期刊文献+
共找到14,354篇文章
< 1 2 250 >
每页显示 20 50 100
A Stroke-Limitation AMD Control System with Variable Gain and Limited Area for High-Rise Buildings
1
作者 Zuo-Hua Li Qing-Gui Wu +1 位作者 Jun Teng Chao-Jun Chen 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第1期865-884,共20页
Collisions between a moving mass and an anti-collision device increase structural responses and threaten structural safety.An active mass damper(AMD)with stroke limitations is often used to avoid collisions.However,a ... Collisions between a moving mass and an anti-collision device increase structural responses and threaten structural safety.An active mass damper(AMD)with stroke limitations is often used to avoid collisions.However,a strokelimited AMD control system with a fixed limited area shortens the available AMD stroke and leads to significant control power.To solve this problem,the design approach with variable gain and limited area(VGLA)is proposed in this study.First,the boundary of variable-limited areas is calculated based on the real-time status of the moving mass.The variable gain(VG)expression at the variable limited area is deduced by considering the saturation of AMD stroke.Then,numerical simulations of a stroke-limited AMD control system with VGLA are conducted on a high-rise building structure.These numerical simulations show that the proposed approach has superior strokelimitation performance compared with a stroke-limited AMD control system with a fixed limited area.Finally,the proposed approach is validated through experiments on a four-story steel frame. 展开更多
关键词 high-rise buildings active control stroke limitations variable gain variable limited area
下载PDF
Study on Evacuation Strategy of Commercial High-Rise Building under Fire Based on FDS and Pathfinder
2
作者 Zheng Yan Ying Wang +1 位作者 Longxiao Chao Jian Guo 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第2期1077-1102,共26页
With the development of economy and society and the growth of population,the high-rise and multi-function of commercial buildings have become an international trend.But it also poses huge fire hazards.Most of the exis... With the development of economy and society and the growth of population,the high-rise and multi-function of commercial buildings have become an international trend.But it also poses huge fire hazards.Most of the existing studies’research objects are predominantly high-rise residential buildings,without considering the impact of different functional zones(Standard floor,entertainment zone,office zone,equipment room and so on)and personnel distribution of commercial buildings evacuation.And the influence of using elevators to carry evacuees on the refuge floor on personnel evacuation is rarely studied.In this work,the fire scenario of the Yangtze River InternationalConferenceCenter,a high-rise commercial building,is simulated with the Pyrosim programto get the necessary parameters under various fire scenarios and to calculate the available evacuation time TASET.At the same time,according to the complex functional zone of the commercial high-rise building and the distribution of people in different time periods,a reasonable evacuation strategy is developed and simulated by Pathfinder software.The results indicate that unorganized evacuation will lead individuals to take the erroneous evacuation route,resulting in a vast region of congestion;comprehensive consideration of the time staggering and the reasonable distribution of evacuation routes can significantly improve evacuation efficiency,and the TRSET of night and working hours is 36.6%–55.3%and 49.9%–79.6%of unorganized evacuation,respectively.For the night fire,60%of the people use elevator-refuge floor to evacuate is the optimal strategy;for the fire during working hours,half of the people on standard floors use the elevator to evacuate and people on multifunctional floors evacuate in four batches is the best plan.The results of this study can provide viable solutions and a foundation for analyzing the fire evacuation and safety of big commercial high-rise buildings. 展开更多
关键词 high-rise building fire personnel evacuation refuge floor safety analysis
下载PDF
A novel control strategy for reproducing the floor motions of high-rise buildings by earthquake-simulating shake tables
3
作者 Yuteng Cao Zhe Qu Xiaodong Ji 《Earthquake Research Advances》 CSCD 2024年第1期67-75,共9页
