The process of wound healing is routinely evaluated by histological evaluation in the clinic,which may cause scarring and secondary injury.Reflectance confocal microscopy(RCM)represents a noninvasive,real-time imaging...The process of wound healing is routinely evaluated by histological evaluation in the clinic,which may cause scarring and secondary injury.Reflectance confocal microscopy(RCM)represents a noninvasive,real-time imaging technique that allows in vivo evaluation of the skin.Traditional RCM was wide-probe-based,which limited its application on uneven and covered skin.In this study,we report the development of a portable reflectance confocal microscope(PRCM)in which all components were assembled in a handheld shell.Although the size and weight of the PRCM were reduced based on the use of a microelectromechanical system,the resolution was kept at 0.91μm,and the field of view of the system was 343μm×532μm.When used in vivo,the PRCM was able to visualize cellular and nuclear morphology for both mouse and human skin.PRCM evaluations were then performed on wounds after topically applied mesenchymal stem cells(MSCs)or saline treatment.The PRCM allowed visualization of the formation of collagen bundles,re-epithelization from the wound edge to the wound bed,and hair follicle regeneration,which were consistent with histological evaluations.Therefore,we offer new insights into monitoring the effects of topically applied MSCs on the process of wound healing by using PRCM.This study illustrates that the newly developed PRCM represents a promising device for real-time,noninvasive monitoring of the dynamic process of wound healing,which demonstrates its potential to diagnose,monitor,or predict disease in clinical wound therapy.展开更多
In the metrology of radon, an environmental lung carcinogen, the integrated measurements necessary for epidemiological studies are made very often using the tracks detector LR 115 type 2. For dosimetric analysis, the ...In the metrology of radon, an environmental lung carcinogen, the integrated measurements necessary for epidemiological studies are made very often using the tracks detector LR 115 type 2. For dosimetric analysis, the etched tracks from radon alpha particles on this detector are usually counted by means of an optical microscope or a spark counter. An optimal reading of the track densities which must be converted into radon concentrations, can’t be done without a good mastery of the mode of operation and use of these devices. Furthermore, investigations to know as to whether or not each of those can be used to determine radon concentration are necessary. These are the objectives of the present work in which LR 115 samples exposed to radon for at least 3 months, were chemically developed under standard conditions and read. The track densities obtained with the microscope are very much higher than those of the counter for each sample. These results are consistent with those published by other authors. However, each of these devices can be used interchangeably for alpha tracks counting, as both provide radon concentrations with a very good linear correlation coefficient of 0.95 taking into account their respective calibration factors for the reading of this detector. In addition, the saturation phenomenon for the spark counter reading of LR 115 detector occurs beyond 11,000 tr/cm<sup>2</sup>, a density never reached during our environmental radon measurements.展开更多
To understand the deformation and removal mechanism of material on nano-scale at ultralow loads,a systemic study on AFM micro/nano-machining on single crystal ailicon is conducted. The results indicate that AFM nano- ...To understand the deformation and removal mechanism of material on nano-scale at ultralow loads,a systemic study on AFM micro/nano-machining on single crystal ailicon is conducted. The results indicate that AFM nano- machining has a precisely dimensional controllability and a good surface quality on nanometer scale.A SEM is adopted to observe nano-machined region and chips,the results indicate that the material removal mechanisms change with the applied normal load. An XPS is used to analyze the changes of chemical composition inside and outside the nano-machined region respectively.The nano-indentation which is conducted with the same AFM diamond tip on the machined region shows a big discrepancy compared with that on the macro-scale. The calculated results show higher nano-hardness and elastic modulus than normal values .This phenomenon on be regarded as the indentation size effect(ISE).展开更多
