Development of a portable reflectance confocal microscope and its application in the noninvasive in vivo evaluation of mesenchymal stem cell-promoted cutaneous wound healing
1
作者 Lixing Zhang Xin Miao +6 位作者 Meijia Wang Aihua Shi Jingwen Wang Zhonglin Ma Yunhai Zhang Jingzhong Zhang Shuang Yu 《Bio-Design and Manufacturing》 SCIE EI CAS CSCD 2023年第3期268-283,共16页
The process of wound healing is routinely evaluated by histological evaluation in the clinic,which may cause scarring and secondary injury.Reflectance confocal microscopy(RCM)represents a noninvasive,real-time imaging... The process of wound healing is routinely evaluated by histological evaluation in the clinic,which may cause scarring and secondary injury.Reflectance confocal microscopy(RCM)represents a noninvasive,real-time imaging technique that allows in vivo evaluation of the skin.Traditional RCM was wide-probe-based,which limited its application on uneven and covered skin.In this study,we report the development of a portable reflectance confocal microscope(PRCM)in which all components were assembled in a handheld shell.Although the size and weight of the PRCM were reduced based on the use of a microelectromechanical system,the resolution was kept at 0.91μm,and the field of view of the system was 343μm×532μm.When used in vivo,the PRCM was able to visualize cellular and nuclear morphology for both mouse and human skin.PRCM evaluations were then performed on wounds after topically applied mesenchymal stem cells(MSCs)or saline treatment.The PRCM allowed visualization of the formation of collagen bundles,re-epithelization from the wound edge to the wound bed,and hair follicle regeneration,which were consistent with histological evaluations.Therefore,we offer new insights into monitoring the effects of topically applied MSCs on the process of wound healing by using PRCM.This study illustrates that the newly developed PRCM represents a promising device for real-time,noninvasive monitoring of the dynamic process of wound healing,which demonstrates its potential to diagnose,monitor,or predict disease in clinical wound therapy. 展开更多
关键词 Portable reflectance confocal microscope Wound healing Noninvasive optical imaging Real-time in vivo visualization
下载PDF
Comparative Alpha Tracks Counting Using an Optical Microscope and a Spark Counter
2
作者 Dabo S. I. Agba Ponaho Kezo Issa Konaté 《Detection》 2023年第2期7-18,共12页
In the metrology of radon, an environmental lung carcinogen, the integrated measurements necessary for epidemiological studies are made very often using the tracks detector LR 115 type 2. For dosimetric analysis, the ... In the metrology of radon, an environmental lung carcinogen, the integrated measurements necessary for epidemiological studies are made very often using the tracks detector LR 115 type 2. For dosimetric analysis, the etched tracks from radon alpha particles on this detector are usually counted by means of an optical microscope or a spark counter. An optimal reading of the track densities which must be converted into radon concentrations, can’t be done without a good mastery of the mode of operation and use of these devices. Furthermore, investigations to know as to whether or not each of those can be used to determine radon concentration are necessary. These are the objectives of the present work in which LR 115 samples exposed to radon for at least 3 months, were chemically developed under standard conditions and read. The track densities obtained with the microscope are very much higher than those of the counter for each sample. These results are consistent with those published by other authors. However, each of these devices can be used interchangeably for alpha tracks counting, as both provide radon concentrations with a very good linear correlation coefficient of 0.95 taking into account their respective calibration factors for the reading of this detector. In addition, the saturation phenomenon for the spark counter reading of LR 115 detector occurs beyond 11,000 tr/cm<sup>2</sup>, a density never reached during our environmental radon measurements. 展开更多
关键词 LR 115 Detector Optical microscope Spark Counter Alpha Track Density Calibration Factor Radon Concentration
下载PDF
用IM Microscope方法计算无源互调产物
3
作者 王海宁 梁建刚 +1 位作者 王积勤 张晨新 《空军工程大学学报(自然科学版)》 CSCD 北大核心 2005年第3期47-49,共3页
