期刊文献+
共找到21篇文章
< 1 2 >
每页显示 20 50 100
Design and implementation of the monochromator shielding for the cold neutron spectrometers XINGZHI and BOYA
1
作者 汪晋辰 刘娟娟 +6 位作者 徐大业 Florian Grünauer 郝丽杰 刘蕴韬 张红霞 程鹏 鲍威 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第5期96-102,共7页
An innovative monochromator shielding is designed and implemented for the cold neutron spectrometers XINGZHI and BOYA operated by Renmin University of China at China Advanced Research Reactor.Via Monte Carlo simulatio... An innovative monochromator shielding is designed and implemented for the cold neutron spectrometers XINGZHI and BOYA operated by Renmin University of China at China Advanced Research Reactor.Via Monte Carlo simulations and careful mechanical designs,a shielding configuration has been successfully developed to satisfy safety requirements of below 3μSv/h dose rate at its exterior,meanwhile fulfilling space,floor load and nonmagnetic requirements.Composite materials are utilized to form the sandwich-type shielding walls:the inner layer of boron carbide rubber,the middle layer of steel-encased lead and the outer layer of borated polyethylene.Special-shaped liftable shielding blocks are incorporated to facilitate a continuous adjustment of the neutron energy while preventing radiation leakage.Our work has demonstrated that by utilizing composite shielding materials,along with the sandwich structure and liftable shielding blocks,a compact and lightweight shielding solution can be achieved.This enables the realization of advanced neutron scattering instruments that provide expanded space of measurement,larger energy and momentum coverage,and higher flux on the sample.This shielding represents the first of its kind in neutron scattering instruments in China.Following its successful operation,it has been subsequently employed by other neutron instruments across the country. 展开更多
关键词 neutron scattering cold neutron spectrometer monochromator shielding sandwich shielding structure
原文传递
Operando measurement of lattice deformation profiles of synchrotron radiation monochromator
2
作者 Yue Zhang Zhong-Liang Li +4 位作者 Shang-Yu Si Lian Xue Hong-Xin Luo Xiao-Wei Zhang Jun Hu 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第7期8-19,共12页
This study presents a new method for characterizing the thermal lattice deformation of a monochromator with high precision under service conditions and first reports the operando measurements of nanoscale thermal latt... This study presents a new method for characterizing the thermal lattice deformation of a monochromator with high precision under service conditions and first reports the operando measurements of nanoscale thermal lattice deformation on a double-crystal monochromator at different incident powers.The nanoscale thermal lattice deformation of the monochromator first crystal was obtained by analyzing the intensity of the distorted DuMond diagrams.DuMond diagrams of the 333 diffraction index,sensitive to lattice deformation,were obtained directly using a 2D detector and an analyzer crystal orthogonal to the monochromator.With increasing incident power and power density,the maximum height of the lattice deformation increased from 3.2 to 18.5 nm,and the deformation coefficient of the maximum height increased from 1.1 to 3.2 nm/W.The maximum relative standard deviation was 4.2%,and the maximum standard deviation was 0.1 nm.Based on the measured thermal deformations,the flux saturation phenomenon and critical point for the linear operation of the monochromator were predicted with increasing incident power.This study provides a simple solution to the problem of the lower precision of synchrotron radiation monochromator characterizations compared to simulations. 展开更多
关键词 Synchrotron radiation monochromator Lattice deformation X-ray dynamic diffraction
下载PDF
Optical design of the time-resolved ARPES beamline of the new material spectroscopy experimental station for the update of CAEP THz-FEL facility
3
作者 Liang-Liang Du Li-Min Meng +1 位作者 Jiang Li Li-Guo Zhu 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第11期70-74,共5页
