An error analysis of the dynamic shear modulus of stiff specimens from tests performed by a new resonant column device developed by the Institute of Engineering Mechanics, China was conducted. A modified approach for ...An error analysis of the dynamic shear modulus of stiff specimens from tests performed by a new resonant column device developed by the Institute of Engineering Mechanics, China was conducted. A modified approach for calculating the dynamic shear modulus of the stiff specimens is presented. The error formula of the tests was deduced and parameters that impact the accuracy of the test were identified. Using six steel specimens with known standard stiffness as a base, a revised dynamic shear modulus calculation for stiff specimens was formulated by comparing three of the models. The maximum error between the test results and the calculated results shown by curves from both the free-vibration and the resonant-vibration tests is less than 6%. The free-vibration and resonant-vibration tests for three types of stiff samples with a known modulus indicate that the maximum deviation between the actual and the tested value using the modified approach were less than 10%. As a result, the modified approach presented here is shown to be reliable and the new device can be used for testing dynamic shear modulus of any stiff materials at low shear strain levels展开更多
Objective: To evaluate the accuracy of glomerular filtration rate formula by comparising the CKD-EPI 2009 formula and the modified Modified MDRD formula with the 99mTc-DTPA double-phase plasma method as "gold sta...Objective: To evaluate the accuracy of glomerular filtration rate formula by comparising the CKD-EPI 2009 formula and the modified Modified MDRD formula with the 99mTc-DTPA double-phase plasma method as "gold standard" respectively. Methods: Totally 166 patients diognosed as chronic kidney disease (CKD) were enrolled. The 99mTc-DTPA double-plasma method (rGFR) was used as the "gold standard". The CKD-EPI 2009 formula and the modified MDRD formula were used to calculate eGFR. Statistical software was used to analyze the correlation between the calculated values of the two formulas and the gold standard value and the bias. Then we evaluated the accuracy of the two GFR formulas. Results: Among the CKD stage 1 patients, the bias of the CKD-EPI 2009 formula was smaller than that of the Modified MDRD formula (13.9911.45;20.1815.90);both formulas were weakly correlated with the gold standard (correlation coefficients were 0.216, 0.229, P<0.01, respectively);The probability that the bias of the calculated value of the CKD-EPI 2009 formula less than 15%, 30%, and 50% of the gold standard value is smaller. Among the CKD stage 2 patients, the bias of the CKD-EPI 2009 formula was smaller than that of the Modified MDRD formula (12.748.45;15.6811.01);both formulas were moderately correlated with the gold standard (correlation coefficients were 0.568, 0.581, P<0.01, respectively);The probability that the bias of the calculated value of the CKD-EPI 2009 formula less than 15%, 30%, and 50% of the gold standard value is smaller. Among the CKD stage 3 patients, the bias of the CKD-EPI 2009 formula was smaller than that of the Modified MDRD formula (12.6410.27;12.8810.97), and both formulas were strongly correlated with the gold standard (correlation coefficients were 0.664, 0.670, P<0.01, respectively);The probability that the bias of the calculated value of the Modified MDRD formula less than 15%, 30%, and 50% of the gold standard value is smaller. Among the CKD stage 4 to 5 patients, the bias of the CKD-EPI 2009 formula was smaller than that of the Modified MDRD formula (5.585.36;5.945.20);The CKD-EPI 2009 formula and the Modified MDRD formula were strongly correlated with the gold standard (correlation coefficient r was 0.808. 0.802, P<0.01, respectively);The probability of the bias of the calculated value of the CKD-EPI 2009 formula less than 15%, 30%, and 50% of the gold standard value is smaller. In patients with decreased renal function with GFR <60 ml/min, the sensitivity and positive predictive value of the CKD-EPI 2009 formula for the diagnosis of "decreased renal function"were higher, and the specificity was comparable. Conclusion: 1. When the renal function is only slightly decreased, the accuracy of the two formulas is not good. In this condition, the CKD-EPI 2009 formula is more accurate and recommended. 2. It is necessary to further improve the current formulas especialy when it comes to value the slightly declined renal function;3. When we try to identify the stage of CKD patients, only based on eGFR may cause misclassification, it is recommended to combine the cause-GFR-albuminuria staging to assess the stage of CKD;4. The current formulas have limitations.in the case that requires a highly accurate assessment of GFR, the 99mTc-DTPA dual plasma method is recommended.展开更多