To enable the experimental assessment of the seismic performance of full-scale nonstructural elements with multiple engineering parameters(EDPs),a three-layer testbed named Nonstructural Element Simulator on Shake Tab... To enable the experimental assessment of the seismic performance of full-scale nonstructural elements with multiple engineering parameters(EDPs),a three-layer testbed named Nonstructural Element Simulator on Shake Table(NEST)has been developed.The testbed consists of three consecutive floors of steel structure.The bottom two floors provide a space to accommodate a full-scale room.To fully explore the flexibility of NEST,we propose a novel control strategy to generate the required shake table input time histories for the testbed to track the target floor motions of the buildings of interest with high accuracy.The control strategy contains two parts:an inverse dynamic compensation via simulation of feedback control systems(IDCS)algorithm and an offline iteration procedure based on a refined nonlinear numerical model of the testbed.The key aspects of the control strategy were introduced in this paper.Experimental tests were conducted to simulate the seismic responses of a full-scale office room on the 21^(st)floor of a 42-story high-rise building.The test results show that the proposed control strategy can reproduce the target floor motions of the building of interest with less than 20%errors within the specified frequency range. 展开更多
关键词 Shake table test Nonstructural element high-rise building Open-loop IDCS algorithm Off-line iteration
下载PDF
A Study on Factors Influencing Cost Overrun in High-rise Building Construction across India 被引量:1
4
作者 Mohammed Tayyab Mohammed Furkhan +2 位作者 Mohammed Rizwan M.Jameel, Aaron Chadee 《Journal of Smart Buildings and Construction Technology》 2023年第1期52-83,共32页
Cost overrun is a common problem in construction projects worldwide.Most Indian construction projects,particularly those involving high-rise buildings,have had severe cost overruns.For managers,architects,engineers,an... Cost overrun is a common problem in construction projects worldwide.Most Indian construction projects,particularly those involving high-rise buildings,have had severe cost overruns.For managers,architects,engineers,and contractors,completing building projects within the specified cost budget has become the most important and hard assignment.Since it is common for high-rise building projects to go over budget,the aim of this study is to find out the causes of cost overruns and provide effective measures.The study found 70 cost overrun factors based on a comprehensive literature review and expert opinions.A Google form questionnaire was distributed to 150 construction professionals across India.After following up,101 of the 150 responses were received.A five-point Likert scale was used and the acquired data was analyzed and ranked using the Relative Importance Index(RII)technique.According to the findings of RII,the top ten critical factors influencing cost overruns were frequent change orders during construction by the owner,delay in construction,escalation of material prices,market inflation or deflation,rework,frequent changes in design,inaccurate evaluation of the project timeline,unforeseen ground condition,inaccurate quantity take-off,and delay in progressive payment by the owner.Spearman’s rank correlation test revealed that there is a very significant relationship between the rankings of factors provided by the owner,the consultant,and the contractor.In addition,a factor analysis tool in the SPSS software was also used to categorize the seventy factors into sixteen core components.The top ten critical factors were presented to subject matter experts,and their suggestions were being compiled.These results are expected to help construction professionals minimize cost overruns,improve cost control measures,and initiate future research. 展开更多
关键词 Cost overrun high-rise buildings RII Factor analysis Subject matter expert(SME) INDIA
下载PDF
Seismic loss assessment of RC high-rise buildings designed according to Eurocode 8
5
作者 Jelena Pejovic Nina Serdar 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2023年第3期807-824,共18页
A probabilistic seismic loss assessment of RC high-rise(RCHR)buildings designed according to Eurocode 8 and located in the Southern Euro-Mediterranean zone is presented herein.The loss assessment methodology is based ... A probabilistic seismic loss assessment of RC high-rise(RCHR)buildings designed according to Eurocode 8 and located in the Southern Euro-Mediterranean zone is presented herein.The loss assessment methodology is based on a comprehensive simulation approach which takes into account ground motion(GM)uncertainty,and the random effects in seismic demand,as well as in predicting the damage states(DSs).The methodology is implemented on three RCHR buildings of 20-story,30-story and 40-story with a core wall structural system.The loss functions described by a cumulative lognormal probability distribution are obtained for two intensity levels for a large set of simulations(NLTHAs)based on 60 GM records with a wide range of magnitude(M),distance to source(R)and different site soil conditions(SS).The losses expressed in percent of building replacement cost for RCHR buildings are obtained.In the estimation of losses,both structural(S)and nonstructural(NS)damage for four DSs are considered.The effect of different GM characteristics(M,R and SS)on the obtained losses are investigated.Finally,the estimated performance of the RCHR buildings are checked to ensure that they fulfill limit state requirements according to Eurocode 8. 展开更多
