期刊文献+
共找到1,598篇文章
< 1 2 80 >
每页显示 20 50 100
Vector Shift Method for Islanding Detection Based on Simulation Test
1
作者 侯梅毅 高厚磊 +1 位作者 刘炳旭 邹贵彬 《Transactions of Tianjin University》 EI CAS 2008年第2期123-127,共5页
Vector shift(VS)is one of the typical methods used for islanding detection in distributed generations.This paper investigates the impact of both the active power imbalance and load variation on VS method.The investiga... Vector shift(VS)is one of the typical methods used for islanding detection in distributed generations.This paper investigates the impact of both the active power imbalance and load variation on VS method.The investigation was conducted via simulation test in the power system dynamic simulation laboratory of Shandong University.The results show that it will take longer time for the VS relay to detect islanding state with the decrease of active power imbalance.In some cases,the vector shift angle is smaller than the setting and VS method would not be able to detect islanding state.In addition,the performance of VS method is impacted by the load variation in normal operation in which the distributed generator is operated in parallel with the main grid.The simulation results show that VS method would cause nuisance tripping if the load changes sharply. It can be summarized that VS method would be unable to reliably discriminate islanding state and normal system disturbances in some cases. 展开更多
关键词 distributed generation islanding detection vector shift physical model simulation islanding operation
下载PDF
Distributed Generation Islanding Effect on Distribution Networks and End User Loads Using the Master-Slave Islanding Method
2
作者 Lambros Ekonomou George P. Fotis +1 位作者 Vasiliki Vita Valeri Mladenov 《Journal of Power and Energy Engineering》 2016年第10期1-24,共24页
This study aims to address the feasibility of planned islanding operation and to investigate the effect of unplanned islanding using the master-slave islanding method for controlling the distributed generation units d... This study aims to address the feasibility of planned islanding operation and to investigate the effect of unplanned islanding using the master-slave islanding method for controlling the distributed generation units during grid-connected and islanding operation. Neplan desktop power simulation tool was used for the modelling and simulation of a realistic MV network with four different distributed generation technologies (diesel, gas, hydro and wind) along with their excitation and governor control systems, while an exponential model was used to represent the loads in the network. The dynamic and steady state behavior of the four distributed generation technologies were investigated during grid-connected operation and two transition modes to the islanding situation, planned and unplanned. The obtained results that validated through various case studies have shown that a suitable planned islanding transition could provide support to critical loads at the event of electricity utility outages. 展开更多
关键词 Distributed Generation Distribution Networks islanding Master-Slave islanding Method Neplan Simulation Tool
下载PDF
A Study on Control of Interconnection Inverter with FRT and Islanding Detection Functions
3
作者 Shoji Kawasaki Masahiro Ise 《Journal of Energy and Power Engineering》 2018年第1期26-34,共9页
In this study, the authors aim to develop the interconnection inverter ofPV (photovoltaic generation) system with FRT (fault ride thorough) function and islanding detection function, and analyze the interaction be... In this study, the authors aim to develop the interconnection inverter ofPV (photovoltaic generation) system with FRT (fault ride thorough) function and islanding detection function, and analyze the interaction between the both functions during the momentary voltage drop by using an analytical model of distribution system interconnected plural PV systems. Moreover, the authors propose a cooperated control method of the inverters ~vith the islanding detection function and FRT function, and carry out a numerical calculation in order to verify the validity of the proposed method. 展开更多
关键词 Interconnection inverter islanding islanding detection function momentary voltage drop FRT function.