The quarter-circular caisson breakwater (QCB) is a new type of breakwater, and it can be applied in deepwater. The stability of QCB under wave force action can be enhanced, and the rubble mound engineering can be le...The quarter-circular caisson breakwater (QCB) is a new type of breakwater, and it can be applied in deepwater. The stability of QCB under wave force action can be enhanced, and the rubble mound engineering can be less than that of semi-circular breakwaters in deepwater. In order to study the wave force distribution acting on the QCB, to find wave force formula for this type of breakwater, firstly in this paper, the distribution characteristics of the horizontal force, the downward vertical force and the uplift force on the breakwater were gotten based on physical model wave flume experiments and on the analysis of the wave pressure experimental data. Based on a series of physical model tests acted by irregular waves, a kind of calculation method, which was modified by Goda formula, was proposed to carry out the wave force on the QCB. Secondly, the reliability method with correlated variables was adopted to analyze the QCB, considering the high correlation between wave forces or moments. Utilizing the observed wave data in engineering field, the reliability index and failure probability of QCB were obtained. Finally, a factor Q=0.9 is given to modify the zero pressure height above SWL of QCB, and wave force partial coefficient 1.34 to the design expressions of QCB for anti-sliding, as well as 1.67 for anti-overturning, were presented.展开更多
With the increasing researches on geotechnical properties of the diesel contaminated soil( DCS),the water content measured is indispensable part during the early period. In this study,the relative error of water conte...With the increasing researches on geotechnical properties of the diesel contaminated soil( DCS),the water content measured is indispensable part during the early period. In this study,the relative error of water content measurement using the traditional method is as high as 20. 78%,which is no longer suitable for contaminated soil. Through a series of tests to measure the loss coefficient of diesel in the drying time,the authors finally proposed a modified calculation formula for test samples. The results show that the maximum relative error calculated by using the modified formula is 0. 96%,far lower than that of traditional formula,which can provide accurate data for further study of diesel contaminated soil.展开更多
Several researchers have dealt with the one-dimensional fractional heat conduction equation in the last decades,but as far as we know,no one has investigated such a problem from the perspective of developing suitable ...Several researchers have dealt with the one-dimensional fractional heat conduction equation in the last decades,but as far as we know,no one has investigated such a problem from the perspective of developing suitable fractional-order methods.This has actually motivated us to address this problem by the way of establishing a proper fractional approach that involves employing a combination of a novel fractional difference formula to approximate the Caputo differentiator of orderαcoupled with the modified three-point fractional formula to approximate the Caputo differentiator of order 2α,where 0<α≤1.As a result,the fractional heat conduction equation is then reexpressed numerically using the aforementioned formulas,and by dividing the considered mesh into multiple nodes,a system is generated and algebraically solved with the aid of MATLAB.This would allow us to obtain the desired approximate solution for the problem at hand.展开更多
基金Ministry of Science and Technology of Chinaand the Earthquake Science Foundation of China Under GrandNo.102033
文摘An error analysis of the dynamic shear modulus of stiff specimens from tests performed by a new resonant column device developed by the Institute of Engineering Mechanics, China was conducted. A modified approach for calculating the dynamic shear modulus of the stiff specimens is presented. The error formula of the tests was deduced and parameters that impact the accuracy of the test were identified. Using six steel specimens with known standard stiffness as a base, a revised dynamic shear modulus calculation for stiff specimens was formulated by comparing three of the models. The maximum error between the test results and the calculated results shown by curves from both the free-vibration and the resonant-vibration tests is less than 6%. The free-vibration and resonant-vibration tests for three types of stiff samples with a known modulus indicate that the maximum deviation between the actual and the tested value using the modified approach were less than 10%. As a result, the modified approach presented here is shown to be reliable and the new device can be used for testing dynamic shear modulus of any stiff materials at low shear strain levels
文摘Objective: To evaluate the accuracy of glomerular filtration rate formula by comparising the CKD-EPI 2009 formula and the modified Modified MDRD formula with the 99mTc-DTPA double-phase plasma method as "gold standard" respectively. Methods: Totally 166 patients diognosed as chronic kidney disease (CKD) were enrolled. The 99mTc-DTPA double-plasma method (rGFR) was used as the "gold standard". The CKD-EPI 2009 formula and the modified MDRD formula were used to calculate eGFR. Statistical software was used to analyze the correlation between the calculated values of the two formulas and the gold standard value and the bias. Then we evaluated the accuracy of the two GFR formulas. Results: Among the CKD stage 1 patients, the bias of the CKD-EPI 2009 formula was smaller than that of the Modified MDRD formula (13.9911.45;20.1815.90);both formulas were weakly correlated with the gold standard (correlation coefficients were 0.216, 0.229, P<0.01, respectively);The probability that the bias of the calculated value of the CKD-EPI 2009 formula less than 15%, 30%, and 50% of the gold