期刊文献+
共找到33篇文章
< 1 2 >
每页显示 20 50 100
Implementation of Level-3 Autonomous Patient-Specific Quality Assurance with Automated Human Interactive Devices
1
作者 Jingqiao Zhang Yizhou Zhao +2 位作者 Jameson T. Baker Yijian Cao Jenghwa Chang 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2023年第4期99-113,共15页
Purpose: Patient-specific quality assurance (PSQA) requires manual operation of different workstations, which is time-consuming and error-prone. Therefore, developing automated solutions to improve efficiency and accu... Purpose: Patient-specific quality assurance (PSQA) requires manual operation of different workstations, which is time-consuming and error-prone. Therefore, developing automated solutions to improve efficiency and accuracy is a priority. The purpose of this study was to develop a general software interface with scripting on a human interactive device (HID) for improving the efficiency and accuracy of manual quality assurance (QA) procedures. Methods: As an initial application, we aimed to automate our PSQA workflow that involves Varian Eclipse treatment planning system, Elekta MOSAIQ oncology information system and PTW Verisoft application. A general platform, the AutoFrame interface with two imbedded subsystems—the AutoFlow and the PyFlow, was developed with a scripting language for automating human operations of aforementioned systems. The interface included three functional modules: GUI module, UDF script interpreter and TCP/IP communication module. All workstations in the PSQA process were connected, and most manual operations were automated by AutoFrame sequentially or in parallel. Results: More than 20 PSQA tasks were performed both manually and using the developed AutoFrame interface. On average, 175 (±12) manual operations of the PSQA procedure were eliminated and performed by the automated process. The time to complete a PSQA task was 8.23 (±0.78) minutes for the automated workflow, in comparison to 13.91 (±3.01) minutes needed for manual operations. Conclusion: We have developed the AutoFrame interface framework that successfully automated our PSQA procedure, and significantly reduced the time, human (control/clicking/typing) errors, and operators’ stress. Future work will focus on improving the system’s flexibility and stability and extending its operations to other QA procedures. 展开更多
关键词 Level-3 Automation patient-specific Quality Assurance Human Interactive Devices SCRIPTING
下载PDF
Real-Time Patient-Specific ECG Arrhythmia Detection by Quantum Genetic Algorithm of Least Squares Twin SVM 被引量:2
2
作者 Duan Li Ruizheng Shi +2 位作者 Ni Yao Fubao Zhu Ke Wang 《Journal of Beijing Institute of Technology》 EI CAS 2020年第1期29-37,共9页
The automatic detection of cardiac arrhythmias through remote monitoring is still a challenging task since electrocardiograms(ECGs)are easily contaminated by physiological artifacts and external noises,and these morph... The automatic detection of cardiac arrhythmias through remote monitoring is still a challenging task since electrocardiograms(ECGs)are easily contaminated by physiological artifacts and external noises,and these morphological characteristics show significant variations for different patients.A fast patient-specific arrhythmia diagnosis classifier scheme is proposed,in which a wavelet adaptive threshold denoising is combined with quantum genetic algorithm(QAG)based on least squares twin support vector machine(LSTSVM).The wavelet adaptive threshold denoising is employed for noise reduction,and then morphological features combined with the timing interval features are extracted to evaluate the classifier.For each patient,an individual and fast classifier will be trained by common and patient-specific training data.Following the recommendations of the Association for the Advancements of Medical Instrumentation(AAMI),experimental results over the MIT-BIH arrhythmia benchmark database demonstrated that our proposed method achieved the average detection accuracy of 98.22%,99.65%and 99.41%for the abnormal,ventricular ectopic beats(VEBs)and supra-VEBs(SVEBs),respectively.Besides the detection accuracy,sensitivity and specificity,our proposed method consumes the less CPU running time compared with the other representative state of the art methods.It can be ported to Android based embedded system,henceforth suitable for a wearable device. 展开更多
关键词 WEARABLE ECG monitoring systems patient-specific ARRHYTHMIA classification quantum genetic algorithm least SQUARES TWIN SVM
下载PDF
Indirect printing of hierarchical patient-specific scaffolds for meniscus tissue engineering 被引量:2
3
作者 Joao BCosta Joana Silva-Correia +6 位作者 Sandra Pina Alain da Silva Morais Sílvia Vieira Hélder Pereira Joao Espregueira-Mendes Rui LReis Joaquim M.Oliveira 《Bio-Design and Manufacturing》 SCIE CSCD 2019年第4期225-241,共17页