下载PDF
Islanding Detection Method for Multi-Inverter Distributed Generation 被引量:3
4
作者 Alben CARDENAS Kodjo AGBOSSOU Mamadou Lamine DOUMBIA 《Journal of Electromagnetic Analysis and Applications》 2009年第3期170-180,共11页
Islanding detection is an essential function for safety and reliability in grid-connected distributed generation (DG) systems. Several methods for islanding detection are proposed, but most of them may fail under mult... Islanding detection is an essential function for safety and reliability in grid-connected distributed generation (DG) systems. Several methods for islanding detection are proposed, but most of them may fail under multi-source configurations, or they may produce important power quality degradation which gets worse with increasing DG penetration. This paper presents an active islanding detection algorithm for Voltage Source Inverter (VSI) based multi-source DG systems. The proposed method is based on the Voltage Positive Feedback (VPF) theory to generate a limited active power perturbation. Theoretical analyses were performed and simulations by MATLAB /Simulink /SimPowerSystems were used to evaluate the algorithm’s performance and its advantages concerning the time response and the effects on power quality, which turned out to be negligible. The algorithm performance was tested under critical conditions: load with unity power factor, load with high quality factor, and load matching DER’s powers. 展开更多
关键词 Distributed GENERATION (DG) Interconnected POWER Systems islanding Detection POWER GENERATION Voltage POSITIVE Feedback.
下载PDF
Frequency-Feedback Based Islanding Detection Algorithm for Micro-Grid 被引量:1
5
作者 李永丽 李盛伟 +1 位作者 摆世彬 牛冲宣 《Transactions of Tianjin University》 EI CAS 2008年第2期85-91,共7页
The unintentional islanding of micro-grid may cause negative impacts on distribution loads and distributed generations,so it must be detected within the acceptable duration.In this paper a new islanding detection algo... The unintentional islanding of micro-grid may cause negative impacts on distribution loads and distributed generations,so it must be detected within the acceptable duration.In this paper a new islanding detection algorithm is proposed.This algorithm introduces the frequency feedback method by the reactive power compensation to derive the frequency continuous shift. Accordingly,the islanding can be detected by monitoring the frequency within 0.1 s.The simulation results prove that this algorithm has extremely small non-detection zone,and meanwhile it presents an excellent islanding detection speed as well. 展开更多
关键词 distributed generation MICRO-GRID islanding detection reactive power compensation
下载PDF
New Islanding Detection Method with Better Performance in Presence of Non-resistive Load 被引量:1
6
作者 Fang Jun-long Wang Ji +5 位作者 Zou Shi-qi Sun Xiao-yong Zhou Yang Yang Yu-qi Feng Chong-yang Li Xiang-yun 《Journal of Northeast Agricultural University(English Edition)》 CAS 2018年第2期65-76,共12页
Islanding detection is a mandatory component in grid-connected photovoltaic (PV) inverters. It is also a key issue in the photovoltaic agriculture. In this work, an overview on the islanding effect in grid-connected... Islanding detection is a mandatory component in grid-connected photovoltaic (PV) inverters. It is also a key issue in the photovoltaic agriculture. In this work, an overview on the islanding effect in grid-connected PV power systems was provided. Various islanding detection methods were introduced and their strength and weakness were dicussed. An improved islanding detection method was proposed based on active frequency drift (AFD). The new method tolerated capacitive and inductive loads, because its perturbation signal was not offset by the non-resistive load. The new method through simulation in MATLAB/Simulink was evaluated and the advantages of the new method were demonstrated. 展开更多
关键词 photovoltaic agriculture grid-connected photovoltaic power system islanding detection SIMULATION
下载PDF
Detailed Analysis of Micro-Grid Stability during Islanding Mode under Different Load Conditions 被引量:2
7
作者 Rashad M. Kamel A. Chaouachi Ken Nagasaka 《Engineering(科研)》 2011年第5期508-516,共9页