Chalkiness characters affect not only the grain appearance,milling,eating and cooking qualities but also the grain nutritional quality in rice,thus it is one of the most important traits in rice. It is very important ...Chalkiness characters affect not only the grain appearance,milling,eating and cooking qualities but also the grain nutritional quality in rice,thus it is one of the most important traits in rice. It is very important for us to investigate the relation of the chalkiness formation and the development of endosperm structure and starch granule of different rice varieties. Here,we have investigated the chalkiness characters such as chalkiness rate,chalkiness degree and chalkiness area in 15 japonica rice varieties from southern Henan. Furthermore,the endosperm structure and starch granules of rice grain were also observed with scanning electron microscope. The results showed that the 15 japonica varieties have a significantly linear relationship between the chalkiness rate and chalkiness degree. Among the varieties,the biggest difference is the chalkiness rate,the second is the chalkiness area,and the last is the chalkiness degree. Moreover,there is a certain correlation between the distribution of starch granules,the arrangement of endosperm cells and the occurrence of grain chalkiness in the different rice varieties. For the same variety,the starch granules of chalky and non-chalky grains have obvious difference,while the starch granules from the transparent part of chalky rice and non-chalky rice do not have significant difference. The results would provide useful references for the improvement of grain quality in rice.展开更多
In this work, we introduce position-resolved surface characterization and nanofabrication using an optical microscope(OM) combined with a nanopipette-based quartz tuning fork atomic force microscope(nanopipette/QTF-AF...In this work, we introduce position-resolved surface characterization and nanofabrication using an optical microscope(OM) combined with a nanopipette-based quartz tuning fork atomic force microscope(nanopipette/QTF-AFM) system. This system is used to accurately determine substrate position and nanoscale phenomena under ambient conditions. Solutions consisting of 5 nm Au nanoparticles, nanowires, and polydimethylsiloxane(PDMS) are deposited onto the substrate through the nano/microaperture of a pulled pipette. Nano/microscale patterning is performed using a nanopipette/QTF-AFM, while position is resolved by monitoring the substrate with a custom OM. With this tool, one can perform surface characterization(force spectroscopy/microscopy) using the quartz tuning fork(QTF) sensor. Nanofabrication is achieved by accurately positioning target materials on the surface, and on-demand delivery and patterning of various solutions for molecular architecture.展开更多
Recent understanding of the role of epigenetic regulation in health and disease has necessitated the development of newer and efficient methods to map the methylation pattern of target gene. In this article we report ...Recent understanding of the role of epigenetic regulation in health and disease has necessitated the development of newer and efficient methods to map the methylation pattern of target gene. In this article we report construction of a stage-scanning laser confocal microscope (SLCM) and associated protocol that determines the methylation status of target gene. We have adapted restricted Sanger’s sequencing where fluorescine labeled primers and dideoxy guanine fraction alone are used for target amplification and termination at cytosine positions. Amplified ssDNA bands are separated in 6% denaturing PAGE and scanned using SLCM to sequence the positions of methylated cytosines. We demonstrate that our me- thodology can detect < 100 femtomoles of DNA, and resolve the position of cytosine within ± 2 nucleotide. In a calibration run using a designer DNA of 99 bases, our methodology had resolved all the 11 cytosine positions of the DNA. We have further demonstrated the utility of apparatus by mapping methylation status in the Exon-1 region of a gene, E-Cadherin, in the plasma DNA sample of a healthy subject. We believe our approach constitute a low cost alternative to conventional DNA sequencers and can help develop methylation based DNA biomarkers for the diagnosis of disease and in therapeutics.展开更多
Thermal diffusion of Si atoms at the interface in Mo/Si multilayers was observed with an imaging type soft X ray emission microscope developed by us. It was possible to observe the diffusion with 0.2nm depth resolutio...Thermal diffusion of Si atoms at the interface in Mo/Si multilayers was observed with an imaging type soft X ray emission microscope developed by us. It was possible to observe the diffusion with 0.2nm depth resolution in the direction normal to the interface by comparing the emission intensity for exactly the same position. The diffusion coefficient of Si atoms in Mo at 600℃ was roughly estimated to be 6.0×10 17 cm 2/s.展开更多
Changes in lysosomal morphology of cultured mouse peritoneal macrophages after stimu1ation by Concanavalin A (Con A) were observed with a laser scanning confocal microscope (LSCM). A series of images were obtained inc...Changes in lysosomal morphology of cultured mouse peritoneal macrophages after stimu1ation by Concanavalin A (Con A) were observed with a laser scanning confocal microscope (LSCM). A series of images were obtained including phase-contrast images, optical sectioning images, 3-dimensional reconstruction images. The changes of lysosomal fluorescence intensity and pH were measured. It was found that macrophage lysosomes were Cllstributed mainly at the periphery of the cells in resting conditions, the lysosomal area containing fluorescence probe became markedly enlarged after stimulation by Con A for 30 min, and the fluorescence intensity in the medium increased about 15 min after suggesting that Con A could induce outflow of the fluorescence probe within the macrophage lysosomes. The lysosomal pH rose from 4. 6 to 5. 7 in 7 min after Con A was added, and maintained at that level hereafter.展开更多