The complex meniscus tissue plays a critical role in the knee. The high susceptibility to injury has led to an intense pursuit for better tissue engineering regenerative strategies, where scaffolds play a major role. ... The complex meniscus tissue plays a critical role in the knee. The high susceptibility to injury has led to an intense pursuit for better tissue engineering regenerative strategies, where scaffolds play a major role. In this study, indirect printed hierarchical multilayered sca ffolds composed by a silk fibroin (SF) upper layer and an 80/20 (w/w) ratio of SF/ionic-doped β-tricalcium phosphate (TCP) bottom layer were developed. Furthermore, a comparative analysis between two types of sca ffolds pro- duced using di fferent SF concentrations, i.e., 8% (w/v) (Hi8) and 16% (w/v) (Hi16) was performed. In terms of architecture and morphology, the produced sca ffolds presented homogeneous porosity in both layers and no di fferences were observed when comparing both sca ffolds. A decrease in terms of mechanical performance of the sca ffolds was observed when SF concentration decreased from 16 to 8% (w/v). Hi16 revealed a static compressive modulus of 0.66 ± 0.05 MPa and dynamical mechanical properties ranging from 2.17 ± 0.25 to 3.19 ± 0.38 MPa. By its turn, Hi8 presented a compressive modulus of 0.27 ± 0.08 MPa and dynamical mechanical properties ranging from 1.03 ± 0.08 MPa to 1.56 ± 0.13 MPa. In vitro bioactivity studies showed formation of apatite crystals onto the surface of Hi8 and Hi16 bottom layers. Human meniscus cells (hMCs) and human primary osteoblasts were cultured separately onto the top layer (SF8 and SF16) and bottom layer (SF8/TCP and SF16/TCP) of the hierarchical sca ffolds Hi8 and Hi16, respectively. Both cell types showed good adhesion and proliferation as denoted by the live/dead staining, Alamar Blue assay and DNA quanti fication analysis. Subcutaneous implantation in mice revealed weak in flammation and sca ffold’s integrity. The hierarchical indirect printed SF sca ffolds can be promising candidate for meniscus TE sca ffolding applications due their suitable mechanical properties, good biological performance and possibility of being applied in a patient-speci fic approach. 展开更多
关键词 patient-specific Indirect printing HIERARCHICAL SILK fibroin Enzymatic-cross-linking MENISCUS
下载PDF
Computerised tomography vs magnetic resonance imaging for modeling of patient-specific instrumentation in total knee arthroplasty 被引量:2
4
作者 Paul Stirling Rejith Valsalan Mannambeth +3 位作者 Agustin Soler Vineet Batta Rajeev Kumar Malhotra Yegappan Kalairajah 《World Journal of Orthopedics》 2015年第2期290-297,共8页
AIM: To summarise and compare currently available evidence regarding accuracy of pre-operative imaging, which is one of the key choices for surgeons contemplating patient-specific instrumentation(PSI) surgery.METHODS:... AIM: To summarise and compare currently available evidence regarding accuracy of pre-operative imaging, which is one of the key choices for surgeons contemplating patient-specific instrumentation(PSI) surgery.METHODS: The MEDLINE and EMBASE medical literature databases were searched, from January 1990 to December 2013, to identify relevant studies. The data from several clinical studies was assimilated to allow appreciation and comparison of the accuracy of each modality. The overall accuracy of each modality was calculated as proportion of outliers > 3% in the coronal plane of both computerised tomography(CT) or magnetic resonance imaging(MRI). RESULTS: Seven clinical studies matched our inclusion criteria for comparison and were included in our study for statistical analysis. Three of these reported series using MRI and four with CT. Overall percentage of outliers > 3% in patients with CT-based PSI systems was 12.5% vs 16.9% for MRI-based systems. These results were not statistically significant. CONCLUSION: Although many studies have been undertaken to determine the ideal pre-operative imaging modality, conclusions remain speculative in the absence of long term data. Ultimately, information regarding accuracy of CT and MRI will be the main determining factor. Increased accuracy of pre-operative imaging could result in longer-term savings, and reduced accumulated dose of radiation by eliminating the need for post-operative imaging and revision surgery. 展开更多
关键词 patient-specific INSTRUMENTATION ARTHROPLASTY ALIGNMENT Accuracy COST-EFFECTIVENESS
下载PDF
Influence of Clip Locations on Intraaneurysmal Flow Dynamics in Patient-specific Anterior Communicating Aneurysm Models with Different Aneurysmal Angle 被引量:1
5
作者 Lizhong Mu Qingzhuo Chi +2 位作者 Changjin Ji Ying He Ge Gao 《Computer Modeling in Engineering & Sciences》 SCIE EI 2018年第8期175-197,共23页