Today, several types of DGs are connected together and formed a small power system called micro-grid (MG). MG is connected to the primary distribution network and usually operates in normal connecting mode. When a sev... Today, several types of DGs are connected together and formed a small power system called micro-grid (MG). MG is connected to the primary distribution network and usually operates in normal connecting mode. When a severe fault occurs in the primary distribution network, then the MG will transfer to islanding mode. In this paper a complete model is developed to simulate the dynamic performance of the MG during and subsequent to islanding process. The model contains of a solid oxide fuel cell (SOFC), a single shaft micro turbine, a flywheel, two photovoltaic panels and a wind generator system. All these micro sources are con-nected to the MG through inverters except the wind generation system. The inverters are modeled with two control strategies. The first strategy is PQ control which the inverter will inject a certain active and reactive powers. This type of inverter is used to interface micro turbine, fuel cell and photovoltaic panels to the MG. The second strategy is Vf control. This model is used to interface flywheel will act as the reference bus (slack bus) for the MG when islanding occurs. Two cases are studied: the first case discusses the effect of islanding process on frequency, voltage and active power of all micro sources when the MG imports active and reactive power from the primary distribution network. The second studied case, also, shows the effect of islanding on the previous quantities particularly when the MG exports active and reactive power to the pri-mary distribution network. Results showed that the existence of storage device (flywheel) with appropriate control of its inverter can keep the frequency of the MG and the voltages of all buses within their limited levels. The developed model is built in Matlab? Simulink? environment. 展开更多
关键词 MG Dynamic Performance islanding INVERTER and DISTRIBUTED Generators
下载PDF
Islanding Protection and Islanding Detection in Low Voltage CIGRE Distribution Network with Distributed Generations 被引量:1
8
作者 Ghullam Mustafa Bhutto Ehsan Ali +1 位作者 Jagdesh Kumar Muhammad Akram Bhayo 《Smart Grid and Renewable Energy》 2014年第6期152-159,共8页
The Power Quality (PQ), security, reliability etc., are the prime objectives of the power system. The protection is developed in such a way that it should be selective, fast, reliable and the cost effective. The study... The Power Quality (PQ), security, reliability etc., are the prime objectives of the power system. The protection is developed in such a way that it should be selective, fast, reliable and the cost effective. The study about the islanding protection in Low Voltage (LV) CIGRE distribution and networks like this has been proposed in this paper. This is achieved by developing the protection against the short circuit faults which might appear at the Medium Voltage (MV) bus. The protection of the network with significant penetration of the Distributed Generations (DGs) is a complicated process. The DG units which are directly connected to the grid such as synchronous or induction generators contribute large short power, whereas the DG units which are connected to the grid via inverters carry small amount of the short circuit power. This creates the problems in the protection of the network. If the proper protection coordination measures have not been taken, it might cause the mal-function of the protection devices which put the portion of the power network into the security threats. The selection of the islanding protection devices in this paper is made to protect the network against bi-directional currents at the time of short circuit fault. The LV CIGRE distribution network will enter into islanding if a fault is cleared at the MV bus by the proposed islanding protection devices. It is therefore, essential to detect the islanding in the CIGRE power network. The detection of the island in this network is another major objective of this paper. The detection of the island is proposed by using the technique which is based on the voltage phase angle difference. The simulations are carried out by using DIgSILENT power factory software version 15.0. 展开更多
关键词 islanding PROTECTION Loss of Grid (LOG) Over Current PROTECTION Under Voltage PROTECTION FUSES RELAYS Island Detection (ID)
下载PDF
Improved Active Islanding Detection Technique for Multi-Inverter Power System
9
作者 Jie Zhang Yu-Hua Cheng +1 位作者 Kai Chen Gen Qiu 《Journal of Electronic Science and Technology》 CAS CSCD 2021年第2期186-195,共10页
Due to the increased penetration of multi-inverter distributed generation(DG)systems,different DG technologies,inverter control methods,and other inverter functions are challenging the capabilities of islanding detect... Due to the increased penetration of multi-inverter distributed generation(DG)systems,different DG technologies,inverter control methods,and other inverter functions are challenging the capabilities of islanding detection.In addition,multi-inverter networks connecting the distribution system point of common coupling(PCC)create islanding at paralleling inverters,which adds the vulnerability of islanding detection.Furthermore,available islanding detection must overcome more challenges from non-detection zones(NDZs)under reduced power mismatches.Therefore,in this study,a new method called parameter self-adapting active islanding detection was utilized to minimize the dilution effect and reduce NDZs in multi-inverter power systems.The method utilizes an active frequency drift(AFD)method and applies a positive feedback gain of adoption parameters,which significantly minimizes NDZs at parallel inverters.The simulation and experimental outcomes indicate that the proposed method can effectively weaken the dilution effect in multi-inverter networks connecting the distribution system PCC. 展开更多
