This paper studies a strongly convergent inertial forward-backward-forward algorithm for the variational inequality problem in Hilbert spaces.In our convergence analysis,we do not assume the on-line rule of the inerti...This paper studies a strongly convergent inertial forward-backward-forward algorithm for the variational inequality problem in Hilbert spaces.In our convergence analysis,we do not assume the on-line rule of the inertial parameters and the iterates,which have been assumed by several authors whenever a strongly convergent algorithm with an inertial extrapolation step is proposed for a variational inequality problem.Consequently,our proof arguments are different from what is obtainable in the relevant literature.Finally,we give numerical tests to confirm the theoretical analysis and show that our proposed algorithm is superior to related ones in the literature.展开更多
The work is dedicated to develop a one-step eco-friendly method to prepare antibacterial polyethylene terephthalate(PET).We report a one-step eco-friendly method to manufacture antibacterial PET via on-line amination ...The work is dedicated to develop a one-step eco-friendly method to prepare antibacterial polyethylene terephthalate(PET).We report a one-step eco-friendly method to manufacture antibacterial PET via on-line amination reaction by melt coextrusion.Beside evenly mixing of poly(hexamethylene guanidine)(PHMG)and PET in the melt coextrusion procedure,the amination reaction also occurred between PHMG and PET under high temperature(230-270℃).The antibacterial ability of composite PET showed obvious PHMG concentration dependence,and antibacterial activity reached more than 99%when PHMG content was 2.5 wt%.Moreover,LIVE/DEAD fluorescence test further confirmed that the composite PET could kill bacteria quickly and efiectively(within 30 min);while negligible cytotoxicity was observed to HSF and HUVEC cells.Onestep eco-friendly fabrication of composite antibacterial PET was accomplished by on-line melt coextrusion.The composite antibacterial PET has potential use in multiple fields to combat with pathogenic including textiles,packaging materials,decoration materials and biomedical devices,etc.展开更多
Based on the fact that on-line chat has become the most developing language form in the information age, this article point out the stylistic features of on-line English chat. Though in written language form, such lan...Based on the fact that on-line chat has become the most developing language form in the information age, this article point out the stylistic features of on-line English chat. Though in written language form, such language is spoken language in nature, thus it is worthwhile to analyze this special phaenomenon in lexical and grammatical level.展开更多
The control design, based on self-adaptive PID with genetic algorithms(GA) tuning on-line was investigated, for the temperature control of industrial microwave drying rotary device with the multi-layer(IMDRDWM) and wi...The control design, based on self-adaptive PID with genetic algorithms(GA) tuning on-line was investigated, for the temperature control of industrial microwave drying rotary device with the multi-layer(IMDRDWM) and with multivariable nonlinear interaction of microwave and materials. The conventional PID control strategy incorporated with optimization GA was put forward to maintain the optimum drying temperature in order to keep the moisture content below 1%, whose adaptation ability included the cost function of optimization GA according to the output change. Simulations on five different industrial process models and practical temperature process control system for selenium-enriched slag drying intensively by using IMDRDWM were carried out systematically, indicating the reliability and effectiveness of control design. The parameters of proposed control design are all on-line implemented without iterative predictive calculations, and the closed-loop system stability is guaranteed, which makes the developed scheme simpler in its synthesis and application, providing the practical guidelines for the control implementation and the parameter design.展开更多