在微波与射频无源互调的研究中,预测无源互调产物的电平是非常重要的。在IM Micro-scope方法的基础上进行了改进,在预测过程中直接引入输入信号经过非线性器件后输出信号的幅度和相位变化模型,给出了详细的数学模型,并实例验证了该方法... 在微波与射频无源互调的研究中,预测无源互调产物的电平是非常重要的。在IM Micro-scope方法的基础上进行了改进,在预测过程中直接引入输入信号经过非线性器件后输出信号的幅度和相位变化模型,给出了详细的数学模型,并实例验证了该方法的正确性。 展开更多
关键词 无源互调(PIM) 无源互调产物(PIMP) IM microscope RF
下载PDF
用IM Microscope方法计算无源互调产物
4
作者 王海宁 梁建刚 +1 位作者 王积勤 张晨新 《弹箭与制导学报》 CSCD 北大核心 2005年第S4期458-460,共3页
在微波与射频无源互调的研究中,预测无源互调产物的电平是非常重要的,因为这样可以直观的看出无源互调噪声对于器件或者系统的影响。在众多的预测方法中,IM Microscope 方法具有很多优点。文中在IM Microscope 方法的基础上进行了改进,... 在微波与射频无源互调的研究中,预测无源互调产物的电平是非常重要的,因为这样可以直观的看出无源互调噪声对于器件或者系统的影响。在众多的预测方法中,IM Microscope 方法具有很多优点。文中在IM Microscope 方法的基础上进行了改进,在预测过程中直接引入输入信号经过非线性器件后输出信号的幅度和相位变化模型,给出了详细的数学模型,这样可以大大减少很多的测量工作。 展开更多
关键词 无源互调(PIM) 无源互调产物(PIMP) IM microscope RF
下载PDF
MicroScope高分辨率成像测井技术及应用
5
作者 夏竹君 张兰江 +2 位作者 张贺举 杨坚 付琛 《海洋石油》 CAS 2019年第1期54-60,共7页
MicroScope随钻高分辨率成像测井技术是斯伦贝谢公司最新推出,能记录超高分辨率电阻率图像UHRI和多个探测深度深钮电阻率成像图,介绍了超高分辨率电阻率成像图UHRI识别岩性及地层结构、识别沉积构造、划分沉积微相、分析古水流与砂体展... MicroScope随钻高分辨率成像测井技术是斯伦贝谢公司最新推出,能记录超高分辨率电阻率图像UHRI和多个探测深度深钮电阻率成像图,介绍了超高分辨率电阻率成像图UHRI识别岩性及地层结构、识别沉积构造、划分沉积微相、分析古水流与砂体展布等的方法,在南海西部沉积相研究方面发挥了重要作用,是值得推广的新型成像测井技术。 展开更多
关键词 microscope 成像测井 沉积相 测井技术 南海西部
下载PDF
MICRO/NANO-MACHINING ON SILICON SURFACE WITH A MODIFIED ATOMIC FORCE MICROSCOPE 被引量:4
6
作者 Zhao Qingliang,Sun Tao,Dong Shen,Liang Yingchun (School of Mechanical Engineering,Harbin Institute of Technology) 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2001年第3期207-211,共5页
To understand the deformation and removal mechanism of material on nano-scale at ultralow loads,a systemic study on AFM micro/nano-machining on single crystal ailicon is conducted. The results indicate that AFM nano- ... To understand the deformation and removal mechanism of material on nano-scale at ultralow loads,a systemic study on AFM micro/nano-machining on single crystal ailicon is conducted. The results indicate that AFM nano- machining has a precisely dimensional controllability and a good surface quality on nanometer scale.A SEM is adopted to observe nano-machined region and chips,the results indicate that the material removal mechanisms change with the applied normal load. An XPS is used to analyze the changes of chemical composition inside and outside the nano-machined region respectively.The nano-indentation which is conducted with the same AFM diamond tip on the machined region shows a big discrepancy compared with that on the macro-scale. The calculated results show higher nano-hardness and elastic modulus than normal values .This phenomenon on be regarded as the indentation size effect(ISE). 展开更多
关键词 ATOMIC FORCE microscope DIAMOND TIP Nano-machining Single CRYSTAL silicon Mechanical property
下载PDF
Chalkiness Characters and Scanning Electron Microscope Observation of Rice Grain Endosperm of Japonica Varieties in Southern Henan 被引量:5
7
作者 Bo PENG Yanfang SUN +8 位作者 Dongyan KONG Ruihua PANG Xiaohua SONG Huilong LI Jintao LI Qiying ZHOU Qiu HAN Shizhi SONG Hongyu YUAN 《Asian Agricultural Research》 2017年第3期80-85,共6页
Chalkiness characters affect not only the grain appearance,milling,eating and cooking qualities but also the grain nutritional quality in rice,thus it is one of the most important traits in rice. It is very important ... Chalkiness characters affect not only the grain appearance,milling,eating and cooking qualities but also the grain nutritional quality in rice,thus it is one of the most important traits in rice. It is very important for us to investigate the relation of the chalkiness formation and the development of endosperm structure and starch granule of different rice varieties. Here,we have investigated the chalkiness characters such as chalkiness rate,chalkiness degree and chalkiness area in 15 japonica rice varieties from southern Henan. Furthermore,the endosperm structure and starch granules of rice grain were also observed with scanning electron microscope. The results showed that the 15 japonica varieties have a significantly linear relationship between the chalkiness rate and chalkiness degree. Among the varieties,the biggest difference is the chalkiness rate,the second is the chalkiness area,and the last is the chalkiness degree. Moreover,there is a certain correlation between the distribution of starch granules,the arrangement of endosperm cells and the occurrence of grain chalkiness in the different rice varieties. For the same variety,the starch granules of chalky and non-chalky grains have obvious difference,while the starch granules from the transparent part of chalky rice and non-chalky rice do not have significant difference. The results would provide useful references for the improvement of grain quality in rice. 展开更多