To improve aneurysm treatment,this study examined the influence of clip locations on hemodynamic factors in patient-specific anterior communicating artery(ACoA)aneurysms with different aneurysmal angle.We proposed a s... To improve aneurysm treatment,this study examined the influence of clip locations on hemodynamic factors in patient-specific anterior communicating artery(ACoA)aneurysms with different aneurysmal angle.We proposed a simplified classification of ACoA aneurysms using aneurysmal angle,defined by the angle of pivot of the aneurysmal dome and the virtual two-dimensional plane created by both proximal A2 segments of anterior cerebral artery(ACA).ACoA aneurysms with three different aneurysmal angles,which are 15°,80°and 120°,were analyzed in our study.In this work,we obtained hemodynamics before and after clipping surgery with three clip locations based on clinical clipping strategies in three ACoA aneurysms with different aneurysm angles.Results showed that local high pressure occurs at impingement region of the ACoA aneurysm before clipping and new impingement region close to the clipping location after clipping treatment.For clipping the aneurysm with aneurysmal angle 15°and a wide neck,wall shear stress(WSS)distribution is more uniform when the clipping angle of two clips close to 180°comparing with other two angles.In addition,for clipping the aneurysm with aneurysmal angle 80°and 120°,local high pressure appears on new impingement region and high WSS distributes around the clipping location when the clip plane is normal to the direction of inflow of aneurysm from the dominance of A1 segment of ACA.Hence,we should avoid the impingement of inflow from the A1 segment and choose a favorable clipping location for the fastness of clip.The results of our study could preoperatively give a useful information to the decision of surgical plan. 展开更多
关键词 Intracranial ANEURYSM ANTERIOR COMMUNICATING artery surgical CLIPPING treatment patient-specific model intraaneurysmal flow dynamics
下载PDF
A Systematic Approach for Making 3D-Printed Patient-Specific Implants for Craniomaxillofacial Reconstruction 被引量:1
6
作者 Ruxu Du Yu-Xiong Su +7 位作者 Yu Yan Wing Shan Choi Wei-Fa Yang Chunyu Zhang Xianshuai Chen Justin Paul Curtin Jianglin Ouyang Bitao Zhang 《Engineering》 SCIE EI 2020年第11期1291-1301,共11页
Craniomaxillofacial reconstruction implants,which are extensively used in head and neck surgery,are conventionally made in standardized forms.During surgery,the implant must be bended manually to match the anatomy of ... Craniomaxillofacial reconstruction implants,which are extensively used in head and neck surgery,are conventionally made in standardized forms.During surgery,the implant must be bended manually to match the anatomy of the individual bones.The bending process is time-consuming,especially for inexperienced surgeons.Moreover,repetitive bending may induce undesirable internal stress concentration,resulting in fatigue under masticatory loading in v iv o and causing various complications such as implant fracture,screw loosening,and bone resorption.There have been reports on the use of patient-specific 3D-printed implants for craniomaxillofacial reconstruction,although few reports have considered implant quality.In this paper,we present a systematic approach for making 3D-printed patientspecific surgical implants for craniomaxillofacial reconstruction.The approach consists of three parts:First,an easy-to-use design module is developed using Solidworks®software,which helps surgeons to design the implants and the axillary fixtures for surgery.Design engineers can then carry out the detailed design and use finite-element modeling(FEM)to optimize the design.Second,the fabrication process is carried out in three steps:0 testing the quality of the powder;(2)setting up the appropriate process parameters and running the 3D printing process;and (3)conducting post-processing treatments(i.e.,heat and surface treatments)to ensure the quality and performance of the implant.Third,the operation begins after the final checking of the implant and sterilization.After the surgery,postoperative rehabilitation follow-up can be carried out using our patient tracking software.Following this systematic approach,we have successfully conducted a total of 41 surgical cases.3D-printed patient-specific implants have a number of advantages;in particular,their use reduces surgery time and shortens patient recovery time.Moreover,the presented approach helps to ensure implant quality. 展开更多
关键词 patient-specific implant Craniomaxillofacial reconstruction 3D printing Surgery
下载PDF
Patient-Specific QA of Spot-Scanning Proton Beams Using Radiochromic Film 被引量:1
7
作者 Maria F. Chan Chin-Cheng Chen +4 位作者 Chengyu Shi Jingdong Li Xiaoli Tang Xiang Li Dennis Mah 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2017年第2期111-123,共13页