关键词 RC high-rise buildings seismic loss assessment loss functions nonlinear time-history analysis(NLTHA) cumulative lognormal probability distribution random effects Eurocode 8
下载PDF
Analysis of the Performances of a New Type of Alumina Nanocomposite Structural Material Designed for the Thermal Insulation of High-Rise Buildings
6
作者 Yue Yu 《Fluid Dynamics & Materials Processing》 EI 2023年第3期697-709,共13页
The sol-gel method is used to prepare a new nano-alumina aerogel structure and the thermal properties of this nanomaterial are investigated comprehensively using electron microscope scanning,thermal analysis,X-ray and... The sol-gel method is used to prepare a new nano-alumina aerogel structure and the thermal properties of this nanomaterial are investigated comprehensively using electron microscope scanning,thermal analysis,X-ray and infrared spectrometer analysis methods.It is found that the composite aerogel alumina material has a multi-level porous nano-network structure.When employed for the thermal insulation of high-rise buildings,the alumina nanocomposite aerogel material can lead to effective energy savings in winter.However,it has almost no energy-saving effect on buildings where energy is consumed for cooling in summer. 展开更多
关键词 ALUMINA NANOMATERIALS low thermal conductivity high-rise building insulation materials sol-gel method
下载PDF
Discussion on Construction Technology and Welding Deformation of High-Rise Steel Frame Structure
7
作者 Sijin He Xinzhong Leng 《Journal of World Architecture》 2023年第5期23-28,共6页
Because of urbanization,land resources in China’s cities has become increasingly scarce.Therefore,modern buildings are becoming taller,making high-rise steel frame structures the new favorite of the construction indu... Because of urbanization,land resources in China’s cities has become increasingly scarce.Therefore,modern buildings are becoming taller,making high-rise steel frame structures the new favorite of the construction industry.However,the construction of high-rise steel frame structures requires advanced technology.If the construction technology is effectively implemented and the welding techniques of the construction personnel align with the requirements for high-rise steel frame structures,it can help mitigate deformations in the steel structure,thus preserving the overall construction quality of high-rise steel frame structures.To enhance the applicability of steel frame structures in high-rise buildings,this paper focuses on analyzing the optimization path for the construction process of high-rise steel frame structures.It introduces a tailored approach to control welding-induced deformations in steel frame structures,aiming to make a valuable contribution to the advancement of China’s construction industry. 展开更多
关键词 high-rise steel frame structure Construction technology Welding deformation Structural stability
下载PDF
Vibration Control of a High-Rise Building Structure:Theory and Experiment 被引量:2
8
作者 Yuhua Song Wei He +1 位作者 Xiuyu He Zhiji Han 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2021年第4期866-875,共10页
In this study,an innovative solution is developed for vibration suppression of the high-rise building.The infinite dimensional system model has been presented for describing high-rise building structures which have a ... In this study,an innovative solution is developed for vibration suppression of the high-rise building.The infinite dimensional system model has been presented for describing high-rise building structures which have a large inertial load with the help of the Hamilton’s principle.On the basis of this system model and with the use of the Lyapunov’s direct method,a boundary controller is proposed and the closed-loop system is uniformly bounded in the time domain.Finally,by using the Smart Structure laboratory platform which is produced by Quancer,we conduct a set of experiments and find that the designed method is resultful. 展开更多
关键词 Boundary control distributed parameter systems high-rise building structure vibration control
下载PDF
Analysis and control of vibration of ropes in a high-rise elevator under earthquake excitation 被引量:1
9
作者 Thuan Xuan Nguyen Nanako Miura Akira Sone 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2019年第2期447-460,共14页