In this study,we developed a novel on-line solid phase extraction(SPE)-ultra-high-performance liquid chromatography tandem mass spectrometry(UHPLC-MS/MS)-based analytical method for simultaneously quantifying 12 illic...In this study,we developed a novel on-line solid phase extraction(SPE)-ultra-high-performance liquid chromatography tandem mass spectrometry(UHPLC-MS/MS)-based analytical method for simultaneously quantifying 12 illicit drugs and metabolites(methamphetamine,amphetamine,morphine,codeine,6-monoacetylmorphine,benzoylecgonine,3,4-methylenedioxymethamphetamine,3,4-methylenedioxyamphetamine,cocaine,ketamine,norketamine,and methcathinone)and cotinine(COT)in wastewater samples.The analysis was performed by loading 2 m L of the sample onto an Oasis hydrophilic-lipophilic balance cartridge and using a cleanup step(5%methanol)to eliminate interference with a total run time of 13 min.The isotope-labeled internal standard method was used to quantify the target substances and correct for unavoidable losses and matrix effects during the on-line SPE process.Typical analytical characteristics used for method validation were sensitivity,linearity,precision,repeatability,recovery,and matrix effects.The limit of detection(LOD)and limit of quantification(LOQ)of each target were set at 0.20 ng/L and 0.50 ng/L,respectively.The linearity was between 0.5 ng/L and250 ng/L,except for that of COT.The intra-and inter-day precisions were<10.45%and 25.64%,respectively,and the relative recovery ranged from 83.74%to 162.26%.The method was used to analyze various wastewater samples from 33 cities in China,and the results were compared with the experimental results of identical samples analyzed using off-line SPE.The difference rate was between 19.91%and-20.44%,and the error range could be considered acceptable.These findings showed that on-line SPE is a suitable alternative to off-line SPE for the analysis of illicit drugs in samples.展开更多
The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples...The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples were extracted with 0.2%formic acid acetonitrile solution,purified by on-line SPE device with HLB column,then separated by XBridge C18 column,using 0.1%formic acid solution and acetonitrile as the mobile phase.Mass spectrometric data was acquired under multiple reaction monitoring(MRM)mode using positive ionization electrospray.Internal standard method was used in the quantification,good linear relationship was got in range of 0.1–100 ng/mL and correlation coefficient was higher than 0.9990.The limits of detection were in the range of 0.125–2.00g/kg and the limits of quantitation were in the range of 0.250–5.00g/kg.Recoveries of the method were in range of 78.3%–99.3%,relative standard deviation were lower than 10%.The method was simple,sensitivity,and could be used for routine supervision and analysis of fifteen sulfonamides in pork and fish.展开更多
文摘This paper studies a strongly convergent inertial forward-backward-forward algorithm for the variational inequality problem in Hilbert spaces.In our convergence analysis,we do not assume the on-line rule of the inertial parameters and the iterates,which have been assumed by several authors whenever a strongly convergent algorithm with an inertial extrapolation step is proposed for a variational inequality problem.Consequently,our proof arguments are different from what is obtainable in the relevant literature.Finally,we give numerical tests to confirm the theoretical analysis and show that our proposed algorithm is superior to related ones in the literature.
基金Funded by the National Natural Science Foundation of China(No.51703169)Key Program of Science and Technology of Jieyang City(No.2019016)Key Research and Development Program of Shandong Province of China(No.2019JZZY010338)。
文摘The work is dedicated to develop a one-step eco-friendly method to prepare antibacterial polyethylene terephthalate(PET).We report a one-step eco-friendly method to manufacture antibacterial PET via on-line amination reaction by melt coextrusion.Beside evenly mixing of poly(hexamethylene guanidine)(PHMG)and PET in the melt coextrusion procedure,the amination reaction also occurred between PHMG and PET under high temperature(230-270℃).The antibacterial ability of composite PET showed obvious PHMG concentration dependence,and antibacterial activity reached more than 99%when PHMG content was 2.5 wt%.Moreover,LIVE/DEAD fluorescence test further confirmed that the composite PET could kill bacteria quickly and efiectively(within 30 min);while negligible cytotoxicity was observed to HSF and HUVEC cells.Onestep eco-friendly fabrication of composite antibacterial PET was accomplished by on-line melt coextrusion.The composite antibacterial PET has potential use in multiple fields to combat with pathogenic including textiles,packaging materials,decoration materials and biomedical devices,etc.
文摘Based on the fact that on-line chat has become the most developing language form in the information age, this article point out the stylistic features of on-line English chat. Though in written language form, such language is spoken language in nature, thus it is worthwhile to analyze this special phaenomenon in lexical and grammatical level.
