期刊文献+
共找到168,096篇文章
< 1 2 250 >
每页显示 20 50 100
Clinical feasibility of laparoscopic left lateral segment liver resection with magnetic anchor technique:The first clinical study from China
1
作者 Miao-Miao Zhang Ji-Gang Bai +7 位作者 Dong Zhang Jie Tao Zhi-Min Geng Zhuo-Qun Li Yu-Xiang Ren Yu-HanZhang Yi Lyu Xiao-Peng Yan 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第5期1336-1343,共8页
BACKGROUND Magnetic anchor technique(MAT)has been applied in laparoscopic cholecystectomy and laparoscopic appendectomy,but has not been reported in laparoscopic partial hepatectomy.AIM To evaluate the feasibility of ... BACKGROUND Magnetic anchor technique(MAT)has been applied in laparoscopic cholecystectomy and laparoscopic appendectomy,but has not been reported in laparoscopic partial hepatectomy.AIM To evaluate the feasibility of the MAT in laparoscopic left lateral segment liver resection.METHODS Retrospective analysis was conducted on the clinical data of eight patients who underwent laparoscopic left lateral segment liver resection assisted by MAT in our department from July 2020 to November 2021.The Y-Z magnetic anchor devices(Y-Z MADs)was independently designed and developed by the author of this paper,which consists of the anchor magnet and magnetic grasping apparatus.Surgical time,intraoperative blood loss,intraoperative accidents,operator experience,postoperative incision pain score,postoperative complications,and other indicators were evaluated and analyzed.RESULTS All eight patients underwent a MAT-assisted laparoscopic left lateral segment liver resection,including three patients undertaking conventional 5-port and five patients having a transumbilical single-port operation.The mean operation time was 138±34.32 min(range 95-185 min)and the mean intraoperative blood loss was 123±88.60 mL(range 20-300 mL).No adverse events occurred during the operation.The Y-Z MADs showed good workability and maneuverability in both tissue and organ exposure.In particular,the operators did not experience either a“chopstick”or“sword-fight”effect in the single-port laparoscopic operation.CONCLUSION The results show that the MAT is safe and feasible for laparoscopic left lateral segment liver resection,especially,exhibits its unique abettance for transumbilical single-port laparoscopic left lateral segment liver resection. 展开更多
关键词 magnetosurgery/magnetic surgery magnetic anchor technique Laparoscopic hepatectomy Transumbilical singleport laparoscopy magnet
下载PDF
Unveiling of Terahertz Emission from Ultrafast Demagnetization and the Anomalous Hall Effect in a Single Ferromagnetic Film 被引量:2
2
作者 蓝志强 李章顺 +4 位作者 徐浩然 刘凡 金钻明 彭滟 朱亦鸣 《Chinese Physics Letters》 SCIE EI CAS CSCD 2024年第4期45-50,共6页
Using THz emission spectroscopy,we investigate the elementary spin dynamics in ferromagnetic single-layer Fe on a sub-picosecond timescale.We demonstrate that THz radiation changes its polarity with reversal of the ma... Using THz emission spectroscopy,we investigate the elementary spin dynamics in ferromagnetic single-layer Fe on a sub-picosecond timescale.We demonstrate that THz radiation changes its polarity with reversal of the magnetization applied by the external magnetic field.In addition,it is found that the sign of THz polarity excited from different sides is defined by the thickness of the Fe layer and Fe/dielectric interface.Based on the thickness and symmetry dependences of THz emission,we experimentally distinguish between the two major contributions:ultrafast demagnetization and the anomalous Hall effect.Our experimental results not only enrich understanding of THz electromagnetic generation induced by femtosecond laser pulses but also provide a practical way to access laser-induced ultrafast spin dynamics in magnetic structures. 展开更多
关键词 magnetic magnetIZATION polarity
原文传递
Contribution of glial cells to the neuroprotective effects triggered by repetitive magnetic stimulation:a systematic review 被引量:1
3
作者 Susana A.Ferreira Nuno Pinto +2 位作者 Inês Serrenho Maria Vaz Pato Graça Baltazar 《Neural Regeneration Research》 SCIE CAS CSCD 2024年第1期116-123,共8页
Repetitive transcranial magnetic stimulation has been increasingly studied in different neurological diseases,and although most studies focus on its effects on neuronal cells,the contribution of nonneuronal cells to t... Repetitive transcranial magnetic stimulation has been increasingly studied in different neurological diseases,and although most studies focus on its effects on neuronal cells,the contribution of nonneuronal cells to the improvement trigge red by repetitive transcranial magnetic stimulation in these diseases has been increasingly suggested.To systematically review the effects of repetitive magnetic stimulation on non-neuronal cells two online databases.Web of Science and PubMed were searched fo r the effects of high-frequency-repetitive transcranial magnetic stimulation,low-frequencyrepetitive transcranial magnetic stimulation,intermittent theta-bu rst stimulation,continuous thetaburst stimulation,or repetitive magnetic stimulation on non-neuronal cells in models of disease and in unlesioned animals or cells.A total of 52 studies were included.The protocol more frequently used was high-frequency-repetitive magnetic stimulation,and in models of disease,most studies report that high-frequency-repetitive magnetic stimulation led to a decrease in astrocyte and mic roglial reactivity,a decrease in the release of pro-inflammatory cyto kines,and an increase of oligodendrocyte proliferation.The trend towards decreased microglial and astrocyte reactivity as well as increased oligodendrocyte proliferation occurred with intermittent