The object is to investigate the wear of an atomic force microscope (AFM) diamond tip when conducting micro/nano machining on single crystal silicon surface. The experimental research and theoretical analysis were car...The object is to investigate the wear of an atomic force microscope (AFM) diamond tip when conducting micro/nano machining on single crystal silicon surface. The experimental research and theoretical analysis were carried out on the worn tip in terms of wear rate, wear mechanism and the effect of the tip wear on micro machining process. The wear rate was calculated as 1.7(10~10mm 3/(N·m) by using a theoretical model combined with the experimental results. Through an integration of an AFM observation on the worn tip features with the FEM simulation of the stress distribution, in addition to the unit cutting force calculation on the AFM diamond tip, the wear mechanism of the AFM diamond tip was concluded as mainly chemical wear, and the wear process was also elaborated as well.展开更多
In this review,we describe our research on the development of the 13.5 nm coherent microscope using high-order harmonics for the mask inspection of extreme ultraviolet(EUV)lithography.EUV lithography is a game-changin...In this review,we describe our research on the development of the 13.5 nm coherent microscope using high-order harmonics for the mask inspection of extreme ultraviolet(EUV)lithography.EUV lithography is a game-changing piece of technology for high-volume manufacturing of commercial semiconductors.Many top manufacturers apply EUV technology for fabricating the most critical layers of 7 nm chips.Fabrication and inspection of defect-free masks,however,still remain critical issues in EUV technology.Thus,in our pursuit for a resolution,we have developed the coherent EUV scatterometry microscope(CSM)system with a synchrotron radiation(SR)source to establish the actinic metrology,along with inspection algorithms.The intensity and phase images of patterned EUV masks were reconstructed from diffraction patterns using ptychography algorithms.To expedite the practical application of the CSM,we have also developed a standalone CSM,based on high-order harmonic generation,as an alternative to the SR-CSM.Since the application of a coherent 13.5 nm harmonic enabled the production of a high contrast diffraction pattern,diffraction patterns of sub-100 ns size defects in a 2D periodic pattern mask could be observed.Reconstruction of intensity and phase images from diffraction patterns were also performed for a periodic line-and-space structure,an aperiodic angle edge structure,as well as a cross pattern in an EUV mask.展开更多
Determination of substitutional carbon in SI-GaAs thin wafers was investigated by FT-IR microscopeat room temperature for the first time.The experimental results showed that the carbon concentration inGaAs thin wafers...Determination of substitutional carbon in SI-GaAs thin wafers was investigated by FT-IR microscopeat room temperature for the first time.The experimental results showed that the carbon concentration inGaAs thin wafers can be measured directly with simple treatment.The calculation method of carbon concen-tration is in agreement with that for normal IR spectrum with 0.5 cm<sup>-1</sup>resolution.The resolution of1 cm<sup>-1</sup>can be taken in order to obtain a high signal-to-noise(S/N)ratio using 2.34×10<sup>16</sup>cm<sup>-2</sup>calibration factor for calculating carbon concentration at room temperature.展开更多
Background Mixed-reality technologies,including virtual reality(VR)and augmented reality(AR),are considered to be promising potential tools for science teaching and learning processes that could foster positive emotio...Background Mixed-reality technologies,including virtual reality(VR)and augmented reality(AR),are considered to be promising potential tools for science teaching and learning processes that could foster positive emotions,motivate autonomous learning,and improve learning outcomes.Methods In this study,a technology-aided biological microscope learning system based on VR/AR is presented.The structure of the microscope is described in a detailed three-dimensional(3D)model,each component being represented with their topological interrelationships and associations among them being established.The interactive behavior of the model was specified,and a standard operating guide was compiled.The motion control of components was simulated based on collision detection.Combined with immersive VR equipment and AR technology,we developed a virtual microscope subsystem and a mobile virtual microscope guidance system.Results The system consisted of a VR subsystem and an AR subsystem.The focus of the VR subsystem was to simulate operating the microscope and associated interactive behaviors that allowed users to observe and operate the components of the 3D microscope model by means of natural interactions in an immersive scenario.The AR subsystem allowed participants to use a mobile terminal that took a picture of a microscope from a textbook and then displayed the structure and functions of the instrument,as well as the relevant operating guidance.This flexibly allowed students to use the system before or after class without time and space constraints.The system allowed users to switch between the VR and AR subsystems.Conclusions The system is useful for helping learners(especially K-12 students)to recognize a microscope's structure and grasp the required operational skills by simulating operations using an interactive process.In the future,such technology-assisted education would be a successful learning platform in an open learning space.展开更多