关键词 Active frequency drift(AFD) active islanding detection method multi-inverter power system non-detection zones(NDZs)
下载PDF
Performance Assessment of Islanding Detection for Mul-ti-inverter Grid-connected Photovoltaic Systems
10
作者 Xing Zhang Dong Xie 《Energy and Power Engineering》 2013年第4期1517-1520,共4页
Islanding detection is an essential function for safety and reliability in grid-connected Distributed Generation Systems (DGS). Passive and active islanding detection methods have been analyzed in literature consideri... Islanding detection is an essential function for safety and reliability in grid-connected Distributed Generation Systems (DGS). Passive and active islanding detection methods have been analyzed in literature considering DGS with only one inverter connected to the utility. With the big scale application of photovoltaic (PV) power systems, islanding detection technology of multi-inverter DGS has been paid more attention. This paper analyzes the performance of diverse islanding detection methods in multiple inverters grid-connected PV systems. Non-Detection Zones (NDZ) of multi-inverter systems in a load parameter space are used as analytical tool. The paper provides guidance for the islanding detection design in multiple grid-connected inverters. 展开更多
关键词 PHOTOVOLTAIC Power Systems islanding DETECTION Multi-inverter Non-Detection ZONES
下载PDF
Islanding Operation of Electrical Systems in Buildings
11
作者 David Johnston 《Energy and Power Engineering》 2013年第4期198-201,共4页
A control system was developed, which allows on-site generators within a building to operate in islanding mode, in the event of loss of grid supply. The on-site generation included a photovoltaic array and a back-up i... A control system was developed, which allows on-site generators within a building to operate in islanding mode, in the event of loss of grid supply. The on-site generation included a photovoltaic array and a back-up induction generator. Regulation include avoidance of sudden voltage and frequency changes at the transition to islanding mode, maintaining voltage and frequency within limits during islanding, and phase matching when the grid supply is re-established. Possible modes of operation during islanding were photovoltaic array alone, generator alone, or both sources operating in parallel. Control methods were considered for each of these, and the resulting voltage and frequency regulation was anal sized. The results show that voltage and frequency could be kept within limits, except during the transitions to and from islanding. At these times, the transients were minimised. 展开更多
关键词 ON-SITE GENERATION islanding Photovltaic REGULATION Re-synchronisation
下载PDF
Impact of Islanding on Governor Signal of Distributed Resources
12
作者 Mahdi Ghadiri Ali Moeini Hossein Yassami 《Journal of Electromagnetic Analysis and Applications》 2011年第2期56-64,共9页
Technical and economical impacts of distributed resources have encouraged big industry managers and distribution systems’ owners to utilize small type of electric generations. One important preventive issue to develo... Technical and economical impacts of distributed resources have encouraged big industry managers and distribution systems’ owners to utilize small type of electric generations. One important preventive issue to develop these units is islanding situation. Expert diagnosis system is needed to distinguish network cut off from normal occurrences. It should detect islanding in time to disconnect the unit and prevent any additional failures in equipment. An important part of synchronous generator is automatic load-frequency controller (ALFC). This controller is designed properly to respond to load variations and to fix frequency at constant value when working alone as an islanding system and to control output power when operating in parallel with the main. In this paper, a new approach based on monitoring ALFC re-sponse with regard to input signal to governor is introduced. Numbers of initial crossing value are introduced as an index for islanding detection. Simulation results show that input signal to governor has different characteristics in common disturbances. 展开更多
关键词 Automatic Load Frequency CONTROLLER Distributed Generation GOVERNOR islanding Detection INITIAL VALUE CROSSING
下载PDF
Modelling and Simulation of Performance of the Microgrid Frequency Stability Control during Unplanned Islanding: The Case Study of Mwenga Hydropower
13