theta-burst stimulation and continuous theta-burst stimulation.Few papers analyzed the low-frequency-repetitive transcranial magnetic stimulation protocol,and the parameters evaluated were restricted to the study of astrocyte reactivity and release of pro-inflammatory cytokines,repo rting the absence of effects on these paramete rs.In what concerns the use of magnetic stimulation in unlesioned animals or cells,most articles on all four types of stimulation reported a lack of effects.It is also important to point out that the studies were developed mostly in male rodents,not evaluating possible diffe rential effects of repetitive transcranial magnetic stimulation between sexes.This systematic review supports that thro ugh modulation of glial cells repetitive magnetic stimulation contributes to the neuroprotection or repair in various neurological disease models.Howeve r,it should be noted that there are still few articles focusing on the impact of repetitive magnetic stimulation on non-neuronal cells and most studies did not perform in-depth analyses of the effects,emphasizing the need for more studies in this field. 展开更多
关键词 ASTROCYTE GLIA high-frequency repetitive magnetic stimulation inflammation low-frequency repetitive magnetic stimulation MICROGLIA neurologic disorders OLIGODENDROCYTE repetitive magnetic stimulation theta-burst stimulation
下载PDF
Laboratory observation of electron energy distribution near three-dimensional magnetic nulls 被引量:1
4
作者 何任川 徐田超 +7 位作者 杨肖易 肖池阶 张祖煜 袁瑞鑫 王晓钢 郭志彬 余修铭 盖跃 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第3期46-52,共7页
The acceleration of electrons near three-dimensional(3D)magnetic nulls is crucial to the energy conversion mechanism in the 3D magnetic reconnection process.To explore electron acceleration in a 3D magnetic null topol... The acceleration of electrons near three-dimensional(3D)magnetic nulls is crucial to the energy conversion mechanism in the 3D magnetic reconnection process.To explore electron acceleration in a 3D magnetic null topology,we constructed a pair of 3D magnetic nulls in the PKU Plasma Test(PPT)device and observed acceleration of electrons near magnetic nulls.This study measured the plasma floating potential and ion density profiles around the 3D magnetic null.The potential wells near nulls may be related to the energy variations of electrons,so we measured the electron distribution functions(EDFs)at different spatial positions.The axial variation of EDF shows that the electrons deviate from the Maxwell distribution near magnetic nulls.With scanning probes that can directionally measure and theoretically analyze based on curve fitting,the variations of EDFs are linked to the changes of plasma potential under 3D magnetic null topology.The kinetic energy of electrons accelerated by the electric field is 6 eV(v_(e)~7v_(Alfvén-e))and the scale of the region where accelerating electrons exist is in the order of serval electron skin depths. 展开更多
关键词 electron acceleration EEDF 3D magnetic null magnetic reconnection
下载PDF
Toward understanding the microstructure characteristics,phase selection and magnetic properties of laser additive manufactured Nd-Fe-B permanent magnets 被引量:1
5
作者 Bo Yao Nan Kang +6 位作者 Xiangyu Li Dou Li Mohamed EL Mansori Jing Chen Haiou Yang Hua Tan Xin Lin 《International Journal of Extreme Manufacturing》 SCIE EI CAS CSCD 2024年第1期277-294,共18页
Nd-Fe-B permanent magnets play a crucial role in energy conversion and electronic devices.The essential magnetic properties of Nd-Fe-B magnets,particularly coercivity and remanent magnetization,are significantly infue... Nd-Fe-B permanent magnets play a crucial role in energy conversion and electronic devices.The essential magnetic properties of Nd-Fe-B magnets,particularly coercivity and remanent magnetization,are significantly infuenced by the phase characteristics and microstructure.In this work,Nd-Fe-B magnets were manufactured using vacuum induction melting(VIM),laser directed energy deposition(LDED)and laser powder bed fusion(LPBF)technologies.Themicrostructure evolution and phase selection of Nd-Fe-B magnets were then clarified in detail.The results indicated that the solidification velocity(V)and cooling rate(R)are key factors in the phase selection.In terms of the VIM-casting Nd-Fe-B magnet,a large volume fraction of theα-Fe soft magnetic phase(39.7 vol.%)and Nd2Fe17Bxmetastable phase(34.7 vol.%)areformed due to the low R(2.3×10-1?C s-1),whereas only a minor fraction of the Nd2Fe14B hard magnetic phase(5.15 vol.%)is presented.For the LDED-processed Nd-Fe-B deposit,although the Nd2Fe14B hard magnetic phase also had a low value(3.4 vol.%)as the values of V(<10-2m s-1)and R(5.06×103?C s-1)increased,part of theα-Fe soft magnetic phase(31.7vol.%)is suppressed,and a higher volume of Nd2Fe17Bxmetastable phases(47.5 vol.%)areformed.As a result,both the VIM-casting and LDED-processed Nd-Fe-B deposits exhibited poor magnetic properties.In contrast,employing the high values of V(>10-2m s-1)and R(1.45×106?C s-1)in the LPBF process resulted in the substantial formation of the Nd2Fe14B hard magnetic phase(55.8 vol.%)directly from the liquid,while theα-Fe soft magnetic phase and Nd2Fe17Bxmetastable phase precipitation are suppressed in the LPBF-processed Nd-Fe-B magnet.Additionally,crystallographic texture analysis reveals that the LPBF-processedNd-Fe-B magnets exhibit isotropic magnetic characteristics.Consequently,the LPBF-processed Nd-Fe-B deposit,exhibiting a coercivity of 656 k A m-1,remanence of 0.79 T and maximum energy product of 71.5 k J m-3,achieved an acceptable magnetic performance,comparable to other additive manufacturing processed Nd-Fe-B magnets from MQP(Nd-lean)Nd-Fe-Bpowder. 展开更多