Radiochromic film for spot-scanning QA provides high spatial resolution and efficiency gains from one-shot irradiation for multiple depths. However, calibration can be a tedious procedure which may limit widespread us... Radiochromic film for spot-scanning QA provides high spatial resolution and efficiency gains from one-shot irradiation for multiple depths. However, calibration can be a tedious procedure which may limit widespread use. Moreover, since there may be an energy dependence, which manifests as a depth dependence, this may require additional measurements for each patient. We present a one-scan protocol to simplify the procedure. A calibration using an EBT3 film, exposed by a 6-level step-wedge plan on a Proteus&reg;PLUS proton system (IBA, Belgium), was performed at depths of 18, 20, 24 cm using Plastic Water&reg;(CIRS, Norfolk, VA). The calibration doses ranged from 65 - 250 cGy (RBE) (relative biological effectiveness) for proton energies of 170 - 200 MeV. A clinical prostate + nodes plan was used for validation. The planar doses at selected depths were measured with EBT3 films and analyzed using one-scan protocol (one-scan digitization of QA film and at least one film exposed to a known dose). The gamma passing rates, dose-difference maps, and profiles of 2D planar doses measured with EBT3 film and IBA MatriXX-PT, versus the RayStation TPS calculations were analyzed and compared. The EBT3 film measurement results matched well with the TPS calculation data with an average passing rate of ~95% for 2%/2 mm and slightly lower passing rates were obtained from an ion chamber array detector. We were able to demonstrate that the use of a proton step-wedge provided clinically acceptable results and minimized variations between film-scanner orientation, inter-scan, and scanning conditions. Furthermore, for relative dosimetry (calibration is not done at the time of experiment), it could be derived from no more than two films exposed to known doses (one could be zero) for rescaling the master calibration curve at each depth. The sensitivity of the calibration to depth variations has been explored. One-scan protocol results appear to be comparable to that of the ion chamber array detector. The use of a proton step-wedge for calibration of EBT3 film potentially increases efficiency in patient-specific QA of proton beams. 展开更多
关键词 PROTON THERAPY patient-specific QA Gaf Chromic EBT3 FILM DOSIMETRY
下载PDF
Patient-specific instrumentation in total ankle arthroplasty 被引量:1
8
作者 Antonio Mazzotti Alberto Arceri +3 位作者 Simone Zielli Simone Bonelli Valentina Viglione Cesare Faldini 《World Journal of Orthopedics》 2022年第3期230-237,共8页
The recent increase in the adoption of total ankle arthroplasty(TAA)reflects the improvements in implant designs and surgical techniques,including the use of preoperative navigation system and patient-specific instrum... The recent increase in the adoption of total ankle arthroplasty(TAA)reflects the improvements in implant designs and surgical techniques,including the use of preoperative navigation system and patient-specific instrumentation(PSI),such as custom-made cutting guides.Cutting guides are customized with respect to each patient's anatomy based on preoperative ankle computed tomography scans,and they drive the saw intra-operatively to improve the accuracy of bone resection and implant positioning.Despite some promising results,the main queries in the literature are whether PSI improves the reliability of achieving neutral ankle alignment and more accurate implant sizing,whether it is actually superior over standard techniques,and whether it is cost effective.Moreover,the advantages of PSI in clinical outcomes are still theoretical because the current literature does not allow to confirm its superiority.The purpose of this review article is therefore to assess the current literature on PSI in TAA with regard to current implants with PSI,templating and preoperative planning strategies,alignment and sizing,clinical outcomes,cost analysis,and comparison with standard techniques. 展开更多
关键词 Total ankle arthroplasty Total ankle replacement patient-specific instrumentation Ankle computer navigation system Preoperative navigation PROPHECY INFINITY INBONE II
下载PDF
MRI-Based Patient-Specific Left Ventricular Model to Determine the Effects of Trabeculae Carneae on the Diastolic and Systolic Functions
9
作者 Fatemeh Fatemifar Marc Feldman +2 位作者 Geoffrey Clarke Ender Finol Haichao Han 《医用生物力学》 EI CAS CSCD 北大核心 2019年第A01期19-20,共2页
Introduction Trabeculae carneae are irregular structures that cover the endocardial surfaces of both ventricles of human heart and account for a significant portion of the ventricular mass.However,the role of trabecul... Introduction Trabeculae carneae are irregular structures that cover the endocardial surfaces of both ventricles of human heart and account for a significant portion of the ventricular mass.However,the role of trabeculae carneae in left ventricular(LV)function is not well understood.Previous reports suggested that trabeculae help squeeze blood from the apical region during systole[1].Our recent study suggests that trabeculae carneae hypertrophy and fibrosis contribute to increased LV stiffness in patients with diastolic heart failure,and severing free-running trabeculae carneae may improve diastolic compliance of the LV[2].Objective To understand the role of trabeculae carneae in the left ventricular diastolic and systolic functions using anatomically detailed patient-specific finite element models of the human LV.Methods(1)Image acquisition An explanted human heart was collected from a 63 year old female donor with a history of stroke and congestive heart failure within 24 hours postmortem from South Texas Blood and Tissue Center(San Antonio,TX).The heart was de-identified in accordance with Institutional Review Board(IRB)requirements and informed consent for research was obtained from the donor’s family.Three-dimensional MRI scanning was conducted on a 3T(128 MHz)MRI system(TIM Trio,Siemens Medical Solutions),comprised of a superconducting magnet with a 60 cm diameter accessible bore,when the heart was submerged in a saline filled plastic container.