abdominal CT images of the spleen in symptomatic patients with sickle cell anemia. 展开更多
关键词 SPLEEN Sickle Cell Disease computerized tomography
下载PDF
Diagnostic Evaluation of Pulmonary Embolism: A Computerized Tomography Based Study
16
作者 Salah Eldein Hassan Aloub Caroline Edward Ayad 《Open Journal of Radiology》 2016年第3期157-167,共11页
Pulmonary embolism (PE) is potentially life threatening condition which requires adequate diagnosis. Since computerized tomography pulmonary angiography (CTPA) described the presence of a clot subjectively, an objecti... Pulmonary embolism (PE) is potentially life threatening condition which requires adequate diagnosis. Since computerized tomography pulmonary angiography (CTPA) described the presence of a clot subjectively, an objective and quantification method to characterize plural parenchymal abnormality, pulmonary vessels and heart is needed (in order to diagnose PE). This study was directed to investigate whether the presence of plural parenchymal findings correlates with the PE and as well, it was designed to answer two basic questions based on CTPA findings done for clinical suspicion of PE: firstly, what are the plural parenchymal abnormalities associated with PE;secondly, correlation of PE with the presence of heart changes and pulmonary vessels measurements. CTPA scans were acquired for 55 patients suspected of having PE and another 50 subjects who were considered as control. The clinical signs and pleuroparenchymal abnormalities, pulmonary artery tree measurements, right ventricle and atrium diameters, Inter ventricular septum width as well as the myocardium thickening were characterized and correlated with PE. The results showed that the PE patients group has more dilated measurements than the normal control subjects. The right ventricle diameter changes were found to be significantly related to the presence of PE at p ≤ 0.001. Significant changes at p ≤ 0.005 were also noticed in the pulmonary trunk diameter as well as the right and left main pulmonary arteries with no significant changes detected in the distal portion of both pulmonary arteries diameters. The common complaints from PE patients were chest pain, shortness of breathing, lower limb swelling, tachycardia and syncope. Consolidation, ground glass opacifications, mosaic, right ventricle morphological changes and pleural effusion were present in the majority of patients undergoing CTPA for the clinical suspicion of PE. CTPA is considered as the diagnostic modality of choice in characterization of pulmonary vessels, atrium and ventricle changes as well as pleura parenchymal abnormalities in patients with or without PE. 展开更多
关键词 Pulmonary Embolism computerized tomography Pulmonary Angiography Pleuroparenchymal Abnormalities
下载PDF
High-resolution crustal velocity imaging using ambient noise recordings from a high-density seismic array:An example from the Shangrao section of the Xinjiang basin,China 被引量:9
17
作者 Gaochun Wang Xiaobo Tian +2 位作者 Lianglei Guo Jiayong Yan Qingtian Lyu 《Earthquake Science》 CSCD 2018年第5期242-251,共10页
A profile of shallow crustal velocity structure(1–2 km) may greatly enhance interpretation of the sedimentary environment and shallow tectonic deformation.Recent advances in surface wave tomography, using ambient noi... A profile of shallow crustal velocity structure(1–2 km) may greatly enhance interpretation of the sedimentary environment and shallow tectonic deformation.Recent advances in surface wave tomography, using ambient noise data recorded with high-density seismic arrays, have improved the understanding of regional crustal structure. As the interest in detailed shallow crustal structure imaging has increased, dense seismic array methods have become increasingly efficient. This study used a high-density seismic array deployed in the Xinjiang basin in southeastern China, to record seismic data, which was then processed with the ambient noise tomography method. The high-density seismic array contained 203 short-period seismometers, spaced at short intervals(~ 400 m). The array collected continuous records of ambient noise for 32 days. Data preprocessing,cross correlation calculation, and Rayleigh surface wave phase-velocity dispersion curve extraction, yielded more than 16,000 Rayleigh surface wave phase-velocity dispersion curves, which were then analyzed using the direct-inversion method. Checkerboard tests indicate that the shear wave velocity is recovered in the study area, at depths of 0–1.4 km,with a lateral image resolution of ~ 400 m. Model test results show that the seismic array effectively images a 50 m thick slab at a depth of 0–300 m, a 150 m thick anomalous body at a depth of 300–600 m, and a 400 m thick anomalous body at a depth of 0.6–1.4 km. The shear wave velocity profile reveals features very similar to those detected by a deep seismic reflection profile across the study area. This demonstrates that analysis of shallow crustal velocity structure provides high-resolution imaging of crustal features.Thus, ambient noise tomography with a high-density seismic array may play an important role in imaging shallow crustal structure. 展开更多