关键词 laser additive manufacturing(LAM) Nd-Fe-B permanent magnets numerical simulation microstructure magnetic properties
下载PDF
Staging liver fibrosis with various diffusion-weighted magnetic resonance imaging models 被引量:1
6
作者 Yan-Li Jiang Juan Li +6 位作者 Peng-Fei Zhang Feng-Xian Fan Jie Zou Pin Yang Peng-Fei Wang Shao-Yu Wang Jing Zhang 《World Journal of Gastroenterology》 SCIE CAS 2024年第9期1164-1176,共13页
BACKGROUND Diffusion-weighted imaging(DWI)has been developed to stage liver fibrosis.However,its diagnostic performance is inconsistent among studies.Therefore,it is worth studying the diagnostic value of various diff... BACKGROUND Diffusion-weighted imaging(DWI)has been developed to stage liver fibrosis.However,its diagnostic performance is inconsistent among studies.Therefore,it is worth studying the diagnostic value of various diffusion models for liver fibrosis in one cohort.AIM To evaluate the clinical potential of six diffusion-weighted models in liver fibrosis staging and compare their diagnostic performances.METHODS This prospective study enrolled 59 patients suspected of liver disease and scheduled for liver biopsy and 17 healthy participants.All participants underwent multi-b value DWI.The main DWI-derived parameters included Mono-apparent diffusion coefficient(ADC)from mono-exponential DWI,intravoxel incoherent motion model-derived true diffusion coefficient(IVIM-D),diffusion kurtosis imaging-derived apparent diffusivity(DKI-MD),stretched exponential model-derived distributed diffusion coefficient(SEM-DDC),fractional order calculus(FROC)model-derived diffusion coefficient(FROC-D)and FROC model-derived microstructural quantity(FROC-μ),and continuous-time random-walk(CTRW)model-derived anomalous diffusion coefficient(CTRW-D)and CTRW model-derived temporal diffusion heterogeneity index(CTRW-α).The correlations between DWI-derived parameters and fibrosis stages and the parameters’diagnostic efficacy in detecting significant fibrosis(SF)were assessed and compared.RESULTS CTRW-D(r=-0.356),CTRW-α(r=-0.297),DKI-MD(r=-0.297),FROC-D(r=-0.350),FROC-μ(r=-0.321),IVIM-D(r=-0.251),Mono-ADC(r=-0.362),and SEM-DDC(r=-0.263)were significantly correlated with fibrosis stages.The areas under the ROC curves(AUCs)of the combined index of the six models for distinguishing SF(0.697-0.747)were higher than each of the parameters alone(0.524-0.719).The DWI models’ability to detect SF was similar.The combined index of CTRW model parameters had the highest AUC(0.747).CONCLUSION The DWI models were similarly valuable in distinguishing SF in patients with liver disease.The combined index of CTRW parameters had the highest AUC. 展开更多
关键词 Liver fibrosis magnetic resonance imaging Diffusion-weighted magnetic resonance Liver biopsy Significant fibrosis
下载PDF
Preoperative prediction of perineural invasion of rectal cancer based on a magnetic resonance imaging radiomics model:A dual-center study 被引量:2
7
作者 Yan Liu Bai-Jin-Tao Sun +3 位作者 Chuan Zhang Bing Li Xiao-Xuan Yu Yong Du 《World Journal of Gastroenterology》 SCIE CAS 2024年第16期2233-2248,共16页
BACKGROUND Perineural invasion(PNI)has been used as an important pathological indicator and independent prognostic factor for patients with rectal cancer(RC).Preoperative prediction of PNI status is helpful for indivi... BACKGROUND Perineural invasion(PNI)has been used as an important pathological indicator and independent prognostic factor for patients with rectal cancer(RC).Preoperative prediction of PNI status is helpful for individualized treatment of RC.Recently,several radiomics studies have been used to predict the PNI status in RC,demonstrating a good predictive effect,but the results lacked generalizability.The preoperative prediction of PNI status is still challenging and needs further study.AIM To establish and validate an optimal radiomics model for predicting PNI status preoperatively in RC patients.METHODS This retrospective study enrolled 244 postoperative patients with pathologically confirmed RC from two independent centers.The patients underwent preoperative high-resolution magnetic resonance imaging(MRI)between May 2019 and August 2022.Quantitative radiomics features were extracted and selected from oblique axial T2-weighted imaging(T2WI)and contrast-enhanced T1WI(T1CE)sequences.The radiomics signatures were constructed using logistic regression analysis and the predictive potential of various sequences was compared(T2WI,T1CE and T2WI+T1CE fusion sequences).A clinical-radiomics(CR)model was established by combining the radiomics features and clinical risk factors.The internal and external validation groups were used to validate the proposed models.The area under the receiver operating characteristic curve(AUC),DeLong test,net reclassification improvement(NRI),integrated discrimination improvement(IDI),calibration curve,and decision curve analysis(DCA)were used to evaluate the model performance.RESULTS Among the radiomics models,the T2WI+T1CE fusion sequences model showed the best predictive performance,in the training and internal validation groups,the AUCs of the fusion sequence model were 0.839[95%confidence interval(CI):0.757-0.921]and 0.787(95%CI:0.650-0.923),which were higher than those of the T2WI and T1CE sequence models.The CR model constructed by combining clinical risk factors had the best predictive performance.In the training and internal and external validation groups,the AUCs of the CR model were 0.889(95%CI:0.824-0.954),0.889(95%CI:0.803-0.976)and 0.894(95%CI:0.814-0.974).Delong test,NRI,and IDI showed that the CR model had significant differences from other models(P<0.05).Calibration curves demonstrated good agreement,and DCA revealed significant benefits of the CR model.CONCLUSION The CR model based on preoperative MRI radiomics features and clinical risk factors can preoperatively predict the PNI status of RC noninvasively,which facilitates individualized treatment of RC patients. 展开更多