The Chinese Academy of Engineering Physics Terahertz Free Electron Laser Facility(CAEP THz FEL,CTFEL)is the only high-average power free electron laser terahertz source based on superconducting accelerators in China.T... The Chinese Academy of Engineering Physics Terahertz Free Electron Laser Facility(CAEP THz FEL,CTFEL)is the only high-average power free electron laser terahertz source based on superconducting accelerators in China.The update of the CTFEL is now undergoing and will expand the frequency range from 0.1–4.2 THz to 0.1–125 THz.Two experimental stations for material spectroscopy and biomedicine will be built.A high harmonic generation(HHG)lightsource based beamline at the material spectroscopy experimental station for time-resolved angle-resolved photoemission spectroscopy(ARPES)research will be constructed and the optical design is presented.The HHG lightsource covers the extreme ultraviolet(XUV)photon energy range of 20–50 eV.A Czerny–Turner monochromator with two plane gratings worked in conical diffraction configuration is employed to maintain the transmission efficiency and preserve the pulse time duration.The calculated beamline transmission efficiency is better than 5%in the whole photon energy range.To our knowledge,this is the first time in China to combine THz-infrared FEL with HHG light source,and this experimental station will be a powerful and effective instrument that will give new research opportunities in the future for users doing research on the dynamic evolution of the excited electron band structure of a material’s surface. 展开更多
关键词 high harmonic generation(HHG) femtosecond extreme ultraviolet pulse conical diffraction grating monochromator transient spectral experiment
原文传递
Monochromatic X-ray-induced thermal effect on four-reflection“nested” me V-monochromators: dynamical diffraction theory and finite-element analysis
4
作者 胡凌飞 高立丹 +4 位作者 李贞杰 王山峰 盛伟繁 刘鹏 徐伟 《Chinese Physics C》 SCIE CAS CSCD 2015年第9期83-89,共7页
The high energy resolution monochromator (HRM) is widely used in inelastic scattering programs to detect phonons with energy resolution, down to the meV level. Although the large amount of heat from insertion device... The high energy resolution monochromator (HRM) is widely used in inelastic scattering programs to detect phonons with energy resolution, down to the meV level. Although the large amount of heat from insertion devices can be reduced by a high heat-load monochromator, the unbalanced heat load on the inner pair of crystals in a nested HRM can affect its overall performance. Here, a theoretical analysis of the unbalanced heat load using dynamical diffraction theory and finite element analysis is presented. By utilizing the ray-tracing method, the performance of different HRM nesting configurations is simulated. It is suggested that the heat balance ratio, energy resolution, and overall spectral transmission efficiency are the figures of merit for evaluating the performance of nested HRMs. Although the present study is mainly focused on nested HRMs working at 57Fe nuclear resonant energy at 14.4 keV, it is feasible to extend this to other nested HRMs working at different energies. 展开更多
关键词 dynamical diffraction theory high energy resolution monochromator heat load
原文传递
Small d-spacing WSi_2/Si multilayers for X-ray monochromators
5
作者 黄秋实 李浩川 +2 位作者 朱京涛 王占山 唐永建 《Chinese Optics Letters》 SCIE EI CAS CSCD 2012年第12期87-90,共4页
A WSi2/Si multilayer, with 300 bi-layers and a 2.18-nm d-spacing, is designed for X-ray monochroma- tor application. The nmltilayer is deposited using direct current magnetron sputtering technology. The reflectivity o... A WSi2/Si multilayer, with 300 bi-layers and a 2.18-nm d-spacing, is designed for X-ray monochroma- tor application. The nmltilayer is deposited using direct current magnetron sputtering technology. The reflectivity of the 1st-order Bragg peak measured at E = 8.05 keV is 38%, and the angular resolution (△θ/θ) is less than 1.0%. Fitting results of the reflectivity curve indicate a layer thickness drift of 1.6%, mainly accounting for the broadening of the Bragg peaks. The layer morphology is further characterized by transmission electron microscopy, and a well-ordered multilayer structure with sharp interfaces is observed from the substrate to the surface. The material combination of WSi2/Si is a promising candidate for the fabrication of a high-resolution nmltilayer monochromator in the hard X-ray region. 展开更多
关键词 Curve fitting Interfaces (materials) monochromatorS REFLECTION Silicon Transmission electron microscopy X ray diffraction X rays
原文传递
LO-RAY-LIGH@ Diffraction Gratings in UV-VIS Spectroscopy
6
作者 Uwe Oppermann Marion Egelkraut-Holtus Tatsuyoshi Fujiwara 《Journal of Chemistry and Chemical Engineering》 2013年第12期1117-1120,共4页
