Separate-effect experiment simulating steam direct-contact condensation on ECCS (emergency core cooling system) water in PWR (pressurized water reactor) cold legs during reflood phase of large-break LOCA (loss-of...Separate-effect experiment simulating steam direct-contact condensation on ECCS (emergency core cooling system) water in PWR (pressurized water reactor) cold legs during reflood phase of large-break LOCA (loss-of-coolant accident) was conducted in OECD/NEA ROSA Project using the LSTF (large scale test facility). A new test section was furnished in the downstream of the LSTF break unit horizontally attached to the cold leg. Significant condensation of steam appeared in a short distance from the simulated ECCS injection point, and the steam temperature in the test section decreased immediately after the initiation of the ECCS water injection. Total steam condensation rate estimated from the difference between steam flow rates at the test section inlet and outlet was in proportion to the simulated ECCS water mass flux until the complete condensation of steam. Clear images of high-speed video camera were successfully obtained on droplet behaviors through the viewer of the test section, especially for annular mist flow.展开更多
This work illustrates the innovative results obtained by applying the recently developed the 2<sup>nd</sup>-order predictive modeling methodology called “2<sup>nd</sup>- BERRU-PM”, where the ...This work illustrates the innovative results obtained by applying the recently developed the 2<sup>nd</sup>-order predictive modeling methodology called “2<sup>nd</sup>- BERRU-PM”, where the acronym BERRU denotes “best-estimate results with reduced uncertainties” and “PM” denotes “predictive modeling.” The physical system selected for this illustrative application is a polyethylene-reflected plutonium (acronym: PERP) OECD/NEA reactor physics benchmark. This benchmark is modeled using the neutron transport Boltzmann equation (involving 21,976 uncertain parameters), the solution of which is representative of “large-scale computations.” The results obtained in this work confirm the fact that the 2<sup>nd</sup>-BERRU-PM methodology predicts best-estimate results that fall in between the corresponding computed and measured values, while reducing the predicted standard deviations of the predicted results to values smaller than either the experimentally measured or the computed values of the respective standard deviations. The obtained results also indicate that 2<sup>nd</sup>-order response sensitivities must always be included to quantify the need for including (or not) the 3<sup>rd</sup>- and/or 4<sup>th</sup>-order sensitivities. When the parameters are known with high precision, the contributions of the higher-order sensitivities diminish with increasing order, so that the inclusion of the 1<sup>st</sup>- and 2<sup>nd</sup>-order sensitivities may suffice for obtaining accurate predicted best- estimate response values and best-estimate standard deviations. On the other hand, when the parameters’ standard deviations are sufficiently large to approach (or be outside of) the radius of convergence of the multivariate Taylor-series which represents the response in the phase-space of model parameters, the contributions stemming from the 3<sup>rd</sup>- and even 4<sup>th</sup>-order sensitivities are necessary to ensure consistency between the computed and measured response. In such cases, the use of only the 1<sup>st</sup>-order sensitivities erroneously indicates that the computed results are inconsistent with the respective measured response. Ongoing research aims at extending the 2<sup>nd</sup>-BERRU-PM methodology to fourth-order, thus enabling the computation of third-order response correlations (skewness) and fourth-order response correlations (kurtosis).展开更多
文摘Separate-effect experiment simulating steam direct-contact condensation on ECCS (emergency core cooling system) water in PWR (pressurized water reactor) cold legs during reflood phase of large-break LOCA (loss-of-coolant accident) was conducted in OECD/NEA ROSA Project using the LSTF (large scale test facility). A new test section was furnished in the downstream of the LSTF break unit horizontally attached to the cold leg. Significant condensation of steam appeared in a short distance from the simulated ECCS injection point, and the steam temperature in the test section decreased immediately after the initiation of the ECCS water injection. Total steam condensation rate estimated from the difference between steam flow rates at the test section inlet and outlet was in proportion to the simulated ECCS water mass flux until the complete condensation of steam. Clear images of high-speed video camera were successfully obtained on droplet behaviors through the viewer of the test section, especially for annular mist flow.
文摘This work illustrates the innovative results obtained by applying the recently developed the 2<sup>nd</sup>-order predictive modeling methodology called “2<sup>nd</sup>- BERRU-PM”, where the acronym BERRU denotes “best-estimate results with reduced uncertainties” and “PM” denotes “predictive modeling.” The physical system selected for this illustrative application is a polyethylene-reflected plutonium (acronym: PERP) OECD/NEA reactor physics benchmark. This benchmark is modeled using the neutron transport Boltzmann equation (involving 21,976 uncertain parameters), the solution of which is representative of “large-scale computations.” The results obtained in this work confirm the fact that the 2<sup>nd</sup>-BERRU-PM methodology predicts best-estimate results that fall in between the corresponding computed and measured values, while reducing the predicted standard deviations of the predicted results to values smaller than either the experimentally measured or the computed values of the respective standard deviations. The obtained results also indicate that 2<sup>nd</sup>-order response sensitivities must always be included to quantify the need for including (or not) the 3<sup>rd</sup>- and/or 4<sup>th</sup>-order sensitivities. When the parameters are known with high precision, the contributions of the higher-order sensitivities diminish with increasing order, so that the inclusion of the 1<sup>st</sup>- and 2<sup>nd</sup>-order sensitivities may suffice for obtaining accurate predicted best- estimate response values and best-estimate standard deviations. On the other hand, when the parameters’ standard deviations are sufficiently large to approach (or be outside of) the radius of convergence of the multivariate Taylor-series which represents the response in the phase-space of model parameters, the contributions stemming from the 3<sup>rd</sup>- and even 4<sup>th</sup>-order sensitivities are necessary to ensure consistency between the computed and measured response. In such cases, the use of only the 1<sup>st</sup>-order sensitivities erroneously indicates that the computed results are inconsistent with the respective measured response. Ongoing research aims at extending the 2<sup>nd</sup>-BERRU-PM methodology to fourth-order, thus enabling the computation of third-order response correlations (skewness) and fourth-order response correlations (kurtosis).