关键词 Rectal cancer Perineural invasion magnetic resonance imaging Radiomics NOMOGRAM
下载PDF
Simulation of the SMILE Soft X-ray Imager response to a southward interplanetary magnetic field turning 被引量:1
8
作者 Andrey Samsonov Graziella Branduardi-Raymont +3 位作者 Steven Sembay Andrew Read David Sibeck Lutz Rastaetter 《Earth and Planetary Physics》 EI CSCD 2024年第1期39-46,共8页
The Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)Soft X-ray Imager(SXI)will shine a spotlight on magnetopause dynamics during magnetic reconnection.We simulate an event with a southward interplanetary magne... The Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)Soft X-ray Imager(SXI)will shine a spotlight on magnetopause dynamics during magnetic reconnection.We simulate an event with a southward interplanetary magnetic field turning and produce SXI count maps with a 5-minute integration time.By making assumptions about the magnetopause shape,we find the magnetopause standoff distance from the count maps and compare it with the one obtained directly from the magnetohydrodynamic(MHD)simulation.The root mean square deviations between the reconstructed and MHD standoff distances do not exceed 0.2 RE(Earth radius)and the maximal difference equals 0.24 RE during the 25-minute interval around the southward turning. 展开更多
关键词 magnetOPAUSE magnetic reconnection solar wind charge exchange southward interplanetary magnetic field numerical modeling Solar wind magnetosphere Ionosphere Link Explorer(SMILE) Soft X-ray Imager
下载PDF
Numerical Analysis of the Magnetic Dipole Effect on a Radiative Ferromagnetic Liquid Flowing over a Porous Stretched Sheet 被引量:1
9
作者 G.Dharmaiah F.Mebarek-Oudina +1 位作者 K.S.Balamurugan N.Vedavathi 《Fluid Dynamics & Materials Processing》 EI 2024年第2期293-310,共18页
The effects of a magnetic dipole on a nonlinear thermally radiative ferromagnetic liquidflowing over a stretched surface in the presence of Brownian motion and thermophoresis are investigated.By means of a similarity t... The effects of a magnetic dipole on a nonlinear thermally radiative ferromagnetic liquidflowing over a stretched surface in the presence of Brownian motion and thermophoresis are investigated.By means of a similarity transformation,ordinary differential equations are derived and solved afterwards using a numerical(the BVP4C)method.The impact of various parameters,namely the velocity,temperature,concentration,is presented graphically.It is shown that the nanoparticles properties,in conjunction with the magnetic dipole effect,can increase the thermal conductivity of the engineered nanofluid and,consequently,the heat transfer.Comparison with earlier studies indicates high accuracy and effectiveness of the numerical approach.An increase in the Brow-nian motion parameter and thermophoresis parameter enhances the concentration and the related boundary layer.The skin-friction rises when the viscosity parameter is increased.A larger value of the ferromagnetic para-meter results in a higher skin-friction and,vice versa,in a smaller Nusselt number. 展开更多
关键词 Brownian motion thermo-phoresis radiation magnetic dipole BVP4C NON-LINEAR
下载PDF
Y–Z deformable magnetic ring for the treatment of rectal stricture: A case report and review of literature
10
作者 Miao-Miao Zhang Huan-Chen Sha +2 位作者 Yuan-Fa Qin Yi Lyu Xiao-Peng Yan 《World Journal of Gastroenterology》 SCIE CAS 2024年第6期599-606,共8页
BACKGROUND Treatment of postoperative anastomotic stenosis for colorectal cancer is often challenging,especially for patients who do not respond well to endoscopy.In cases where patients have undergone an enterostomy,... BACKGROUND Treatment of postoperative anastomotic stenosis for colorectal cancer is often challenging,especially for patients who do not respond well to endoscopy.In cases where patients have undergone an enterostomy,the stenosis can be easily resolved through magnetic compression.However,common magnetic compre-ssion techniques cannot be performed on those without enterostomy.We design-ed a novel Y–Z deformable magnetic ring(Y–Z DMR)and successfully applied it to a patient with a stenosis rectal anastomosis and without enterostomy after rectal cancer surgery.CASE SUMMARY We here report the case of a 57-year-old woman who had undergone a laparo-scopic radical rectum resection(Dixon)for rectal cancer.However,she started facing difficulty in defecation 6 months after surgery.Her colonoscopy indicated stenosis of the rectal anastomosis.Endoscopic balloon dilation was performed six times on her.However,the stenosis still showed a trend of gradual aggravation.Because the patient did not undergo an enterostomy,the conventional endoscopic magnetic compression technique could not be performed.Hence,we imple-mented a Y–Z DMR implemented through the anus under single channel.The magnetic ring fell off nine days after the operation and the rectal stenosis was relieved.The patient was followed up for six months and reported good defeca-tion.CONCLUSION The Y–Z DMR deformable magnetic ring is an excellent treatment strategy for patients with rectal stenosis and without enterostomy. 展开更多
关键词 Anastomotic stenosis Colorectal cancer magnetosurgery magnetic compression technique magnetic surgery clinic Case report
下载PDF
Magnetic resonance imaging of extraocular rectus muscles abnormalities in acute acquired concomitant esotropia 被引量:1