In this research, the vibration of elevator ropes, including the main rope and compensation rope are investigated simultaneously in a high-rise elevator system under earthquake excitation. Moreover, the paper presents... In this research, the vibration of elevator ropes, including the main rope and compensation rope are investigated simultaneously in a high-rise elevator system under earthquake excitation. Moreover, the paper presents a new control method to restrain the sway of both ropes. This study considers varying rope lengths during elevator operation which cause other system parameters such as natural frequency, and damping ratio to be time-variant variables. The dynamics of the ropes are analyzed by solving the governing non-stationary, nonlinear equation numerically. In order to mitigate the vibration of ropes in several motion conditions, particularly upwards movement, downward movement, stopped at the lowest position, and stopped at the highest position, an active equipment is installed at the compensation sheave. The stability of the system using the controller is analyzed at four states: without disturbance and static car, without disturbance and mobile car, including disturbance and static car, and including disturbance and mobile car. The efficiency of the controller used for dampening the vibration of elevator ropes is validated by numerical simulation results. 展开更多
关键词 ELEVATOR ropes high-rise ELEVATOR VIBRATION CONTROLLER STABILITY
下载PDF
Experimental investigation of turbulent flows around high-rise structure foundations and implications on scour 被引量:1
10
作者 Dong-fang Liang Hao Jia +1 位作者 Yang Xiao Sai-yu Yuan 《Water Science and Engineering》 EI CAS CSCD 2022年第1期47-56,共10页
Many studies have been undertaken to predict local scour around offshore high-rise structure foundations(HRSFs),which have been used in constructing the Donghai Wind Farm in China.However,there have been few works on ... Many studies have been undertaken to predict local scour around offshore high-rise structure foundations(HRSFs),which have been used in constructing the Donghai Wind Farm in China.However,there have been few works on the turbulent flow that drives the scour process.In this study,the characteristics of the turbulent flow fields around an HRSF were investigated using the particle image velocimetry technique.The mean flow,vorticity,and turbulence intensity were analyzed in detail.The relationship between the flow feature and scour development around an HRSF was elaborated.The results showed that the flow velocity increased to its maximum value near the third row of the pile group.The shear layer and wake vortices could not be fully developed downstream of the last row of the piles at small Reynolds numbers.The strong flow and turbulent fluctuation near the third piles explained the existence of a longtail scour pattern starting from the HRSF shoulders and a trapezoidal deposition region directly downstream of HRSF.This laboratory experiment gains insight into the mechanism of the turbulent flow around HRSFs and provides a rare dataset for numerical model verifications. 展开更多
关键词 high-rise structure foundations(HRSFs) Turbulent flow fields Particle image velocimetry(PIV) SCOUR Sediment transport
下载PDF
Seismic performance of high-rise buildings in selected regions in Saudi Arabia according to different seismic codes 被引量:1
11
作者 Sayed Mahmoud Mohamed Alsearheed Waleed Abdallah 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2021年第1期179-191,共13页
The design code for each country is revised and updated based on an expected zone’s seismic intensities,geotechnical site classifications,structural systems,construction materials and methods of construction in order... The design code for each country is revised and updated based on an expected zone’s seismic intensities,geotechnical site classifications,structural systems,construction materials and methods of construction in order to provide more realistic considerations of seismic demand,seismic response,and seismic capacity.Based on the aforementioned provisions,structures designed according to different seismic codes may yield different performances for the same level of hazard.This study aims to investigate and compare the induced responses related to the earthquake-resistant design of reinforced concrete(RC)buildings according to the Saudi building code(SBC-301),American code(ASCE-7),uniform building code(UBC-97),and European code(EC-8).In order to account for the provision regarding the hazard specification and its effect on the induced seismic responses,four regions in the Kingdom of Saudi Arabia with different seismic levels are selected.The code provisions related to the specification of site classification and its effect on the induced design base shear are investigated as well.Significant differences are observed in the induced responses with the variation in seismic design codes for the considered seismic hazards and site classifications. 展开更多