作者 Eligard Kyaruzi Francis Arthur M. Omari John P. John 《Smart Grid and Renewable Energy》 CAS 2022年第7期160-171,共12页
A grid connected microgrid connects to the grid at a point of common coupling. Due to the great inertia of the grid which accelerates and decelerates the generator when its frequency tends to deviate, the grid connect... A grid connected microgrid connects to the grid at a point of common coupling. Due to the great inertia of the grid which accelerates and decelerates the generator when its frequency tends to deviate, the grid connected microgrid operates at a frequency of the infinity bus. Frequency instability is one of the major challenges facing the grid connected microgrid during islanding. The power demand variation causes the variation in rotor speed, resulting to frequency deviation. Frequency can be brought back to standard by varying the power generation to match with the varying load. The performance of the frequency stability control system at Mwenga hydroelectric microgrid has been studied. Through site visitation, the power demand and generation status data were collected and analysed for model preparation. The results of the study indicate that, during islanding, the Mwenga rural electrification project is observed to be subjected to power imbalance which leads to frequency instability. Although the frequency control system tries to keep the system at a nominal frequency by maintaining the continuous balance between generation and varying load demand, however the system still operates with large magnitude of overshoot, undershoot and longer settling time. 展开更多
关键词 MODELLING Frequency Stability Unplanned islanding Mwenga
下载PDF
FRT Control Method Including Islanding Detection in PCS Model for Photovoltaic Generation
14
作者 Miyazaki Takahiro Cheng Wai Tatt Yoshimura Kazuaki Taoka Hisao Kawasaki Shoji Matsuki Junya 《Journal of Energy and Power Engineering》 2013年第7期1388-1393,共6页
The experimental results by the simulated PV (photovoltaic) system for understanding the cause of disconnection when instantaneous voltage sag occurs are reported in this study. Moreover, it is understood that the P... The experimental results by the simulated PV (photovoltaic) system for understanding the cause of disconnection when instantaneous voltage sag occurs are reported in this study. Moreover, it is understood that the PCS with the voltage phase jump detection method which is one of the main causes of the disconnection. We modeled it in the simulation. When fault occurs, even though the residual voltage is more than 20% and the voltage sag time is within 1.0 s, the PCS disconnected by the voltage phase jump detection was confirmed in the simulation results. Ifa large number of PV systems are interconnected in the power system, this study is verified through the simulation that the interaction caused by the disconnection which generated by the voltage phase jump detection. This study is proposed threshold limit value of islanding detection. The validity of proposed method was verified through the simulation in this study. 展开更多
关键词 FRT function PCS islanding detection voltage sag voltage phase jump detection.
下载PDF
Power Electronic Interface with Islanding Detection and Unbalanced Fault Ride-through Capability
15
作者 Nguyen Duc Tuyen Goro Fujita +1 位作者 Toshihisa Funabashi Masakatsu Nomurat 《Journal of Energy and Power Engineering》 2012年第11期1816-1825,共10页
Power electronic interface of dispersed generation plays a very important role in connecting a dispersed generation with utility grids. A power electronic interface not only adjusts the amount of active and reactive p... Power electronic interface of dispersed generation plays a very important role in connecting a dispersed generation with utility grids. A power electronic interface not only adjusts the amount of active and reactive power injecting into a grid but also implements other importance duties as well. In this study, negative-sequence current injection has been fulfilled in three-phase power electronic interface for two important duties besides injecting reference power into utility grids. The first one is for islanding detection, and the other one is to enhance unbalance-fault ride-through capability of dispersed generation. This paper introduces a mechanism of negative-sequence injection based on controlling two separate coordinates of dq-control and explains the effect of negative-sequence injection in limiting the unbalanced currents generated from a dispersed generation. Using adaptive notch filter as a signal processing unit for the three-phase system, negative-sequence components are observed. The performance of entire control system is evaluated by time domain simulations, PSCAD/EMTDC (power systems computer aided design/electromagnetic transients including DC). 展开更多
关键词 Dispersed generation islanding detection negative-sequence components ride-through.