In this paper, the microstructure change of one step-draw PET fiber has been studied byvarious methods, such as, Laser Raman Microscope, Wide-angle X-ray, Density-gradient andPolarizing Microscope. The computer has be...In this paper, the microstructure change of one step-draw PET fiber has been studied byvarious methods, such as, Laser Raman Microscope, Wide-angle X-ray, Density-gradient andPolarizing Microscope. The computer has been used to resolve overlapped bands in the Ramanspectra. Then the band changes have been correlated with trans, gauche and stressed trans-conformations indicated by a conformational index. Based on these indices, the relationshipbetween the conformation change of glycol units in the fiber structure and the macromechanicalproperties of fiber is expounded.展开更多
Electron microscope investigation on the red sea bream ( Pagrosomus major ), bastard halibut ( Paralichthys olivaceus ) and stone flounder ( Kareius bicoloratus ) in North China revealed virus infection in the bodies ...Electron microscope investigation on the red sea bream ( Pagrosomus major ), bastard halibut ( Paralichthys olivaceus ) and stone flounder ( Kareius bicoloratus ) in North China revealed virus infection in the bodies of the dead and diseased fish. These viruses included the lymphocystis disease virus (LDV), parvovirus, globular virus, and a kind of baculavirus which was not discovered and reported before and is now tentatively named baculavirus of stone flounder ( Kareius bicoloratus ).展开更多
The objective of this study was to systematically review the literature about the use of the operating microscope in endodontics. It used sources of bibliographic cataloging electronically identified by MEDLINE via Pu...The objective of this study was to systematically review the literature about the use of the operating microscope in endodontics. It used sources of bibliographic cataloging electronically identified by MEDLINE via PubMed, LILACS, BBO and Scopus, using as descriptors: Endodontics, anatomy and microscopy. The selected articles were identified from the titles and abstracts, taking into consideration the following criteria: publications ranging from January 2001 to November 2012, case reports, published in an indexed journal, and publications in English language. The search showed 167 articles related to this topic, and these 21 articles met the inclusion criteria. These indicated that a higher magnification helps coronary access and the location of channels to identify and interpret the complexities of the anatomy of root canals, the removal of nuclei and intracoronary fractured instruments, to minimize trauma of surgeries in soft and hard tissues, and detect fractures and microfractures. It was found that its use has provided Endodontics with a significant improvement in vision of the operative field, offering better quality jobs and a higher success rate.展开更多
基金the National Key Research andDevelopment Program of China(No.2021YFA1101100)the Strategic Priority Research Program of the Chinese Academy of Sciences(No.XDA16020807)+3 种基金the Major Innovative Research Team of Suzhou,China(No.ZXT2019007)Suzhou Institute of Biomedical Engineering and Technology(SIBET)Jilin City Science and Technology Cooperation Project(No.E0550104)Science and Technology Innovation Talents in Universities of Henan Province and Doctor of Entrepreneurship and Innovation Program of Jiangsu Province in the year of 2020.
文摘The process of wound healing is routinely evaluated by histological evaluation in the clinic,which may cause scarring and secondary injury.Reflectance confocal microscopy(RCM)represents a noninvasive,real-time imaging technique that allows in vivo evaluation of the skin.Traditional RCM was wide-probe-based,which limited its application on uneven and covered skin.In this study,we report the development of a portable reflectance confocal microscope(PRCM)in which all components were assembled in a handheld shell.Although the size and weight of the PRCM were reduced based on the use of a microelectromechanical system,the resolution was kept at 0.91μm,and the field of view of the system was 343μm×532μm.When used in vivo,the PRCM was able to visualize cellular and nuclear morphology for both mouse and human skin.PRCM evaluations were then performed on wounds after topically applied mesenchymal stem cells(MSCs)or saline treatment.The PRCM allowed visualization of the formation of collagen bundles,re-epithelization from the wound edge to the wound bed,and hair follicle regeneration,which were consistent with histological evaluations.Therefore,we offer new insights into monitoring the effects of topically applied MSCs on the process of wound healing by using PRCM.This study illustrates that the newly developed PRCM represents a promising device for real-time,noninvasive monitoring of the dynamic process of wound healing,which demonstrates its potential to diagnose,monitor,or predict disease in clinical wound therapy.