It has been more than half a century since the release of the first Shimadzu UV-VIS (UV-visible) spectrophotometer QB-50 in 1952, and during this time more than 160,000 UV-VIS spectrometers have been produced and in... It has been more than half a century since the release of the first Shimadzu UV-VIS (UV-visible) spectrophotometer QB-50 in 1952, and during this time more than 160,000 UV-VIS spectrometers have been produced and installed in a wide variety of different applications. A lot of technical innovations have been implemented to improve the performance and significantly reduce the stray light levels. The latest innovation during development of sophisticated spectrophotometers is based on a new holographic exposure method and optimized etching process which has made it possible to produce both high-efficient and exceptionally low stray light gratings. These LO-RAY-LIGH~ gratings have guaranteed values of stray light at the intermediate position between zero-order and first-order lights. The values are measured by Shimadzu's laser stray-light-measuring system. The latest development in the series of UV-VIS spectrophotometers is the UV-2700 which is a true double beam double monochromator system in a compact design for high-precision spectral analysis of a wide range of samples including organic and inorganic compounds, biological samples, optical materials and photovoltaics. The high performance optical system is designed with "LO-RAY-LIGH" diffraction gratings, featuring highest efficiency and exceptionally low stray light. The spectrophotometer operates in the wavelength range from 185 nm to 900 nm and allows highly sophisticated applications such as direct measurement of high density samples up to 8 absorbance units without dilution. 展开更多
关键词 LO-RAY-LIGH stray light diffraction grating SPECTROPHOTOMETER single monochromator holographic grating highefficiency double monochromator.
下载PDF
The development,performances and applications of the monochromatic X-rays facilities in(0.218–301)keV at NIM,China 被引量:5
7
作者 Si-Ming Guo Jin-Jie Wu Dong-Jie Hou 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2021年第6期108-121,共14页
Space scientific exploration is rapidly becoming the primary battlefield for humankind to explore the universe.Countries worldwide have launched numerous space exploration satellites.Accurate calibration of the detect... Space scientific exploration is rapidly becoming the primary battlefield for humankind to explore the universe.Countries worldwide have launched numerous space exploration satellites.Accurate calibration of the detectors on the ground is a crucial element for space science satellites to obtain observational results.For the purpose of providing calibration for various satellite-borne detectors,multiple monochromatic X-rays facilities have been built at the National Institute of Metrology,P.R.China(NIM).These facilities mainly pertain to grating diffraction and Bragg diffraction,and the energy range of the produced monochromatic X-rays is 0.218–301 ke V.These facilities have a high performance in terms of energy stability,monochromaticity,and flux stability.The monochromaticity was greater than 3.0%.The energy stability of the facility is 0.02%at 25 ke V over 8 h,and the flux stability was within 1.0%at 25 ke V over 8 h.Calibration experiments on the properties of satellite-borne detectors,such as energy linearity,energy resolution,detection efficiency,and temperature response,can be conducted at the facilities.Thus far,the calibration of two satellites has been completed by the authors,and the work on three other satellites is in progress.This study will contribute to the advancement of X-ray astronomy the development of Chinese space science. 展开更多
关键词 Monochromatic X-rays monochromator Bragg diffraction Energy spectra Calibration
下载PDF
High Spectral Resolution Mo/Si Multilayers Working at High Order Reflection 被引量:1
8
作者 吴文娟 朱京涛 +13 位作者 王占山 张众 王风丽 王洪昌 张淑敏 徐垚 程鑫彬 王蓓 李存霞 吴永荣 秦树基 陈玲燕 周洪军 霍同林 《Chinese Physics Letters》 SCIE CAS CSCD 2006年第9期2534-2537,共4页
The high reflectance orders are used to improve the spectral resolution of Mo/Si multilayers. The multilayers for the first-, second- and third-order reflectance are designed and optimized, respectively. These multila... The high reflectance orders are used to improve the spectral resolution of Mo/Si multilayers. The multilayers for the first-, second- and third-order reflectance are designed and optimized, respectively. These multilayers are fabricated by using a directed current magnetron sputtering system, and the reflectivity is measured in an extreme ultraviolet range by synchrotron radiation. The experimental results show that the spectral resolution λ/Δλ(λ= 14 nm) increases from 24.6 for the first order to 66.6 for the third order. 展开更多
关键词 DESIGN monochromator FABRICATION FILMS
原文传递
High-speed VUV spectroscopy for edge impurity line emission measurements in HL-2A tokamak 被引量:1
9
作者 Dianlin ZHENG Kai ZHANG +7 位作者 Zhengying CUI Ping SUN Chunfeng DONG Ping LU Bingzhong FU Zetian LIU Zhongbing SHI Qingwei YANG 《Plasma Science and Technology》 SCIE EI CAS CSCD 2018年第10期75-83,共9页