下载PDF
Fault Identification and Islanding in DC Grid Connected PV System
16
作者 M. Mano Raja Paul R. Mahalakshmi +2 位作者 Murugesan Karuppasamypandiyan Ananthan Bhuvanesh Rajendran Jai Ganesh 《Circuits and Systems》 2016年第10期2904-2915,共12页
Nowadays, the DC distribution system has been suggested, as a replacement for the AC power distribution system with electric propulsion. This idea signifies a fresh approach of issuing energy for low-voltage installat... Nowadays, the DC distribution system has been suggested, as a replacement for the AC power distribution system with electric propulsion. This idea signifies a fresh approach of issuing energy for low-voltage installations. It can be used for any electrical application up to 20 MW and works at a nominal voltage of 1000 V DC. The DC distribution system is just an extension of the multiple DC links that previously available in all propulsion and thruster drives, which typically comprise more than 80% of the electrical power consumption on electric propulsion vessels. A fault detection and islanding scheme for DC grid connected PV system is presented in this paper. Unlike traditional ac distribution systems, protection has been challenging for dc systems. The goals of this paper are to classify and detect the fault in the PV system as well as DC grid and to isolate the faulted section so that the system keeps operating without disabling the entire system. The results show the measured values of power at PV panel and DC grid side under different fault condition, which indicates the type of fault that occurs in the system. 展开更多
关键词 PV System DC Grid Fault Identification islanding
下载PDF
Adaptive Islanding Strategy of Sustainable Distribution System for Post-restoration Failures 被引量:2
17
作者 Qifang Chen Kaka Sanaullah +3 位作者 Ammar Tahir Mazhar Hussain Ali Raza Meer Mingchao Xia 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2023年第4期1517-1531,共15页
The power system is susceptible to failures,and further interruptions by subsequent outages which may cause extended events in the formed island.Most of the literature reviewed has focused on island formation after th... The power system is susceptible to failures,and further interruptions by subsequent outages which may cause extended events in the formed island.Most of the literature reviewed has focused on island formation after the disconnection of the main grid supply.However,there is still a need to analyze the post-restoration failures to improve the resilience and minimize the pro-longed disconnection of priority customers.The current research investigates the behavior of islanding schemes under secondary collapses and provides an adaptive solution to withstand such severities.A new total active critical node finding methodology is presented which eases the rearrangement of the initially formed island when affected by multiple faults or DG failures.The concept of single islanding with the coordination of multiple DGs is also discussed,in which the DG's power-sharing capacity is not confined to the boundaries of only particular islands.An economic plan is also proposed to select the controlled type DGs to reduce the overall cost of generation by reducing fuel cost.To evaluate the network's effectiveness and robustness,the proposed adaptive method is deployed on an updated IEEE 69-bus distribution system.Index Terms-Active distribution network,distributed generation,multi-objective,post-restoration,single islanding. 展开更多
关键词 Active distribution network distributed generation multi-objective post-restoration single islanding.