11
作者 Jia-Yu Chen Li-Rong Zhang +5 位作者 Jia-Wen Liu Jie Hao Hui-Xin Li Qiong-Yue Zhang Zhao-Hui Liu Jing Fu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第1期119-125,共7页
AIM:To investigate the difference of medial rectus(MR)and lateral rectus(LR)between acute acquired concomitant esotropia(AACE)and the healthy controls(HCs)detected by magnetic resonance imaging(MRI).METHODS:A case-con... AIM:To investigate the difference of medial rectus(MR)and lateral rectus(LR)between acute acquired concomitant esotropia(AACE)and the healthy controls(HCs)detected by magnetic resonance imaging(MRI).METHODS:A case-control study.Eighteen subjects with AACE and eighteen HCs were enrolled.MRI scanning data were conducted in target-controlled central gaze with a 3-Tesla magnetic resonance scanner.Extraocular muscles(EOMs)were scanned in contiguous image planes 2-mm thick spanning the EOM origins to the globe equator.To form posterior partial volumes(PPVs),the LR and MR cross-sections in the image planes 8,10,12,and 14 mm posterior to the globe were summed and multiplied by the 2-mm slice thickness.The data were classified according to the right eye,left eye,dominant eye,and non-dominant eye,and the differences in mean cross-sectional area,maximum cross-sectional area,and PPVs of the MR and LR muscle in the AACE group and HCs group were compared under the above classifications respectively.RESULTS:There were no significant differences between the two groups of demographic characteristics.The mean cross-sectional area of the LR muscle was significantly greater in the AACE group than that in the HCs group in the non-dominant eyes(P=0.028).The maximum cross-sectional area of the LR muscle both in the dominant and non-dominant eye of the AACE group was significantly greater than the HCs group(P=0.009,P=0.016).For the dominant eye,the PPVs of the LR muscle were significantly greater in the AACE than that in the HCs group(P=0.013),but not in the MR muscle(P=0.698).CONCLUSION:The size and volume of muscles dominant eyes of AACE subjects change significantly to overcome binocular diplopia.The LR muscle become larger to compensate for the enhanced convergence in the AACE. 展开更多
关键词 acute acquired concomitant esotropia magnetic resonance imaging extraocular muscles
原文传递
Influence of different magnetic forces on the effect of colonic anastomosis in rats
12
作者 Bo-Yan Tian Miao-Miao Zhang +2 位作者 Jia Ma Yi Lyu Xiao-Peng Yan 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第3期860-870,共11页
BACKGROUND Despite much work having been conducted on magnetic compression anastomo-sis(MCA)in the digestive tract,there are no reports on the influence of magnetic force on the anastomosis.AIM To investigate the effe... BACKGROUND Despite much work having been conducted on magnetic compression anastomo-sis(MCA)in the digestive tract,there are no reports on the influence of magnetic force on the anastomosis.AIM To investigate the effect of different magnetic force magnets on the MCA of the digestive tract.METHODS Two groups of magnets of the same sizes but different magnetic forces were designed and produced.A total of 24 Sprague-Dawley rats were randomly assigned into two groups(powerful magnet group and common magnet group),with 12 rats in each group.Two types of magnets were used to complete the colonic side-to-side anastomosis of the rats.The operation time and magnet discharge time were recorded.The anastomotic specimens were obtained 4 wk after the operation and then the burst pressure and diameter of the anastomosis were measured,and the anastomosis was observed via the naked eye and subjected to histological examination.RESULTS The magnetic forces of the powerful and common magnet groups at zero distance were 8.26 N and 4.10 N,respectively.The colonic side-to-side anastomosis was completed in all 24 rats,and the operation success rate and postoperative survival rate were 100%.No significant difference was noted in the operation time between the two groups.The magnet discharge time of the powerful magnet group was slightly longer than that of the common magnet group,but the difference was not statistically significant(P=0.513).Furthermore,there was no statistical difference in the burst pressure(P=0.266)or diameter of magnetic anastomosis(P=0.095)between the two groups.The gross specimens of the two groups showed good anastomotic healing,and histological observation indicated good mucosal continuity without differences on healing.CONCLUSION In the rat colonic side-to-side MCA model,both the powerful magnet with 8.26 N and the common magnet with 4.10 N showed no significant impact on the anastomosis establishment process or its effect. 展开更多
关键词 magnetosurgery magnetic compression anastomosis Colonic anastomosis magnetic force RATS
下载PDF
Magnetic compression anastomosis to restore biliary tract continuity after obstruction following major abdominal trauma:A case report
13
作者 Miao-Miao Zhang Jie Tao +7 位作者 Huan-Chen Sha Yun Li Xiao-Gang Song Oliver J Muensterer Fang-Fang Dong Li Zhang Yi Lyu Xiao-Peng Yan 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第6期1933-1938,共6页