A 20 cm focal length normal incidence vacuum ultraviolet (VUV_20 cm) monochromator with a fast time response has been developed for measuring edge impurity line emission in the wavelength range of 300-2000 A on an H... A 20 cm focal length normal incidence vacuum ultraviolet (VUV_20 cm) monochromator with a fast time response has been developed for measuring edge impurity line emission in the wavelength range of 300-2000 A on an HL-2A tokamak. An aberration corrected concave holographic grating with 1200 grooves/mm is adopted in the monochromator, which provides a wavelength dispersion of 40 A mm-1. The aperture is f/4.5. A channel electron multiplier is used as a detector. The time resolution of the system is 17 μs. Wavelength calibration of the system has been done by using a hollow cathode light source in the laboratory with helium and argon gases. The obtained signals of helium and argon spectra are very strong since the inner surface of the monochromator vacuum chamber is blackened and the stray light level is then significantly reduced. The optical property of the system has been examined by scanning the width of the entrance and exit slits. The system is then installed at the mid-port of the HL-2A tokamak and typical line emissions from the HL-2A plasma are measured. Time behaviors of edge impurity line emissions are observed with the fast time response system in different plasma confinement regimes, especially in the H-mode discharges. The result shows that the VUV_20 cm system works very well to measure the edge impurity line emissions in the edge localized modes phase of H-mode discharges. 展开更多
关键词 VUV monochromator CEM detector wavelength calibration impurity line emission H-mode plasmas
下载PDF
A tunable XUV monochromatic light source based on the time preserving grating selection of high-order harmonic generation
10
作者 牛永 梁红静 +3 位作者 刘燚 刘方圆 马日 丁大军 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第7期194-198,共5页
We accomplish a laboratory facility for producing a femtosecond XUV coherent monochromatic radiation with a broad tunable spectral range of 20 eV-75 eV. It is based on spectral selected single-order harmonics from int... We accomplish a laboratory facility for producing a femtosecond XUV coherent monochromatic radiation with a broad tunable spectral range of 20 eV-75 eV. It is based on spectral selected single-order harmonics from intense laser driven high harmonic generation in gas phase. The time preserving for the selected harmonic radiation is achieved by a Czerny-Turner type monochromator designed with a conical diffraction grating mount for minimizing the time broadening caused by grating diffraction and keeping a relatively high diffraction efficiency. Our measurement shows that the photon flux of the 23-order harmonic(H23) centered at 35.7 eV is 1×10~9 photons/s approximately with a resolving power E/?E ≈ 36.This source provides an ultrashort tunable monochromatic XUV beam for ultrafast studies of electronic and structural dynamics in a large variety of matters. 展开更多
关键词 high harmonic generation conical diffraction time preserving monochromator femtosecond extreme ultraviolet pulse
原文传递
Higher order harmonics suppression in extreme ultraviolet and soft x-ray
11
作者 陈勇 魏来 +6 位作者 钱凤 杨祖华 王少义 巫殷忠 张强强 范全平 曹磊峰 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第2期344-348,共5页
The extreme ultraviolet and soft x-ray sources are widely used in various domains. Suppressing higher order harmonics and improving spectral purity are significant. This paper describes a novel method of higher order ... The extreme ultraviolet and soft x-ray sources are widely used in various domains. Suppressing higher order harmonics and improving spectral purity are significant. This paper describes a novel method of higher order harmonics suppression with single order diffraction gratings in extreme ultraviolet and soft x-ray. The principle of harmonic suppression with single order diffraction grating is described, and an extreme ultraviolet and soft x-ray non-harmonics grating monochromator is designed based on the single order diffraction grating. The performance is simulated by an optical design software. The emergent beams of a monochromator with different gratings are measured by a transmission grating spectrometer. The results show that the single order diffraction grating can suppress higher order harmonics effectively, and it is expected to be widely used in synchrotron radiation, diagnostics of laser induced plasma, and astrophysics. 展开更多
关键词 higher order harmonics suppression extreme ultraviolet and soft x-ray monochromator single order diffraction grating
原文传递
X-Ray Powder Diffraction: Why Not Use CuKβ Radiation?