文摘In the metrology of radon, an environmental lung carcinogen, the integrated measurements necessary for epidemiological studies are made very often using the tracks detector LR 115 type 2. For dosimetric analysis, the etched tracks from radon alpha particles on this detector are usually counted by means of an optical microscope or a spark counter. An optimal reading of the track densities which must be converted into radon concentrations, can’t be done without a good mastery of the mode of operation and use of these devices. Furthermore, investigations to know as to whether or not each of those can be used to determine radon concentration are necessary. These are the objectives of the present work in which LR 115 samples exposed to radon for at least 3 months, were chemically developed under standard conditions and read. The track densities obtained with the microscope are very much higher than those of the counter for each sample. These results are consistent with those published by other authors. However, each of these devices can be used interchangeably for alpha tracks counting, as both provide radon concentrations with a very good linear correlation coefficient of 0.95 taking into account their respective calibration factors for the reading of this detector. In addition, the saturation phenomenon for the spark counter reading of LR 115 detector occurs beyond 11,000 tr/cm<sup>2</sup>, a density never reached during our environmental radon measurements.
基金This project is supported by National Natural ScienceFoundation of China (No.59835180) and Science andTechnology Foundatio
文摘To understand the deformation and removal mechanism of material on nano-scale at ultralow loads,a systemic study on AFM micro/nano-machining on single crystal ailicon is conducted. The results indicate that AFM nano- machining has a precisely dimensional controllability and a good surface quality on nanometer scale.A SEM is adopted to observe nano-machined region and chips,the results indicate that the material removal mechanisms change with the applied normal load. An XPS is used to analyze the changes of chemical composition inside and outside the nano-machined region respectively.The nano-indentation which is conducted with the same AFM diamond tip on the machined region shows a big discrepancy compared with that on the macro-scale. The calculated results show higher nano-hardness and elastic modulus than normal values .This phenomenon on be regarded as the indentation size effect(ISE).
基金Supported by Key Project of Science and Technology in Henan Province(152102110100,152102110036)National Natural Science Foundation of China(U1604110,U1404319,31270727,31600992)+3 种基金Nanhu Scholars Program for Young Scholars of XYNU(2016056)Major Science and Technology Project in Henan Province(121100110200)Students Scientific Research Fund of Xinyang Normal University(2015-DXS-158)Fund of Institute for Conservation and Utilization of Agro-bioresources in Dabie Mountains(2016020)
文摘Chalkiness characters affect not only the grain appearance,milling,eating and cooking qualities but also the grain nutritional quality in rice,thus it is one of the most important traits in rice. It is very important for us to investigate the relation of the chalkiness formation and the development of endosperm structure and starch granule of different rice varieties. Here,we have investigated the chalkiness characters such as chalkiness rate,chalkiness degree and chalkiness area in 15 japonica rice varieties from southern Henan. Furthermore,the endosperm structure and starch granules of rice grain were also observed with scanning electron microscope. The results showed that the 15 japonica varieties have a significantly linear relationship between the chalkiness rate and chalkiness degree. Among the varieties,the biggest difference is the chalkiness rate,the second is the chalkiness area,and the last is the chalkiness degree. Moreover,there is a certain correlation between the distribution of starch granules,the arrangement of endosperm cells and the occurrence of grain chalkiness in the different rice varieties. For the same variety,the starch granules of chalky and non-chalky grains have obvious difference,while the starch granules from the transparent part of chalky rice and non-chalky rice do not have significant difference. The results would provide useful references for the improvement of grain quality in rice.
