Objective: To study the clinical efficacy and methods of permanent implantation of radioactive I-125 seed in surgery for local advanced non small lung cancer (LANSCLC). Methods: From Apr. 2004 to Apr. 2006, the I-...Objective: To study the clinical efficacy and methods of permanent implantation of radioactive I-125 seed in surgery for local advanced non small lung cancer (LANSCLC). Methods: From Apr. 2004 to Apr. 2006, the I-125 seeds were implanted into 30 patients with LANSCLC in surgery. The numbers of seeds were 10-40. The chemotherapy was performed in 10 to 14 days after operation. Results: There was no operative death, and the distribution of seeds and complications were reviewed by CT and X-ray after treatment. The distribution of seeds was satisfactory in all patients. The complete response rate (CR) was 56.6% and the part response (PR) was 26.6%. The overall response rate was 83.3% after 4-24 months of surgery. There was no one occurred radiation pneumonia. Prospective efficacy await further follow-up. Conclusion: Permanent implantation of 1-125 seed in surgery for LANSCLC, is a safe and effective method with mild complications.展开更多
Objective: Although Iodine-125 (125I) has been widely used for in vitro studies because of its relatively long half-life (60.1 days), 125I imaging is limited because of its low energy (27 - 35 keV), even in an animal-...Objective: Although Iodine-125 (125I) has been widely used for in vitro studies because of its relatively long half-life (60.1 days), 125I imaging is limited because of its low energy (27 - 35 keV), even in an animal-dedicated system. In this study, imaging characteristics of 125I were assessed using a small animal-dedicated imaging system and clinical scanner. Methods: Using the Siemens Inveon and Siemens Symbia TruePoint systems, imaging characteristics such as resolution, sensitivity, and image quality were compared. Mouse high resolution (MHR-0.5), mouse general purpose (MGP-1.0), and mouse high sensitivity (MHS-2.0) collimators were used for the Inveon scanner, and low energy high-resolution (LEHR) and low energy all-purpose (LEAP) collimators were used for the Symbia TruePoint. For animal imaging, 16.8 MBq of 125I was administered to BALB/c mice intravenously, and the planar image and single-photon emission computed tomography (SPECT) were obtained using both scanners. Results: The resolution of 125I for the Inveon scanner was 3.98 mm full width at half maximum (FWHM) at a 30-mm distance with the MHR-0.5 collimator, and the value of Symbia scanner was 8.72 mm FWHM at a 30-mm distance with the LEHR collimator. The sensitivity of 125I for the Inveon scanner was 21.87 cps/MBq, and the value for the clinical scanner was 30.55 cps/MBq. The planar images of mice were successfully obtained at the level of evaluating specific binding in both scanners. Conclusion: 125I small animal imaging can be achieved with a clinical scanner. This result may enhance the utilization of 125I small animal imaging using a clinical scanner.展开更多
文摘Objective: To study the clinical efficacy and methods of permanent implantation of radioactive I-125 seed in surgery for local advanced non small lung cancer (LANSCLC). Methods: From Apr. 2004 to Apr. 2006, the I-125 seeds were implanted into 30 patients with LANSCLC in surgery. The numbers of seeds were 10-40. The chemotherapy was performed in 10 to 14 days after operation. Results: There was no operative death, and the distribution of seeds and complications were reviewed by CT and X-ray after treatment. The distribution of seeds was satisfactory in all patients. The complete response rate (CR) was 56.6% and the part response (PR) was 26.6%. The overall response rate was 83.3% after 4-24 months of surgery. There was no one occurred radiation pneumonia. Prospective efficacy await further follow-up. Conclusion: Permanent implantation of 1-125 seed in surgery for LANSCLC, is a safe and effective method with mild complications.
文摘Objective: Although Iodine-125 (125I) has been widely used for in vitro studies because of its relatively long half-life (60.1 days), 125I imaging is limited because of its low energy (27 - 35 keV), even in an animal-dedicated system. In this study, imaging characteristics of 125I were assessed using a small animal-dedicated imaging system and clinical scanner. Methods: Using the Siemens Inveon and Siemens Symbia TruePoint systems, imaging characteristics such as resolution, sensitivity, and image quality were compared. Mouse high resolution (MHR-0.5), mouse general purpose (MGP-1.0), and mouse high sensitivity (MHS-2.0) collimators were used for the Inveon scanner, and low energy high-resolution (LEHR) and low energy all-purpose (LEAP) collimators were used for the Symbia TruePoint. For animal imaging, 16.8 MBq of 125I was administered to BALB/c mice intravenously, and the planar image and single-photon emission computed tomography (SPECT) were obtained using both scanners. Results: The resolution of 125I for the Inveon scanner was 3.98 mm full width at half maximum (FWHM) at a 30-mm distance with the MHR-0.5 collimator, and the value of Symbia scanner was 8.72 mm FWHM at a 30-mm distance with the LEHR collimator. The sensitivity of 125I for the Inveon scanner was 21.87 cps/MBq, and the value for the clinical scanner was 30.55 cps/MBq. The planar images of mice were successfully obtained at the level of evaluating specific binding in both scanners. Conclusion: 125I small animal imaging can be achieved with a clinical scanner. This result may enhance the utilization of 125I small animal imaging using a clinical scanner.