12
作者 Hans Hermann Otto 《Journal of Analytical Sciences, Methods and Instrumentation》 2018年第3期37-47,共11页
CuKβ radiation with a wavelength of λ = 1.3923 ? is recommended for crystal structure determination from X-ray powder diffraction using the Rietfeld method. A highly sensitive image plate detector is able to collect... CuKβ radiation with a wavelength of λ = 1.3923 ? is recommended for crystal structure determination from X-ray powder diffraction using the Rietfeld method. A highly sensitive image plate detector is able to collect enough intensity to record a brilliant X-ray powder pattern in a reasonable time, compared to CuKα1 radiation used today. Especially atomic displacement coefficients could be determined more precisely with the much greater number of reflections recorded. A double-radius Guinier camera attached to a micro-focus rotating anode tube ensures increased brilliance besides high resolution. A simple construction specification is presented to make smart cylindrically bent Ge(111) or Si(111) X-ray monochromators that deliver focused CuKβ radiation. The highly linear response of image plate detectors allows removing of fluorescence radiation simply as background of the pattern. The proposed equipment is a cost-efficient alternative to a liquid gallium-metal-jet X-ray source with maximum power load and a similar wavelength of λ(GaKα1) = 1.34013 ?. 展开更多
关键词 X-RAY DIFFRACTION Rietfeld Analysis CuKβ RADIATION Guinier Method FOCUSING monochromatorS X-RAY DIFFRACTION Equipment Construction
下载PDF
Color 3D Reverse Engineering 被引量:3
13
作者 XU Zhi-qin 1, YE Sheng-hua 1, FAN Guang-zhao 2 (1. School of Precision Instrument and Opto-electronics Engineering, N ational Key Lab of Measurement Technology and Instrument, EMC, Tianjin University, Tianjin, China 2. Department of Mechanical Engineering, National Taiwan University, Taiwan, Chi na) 《厦门大学学报(自然科学版)》 CAS CSCD 北大核心 2002年第S1期152-,共1页
This paper presents a principle and a method of col or 3D laser scanning measurement. Based on the fundamental monochrome 3D measureme nt study, color information capture, color texture mapping, coordinate computati o... This paper presents a principle and a method of col or 3D laser scanning measurement. Based on the fundamental monochrome 3D measureme nt study, color information capture, color texture mapping, coordinate computati on and other techniques are performed to achieve color 3D measurement. The syste m is designed and composed of a line laser light emitter, one color CCD camera, a motor-driven rotary filter, a circuit card and a computer. Two steps in captu ring object’s images in the measurement process: First, the color CCD camera ta kes the color picture of the object to be used for texture mapping in post proce ssing. Secondly, the monochrome data of the object is taken. The laser light emi tter is started; the light plane and the surface of the object intersect to form an undulate line, which forms an image on the CCD sensor. After the optic- electronics transformation, the electronic signals are captured and send to the computer. A new color 3D measurement model was derived, and a rapid calibra ting method to measure the system parameters was proposed--optical plane equat ion calibrating method. A calibrating drone was designed and built. 3D color sca nning system not only provides an object’s individual point information in the 3D coordinate, in the mean time, it provides the color information of each indiv idual point. This paper also advances a multi-frame auto-merging method, i.e. several frames of color 3D digital images measured are merged quickly according to their curvature characteristics and RGB information. Initial matching and fin e tune of the registration are completely performed by the computer; initial mat ching is via user interface in helping computer to find the transformation matri x. The transformation matrix is found according to the geometric characteristics chosen by hand. After the initial transformation matrix is found, fine tune of the registration is preformed to do the optimum adjustment to achieve a complete color textured 3D model. The system can be broadly used in the fields of produc t design, mold manufacture, multimedia, game development, animation, medical eng ineering, antique digitization, etc. 展开更多