关键词 high-rise building SBC-301 international seismic codes seismic zones site classifications
下载PDF
High-rise building fire pre-warning model based on the support vector regression 被引量:1
12
作者 张立宁 张奇 安晶 《Journal of Beijing Institute of Technology》 EI CAS 2015年第3期285-290,共6页
Aiming at reducing the deficiency of the traditional fire pre-warning algorithms and the intelligent fire pre-warning algorithms such as artificial neural network,and then to improve the accuracy of fire prewarning fo... Aiming at reducing the deficiency of the traditional fire pre-warning algorithms and the intelligent fire pre-warning algorithms such as artificial neural network,and then to improve the accuracy of fire prewarning for high-rise buildings,a composite fire pre-warning controller is designed according to the characteristic( nonlinear,less historical data,many influence factors),also a high-rise building fire pre-warning model is set up based on the support vector regression( SV R). Then the wood fire standard history data is applied to make empirical analysis. The research results can provide a reliable decision support framework for high-rise building fire pre-warning. 展开更多
关键词 high-rise buildings fire composite fire pre-warning systemdesign the support vector regression pre-warning model
下载PDF
Numerical Simulation of Wind Field Characteristics around Two Adjacent High-Rise Buildings 被引量:1
13
作者 Wenkai He Weibin Yuan 《Journal of Applied Mathematics and Physics》 2014年第6期264-268,共5页
This paper based on Reynolds-averaged Navier-Stokes equations standard ?model [1];the surface pressure on the wind field around two adjacent high-rise buildings was numerically simulated with software Fluent. The resu... This paper based on Reynolds-averaged Navier-Stokes equations standard ?model [1];the surface pressure on the wind field around two adjacent high-rise buildings was numerically simulated with software Fluent. The results show that with the influence of adjacent high-rise building, numerical simulation is a good way to study the wind field around high-rise building and the distribution of wind pressure on building’ surface. The pressures on the windward surface are positive with the maximum at 2/3 H height and have lower values on the top and bottom. The pressures on the leeward surface and two sides were negative. Due to the serious flow separation at the corner of building’s windward, the wind field has a high turbulent kinetic energy. 展开更多
关键词 high-rise Building NUMERICAL Simulation WIND Field Characteristics TURBULENCE Model
下载PDF
Influence of Horizontal Flow on Atrium in High-Rise Residential Building
14
作者 LI Nian-ping,LI Jing,HE Dong-yue,ZHANG Min-hui,HOU Su-juan(College of Civil Engineering,Hunan University,Changsha,Hunan 410082,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期15-18,共4页
In this study a 10-storied residential building model was employed to clarify the ventilation characteristics of the atrium and the rooms,which were effected by the different forms of lateral openings.The experiment w... In this study a 10-storied residential building model was employed to clarify the ventilation characteristics of the atrium and the rooms,which were effected by the different forms of lateral openings.The experiment was conducted under the combined effect of wind force and thermal buoyancy,and the similarity requirements were satisfied.The results have shown that the different forms of lateral openings cause the different ventilation effect of the building,and also have some certain regularity.The conclusions provide a theoretical foundation for how to use the ventilation of atrium better in high-rise residential building. 展开更多
关键词 high-rise RESIDENTIAL building ATRIUM model EXPERIMENT HORIZONTAL flow NATURAL ventilation
下载PDF
Field measurements for calibration of simplified models of the stiffening effect of infill masonry walls in high-rise RC framed and shear-wall buildings
15
作者 Zhou Yun Pei Yilin +2 位作者 Zhou Yi Hyeon-Jong Hwang Yi Weijian 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2020年第1期87-104,共18页