BACKGROUND The combination of magnetic compression anastomosis(MCA)and endoscopy has been used to treat biliary stricture after liver transplantation.However,its use for the treatment of complex biliary obstruction af... BACKGROUND The combination of magnetic compression anastomosis(MCA)and endoscopy has been used to treat biliary stricture after liver transplantation.However,its use for the treatment of complex biliary obstruction after major abdominal trauma has not been reported.This case report describes the successful use of MCA for the treatment of biliary obstruction resulting from major abdominal trauma.A 23-year-old man underwent major abdominal surgery(repair of liver rupture,right half colon resection,and ileostomy)following a car accident one year ago.The abdominal drainage tube,positioned at the Winslow foramen,was draining approximately 600-800 mL of bile per day.During the two endoscopic retrograde cholangiopancreatography procedures,the guide wire was unable to enter the common bile duct,which prevented placement of a biliary stent.MCA combined with endoscopy was used to successfully achieve magnetic anastomosis of the peritoneal sinus tract and duodenum,and then a choledochoduodenal stent was placed.Finally,the external biliary drainage tube was removed.The patient achieved internal biliary drainage leading to the removal of the external biliary drainage tube,which improved the quality of life.CONCLUSION Magnetic compression technique can be used for the treatment of complex biliary obstruction with minimal operative trauma. 展开更多
关键词 magnetic compression anastomosis magnetosurgery Endoscopy magnetic Surgery Clinic Biliary obstruction Case report
下载PDF
Novel magnetic compression technique for the treatment of postoperative anastomotic stenosis in rectal cancer:A case report
14
作者 Miao-Miao Zhang Huan-Chen Sha +9 位作者 Hai-Rong Xue Yuan-Fa Qin Xiao-Gang Song Yun Li Yu Li Zheng-Wu Deng Yu-Lin Gao Fang-Fang Dong Yi Lyu Xiao-Peng Yan 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第6期1926-1932,共7页
BACKGROUND The treatment of postoperative anastomotic stenosis after excision of rectal cancer is challenging.Endoscopic balloon dilation and radial incision are not effective in all patients.We present a new endoscop... BACKGROUND The treatment of postoperative anastomotic stenosis after excision of rectal cancer is challenging.Endoscopic balloon dilation and radial incision are not effective in all patients.We present a new endoscopy-assisted magnetic compression technique(MCT)for the treatment of rectal anastomotic stenosis.We successfully applied this MCT to a patient who developed an anastomotic stricture after radical resection of rectal cancer.A 50-year-old man had undergone laparoscopic radical rectal cancer surgery at a local hospital 5 months ago.A colonoscopy performed 2 months ago indicated that the rectal anastomosis was narrow due to which ileostomy closure could not be performed.The patient came to the Magnetic Surgery Clinic of the First Affiliated Hospital of Xi'an Jiaotong University after learning that we had successfully treated patients with colorectal stenosis using MCT.We performed endoscopy-assisted magnetic compression surgery for rectal stenosis.The magnets were removed 16 d later.A follow-up colonoscopy performed after 4 months showed good anastomotic patency,following which,ileostomy closure surgery was performed.CONCLUSION MCT is a simple,non-invasive technique for the treatment of anastomotic stricture after radical resection of rectal cancer.The technique can be widely used in clinical settings. 展开更多
关键词 Rectal cancer magnetic compression technique magnetosurgery Anastomotic stricture magnetic surgery clinic Case report
下载PDF
Semi-analytical investigation of heat transfer in a porous convective radiative moving longitudinal fin exposed to magnetic field in the presence of a shape-dependent trihybrid nanofluid 被引量:1
15
作者 C.G.PAVITHRA B.J.GIREESHA M.L.KEERTHI 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2024年第1期197-216,共20页
The thermal examination of a non-integer-ordered mobile fin with a magnetism in the presence of a trihybrid nanofluid(Fe_3O_4-Au-Zn-blood) is carried out. Three types of nanoparticles, each having a different shape, a... The thermal examination of a non-integer-ordered mobile fin with a magnetism in the presence of a trihybrid nanofluid(Fe_3O_4-Au-Zn-blood) is carried out. Three types of nanoparticles, each having a different shape, are considered. These shapes include spherical(Fe_3O_4), cylindrical(Au), and platelet(Zn) configurations. The combination approach is utilized to evaluate the physical and thermal characteristics of the trihybrid and hybrid nanofluids, excluding the thermal conductivity and dynamic viscosity. These two properties are inferred by means of the interpolation method based on the volume fraction of nanoparticles. The governing equation is transformed into a dimensionless form, and the Adomian decomposition Sumudu transform method(ADSTM) is adopted to solve the conundrum of a moving fin immersed in a trihybrid nanofluid. The obtained results agree well with those numerical simulation results, indicating that this research is reliable. The influence of diverse factors on the thermal overview for varying noninteger values of γ is analyzed and presented in graphical representations. Furthermore, the fluctuations in the heat transfer concerning the pertinent parameters are studied. The results show that the heat flux in the presence of the combination of spherical, cylindrical, and platelet nanoparticles is higher than that in the presence of the combination of only spherical and cylindrical nanoparticles. The temperature at the fin tip increases by 0.705 759% when the value of the Peclet number increases by 400%, while decreases by 11.825 13% when the value of the Hartman number increases by 400%. 展开更多
关键词 convection radiation moving longitudinal fin Adomian decomposition Sumudu transform method(ADSTM) trihybrid nanofluid magnetic field
下载PDF
High-grade pancreatic intraepithelial neoplasia diagnosed based on changes in magnetic resonance cholangiopancreatography findings:A case report 被引量:2