关键词 monochrome 3D color 3D optical plane equation surface merging reverse engineering
下载PDF
黑白传奇 徕卡M Monochrome深度评测
14
作者 王雷 《影像视觉》 2015年第9期102-104,共3页
拥有一部数码相机却只能拍摄黑白影像似乎是一件很疯狂的事,然而徕卡在2012年提出了M Monochrome的创意,这部黑白旁轴相机在2015年迎来了更新换代。最显著的升级是传感器由1800万像素CCD变成了2400万像素CMOS。这一改进提高了分辨率,而... 拥有一部数码相机却只能拍摄黑白影像似乎是一件很疯狂的事,然而徕卡在2012年提出了M Monochrome的创意,这部黑白旁轴相机在2015年迎来了更新换代。最显著的升级是传感器由1800万像素CCD变成了2400万像素CMOS。这一改进提高了分辨率,而且借助CMOS技术意味着M Monochome拥有了实时取景显示以及拍摄1080p全高清视频的能力。 展开更多
关键词 徕卡 M Monochrome 旁轴相机 实时取景 噪点 曝光补偿 感光度范围 尼康 高清视频 感光元件
下载PDF
浅析富士monochrome instax mini
15
作者 杜孝贞 魏令权 +3 位作者 张洪磊 卢志凯 黄海水 赵亮 《信息记录材料》 2024年第12期6-9,共4页
本文对富士monochrome instax mini的微观结构进行了分析,并对涂层结构和影像形成机理进行了剖析。结果表明:富士monochrome instax mini含有多个功能涂层,结构复杂,采用正性乳剂技术、特殊显影加工技术、染料释放扩散技术以及染料固定... 本文对富士monochrome instax mini的微观结构进行了分析,并对涂层结构和影像形成机理进行了剖析。结果表明:富士monochrome instax mini含有多个功能涂层,结构复杂,采用正性乳剂技术、特殊显影加工技术、染料释放扩散技术以及染料固定等技术手段,通过染料的扩散叠加形成黑白影像。制作monochrome instax mini需要掌握彩色一次成像相关技术,制作难度偏大。 展开更多
关键词 monochrome instax mini 涂层结构 正性乳剂 染料 扩散叠加 黑白影像
下载PDF
X-ray diffraction performance of thermally distorted crystals
16
作者 Chuan Yang Tao Liu +5 位作者 Kai Hu Ye Zhu Xiaohao Dong Zhongmin Xu Chao Feng Weiqing Zhang 《High Power Laser Science and Engineering》 SCIE CAS CSCD 2023年第6期29-38,共10页
The development of high-brightness X-ray free electron lasers(XFELs),such as hard X-ray self-seeding free electron lasers and XFEL oscillators(XFELOs),brings a severe challenge to the crystal monochromator due to a st... The development of high-brightness X-ray free electron lasers(XFELs),such as hard X-ray self-seeding free electron lasers and XFEL oscillators(XFELOs),brings a severe challenge to the crystal monochromator due to a strong nonuniform thermal load.The distortion caused by spatial temperature gradients can severely affect the optical performance of crystals.Therefore,this paper presents a model to estimate the performance of non-uniform thermally distorted crystals.The model not only takes into account thermal strain,slope error and incident angle deviation,but also considers temperature-dependent factors such as the Debye-Waller factor and electric susceptibility.Our investigation indicates that the Debye-Waller factor reduces the height and bandwidth of rocking curves,and the impact of the electric susceptibility is tiny.The proposed model can describe the distortion of the reflectivity and transmissivity curves of nonuniform thermally loaded crystals and can be applied in the design of crystal monochromators,crystal splitters,crystal compressors and XFELOs. 展开更多
关键词 crystal monochromator free electron laser thermal load X-ray diffraction
原文传递
Design of an efficient monochromatic electron source for inverse photoemission spectroscopy 被引量:1
17
作者 耿东平 杨迎国 +2 位作者 刘树虎 洪才浩 高兴宇 《Chinese Physics C》 SCIE CAS CSCD 2014年第11期115-120,共6页
A design for an efficient monochromatic electron source for Inverse Photoemission Spectroscopy (IPES) apparatus is described. The electron source consists of a BaO cathode, a focus electrostatic lens, a hemispherica... A design for an efficient monochromatic electron source for Inverse Photoemission Spectroscopy (IPES) apparatus is described. The electron source consists of a BaO cathode, a focus electrostatic lens, a hemispherical deflection monochromator (HDM), and a transfer electrostatic lens. The HDM adopts a “slit-in and slit-out” structure and the degradation of first-order focusing is corrected by two electrodes between the two hemispheres, which has been investigated by both analytical methods and electron-ray tracing simulations using the SIMION program. Through the focus lens, the HDM, and the standard five-element transfer lens, an optimal energy resolution is estimated to be about 53 MeV with a beam flux of 27 μA. Pass energy (P.E.) of 10 eV and 5 eV are discussed, respectively. 展开更多