As a type of nonstructural component, infill walls play a significant role in the seismic behavior of high-rise buildings. However, the stiffness of the infill wall is generally either ignored or considered by simplif... As a type of nonstructural component, infill walls play a significant role in the seismic behavior of high-rise buildings. However, the stiffness of the infill wall is generally either ignored or considered by simplified empirical criteria that lead to a period shortening. The difference can be greatly decreased by using a structural identification methodology. In this study, an ambient vibration test was performed on four on-site reinforced concrete high-rise buildings, and the design results were compared with the PKPM models using corresponding finite element(FE) models. A diagonal strut model was used to simulate the behavior of the infill wall, and the identified modal parameters measured from the on-site test were employed to calibrate the parameters of the diagonal strut in the FE models. The SAP2000 models with calibrated elastic modulus were used to evaluate the seismic response in the elastic state. Based on the load-displacement relationship of the infill wall, nonlinear dynamic analysis models were built in PERFORM-3 D and calibrated using the measured modal periods. The analysis results revealed that the structural performance under small/large earthquake records were both strengthened by infill walls, and the contribution of infill walls should be considered for better accuracy in the design process. 展开更多
关键词 high-rise building ambient vibration test model calibration infi ll wall seismic performance nonlinear dynamic analysis
下载PDF
Model Reduction Methods for High-Rise Buildings with Active Mass Damper Control Systems
16
作者 Jun Teng Hou-Bing Xing Cheng-Yin Liu 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2013年第6期37-45,共9页
To improve the performance of an active mass damper control system,the controller should be designed based on a reduced-order model. An improved method based on balanced truncation method was proposed to reduce the di... To improve the performance of an active mass damper control system,the controller should be designed based on a reduced-order model. An improved method based on balanced truncation method was proposed to reduce the dimension of high-rise buildings,and was compared with other widely used reduction methods by using a framework with ten floors. This optimized method has improvement of reduction process and choice of the order. Based on the reduced-order model obtained by the improved method and pole-assignment algorithm,a controller was designed. Finally,a comparative analysis of structural responses,transfer functions,and poles was conducted on an actual high-rise building. The results show the effectiveness of the improved method. 展开更多
关键词 high-rise building active mass damper model reduction controller design
下载PDF
Structural form selection of the high-rise buildingwith the improved BP neural network
17
作者 赵光哲 Yang Hanting +2 位作者 Tu Bing Zhou Meiling Zhou Chengle 《High Technology Letters》 EI CAS 2020年第1期92-97,共6页
As civil engineering technology development,the structural form selection is more and more critical in design of high-rise buildings.However,structural form selection involves expertise knowledge and changes with the ... As civil engineering technology development,the structural form selection is more and more critical in design of high-rise buildings.However,structural form selection involves expertise knowledge and changes with the environment which makes the task arduous.An approach utilizing improved back propagation(BP)neural network optimized by the Levenberg-Marquardt(L-M)algorithm is proposed to extract the main controlling factors of structural form selection.Then,an intelligent expert system with artificial neural network is constructed to design high-rise buildings structure effectively.The experiment tests the model in 15 well-known architecture samples and get the prediction accuracy of 93.33%.The results show that the method is feasible and can help designers select the appropriate structural form. 展开更多
关键词 BACK propagation(BP)neural network high-rise building STRUCTURAL form selection Levenberg-Marquardt(L-M)algorithm
下载PDF
Method for Evaluating the Influence of Obstruction of Sea Breeze by Clusters of High-Rise Buildings on the Urban Heat Island Effect
18
作者 Shota Sashiyama Kayoko Yamamoto 《Journal of Environmental Protection》 2014年第11期983-996,共14页