关键词 CHALKINESS Scanning electron microscope Japonica rice Starch granule ENDOSPERM
下载PDF
Position-resolved Surface Characterization and Nanofabrication Using an Optical Microscope Combined with a Nanopipette/Quartz Tuning Fork Atomic Force Microscope 被引量:2
8
作者 Sangmin An Baekman Sung +6 位作者 Haneol Noh Corey Stambaugh Soyoung Kwon Kunyoung Lee Bongsu Kim Qhwan Kim Wonho Jhe 《Nano-Micro Letters》 SCIE EI CAS 2014年第1期70-79,共10页
In this work, we introduce position-resolved surface characterization and nanofabrication using an optical microscope(OM) combined with a nanopipette-based quartz tuning fork atomic force microscope(nanopipette/QTF-AF... In this work, we introduce position-resolved surface characterization and nanofabrication using an optical microscope(OM) combined with a nanopipette-based quartz tuning fork atomic force microscope(nanopipette/QTF-AFM) system. This system is used to accurately determine substrate position and nanoscale phenomena under ambient conditions. Solutions consisting of 5 nm Au nanoparticles, nanowires, and polydimethylsiloxane(PDMS) are deposited onto the substrate through the nano/microaperture of a pulled pipette. Nano/microscale patterning is performed using a nanopipette/QTF-AFM, while position is resolved by monitoring the substrate with a custom OM. With this tool, one can perform surface characterization(force spectroscopy/microscopy) using the quartz tuning fork(QTF) sensor. Nanofabrication is achieved by accurately positioning target materials on the surface, and on-demand delivery and patterning of various solutions for molecular architecture. 展开更多
关键词 Surface characterization Nanopipette QTF-AFM Optical microscope
下载PDF
A stage-scanning laser confocal microscope and protocol for DNA methylation sequencing 被引量:3
9
作者 Vaithilingam Vaishnavi Litty Varghese Baquir Mohammed Jaffar Ali 《Journal of Biomedical Science and Engineering》 2010年第5期496-500,共5页
Recent understanding of the role of epigenetic regulation in health and disease has necessitated the development of newer and efficient methods to map the methylation pattern of target gene. In this article we report ... Recent understanding of the role of epigenetic regulation in health and disease has necessitated the development of newer and efficient methods to map the methylation pattern of target gene. In this article we report construction of a stage-scanning laser confocal microscope (SLCM) and associated protocol that determines the methylation status of target gene. We have adapted restricted Sanger’s sequencing where fluorescine labeled primers and dideoxy guanine fraction alone are used for target amplification and termination at cytosine positions. Amplified ssDNA bands are separated in 6% denaturing PAGE and scanned using SLCM to sequence the positions of methylated cytosines. We demonstrate that our me- thodology can detect < 100 femtomoles of DNA, and resolve the position of cytosine within ± 2 nucleotide. In a calibration run using a designer DNA of 99 bases, our methodology had resolved all the 11 cytosine positions of the DNA. We have further demonstrated the utility of apparatus by mapping methylation status in the Exon-1 region of a gene, E-Cadherin, in the plasma DNA sample of a healthy subject. We believe our approach constitute a low cost alternative to conventional DNA sequencers and can help develop methylation based DNA biomarkers for the diagnosis of disease and in therapeutics. 展开更多
关键词 Scanning CONFOCAL microscope Fluorescence Detection METHYLATION BISULFITE SEQUENCING DNA Sequencer
下载PDF
Thermal Diffusion of Si Atoms at the Interface of Mo/Si Bilayers Studied with a Soft X-ray Emission Microscope 被引量:1
10
作者 YoshitakaSHITANI NoboruMIYATA +1 位作者 MihiroYANAGIHARA MakotoWATANABE 《光学精密工程》 EI CAS CSCD 2001年第5期446-450,共5页