(2)Finite element analysis Three distinct LV models were derived from the MR images.The first model was the intact trabeculated model(TM)which contained all trabeculae carneae and papillary muscles.This high-resolution anatomically detailed 3D model of the LV was segmented from 2D MR images in DICOM format using Mimics(Materialise NV,Leuven,Belgium).The second model was the papillary model(PM),in which the papillary muscles remain intact but most of the trabeculae carneae were excluded in the smoothing process.The third model was the smooth model(SM)in which the trabeculae carneae and papillary muscles were excluded during image segmentation.Finite element(FE)models of the TM,PM and SM were created by meshing 3D reconstructions of the acquired MR images using tetrahedral elements(ICEM,Ansys Inc.,Canonsburg,PA).The mesh size was selected after a pilot study on mesh sensitivity.The passive cardiac muscle was characterized as a hyperelastic,incompressible,transversely isotropic material with a Fung exponential strain energy function.The material constants were determined by matching the end-diastolic pressure-volume relationship with the empirical Klotz relation[3].A rule-based myocardial fiber algorithm was adopted to generate the myofiber directions [4].The active contraction(i.e.,systolic contraction)was modeled by the time varying'Elastance'active contraction model.The contractile parameter Tmax was determined and calibrated so that the FE predicted ejection fraction(EF)of TM matched the EF of a normal human heart at the specified end-systolic pressure[3].The analysis of the TM,PM,and SM models were implemented using the open-source finite element package FEBio(www.febio.org).In all models,the rigid body motion was suppressed by constraining the base from moving in all directions.The end-diastolic and end-systolic pressure-volume relationships(EDPVR and ESPVR)were obtained and characterized by an exponential function and the slope,respectively.Results Our simulation results showed that independent of the material model,the EDPVR curve shifts to the right in PM and SM compared to TM.However,the ESPVR curve may shift to the right or left in PM compared to TM,while shifting tothe right in SM for all material models.EDPVR was steeper in TM compared to PM and SM;however,ESPVR was found to be steeper in PM than in TM and SM.The predicted parameters of EDPVR and ESPVR showed lower average exponential term in PM and SM compared to TM,indicating a significant improvement in the compliance and global diastolic function of less trabeculated LV models(P<0.01).Similarly,the higher average elastance EEs and lower volume intersect in PM compared to TM,suggests that mild cutting of trabeculae carneae slightly improves the global systolic function of the LV(P=0.89).However,cutting all trabeculae carneae and papillary muscles in SM had a significant adverse effect on the global systolic function(P<0.01).Discussion and conclusions Most patient-specific LV studies in the literature have used smoothed ventricular geometries.We used high resolution MRI to capture the endocardial details of the LV.Though reproducing very fine trabeculae carneae was restricted by the MRI resolution,our results demonstrated the importance of considering endocardial structures,i.e.papillary muscles and trabeculae carneae,in the assessment of LV global function in patient-specific computational LV models.The present work is consistent with the observation that diastolic performance improved after severing trabeculae carneae due to a reduction in LV stiffness[2].Furthermore,our results also suggest that severing trabeculae carneae(without affecting papillary muscle)may improve LV systolic function.Our model results are consistent with experimental measurements using ex vivo rabbit heart perfusion [5].This improvement would be greater in hypertrophic hearts because trabeculae carneae are also hypertrophic and more fibrotic.Left ventricular hypertrophy is often associated with heart failure with preserved ejection fraction(HFpEF).There is no effective treatment for HFpEF,which is characterized by impaired diastolic relaxation due to increased LV stiffness.Our results indicate that trabecular cutting could be an effective treatment for HFpEF. 展开更多
关键词 EF MRI-Based patient-specific TRABECULAE Carneae the DIASTOLIC and Systolic F MODEL
原文传递
Study of Effect of Boundary Conditions on Patient-Specific Aortic Hemodynamics
10
作者 Qingzhuo Chi Huimin Chen +4 位作者 Shiqi Yang Lizhong Mu Changjin Ji Ying He Yong Luan 《Computer Modeling in Engineering & Sciences》 SCIE EI 2022年第4期31-47,共17页