standard value is smaller. Among the CKD stage 2 patients, the bias of the CKD-EPI 2009 formula was smaller than that of the Modified MDRD formula (12.748.45;15.6811.01);both formulas were moderately correlated with the gold standard (correlation coefficients were 0.568, 0.581, P<0.01, respectively);The probability that the bias of the calculated value of the CKD-EPI 2009 formula less than 15%, 30%, and 50% of the gold standard value is smaller. Among the CKD stage 3 patients, the bias of the CKD-EPI 2009 formula was smaller than that of the Modified MDRD formula (12.6410.27;12.8810.97), and both formulas were strongly correlated with the gold standard (correlation coefficients were 0.664, 0.670, P<0.01, respectively);The probability that the bias of the calculated value of the Modified MDRD formula less than 15%, 30%, and 50% of the gold standard value is smaller. Among the CKD stage 4 to 5 patients, the bias of the CKD-EPI 2009 formula was smaller than that of the Modified MDRD formula (5.585.36;5.945.20);The CKD-EPI 2009 formula and the Modified MDRD formula were strongly correlated with the gold standard (correlation coefficient r was 0.808. 0.802, P<0.01, respectively);The probability of the bias of the calculated value of the CKD-EPI 2009 formula less than 15%, 30%, and 50% of the gold standard value is smaller. In patients with decreased renal function with GFR <60 ml/min, the sensitivity and positive predictive value of the CKD-EPI 2009 formula for the diagnosis of "decreased renal function"were higher, and the specificity was comparable. Conclusion: 1. When the renal function is only slightly decreased, the accuracy of the two formulas is not good. In this condition, the CKD-EPI 2009 formula is more accurate and recommended. 2. It is necessary to further improve the current formulas especialy when it comes to value the slightly declined renal function;3. When we try to identify the stage of CKD patients, only based on eGFR may cause misclassification, it is recommended to combine the cause-GFR-albuminuria staging to assess the stage of CKD;4. The current formulas have limitations.in the case that requires a highly accurate assessment of GFR, the 99mTc-DTPA dual plasma method is recommended.
基金Supported by the Natural Science Foundation of Hebei Province (Grant No. E2012201057) the Scientific and Technological Projects of Hebei Province (Grant No. 2009056) the Natural Science Foundation of Tianjin (Grant No. 10JCYBJC03700)
文摘The quarter-circular caisson breakwater (QCB) is a new type of breakwater, and it can be applied in deepwater. The stability of QCB under wave force action can be enhanced, and the rubble mound engineering can be less than that of semi-circular breakwaters in deepwater. In order to study the wave force distribution acting on the QCB, to find wave force formula for this type of breakwater, firstly in this paper, the distribution characteristics of the horizontal force, the downward vertical force and the uplift force on the breakwater were gotten based on physical model wave flume experiments and on the analysis of the wave pressure experimental data. Based on a series of physical model tests acted by irregular waves, a kind of calculation method, which was modified by Goda formula, was proposed to carry out the wave force on the QCB. Secondly, the reliability method with correlated variables was adopted to analyze the QCB, considering the high correlation between wave forces or moments. Utilizing the observed wave data in engineering field, the reliability index and failure probability of QCB were obtained. Finally, a factor Q=0.9 is given to modify the zero pressure height above SWL of QCB, and wave force partial coefficient 1.34 to the design expressions of QCB for anti-sliding, as well as 1.67 for anti-overturning, were presented.
文摘With the increasing researches on geotechnical properties of the diesel contaminated soil( DCS),the water content measured is indispensable part during the early period. In this study,the relative error of water content measurement using the traditional method is as high as 20. 78%,which is no longer suitable for contaminated soil. Through a series of tests to measure the loss coefficient of diesel in the drying time,the authors finally proposed a modified calculation formula for test samples. The results show that the maximum relative error calculated by using the modified formula is 0. 96%,far lower than that of traditional formula,which can provide accurate data for further study of diesel contaminated soil.
文摘Several researchers have dealt with the one-dimensional fractional heat conduction equation in the last decades,but as far as we know,no one has investigated such a problem from the perspective of developing suitable fractional-order methods.This has actually motivated us to address this problem by the way of establishing a proper fractional approach that involves employing a combination of a novel fractional difference formula to approximate the Caputo differentiator of orderαcoupled with the modified three-point fractional formula to approximate the Caputo differentiator of order 2α,where 0<α≤1.As a result,the fractional heat conduction equation is then reexpressed numerically using the aforementioned formulas,and by dividing the considered mesh into multiple nodes,a system is generated and algebraically solved with the aid of MATLAB.This would allow us to obtain the desired approximate solution for the problem at hand.