Thermal diffusion of Si atoms at the interface in Mo/Si multilayers was observed with an imaging type soft X ray emission microscope developed by us. It was possible to observe the diffusion with 0.2nm depth resolutio... Thermal diffusion of Si atoms at the interface in Mo/Si multilayers was observed with an imaging type soft X ray emission microscope developed by us. It was possible to observe the diffusion with 0.2nm depth resolution in the direction normal to the interface by comparing the emission intensity for exactly the same position. The diffusion coefficient of Si atoms in Mo at 600℃ was roughly estimated to be 6.0×10 17 cm 2/s. 展开更多
关键词 MULTILAYER films thermal diffusion SOFT X-ray emission microscope
下载PDF
OBSERVATION OF THE EFFECT OF S-(-)USNIC ACID SODIUM ON TRICHOMONAS VAGINALIS BY TRANSMISSION ELECTRON MICROSCOPE 被引量:1
11
作者 吴杰 张敏如 +2 位作者 丁东宁 谭廷华 闫宝琦 《Journal of Pharmaceutical Analysis》 CAS 1994年第1期56-59,共4页
OBSERVATIONOFTHEEFFECTOFS-(-)USNICACIDSODIUMONTRICHOMONASVAGINALISBYTRANSMISSIONELECTRONMICROSCOPEWuJie;Zhan... OBSERVATIONOFTHEEFFECTOFS-(-)USNICACIDSODIUMONTRICHOMONASVAGINALISBYTRANSMISSIONELECTRONMICROSCOPEWuJie;ZhangMinru;DingDongni... 展开更多
关键词 s-(-)usnic ACID SODIUM TRICHOMONAS vaginalis (T. vag. ) ultrastructure TRANSMISSION ELECTRON microscope (TEM)
下载PDF
Concanavalin A-induced changes in lysosomal morphology of macrophages under confocal microscope 被引量:1
12
作者 雷国华 朴英杰 +2 位作者 鲍永耀 吴建春 黄辉 《Journal of Medical Colleges of PLA(China)》 CAS 1997年第2期100-104,共5页
Changes in lysosomal morphology of cultured mouse peritoneal macrophages after stimu1ation by Concanavalin A (Con A) were observed with a laser scanning confocal microscope (LSCM). A series of images were obtained inc... Changes in lysosomal morphology of cultured mouse peritoneal macrophages after stimu1ation by Concanavalin A (Con A) were observed with a laser scanning confocal microscope (LSCM). A series of images were obtained including phase-contrast images, optical sectioning images, 3-dimensional reconstruction images. The changes of lysosomal fluorescence intensity and pH were measured. It was found that macrophage lysosomes were Cllstributed mainly at the periphery of the cells in resting conditions, the lysosomal area containing fluorescence probe became markedly enlarged after stimulation by Con A for 30 min, and the fluorescence intensity in the medium increased about 15 min after suggesting that Con A could induce outflow of the fluorescence probe within the macrophage lysosomes. The lysosomal pH rose from 4. 6 to 5. 7 in 7 min after Con A was added, and maintained at that level hereafter. 展开更多
关键词 MACROPHAGE LYSOSOME Concanavalin A CONFOCAL microscope
下载PDF
Research on a Diamond Tip Wear Mechanism in Atomic Force Microscope-based Micro/nano-machining 被引量:1
13
作者 赵清亮 《High Technology Letters》 EI CAS 2001年第3期84-89,共6页
The object is to investigate the wear of an atomic force microscope (AFM) diamond tip when conducting micro/nano machining on single crystal silicon surface. The experimental research and theoretical analysis were car... The object is to investigate the wear of an atomic force microscope (AFM) diamond tip when conducting micro/nano machining on single crystal silicon surface. The experimental research and theoretical analysis were carried out on the worn tip in terms of wear rate, wear mechanism and the effect of the tip wear on micro machining process. The wear rate was calculated as 1.7(10~10mm 3/(N·m) by using a theoretical model combined with the experimental results. Through an integration of an AFM observation on the worn tip features with the FEM simulation of the stress distribution, in addition to the unit cutting force calculation on the AFM diamond tip, the wear mechanism of the AFM diamond tip was concluded as mainly chemical wear, and the wear process was also elaborated as well. 展开更多
关键词 ATOMIC FORCE microscope DIAMOND TIP single crystal silicon micro/nano machining chemical wear
下载PDF
At wavelength coherent scatterometry microscope using high-order harmonics for EUV mask inspection 被引量:1
14
作者 Yutaka Nagata Tetsuo Harada +2 位作者 Takeo Watanabe Hiroo Kinoshita Katsumi Midorikawa 《International Journal of Extreme Manufacturing》 2019年第3期1-12,共12页