基金supported by the National Research Foundation of Korea (NRF) grant funded by the Korea government (MSIP) (2013-056344)Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education,Science and Technology (2013R1A6A3A03063900)+1 种基金support from Center for Nano-Liquidsupport from the National Science Foundation OISE Grant #0853104
文摘In this work, we introduce position-resolved surface characterization and nanofabrication using an optical microscope(OM) combined with a nanopipette-based quartz tuning fork atomic force microscope(nanopipette/QTF-AFM) system. This system is used to accurately determine substrate position and nanoscale phenomena under ambient conditions. Solutions consisting of 5 nm Au nanoparticles, nanowires, and polydimethylsiloxane(PDMS) are deposited onto the substrate through the nano/microaperture of a pulled pipette. Nano/microscale patterning is performed using a nanopipette/QTF-AFM, while position is resolved by monitoring the substrate with a custom OM. With this tool, one can perform surface characterization(force spectroscopy/microscopy) using the quartz tuning fork(QTF) sensor. Nanofabrication is achieved by accurately positioning target materials on the surface, and on-demand delivery and patterning of various solutions for molecular architecture.
文摘Recent understanding of the role of epigenetic regulation in health and disease has necessitated the development of newer and efficient methods to map the methylation pattern of target gene. In this article we report construction of a stage-scanning laser confocal microscope (SLCM) and associated protocol that determines the methylation status of target gene. We have adapted restricted Sanger’s sequencing where fluorescine labeled primers and dideoxy guanine fraction alone are used for target amplification and termination at cytosine positions. Amplified ssDNA bands are separated in 6% denaturing PAGE and scanned using SLCM to sequence the positions of methylated cytosines. We demonstrate that our me- thodology can detect < 100 femtomoles of DNA, and resolve the position of cytosine within ± 2 nucleotide. In a calibration run using a designer DNA of 99 bases, our methodology had resolved all the 11 cytosine positions of the DNA. We have further demonstrated the utility of apparatus by mapping methylation status in the Exon-1 region of a gene, E-Cadherin, in the plasma DNA sample of a healthy subject. We believe our approach constitute a low cost alternative to conventional DNA sequencers and can help develop methylation based DNA biomarkers for the diagnosis of disease and in therapeutics.
文摘Thermal diffusion of Si atoms at the interface in Mo/Si multilayers was observed with an imaging type soft X ray emission microscope developed by us. It was possible to observe the diffusion with 0.2nm depth resolution in the direction normal to the interface by comparing the emission intensity for exactly the same position. The diffusion coefficient of Si atoms in Mo at 600℃ was roughly estimated to be 6.0×10 17 cm 2/s.
文摘Changes in lysosomal morphology of cultured mouse peritoneal macrophages after stimu1ation by Concanavalin A (Con A) were observed with a laser scanning confocal microscope (LSCM). A series of images were obtained including phase-contrast images, optical sectioning images, 3-dimensional reconstruction images. The changes of lysosomal fluorescence intensity and pH were measured. It was found that macrophage lysosomes were Cllstributed mainly at the periphery of the cells in resting conditions, the lysosomal area containing fluorescence probe became markedly enlarged after stimulation by Con A for 30 min, and the fluorescence intensity in the medium increased about 15 min after suggesting that Con A could induce outflow of the fluorescence probe within the macrophage lysosomes. The lysosomal pH rose from 4. 6 to 5. 7 in 7 min after Con A was added, and maintained at that level hereafter.
文摘The object is to investigate the wear of an atomic force microscope (AFM) diamond tip when conducting micro/nano machining on single crystal silicon surface. The experimental research and theoretical analysis were carried out on the worn tip in terms of wear rate, wear mechanism and the effect of the tip wear on micro machining process. The wear rate was calculated as 1.7(10~10mm 3/(N·m) by using a theoretical model combined with the experimental results. Through an integration of an AFM observation on the worn tip features with the FEM simulation of the stress distribution, in addition to the unit cutting force calculation on the AFM diamond tip, the wear mechanism of the AFM diamond tip was concluded as mainly chemical wear, and the wear process was also elaborated as well.
文摘In this review,we describe our research on the development of the 13.5 nm coherent microscope using high-order harmonics for the mask inspection of extreme ultraviolet(EUV)lithography.EUV lithography is a game-changing piece of technology for high-volume manufacturing of commercial semiconductors.Many top manufacturers apply EUV technology for fabricating the most critical layers of 7 nm chips.Fabrication and inspection of defect-free masks,however,still remain critical issues in EUV technology.Thus,in our pursuit for a resolution,we have developed the coherent EUV scatterometry microscope(CSM)system with a synchrotron radiation(SR)source to establish the actinic metrology,along with inspection algorithms.The intensity and phase images of patterned EUV masks were reconstructed from diffraction patterns using ptychography algorithms.To expedite the practical application of the CSM,we have also developed a standalone CSM,based on high-order harmonic generation,as an alternative to the SR-CSM.Since the application of a coherent 13.5 nm harmonic enabled the production of a high contrast diffraction pattern,diffraction patterns of sub-100 ns size defects in a 2D periodic pattern mask could be observed.Reconstruction of intensity and phase images from diffraction patterns were also performed for a periodic line-and-space structure,an aperiodic angle edge structure,as well as a cross pattern in an EUV mask.