关键词 high-density seismic array ambient noise tomography shallow crustal structure high-resolution
下载PDF
The Clinical Application of Computerized Three-Dimensional Mimic Operation for Maxillofacial Bone Tumor 被引量:2
18
作者 陶学金 殷孝蓉 +1 位作者 朱芳 陈卫民 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 1999年第4期328-330,共3页
Facial bone, as the frame to support maxillofacial region and with several sinuses and cavities, is structurally complicated and the maxillofacial tumors,benign or malignant, in this region usually grows into the deep... Facial bone, as the frame to support maxillofacial region and with several sinuses and cavities, is structurally complicated and the maxillofacial tumors,benign or malignant, in this region usually grows into the deep tissues, sinus-cav-ities and orbit and destroys the bone. In this study, the maxillofacial tumors were subjected to a mimic operation on a computer following CT scanning and 3-dimen-sional reconstruction. The data similar to those of real operation were obtained,which could be used for developing operative plans. As compared with data on the basis of conditions in the real operation, computerized mimic operation reflected the real conditions during operation. Computerized mimic operation is valuable for the preoperative planning and the prediction of probable intraoperative events. 展开更多
关键词 maxillofacia tumor computerized mimic operation computed tomography
下载PDF
Virtual Anatomy: The Dissecting Theatre of the Future—Implementation of Cinematic Rendering in a Large 8 K High-Resolution Projection Environment 被引量:1
19
作者 Franz A. Fellner Klaus Engel Christoph Kremer 《Journal of Biomedical Science and Engineering》 2017年第8期367-375,共9页
Modern computer techniques have been in use for several years to generate three-dimensional visualizations of human anatomy. Very good 3-D computer models of the human body are now available and used routinely in anat... Modern computer techniques have been in use for several years to generate three-dimensional visualizations of human anatomy. Very good 3-D computer models of the human body are now available and used routinely in anatomy instruction. These techniques are subsumed under the heading “virtual anatomy” to distinguish them from the conventional study of anatomy entailing cadavers and anatomy textbooks. Moreover, other imaging procedures (X-ray, angiography, CT and MR) are also used in virtual anatomy instruction. A recently introduced three-dimensional post-processing technique named Cinematic Rendering now makes it possible to use the output of routine CT and MR examinations as the basis for highly photo-realistic 3-D depictions of human anatomy. We have installed Cinematic Rendering (enabled for stereoscopy) in a high-definition 8K 3-D projection space that accommodates an audience of 150. The space’s projection surface measures 16 × 9 meters;images can be projected on both the front wall and the floor. A game controller can be used to operate Cinematic Rendering software so that it can generate interactive real-time depictions of human anatomy on the basis of CT and MR data sets. This prototype installation was implemented without technical problems;in day-to-day, real-world use over a period of 22 months, there were no impairments of service due to software crashes or other technical problems. We are already employing this installation routinely for educational offerings open to the public, courses for students in the health professions, and (continuing) professional education units for medical interns, residents and specialists—in, so to speak, the dissecting theater of the future. 展开更多
关键词 Virtual Anatomy Education CINEMATIC RENDERING (CR) Volume RENDERING (VR) high-resolution 3D Display COMPUTED tomography (CT) Magnetic Resonance (MR)
下载PDF
基于体质量指数调节管电流个性化成人胸部低剂量CT扫描方案的应用研究
20
作者 黄远彬 韦波 +2 位作者 赵贞翔 龙昔珍 梁静 《临床医药实践》 2024年第9期682-685,共4页
目的:探讨基于体质量指数(BMI)调节管电流个性化成人胸部低剂量CT扫描方案的应用效果。方法:选取2023年1月—2023年12月成人胸部CT检查患者160例,根据随机数字表法分为常规剂量组和低剂量组,每组80例。记录两组患者的性别、年龄,测量患... 目的:探讨基于体质量指数(BMI)调节管电流个性化成人胸部低剂量CT扫描方案的应用效果。方法:选取2023年1月—2023年12月成人胸部CT检查患者160例,根据随机数字表法分为常规剂量组和低剂量组,每组80例。记录两组患者的性别、年龄,测量患者身高、体质量并计算BMI。常规剂量组设置管电压110 kV、固定管电流150 mA。低剂量组设置管电压110 kV,根据患者BMI设置管电流(高BMI组:BMI>24 kg/m^(2),管电流50 mA;中BMI组:19 kg/m^(2)≤BMI≤24 kg/m^(2),管电流40 mA;低BMI组:BMI<19 kg/m^(2),管电流30 mA),由2名放射科中级职称以上医师负责对胸部CT图像质量进行评价。采用统计学分析软件对患者一般资料、图像质量评价结果、辐射剂量数据进行统计学分析。结果:两组患者的性别、年龄、体质量、身高、BMI比较,差异均无统计学意义(P>0.05)。低剂量组图像主观评价5分占比低于常规剂量组,3分占比高于常规剂量组,差异有统计学意义(P<0.05);低剂量组图像主观评价4分占比与常规剂量相近,差异无统计学意义(P>0.05)。低剂量组信噪比(SNR)、噪声比(CNR)均高于常规剂量组,差异有统计学意义(P<0.05)。低剂量组虽然显著降低管电流,增加图像SNR和CNR,但低剂量组患者主观图像质量评分在3分以上,图像质量能满足疾病诊断要求。低剂量组患者的CT剂量指数(CT DIvo)、剂量长度乘积(DLP)、有效剂量(ED)均低于常规剂量组,差异有统计学意义(P<0.05)。结论:基于患者BMI调节管电流个性化成人胸部低剂量CT扫描方案,图像质量可满足临床诊断要求,有效降低辐射剂量,减少潜在辐射风险。 展开更多
关键词 成人 胸部 电子计算机体层扫描 低剂量 图像
下载PDF
上一页 1 2 70 下一页 到第
使用帮助 返回顶部