In this review,we describe our research on the development of the 13.5 nm coherent microscope using high-order harmonics for the mask inspection of extreme ultraviolet(EUV)lithography.EUV lithography is a game-changin... In this review,we describe our research on the development of the 13.5 nm coherent microscope using high-order harmonics for the mask inspection of extreme ultraviolet(EUV)lithography.EUV lithography is a game-changing piece of technology for high-volume manufacturing of commercial semiconductors.Many top manufacturers apply EUV technology for fabricating the most critical layers of 7 nm chips.Fabrication and inspection of defect-free masks,however,still remain critical issues in EUV technology.Thus,in our pursuit for a resolution,we have developed the coherent EUV scatterometry microscope(CSM)system with a synchrotron radiation(SR)source to establish the actinic metrology,along with inspection algorithms.The intensity and phase images of patterned EUV masks were reconstructed from diffraction patterns using ptychography algorithms.To expedite the practical application of the CSM,we have also developed a standalone CSM,based on high-order harmonic generation,as an alternative to the SR-CSM.Since the application of a coherent 13.5 nm harmonic enabled the production of a high contrast diffraction pattern,diffraction patterns of sub-100 ns size defects in a 2D periodic pattern mask could be observed.Reconstruction of intensity and phase images from diffraction patterns were also performed for a periodic line-and-space structure,an aperiodic angle edge structure,as well as a cross pattern in an EUV mask. 展开更多
关键词 high-order harmonics coherent EUV light EUV lithography coherent EUV scatterometry microscope synchrotron radiation EUV mask inspection
下载PDF
Determination of Substitutional Carbon in SI-GaAs Thin Wafers by Infrared Microscope
15
作者 何秀坤 王琴 +1 位作者 汝琼娜 李光平 《Rare Metals》 SCIE EI CAS CSCD 1993年第4期284-287,共4页
Determination of substitutional carbon in SI-GaAs thin wafers was investigated by FT-IR microscopeat room temperature for the first time.The experimental results showed that the carbon concentration inGaAs thin wafers... Determination of substitutional carbon in SI-GaAs thin wafers was investigated by FT-IR microscopeat room temperature for the first time.The experimental results showed that the carbon concentration inGaAs thin wafers can be measured directly with simple treatment.The calculation method of carbon concen-tration is in agreement with that for normal IR spectrum with 0.5 cm<sup>-1</sup>resolution.The resolution of1 cm<sup>-1</sup>can be taken in order to obtain a high signal-to-noise(S/N)ratio using 2.34×10<sup>16</sup>cm<sup>-2</sup>calibration factor for calculating carbon concentration at room temperature. 展开更多
关键词 Infrared microscope SI-GAAS THIN WAFERS SUBSTITUTIONAL CARBON concentration
下载PDF
Virtual&augmented reality for biological microscope in experiment education 被引量:1
16
作者 Xiang ZHOU Liyu TANG +1 位作者 Ding LIN Wei HAN 《Virtual Reality & Intelligent Hardware》 2020年第4期316-329,共14页
Background Mixed-reality technologies,including virtual reality(VR)and augmented reality(AR),are considered to be promising potential tools for science teaching and learning processes that could foster positive emotio... Background Mixed-reality technologies,including virtual reality(VR)and augmented reality(AR),are considered to be promising potential tools for science teaching and learning processes that could foster positive emotions,motivate autonomous learning,and improve learning outcomes.Methods In this study,a technology-aided biological microscope learning system based on VR/AR is presented.The structure of the microscope is described in a detailed three-dimensional(3D)model,each component being represented with their topological interrelationships and associations among them being established.The interactive behavior of the model was specified,and a standard operating guide was compiled.The motion control of components was simulated based on collision detection.Combined with immersive VR equipment and AR technology,we developed a virtual microscope subsystem and a mobile virtual microscope guidance system.Results The system consisted of a VR subsystem and an AR subsystem.The focus of the VR subsystem was to simulate operating the microscope and associated interactive behaviors that allowed users to observe and operate the components of the 3D microscope model by means of natural interactions in an immersive scenario.The AR subsystem allowed participants to use a mobile terminal that took a picture of a microscope from a textbook and then displayed the structure and functions of the instrument,as well as the relevant operating guidance.This flexibly allowed students to use the system before or after class without time and space constraints.The system allowed users to switch between the VR and AR subsystems.Conclusions The system is useful for helping learners(especially K-12 students)to recognize a microscope's structure and grasp the required operational skills by simulating operations using an interactive process.In the future,such technology-assisted education would be a successful learning platform in an open learning space. 展开更多