基金Project(51090385) supported by the Major Program of National Natural Science Foundation of ChinaProject(2011IB001) supported by Yunnan Provincial Science and Technology Program,China+1 种基金Project(2012DFA70570) supported by the International Science & Technology Cooperation Program of ChinaProject(2011IA004) supported by the Yunnan Provincial International Cooperative Program,China
文摘The control design, based on self-adaptive PID with genetic algorithms(GA) tuning on-line was investigated, for the temperature control of industrial microwave drying rotary device with the multi-layer(IMDRDWM) and with multivariable nonlinear interaction of microwave and materials. The conventional PID control strategy incorporated with optimization GA was put forward to maintain the optimum drying temperature in order to keep the moisture content below 1%, whose adaptation ability included the cost function of optimization GA according to the output change. Simulations on five different industrial process models and practical temperature process control system for selenium-enriched slag drying intensively by using IMDRDWM were carried out systematically, indicating the reliability and effectiveness of control design. The parameters of proposed control design are all on-line implemented without iterative predictive calculations, and the closed-loop system stability is guaranteed, which makes the developed scheme simpler in its synthesis and application, providing the practical guidelines for the control implementation and the parameter design.
基金supported by the National Key Research and Development Program of China(Grant No.:2018YFC0807402)the National Natural Science Foundation of China(Grant No.:82073810)。
文摘In this study,we developed a novel on-line solid phase extraction(SPE)-ultra-high-performance liquid chromatography tandem mass spectrometry(UHPLC-MS/MS)-based analytical method for simultaneously quantifying 12 illicit drugs and metabolites(methamphetamine,amphetamine,morphine,codeine,6-monoacetylmorphine,benzoylecgonine,3,4-methylenedioxymethamphetamine,3,4-methylenedioxyamphetamine,cocaine,ketamine,norketamine,and methcathinone)and cotinine(COT)in wastewater samples.The analysis was performed by loading 2 m L of the sample onto an Oasis hydrophilic-lipophilic balance cartridge and using a cleanup step(5%methanol)to eliminate interference with a total run time of 13 min.The isotope-labeled internal standard method was used to quantify the target substances and correct for unavoidable losses and matrix effects during the on-line SPE process.Typical analytical characteristics used for method validation were sensitivity,linearity,precision,repeatability,recovery,and matrix effects.The limit of detection(LOD)and limit of quantification(LOQ)of each target were set at 0.20 ng/L and 0.50 ng/L,respectively.The linearity was between 0.5 ng/L and250 ng/L,except for that of COT.The intra-and inter-day precisions were<10.45%and 25.64%,respectively,and the relative recovery ranged from 83.74%to 162.26%.The method was used to analyze various wastewater samples from 33 cities in China,and the results were compared with the experimental results of identical samples analyzed using off-line SPE.The difference rate was between 19.91%and-20.44%,and the error range could be considered acceptable.These findings showed that on-line SPE is a suitable alternative to off-line SPE for the analysis of illicit drugs in samples.
基金This work was supported by“National Key Research and Development Program of China”(Project No.2018YFC1603400)Science and Technology Program of Hebei Province(Project No.19225503D).
文摘The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples were extracted with 0.2%formic acid acetonitrile solution,purified by on-line SPE device with HLB column,then separated by XBridge C18 column,using 0.1%formic acid solution and acetonitrile as the mobile phase.Mass spectrometric data was acquired under multiple reaction monitoring(MRM)mode using positive ionization electrospray.Internal standard method was used in the quantification,good linear relationship was got in range of 0.1–100 ng/mL and correlation coefficient was higher than 0.9990.The limits of detection were in the range of 0.125–2.00g/kg and the limits of quantitation were in the range of 0.250–5.00g/kg.Recoveries of the method were in range of 78.3%–99.3%,relative standard deviation were lower than 10%.The method was simple,sensitivity,and could be used for routine supervision and analysis of fifteen sulfonamides in pork and fish.