原文传递
Risk-constrained Energy Management Strategy for a Commercial Campus Considering Comprehensive Reserves Against Islanding Conditions
18
作者 Zheming Liang Desong Bian +1 位作者 Xiaohu Zhang Di Shi 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2023年第5期1797-1807,共11页
This paper proposes an optimal risk-constrained energy management strategy for commercial buildings in a commercial campus with islanding capabilities.The goal is to minimize the total operation and maintenance costs,... This paper proposes an optimal risk-constrained energy management strategy for commercial buildings in a commercial campus with islanding capabilities.The goal is to minimize the total operation and maintenance costs,while maximizing comprehensive comfort levels for the occupants.A two-stage riskconstrained,scenario-based stochastic optimization approach is adopted to handle various uncertainties associated with the energy management process,such as power generation of rooftop solar panels,arrival state-of-charges,and arrival/departure time of plug-in electric vehicles,intermittent load demand,and uncertain grid-connection conditions.A conditional-valueat-risk method is introduced to provide a risk-averse energy management strategy.To face the challenge of both reducing the computational burden and maintaining the accuracy of the stochastic programming,an advanced scenario reduction method is leveraged.Extensive simulation results validate the effectiveness of the proposed energy management strategy for minimizing total operating and maintenance costs of commercial buildings with islanding capabilities,while maximizing comprehensive comfort levels of the occupants. 展开更多
关键词 Comprehensive comfort levels CVAR energy management islanding capability RESERVE stochastic programming uncertainty
原文传递
A new technique for islanding operation of distribution network connected with mini hydro
19
作者 J.A.LAGHARI H.MOKHLIS +2 位作者 M.KARIMI A.H.A.BAKAR Hasmaini MOHAMAD 《Frontiers of Information Technology & Electronic Engineering》 SCIE EI CSCD 2015年第5期418-427,共10页
An islanding operation of a distribution network is a topic of interest due to the significant penetration of distributed generation(DG) in a power system network. However, controlling the frequency of an islanded dis... An islanding operation of a distribution network is a topic of interest due to the significant penetration of distributed generation(DG) in a power system network. However, controlling the frequency of an islanded distribution system remains an unresolved issue, especially when the load exceeds the generation. This paper presents a new technique for a successful islanding operation of a distribution network connected with multiple mini hydro based DGs. The proposed technique is based on three main parts. The first part uses an islanding detection technique to detect the islanding event correctly. The second part consists of a power imbalance estimation module(PIEM), which determines the power imbalance between the generation and load demand. The third part consists of a load shedding controller, which receives the power imbalance value and performs load shedding according to load priority. The proposed technique is validated on an 11 k V existing Malaysia distribution network. The simulation results show that the proposed technique is effective in performing a successful islanding operation by shedding a significant number of loads. 展开更多
关键词 islanding operation Mini hydro Distributed generation(DG) islanding detection Load shedding
原文传递
Control of hybrid AC/DC microgrid under islanding operational conditions 被引量:25
20
作者 Guangqian DING Feng GAO +2 位作者 Song ZHANG Poh Chiang LOH Frede BLAABJERG 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2014年第3期223-232,共10页
This paper presents control methods for hybrid AC/DC microgrid under islanding operation condition.The control schemes for AC sub-microgrid and DC sub-microgrid are investigated according to the power sharing requirem... This paper presents control methods for hybrid AC/DC microgrid under islanding operation condition.The control schemes for AC sub-microgrid and DC sub-microgrid are investigated according to the power sharing requirement and operational reliability.In addition,the key control schemes of interlinking converter with DC-link capacitor or energy storage,which will devote to the proper power sharing between AC and DC sub-microgrids to maintain AC and DC side voltage stable,is reviewed.Combining the specific control methods developed for AC and DC sub-microgrids with interlinking converter,the whole hybrid AC/DC microgrid can manage the power flow transferred between sub-microgrids for improving on the operational quality and efficiency. 展开更多
关键词 MICROGRID islanding operation Distributed generation Hybrid AC/DC microgrid INVERTER Power flow
原文传递
上一页 1 2 80 下一页 到第
使用帮助 返回顶部