Cardiovascular computational fluid dynamics(CFD)based on patient-specific modeling is increasingly used to predict changes in hemodynamic parameters before or after surgery/interventional treatment for aortic dissecti... Cardiovascular computational fluid dynamics(CFD)based on patient-specific modeling is increasingly used to predict changes in hemodynamic parameters before or after surgery/interventional treatment for aortic dissection(AD).This study investigated the effects of flow boundary conditions(BCs)on patient-specific aortic hemodynamics.We compared the changes in hemodynamic parameters in a type A dissection model and normal aortic model under different BCs:inflow from the auxiliary and truncated structures at aortic valve,pressure control and Windkessel model outflow conditions,and steady and unsteady inflow conditions.The auxiliary entrance remarkably enhanced the physiological authenticity of numerical simulations of flow in the ascending aortic cavity.Thus,the auxiliary entrance can well reproduce the injection flow fromthe aortic valve.In addition,simulations of the aortic model reconstructed with an auxiliary inflow structure and pressure control and the Windkessel model outflow conditions exhibited highly similar flow patterns and wall shear stress distribution in the ascending aorta under steady and unsteady inflow conditions.Therefore,the inflow structure at the valve plays a crucial role in the hemodynamics of the aorta.Under limited time and calculation cost,the steady-state study with an auxiliary inflow valve can reasonably reflect the blood flow state in the ascending aorta and aortic arch.With reasonable BC settings,cardiovascular CFD based on patient-specific ADmodels can aid physicians in noninvasive and rapid diagnosis. 展开更多
关键词 Aortic dissection boundary condition VALVE wall shear stress patient-specific model
下载PDF
Application of 3D printed patient-specific instrumentation in distal tibial tuberosity-high tibial osteotomy
11
作者 Ye-Tong Tan Xiang-Dong Tian +7 位作者 Jian Wang Guang-Yu Zhu Sheng Ma Yuan-Yi Hu Chang-Xiao Han Han-Dong Chen Ye Huang Tian-Song Ding 《Journal of Hainan Medical University》 2021年第21期22-27,共6页
Objective:To observe the clinical efficacy and advantages of 3D printed patient-specific instrumentation(PSI)assisted distal tibial tuberosity-high tibial osteotomy in the treatment of medial compartment knee osteoart... Objective:To observe the clinical efficacy and advantages of 3D printed patient-specific instrumentation(PSI)assisted distal tibial tuberosity-high tibial osteotomy in the treatment of medial compartment knee osteoarthritis.Methods:75 patients with medial compartment knee osteoarthritis were included in the study performed DTT-HTO in our hospital from August 2017 to August 2019.The patients were divided into the PSI group(n=39)and conventional group(n=36)According to whether PSI was used in surgery.The differences of lateral cortical fracture rate,time of intraoperative X-ray exposure,intraoperative blood loss,operative time,weight bearing line(WBL),Posterior tibial slope(PTS)and Caton-Deschamps index(CDI)were compared between the two groups.Visual analogue scale(VAS)scores and Hospital for Special Surgery(HSS)scores were recorded to evaluate knee pain and function before surgery and after surgery at 3 months and 12 months.Results:All 75 patients were followed up for more than 12 months,the ranged from 12-26(18.74±6.21)months.Three lateral cortical fractures in the conventional group and no fracture in PSI group.The lateral cortical fracture rate,time of intraoperative X-ray exposure,intraoperative blood loss,operative time in PSI group were lower than those in conventional group(p敿0.05).WBL in two groups were significantly improved after surgery(p敿0.05),and PTS,CDI were no statistically improved after surgery(p>0.05).While there was no statistically significant difference with WBL,PTS and CDI between two groups(p>0.05).At 1 months,3 months and 12 months after surgery;VAS and HSS scores in both groups were significantly improved compared with that before surgery(p0.05),and were no statistically significant difference between two groups.Conclusion:3D printed patient-specific instrumentation assisted DTT-HTO has significant clinical efficacy,and effectively standardized surgical procedures,meanwhile reduced the time of intraoperative X-ray exposure,intraoperative blood loss and risk of lateral cortical fracture. 展开更多
关键词 High tibial osteotomy Three-dimensional printing patient-specific instrumentation Medial compartment knee osteoarthritis
下载PDF
<i>In vitro</i>measurement of tibiofemoral kinematics after patient-specific unicompartmental knee replacement
12
作者 Dawie van den Heever Cornie Scheffer +1 位作者 Pieter Erasmus Edwin Dillon 《Journal of Biomedical Science and Engineering》 2012年第12期729-736,共8页