关键词 Virtual reality Augmented reality microscope Operating guide EXPERIMENT
下载PDF
STUDY ON THE MICROSTRUCTURE AND PROPERTY OF PET FIBER BY LASER RAMAN MICROSCOPE
17
作者 尹秀丽 《Chinese Journal of Polymer Science》 SCIE CAS CSCD 1994年第2期126-131,共6页
In this paper, the microstructure change of one step-draw PET fiber has been studied byvarious methods, such as, Laser Raman Microscope, Wide-angle X-ray, Density-gradient andPolarizing Microscope. The computer has be... In this paper, the microstructure change of one step-draw PET fiber has been studied byvarious methods, such as, Laser Raman Microscope, Wide-angle X-ray, Density-gradient andPolarizing Microscope. The computer has been used to resolve overlapped bands in the Ramanspectra. Then the band changes have been correlated with trans, gauche and stressed trans-conformations indicated by a conformational index. Based on these indices, the relationshipbetween the conformation change of glycol units in the fiber structure and the macromechanicalproperties of fiber is expounded. 展开更多
关键词 LASER RAMAN microscope PET FIBER Structure PROPERTY
下载PDF
ELECTRON MICROSCOPE EVIDENCE OF VIRUS INFECTION IN CULTURED MARINE FISH
18
作者 孙修勤 张进兴 曲凌云 《Chinese Journal of Oceanology and Limnology》 SCIE CAS CSCD 2000年第3期280-282,290,共4页
Electron microscope investigation on the red sea bream ( Pagrosomus major ), bastard halibut ( Paralichthys olivaceus ) and stone flounder ( Kareius bicoloratus ) in North China revealed virus infection in the bodies ... Electron microscope investigation on the red sea bream ( Pagrosomus major ), bastard halibut ( Paralichthys olivaceus ) and stone flounder ( Kareius bicoloratus ) in North China revealed virus infection in the bodies of the dead and diseased fish. These viruses included the lymphocystis disease virus (LDV), parvovirus, globular virus, and a kind of baculavirus which was not discovered and reported before and is now tentatively named baculavirus of stone flounder ( Kareius bicoloratus ). 展开更多
关键词 CULTURED MARINE FISHES viruses electron microscope
原文传递
Operating microscope in endodontics:A systematic review 被引量:1
19
作者 Carla Cabral dos Santos Accioly Lins Elma Mariana Vercosa de Melo Silva +2 位作者 Georgina Agnelo de Lima Silvio Emanuel Acioly Conrado de Menezes Rosana Maria Coelho Travassos 《Open Journal of Stomatology》 2013年第9期1-5,共5页
The objective of this study was to systematically review the literature about the use of the operating microscope in endodontics. It used sources of bibliographic cataloging electronically identified by MEDLINE via Pu... The objective of this study was to systematically review the literature about the use of the operating microscope in endodontics. It used sources of bibliographic cataloging electronically identified by MEDLINE via PubMed, LILACS, BBO and Scopus, using as descriptors: Endodontics, anatomy and microscopy. The selected articles were identified from the titles and abstracts, taking into consideration the following criteria: publications ranging from January 2001 to November 2012, case reports, published in an indexed journal, and publications in English language. The search showed 167 articles related to this topic, and these 21 articles met the inclusion criteria. These indicated that a higher magnification helps coronary access and the location of channels to identify and interpret the complexities of the anatomy of root canals, the removal of nuclei and intracoronary fractured instruments, to minimize trauma of surgeries in soft and hard tissues, and detect fractures and microfractures. It was found that its use has provided Endodontics with a significant improvement in vision of the operative field, offering better quality jobs and a higher success rate. 展开更多
关键词 ENDODONTICS ANATOMY microscope Systematic Review
下载PDF