16
作者 Nao Furuya Atsushi Yamaguchi +13 位作者 Naohiro Kato Syuhei Sugata Takuro Hamada Takeshi Mizumoto Yuzuru Tamaru Ryusaku Kusunoki Toshio Kuwai Hirotaka Kouno Kazuya Kuraoka Yoshiyuki Shibata Sho Tazuma Takeshi Sudo Hiroshi Kohno Shiro Oka 《World Journal of Clinical Cases》 SCIE 2024年第8期1487-1496,共10页
BACKGROUND High-grade pancreatic intraepithelial neoplasia(PanIN)exhibits no mass and is not detected by any examination modalities.However,it can be diagnosed by pancreatic juice cytology from indirect findings.Most ... BACKGROUND High-grade pancreatic intraepithelial neoplasia(PanIN)exhibits no mass and is not detected by any examination modalities.However,it can be diagnosed by pancreatic juice cytology from indirect findings.Most previous cases were diagnosed based on findings of a focal stricture of the main pancreatic duct(MPD)and caudal MPD dilatation and subsequent pancreatic juice cytology using endoscopic retrograde cholangiopancreatography(ERCP).We experienced a case of high-grade PanIN with an unclear MPD over a 20-mm range,but without caudal MPD dilatation on magnetic resonance cholangiopancreatography(MRCP).CASE SUMMARY A 60-year-old female patient underwent computed tomography for a follow-up of uterine cancer post-excision,which revealed pancreatic cysts.MRCP revealed an unclear MPD of the pancreatic body at a 20-mm length without caudal MPD dilatation.Thus,course observation was performed.After 24 mo,MRCP revealed an increased caudal MPD caliber and a larger pancreatic cyst.We performed ERCP and detected atypical cells suspected of adenocarcinoma by serial pancreatic juice aspiration cytology examination.We performed a distal pancreatectomy and obtained a histopathological diagnosis of high-grade PanIN.Pancreatic parenchyma invasion was not observed,and curative resection was achieved.CONCLUSION High-grade Pan-IN may cause MPD narrowing in a long range without caudal MPD dilatation. 展开更多
关键词 Pancreatic cancer Pancreatic intraepithelial neoplasm High-grade pancreatic intraepithelial neoplasm magnetic resonance cholangiopancreatography Carcinoma in situ Case report
下载PDF
Outcomes and efficacy of magnetic resonance imaging-compatible sacral nerve stimulator for management of fecal incontinence: A multi-institutional study 被引量:1
17
作者 Binit Katuwal Amy Thorsen +5 位作者 Kunal Kochar Ryba Bhullar Ray King Ernesto Raul Drelichman Vijay K Mittal Jasneet Singh Bhullar 《World Journal of Radiology》 2024年第2期32-39,共8页
BACKGROUND Fecal incontinence(FI)is an involuntary passage of fecal matter which can have a significant impact on a patient’s quality of life.Many modalities of treatment exist for FI.Sacral nerve stimulation is a we... BACKGROUND Fecal incontinence(FI)is an involuntary passage of fecal matter which can have a significant impact on a patient’s quality of life.Many modalities of treatment exist for FI.Sacral nerve stimulation is a well-established treatment for FI.Given the increased need of magnetic resonance imaging(MRI)for diagnostics,the In-terStim which was previously used in sacral nerve stimulation was limited by MRI incompatibility.Medtronic MRI-compatible InterStim was approved by the United States Food and Drug Administration in August 2020 and has been widely used.AIM To evaluate the efficacy,outcomes and complications of the MRI-compatible InterStim.METHODS Data of patients who underwent MRI-compatible Medtronic InterStim placement at UPMC Williamsport,University of Minnesota,Advocate Lutheran General Hospital,and University of Wisconsin-Madison was pooled and analyzed.Patient demographics,clinical features,surgical techniques,complications,and outcomes were analyzed.Strengthening the Reporting of Observational studies in Epidemiology(STROBE)cross-sectional reporting guidelines were used.RESULTS Seventy-three patients had the InterStim implanted.The mean age was 63.29±12.2 years.Fifty-seven(78.1%)patients were females and forty-two(57.5%)patients had diabetes.In addition to incontinence,overlapping symptoms included diarrhea(23.3%),fecal urgency(58.9%),and urinary incontinence(28.8%).Fifteen(20.5%)patients underwent Peripheral Nerve Evaluation before proceeding to definite implant placement.Thirty-two(43.8%)patients underwent rechargeable InterStim placement.Three(4.1%)patients needed removal of the implant.Migration of the external lead connection was observed in 7(9.6%)patients after the stage I procedure.The explanation for one patient was due to infection.Seven(9.6%)patients had other complications like nerve pain,hematoma,infection,lead fracture,and bleeding.The mean follow-up was 6.62±3.5 mo.Sixty-eight(93.2%)patients reported significant improvement of symptoms on follow-up evaluation.CONCLUSION This study shows promising results with significant symptom improvement,good efficacy and good patient outcomes with low complication rates while using MRI compatible InterStim for FI.Further long-term follow-up and future studies with a larger patient population is recommended. 展开更多
关键词 Fecal incontinence Sacral nerve stimulation InterStim magnetic resonance imaging Sacral neuromodulation
下载PDF
Potential applications of 7 Tesla magnetic resonance imaging in paediatric neuroimaging:Feasibility and challenges 被引量:1
18
作者 Arosh S Perera Molligoda Arachchige Letterio S Politi 《World Journal of Clinical Pediatrics》 2024年第2期1-6,共6页