It is suggested that unicompartmental knee replacement (UKR) offers the potential to restore normal knee kinematics better than total knee replacement (TKR) because of retaining the cruciate ligaments, and better pres... It is suggested that unicompartmental knee replacement (UKR) offers the potential to restore normal knee kinematics better than total knee replacement (TKR) because of retaining the cruciate ligaments, and better preservation of the overall geometry. It was hypothesized that patient-specific UKR would restore normal knee kinematics even better because of a customised articular shape. A comparative kinematics study was conducted on three cadaver limbs using two different test setups, a loaded ankle rig and an unloaded ankle rig. Kinematics was compared between a patient-specific UKR and a conventional fixed-bearing UKR. Both the UKRs showed similar kinematic patterns to the normal knee using both the test apparatus. The patient-specific UKR showed good results and with the other benefits it shows potential to dramatically improve clinical outcomes of knee replacement surgery. 展开更多
关键词 TIBIOFEMORAL KINEMATICS patient-specific KNEE UNICOMPARTMENTAL KNEE Replacement
下载PDF
Evaluation of Patient-Specific Quality Assurance for Carbon Ion Radiotherapy Using Full Energy Scanning Method at QST Hospital
13
作者 Asami Inomata Masashi Katsumata +7 位作者 Sung Hyun Lee Yui Suzuki Takeo Nakajima Wataru Furuichi Keishi Yamaoka Atsushi Yamamoto Hideyuki Mizuno Ryosuke Kohno 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2022年第4期200-209,共10页
Purpose: Patient-specific QA (PSQA) measurements for carbon ion radiotherapy (CIRT) are critical components of processes designed to identify discrepancies between calculated and delivered doses. We report t... Purpose: Patient-specific QA (PSQA) measurements for carbon ion radiotherapy (CIRT) are critical components of processes designed to identify discrepancies between calculated and delivered doses. We report the results of PSQA conducted at the QST Hospital during the period from September 2017 to March 2018. Methods: We analyzed PSQA results for 1448 fields for 10 disease sites with various target volumes, target depths and number of energy layers. For the PSQA, all the planned beams were recalculated on a water phantom with treatment planning software. The recalculated dose distributions were compared with the measured distributions using a 2D ionization chamber array at three depths, including 95% of the area of the prescription dose. These recalculated dose distributions were evaluated using the 3%/3mm gamma index with a passing threshold of 90%. Results: The passing rates for prostate, head and neck, and bone and soft tissue were 96.8%, 99.3%, and 91.7%, respectively. Additionally, 94.7% of lung plans with low energy beams passed. Overall, the CIRT in the QST Hospital reached a high passing rate of more than 95%. Although the remaining 5% failed to pass, there was no dependence between measurement depth and disease sites in these failures. Conclusion: Using PSQA measurements, we confirmed consistency between the planned and delivered doses for CIRT using the full energy scanning method. 展开更多
关键词 Carbon Ion Radiotherapy Full Energy Scanning patient-specific Quality Assurance Gamma Index
下载PDF
Computer-Assisted Surgery for Mandibular Reconstruction Using a Patient-Specific Titanium Mesh Tray and Particulate Cancellous Bone and Marrow
14
作者 Seiji Kondo Hideyuki Katsuta +6 位作者 Ayako Akizuki Yuji Kurihara Takaaki Kamatani Atsushi Yaso Masahiro Nagasaki Toshikazu Shimane Tatsuo Shirota 《Case Reports in Clinical Medicine》 2015年第3期85-92,共8页
Craniomaxillofacial surgery is difficult due to the complexity of the regional anatomy. Computer-assisted surgery is a promising tool aiming to improve the safety and precision of such surgery. A computer-assisted sur... Craniomaxillofacial surgery is difficult due to the complexity of the regional anatomy. Computer-assisted surgery is a promising tool aiming to improve the safety and precision of such surgery. A computer-assisted surgical navigation approach for reconstruction of mandibular defects using a patient-specific titanium mesh tray and particulate cancellous bone and marrow (PCBM) harvested from bilateral anterior ilia is proposed. This case report involves a large multicystic ameloblastoma affecting the right mandible of a 31-year-old male patient. Following detailed clinical examination, radiological interpretation, and histopathological diagnosis, computer-assisted surgical simulation with a virtual 3-dimensional (3-D) model was designed using surgical planning software based on the pre-operative computed tomography data. Long-span segmental resection of the mandible was planned, and the defect was analyzed for reconstruction using a patient-specific reconstruction titanium mesh tray mediated with computer-aided design and manufacturing (CAD/CAM) techniques. During the actual surgery, the ultrasonic bone cutting instrument in the surgeon’s hand was connected to the navigation system to touch an anatomical position on the patient. Therefore, osteotomies were performed finely and smoothly according to the navigation images of the cutting bone line by sequentially moving the instrument. Finally, a CAD/CAM-mediated titanium mesh tray condensed by PCBM was adapted to the remaining mandibular fragments. Six months postoperatively, the patient had a good mandibular configuration and facial contour. Integration of different technologies, such as software planning and 3-D surgical simulation, combined with intraoperative navigation and CAD/CAM techniques, provides safe and precise mandibular reconstruction surgery. 展开更多