This study aims to propose a method for quantitatively evaluating the influence which the obstruction of sea breezes by clusters of high-rise buildings has on the urban heat island effect using a weather simulation mo... This study aims to propose a method for quantitatively evaluating the influence which the obstruction of sea breezes by clusters of high-rise buildings has on the urban heat island effect using a weather simulation model and Geographic Information Systems (GIS). Specifically, a method of evaluating the influence of the obstruction of sea breeze by high-rise buildings on the urban heat island effect was proposed. In the method, two scenarios that imagine urban forms which differ with regard to whether or not they contain high-rise buildings are created and weather simulation is conducted, and the results of the simulations are comparatively analyzed focusing on temperature and wind speed. Evaluation was conducted in two stages, and Shiodome of Minato City in the Tokyo Metropolis was selected as the region for evaluation. In two stages of evaluation, a rise in temperature of approximately 0.3 K and a reduction in wind speed of approximately 1 m/s were observed in a region approximately five to ten kilometers square downwind of high-rise buildings in the period 6 PM to 9 PM, and a higher temperature caused by the obstruction of sea breeze by high-rise buildings was identified. The fact that such a higher temperature was confirmed in the time period from 6 PM onwards, in which the temperature decreases, reveals that obstruction of sea breeze by high-rise buildings dulls the decrease in temperature which occurs from evening onwards, and influences nighttime urban heat island formation. 展开更多
关键词 Urban Heat ISLAND Effect SEA Breeze CLUSTERS of high-rise Buildings WEATHER Simulation Model GIS
下载PDF
Effect of Lead-Rubber Bearing Isolators in Reducing Seismic Damage for a High-Rise Building in Comparison with Normal Shear Wall System
19
作者 Mahmoud Fakih Jaafar Hallal +1 位作者 Hassan Darwich Hala Damerji 《Structural Durability & Health Monitoring》 EI 2021年第3期247-260,共14页
Seismic earthquakes are a real danger for the construction evolution of high rise buildings.The rate of earthquakes around the world is noteworthy in a wide range of construction areas.In this study,we present the dyn... Seismic earthquakes are a real danger for the construction evolution of high rise buildings.The rate of earthquakes around the world is noteworthy in a wide range of construction areas.In this study,we present the dynamic behavior of a high-rise RC building with dynamic isolators(lead-rubber-bearing),in comparison with a traditional shear wall system of the same building.Seismic isolation has been introduced in building construction to increase the structural stability and to protect the non-structural components against the damaging effects of an earthquake.In order to clarify the influence of incorporating lead rubber bearing isolators in the seismic response and in reducing seismic damages;a comparative study is performed between a fixed base system(shear wall system)and an isolated base system(Lead Rubber Bearing)on an irregular high rise reinforced concrete(RC)building located in Beirut consisting of 48 storeys almost asymmetric orthogonally.For this purpose,a non-linear analysis of a real earthquake acceleration record(EI Centro seismic signal)is conducted,so that the mode shapes,the damping ratio and the natural frequencies of the two models are obtained using ETABS software.The results prove a substantial elongation of the building period,as well as a reduction in the building displacement,the roof acceleration,the inter-storey drift ratio and the base shear force of isolated building relative to fixed-base building.This study proves that this technology is applicable to high rise buildings with acceptable results. 展开更多
关键词 Seismic damage non-linear time history analysis high-rise RC building seismic response analysis lead rubber bearing
下载PDF
Development of the Separate Air-Supply Type of Pressurization Smoke Control System for the Stairwells of High-Rise Buildings in Korea
20
作者 Jung-Yup Kim Hyun-Joon Shin +2 位作者 Chan-Sol Ahn Ji-Seok Kim Sang-Hyun Joo 《Open Journal of Fluid Dynamics》 2014年第3期251-262,共12页
The pressurization smoke control system has been commonly used as a smoke control system at the emergency stairs of high-rise buildings. However, a higher possibility of overpressure between the lobby and the accommod... The pressurization smoke control system has been commonly used as a smoke control system at the emergency stairs of high-rise buildings. However, a higher possibility of overpressure between the lobby and the accommodation or pressure drop in the lobby could lead to failure in achievement of the purpose of pressurization system, particularly when supplying the leakage and supplementary air flow through one air-supply path at a time. To improve this particular issue, the devise configurations, as well as the different ways to supply the leakage and supplementary air flow through the different flow passages have been proposed. The performance of the trial product was evaluated on the test bed, ultimately providing a safe evacuation environment if high-rise buildings fired. 展开更多
关键词 PRESSURIZATION System SMOKE Control high-rise Building EVACUATION STAIRWELL Field EXPERIMENT
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部