The integration of 7 Tesla magnetic resonance imaging(7 T MRI)in adult patients has marked a revolutionary stride in radiology.In this article we explore the feasibility of 7 T MRI in paediatric practice,emphasizing i... The integration of 7 Tesla magnetic resonance imaging(7 T MRI)in adult patients has marked a revolutionary stride in radiology.In this article we explore the feasibility of 7 T MRI in paediatric practice,emphasizing its feasibility,applications,challenges,and safety considerations.The heightened resolution and tissue contrast of 7 T MRI offer unprecedented diagnostic accuracy,particularly in neuroimaging.Applications range from neuro-oncology to neonatal brain imaging,showcasing its efficacy in detecting subtle structural abnormalities and providing enhanced insights into neurological conditions.Despite the promise,challenges such as high cost,discomfort,and safety concerns necessitate careful consideration.Research suggests that,with precautions,7 T MRI is feasible in paediatrics,yet ongoing studies and safety assessments are imperative. 展开更多
关键词 7 Tesla magnetic resonance imaging Pediatric imaging FEASIBILITY CHALLENGES
下载PDF
Preliminary geological interpretation of long-wavelength magnetic anomalies over China and surrounding regions
19
作者 Jie Wang YanYan Yang +4 位作者 ZhiMa Zeren Jian Wang Xin Wang YuXin Luo XuHui Shen 《Earth and Planetary Physics》 EI CAS CSCD 2024年第3期445-458,共14页
Long-wavelength(>500 km)magnetic anomalies originating in the lithosphere were first found in satellite magnetic surveys.Compared to the striking magnetic anomalies around the world,the long-wavelength magnetic ano... Long-wavelength(>500 km)magnetic anomalies originating in the lithosphere were first found in satellite magnetic surveys.Compared to the striking magnetic anomalies around the world,the long-wavelength magnetic anomalies in China and surrounding regions are relatively weak.Specialized research on each of these anomalies has been quite inadequate;their geological origins remain unclear,in particular their connection to tectonic activity in the Chinese and surrounding regions.We focus on six magnetic high anomalies over the(1)Tarim Basin,(2)Sichuan Basin(3)Great Xing’an Range,(4)Barmer Basin,(5)Central Myanmar Basin,and(6)Sunda and Banda Arcs,and a striking magnetic low anomaly along the southern part of the Himalayan-Tibetan Plateau.We have analyzed their geological origins by reviewing related research and by detailed comparison with geological results.The tectonic backgrounds for these anomalies belong to two cases:either ancient basin basement,or subduction-collision zone.However,the geological origins of large-scale regional magnetic anomalies are always subject to dispute,mainly because of limited surface exposure of sources,later tectonic destruction,and superposition of multi-phase events. 展开更多
关键词 long-wavelength magnetic anomaly lithospheric magnetic anomaly lithospheric magnetic field model satellite magnetic survey CSES
下载PDF
High-frequency repetitive transcranial magnetic stimulation promotes neural stem cell proliferation after ischemic stroke 被引量:3
20
作者 Jing Luo Yuan Feng +4 位作者 Zhongqiu Hong Mingyu Yin Haiqing Zheng Liying Zhang Xiquan Hu 《Neural Regeneration Research》 SCIE CAS CSCD 2024年第8期1772-1780,共9页
Prolife ration of neural stem cells is crucial for promoting neuronal regeneration and repairing cerebral infarction damage.Transcranial magnetic stimulation(TMS)has recently emerged as a tool for inducing endogenous ... Prolife ration of neural stem cells is crucial for promoting neuronal regeneration and repairing cerebral infarction damage.Transcranial magnetic stimulation(TMS)has recently emerged as a tool for inducing endogenous neural stem cell regeneration,but its underlying mechanisms remain unclea r In this study,we found that repetitive TMS effectively promotes the proliferation of oxygen-glucose deprived neural stem cells.Additionally,repetitive TMS reduced the volume of cerebral infa rction in a rat model of ischemic stro ke caused by middle cerebral artery occlusion,im p roved rat cognitive function,and promoted the proliferation of neural stem cells in the ischemic penumbra.RNA-sequencing found that repetitive TMS activated the Wnt signaling pathway in the ischemic penumbra of rats with cerebral ischemia.Furthermore,PCR analysis revealed that repetitive TMS promoted AKT phosphorylation,leading to an increase in mRNA levels of cell cycle-related proteins such as Cdk2 and Cdk4.This effect was also associated with activation of the glycogen synthase kinase 3β/β-catenin signaling pathway,which ultimately promotes the prolife ration of neural stem cells.Subsequently,we validated the effect of repetitive TMS on AKT phosphorylation.We found that repetitive TMS promoted Ca2+influx into neural stem cells by activating the P2 calcium channel/calmodulin pathway,thereby promoting AKT phosphorylation and activating the glycogen synthase kinase 3β/β-catenin pathway.These findings indicate that repetitive TMS can promote the proliferation of endogenous neural stem cells through a Ca2+influx-dependent phosphorylated AKT/glycogen synthase kinase 3β/β-catenin signaling pathway.This study has produced pioneering res ults on the intrinsic mechanism of repetitive TMS to promote neural function recove ry after ischemic stro ke.These results provide a stro ng scientific foundation for the clinical application of repetitive TMS.Moreover,repetitive TMS treatment may not only be an efficient and potential approach to support neurogenesis for further therapeutic applications,but also provide an effective platform for the expansion of neural stem cells. 展开更多
关键词 AKT/β-catenin signaling brain stimulation Ca2+influx cell proliferation ischemic stroke middle cerebral artery occlusion neural stem cells neurological rehabilitation repetitive transcranial magnetic stimulation
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部