关键词 beam flux electrostatic lens hemispherical deflection monochromator fringing effect energy resolu-tion SIMION
原文传递
All-optical realization of × NOR logic gate using chaotic semiconductor lasers under phase modulator control 被引量:1
18
作者 颜森林 《Chinese Optics Letters》 SCIE EI CAS CSCD 2010年第12期1147-1149,共3页
The theoretical construction of the fundamental × NOR gate using two injection semiconductor laser diodes due to mutual coupling is presented. Two laser diodes that are commonly driven by a monochromatic light be... The theoretical construction of the fundamental × NOR gate using two injection semiconductor laser diodes due to mutual coupling is presented. Two laser diodes that are commonly driven by a monochromatic light beam result in chaos; however, chaotic synchronization between the two lasers may be achieved by coupling them. The all-optical logic gate is finally implemented by synchronizing or un-synchronizing appropriately the two chaotic states under a phase modulator (PM) control. Numerical results validate the feasibility of the method. 展开更多
关键词 Chaotic systems Lasers Light modulators Logic gates monochromatorS Numerical methods Phase modulation Semiconductor lasers Synchronization
原文传递
A new method to suppress high-order harmonics for a synchrotron radiation soft X-ray beamline
19
作者 郭志英 邢海英 +4 位作者 洪才浩 唐坤 韩勇 陈栋梁 赵屹东 《Chinese Physics C》 SCIE CAS CSCD 2015年第4期97-99,共3页
A feasible and convenient method is proposed to suppress higher-harmonics for a varied-line-spacing plane grating monochromator in the soft X-ray region. Related calculations and experiments demonstrate that decreasin... A feasible and convenient method is proposed to suppress higher-harmonics for a varied-line-spacing plane grating monochromator in the soft X-ray region. Related calculations and experiments demonstrate that decreasing the included angle slightly by changing the parameter of the exit arm length can significantly improve light purity. This method is suitable and has been used for experiments of detector calibration in beamline 4B7B at the Beijing Synchrotron Radiation Facility (BSRF). 展开更多
关键词 soft X-ray high-order harmonics detector calibration Monk-Gillieson monochromator SYNCHROTRONRADIATION
原文传递
Upgrade of beamline 3W1B at Beijing Synchrotron Radiation Facility
20
作者 杨栋亮 崔明启 +8 位作者 王秋平 赵屹东 郑雷 席识博 刘利娟 郭志英 王得来 李朝阳 安宁 《Chinese Physics C》 SCIE CAS CSCD 2013年第5期85-88,共4页
To improve the performance of Beamline 3WIB at the Beijing Synchrotron Radiation Facility for the soft X-ray magnetic linear dichroism research at transition metals L2,3 edges, a new monochromator was designed and bui... To improve the performance of Beamline 3WIB at the Beijing Synchrotron Radiation Facility for the soft X-ray magnetic linear dichroism research at transition metals L2,3 edges, a new monochromator was designed and built to replace the original one. After the assemblage, alignment and adjustment of the monochromator system, the first commissioning results were obtained. The photon energy range is from 50 to 1000 eV with spectral resolutions of 1600 at 250 eV and 1000 at 870 eV. The photon flux is of the order of 10s-109 photons/s/200 mA/0.1%BW. In the electron's orbital plane the linear polarization degree of the light is higher than 99% at 704 eV. The beamline has satisfied the basic experimental requirements. 展开更多
关键词 wiggler beamline monochromator varied-space plane grating spectral resolution linear polarization
原文传递
上一页 1 2 下一页 到第
使用帮助 返回顶部