文摘Determination of substitutional carbon in SI-GaAs thin wafers was investigated by FT-IR microscopeat room temperature for the first time.The experimental results showed that the carbon concentration inGaAs thin wafers can be measured directly with simple treatment.The calculation method of carbon concen-tration is in agreement with that for normal IR spectrum with 0.5 cm<sup>-1</sup>resolution.The resolution of1 cm<sup>-1</sup>can be taken in order to obtain a high signal-to-noise(S/N)ratio using 2.34×10<sup>16</sup>cm<sup>-2</sup>calibration factor for calculating carbon concentration at room temperature.
基金the National Key Research and Development Program of China(2018YFB1004905).
文摘Background Mixed-reality technologies,including virtual reality(VR)and augmented reality(AR),are considered to be promising potential tools for science teaching and learning processes that could foster positive emotions,motivate autonomous learning,and improve learning outcomes.Methods In this study,a technology-aided biological microscope learning system based on VR/AR is presented.The structure of the microscope is described in a detailed three-dimensional(3D)model,each component being represented with their topological interrelationships and associations among them being established.The interactive behavior of the model was specified,and a standard operating guide was compiled.The motion control of components was simulated based on collision detection.Combined with immersive VR equipment and AR technology,we developed a virtual microscope subsystem and a mobile virtual microscope guidance system.Results The system consisted of a VR subsystem and an AR subsystem.The focus of the VR subsystem was to simulate operating the microscope and associated interactive behaviors that allowed users to observe and operate the components of the 3D microscope model by means of natural interactions in an immersive scenario.The AR subsystem allowed participants to use a mobile terminal that took a picture of a microscope from a textbook and then displayed the structure and functions of the instrument,as well as the relevant operating guidance.This flexibly allowed students to use the system before or after class without time and space constraints.The system allowed users to switch between the VR and AR subsystems.Conclusions The system is useful for helping learners(especially K-12 students)to recognize a microscope's structure and grasp the required operational skills by simulating operations using an interactive process.In the future,such technology-assisted education would be a successful learning platform in an open learning space.
文摘In this paper, the microstructure change of one step-draw PET fiber has been studied byvarious methods, such as, Laser Raman Microscope, Wide-angle X-ray, Density-gradient andPolarizing Microscope. The computer has been used to resolve overlapped bands in the Ramanspectra. Then the band changes have been correlated with trans, gauche and stressed trans-conformations indicated by a conformational index. Based on these indices, the relationshipbetween the conformation change of glycol units in the fiber structure and the macromechanicalproperties of fiber is expounded.
文摘Electron microscope investigation on the red sea bream ( Pagrosomus major ), bastard halibut ( Paralichthys olivaceus ) and stone flounder ( Kareius bicoloratus ) in North China revealed virus infection in the bodies of the dead and diseased fish. These viruses included the lymphocystis disease virus (LDV), parvovirus, globular virus, and a kind of baculavirus which was not discovered and reported before and is now tentatively named baculavirus of stone flounder ( Kareius bicoloratus ).
文摘The objective of this study was to systematically review the literature about the use of the operating microscope in endodontics. It used sources of bibliographic cataloging electronically identified by MEDLINE via PubMed, LILACS, BBO and Scopus, using as descriptors: Endodontics, anatomy and microscopy. The selected articles were identified from the titles and abstracts, taking into consideration the following criteria: publications ranging from January 2001 to November 2012, case reports, published in an indexed journal, and publications in English language. The search showed 167 articles related to this topic, and these 21 articles met the inclusion criteria. These indicated that a higher magnification helps coronary access and the location of channels to identify and interpret the complexities of the anatomy of root canals, the removal of nuclei and intracoronary fractured instruments, to minimize trauma of surgeries in soft and hard tissues, and detect fractures and microfractures. It was found that its use has provided Endodontics with a significant improvement in vision of the operative field, offering better quality jobs and a higher success rate.