关键词 patient-specific Titanium Mesh TRAY Computer-Assisted Surgery MANDIBULAR Reconstruction PARTICULATE CANCELLOUS Bone and MARROW Surgical Navigation
下载PDF
Postoperative Mechanical Axis Alignment and Components Position after Conventional and Patient-Specific Total Knee Arthroplasty
15
作者 Mohamed Mosa Mohamed Maher A. El Assal +2 位作者 Ahmed M. Abdel Aal Yaser E. Khalifa Mahmoud A. Hafez 《Open Journal of Orthopedics》 2016年第8期253-258,共6页
Introduction: Accurate postoperative alignment and implant positioning are determinant factors for successful total knee arthroplasty (TKA). Patient-specific template (PST) is a technique that uses computer technology... Introduction: Accurate postoperative alignment and implant positioning are determinant factors for successful total knee arthroplasty (TKA). Patient-specific template (PST) is a technique that uses computer technology for the planning, deigning and production of cutting guides. This study aims to compare PST to conventional technique in terms of mechanical axis alignment and component positioning. Patients and method: 109 TKA were performed for 78 patients in 2 groups. Group A included 69 conventional TKA in 55 patients and Group B included 40 patient-specific TKA in 23 patient. Postoperative long-film X-rays were done for all patients to observe the mechanical axis, anatomical axis, lateral distal femoral mechanical angle and medial proximal tibial angle. Results: No statistically significant difference was found between the two groups regarding alignment or component positioning. Conclusion: Both techniques have shown similar results in restoring the mechanical axis and alignment after TKA. However, PST had the advantages of reduced blood loss and shorter operative time. 展开更多
关键词 Total Knee Arthroplasty patient-specific Templates Conventional TKA Mechanical Axis Limb Alignment Component Position
下载PDF
Image Registration Technique for Assessing the Accuracy of Intraoperative Osteotomy for Pelvic Tumors by 3D-Printed Patient-Specific Templates
16
作者 曲扬 严孟宁 +5 位作者 李小敏 吴兵 柳思宇 王燎 武文 艾松涛 《Journal of Shanghai Jiaotong university(Science)》 EI 2021年第3期306-311,共6页
The study aimed to explore the feasibility of an image registration technique for assessing the accuracy of intraoperative osteotomy of pelvic tumors by 3-dimensional(3D)-printed patient-specific templates.Patients wi... The study aimed to explore the feasibility of an image registration technique for assessing the accuracy of intraoperative osteotomy of pelvic tumors by 3-dimensional(3D)-printed patient-specific templates.Patients with malignant pelvic tumors who were admitted to our hospital between March 2014 and December 2020 were retrospectively enrolled.Patients underwent hemi-pelvic resection and reconstruction by 3D-printed individualized prostheses.The registration between the designed model and the postoperative segmented model of the prosthesis was used to obtain the intraoperative osteotomy plane and reduce metal artifacts in postoperative computed tomography(CT)images.The distance and angle between the planned and actual osteotomy planes were then used to assess the accuracy of the intraoperative osteotomy.Eight patients with 13 osteotomy planes were enrolled,including four males and four females.The median age at the time of imaging examination was 44 years(range,33–54 years).All intraoperative osteotomy planes were assessed successfully.The mean distance between the planned and true intraoperative osteotomy planes was−0.69 cm(−7.5–7.35 cm),and the mean angle was 6.57°±3.36°(1.05°–11.88°).This new assessment method of registering the designed model and the postoperative CT segmented model of the prosthesis may be used to assess the accuracy of intraoperative osteotomy for pelvic tumors,using 3D printed patient-specific templates. 展开更多
关键词 pelvic tumor image registration 3D-printed patient-specific template intraoperative osteotomy
原文传递
Using a Patient-Specific 3D-Printed Surgical Guide for High Tibial Osteotomy:A Technical Note
17
作者 江旭 谢凯 +5 位作者 李波 胡旭民 吴海山 高梁斌 王燎 严孟宁 《Journal of Shanghai Jiaotong university(Science)》 EI 2021年第3期339-345,共7页
Patient-specific instrumentation(PSI)enables a more accurate alignment of the lower limbs in a high tibial osteotomy(HTO)than in traditional surgery;however,the current design of commercial PSIs is not perfect.Therefo... Patient-specific instrumentation(PSI)enables a more accurate alignment of the lower limbs in a high tibial osteotomy(HTO)than in traditional surgery;however,the current design of commercial PSIs is not perfect.Therefore,we designed a new patient-specific surgical guide to improve the accuracy of the osteotomy and verified its reliability through a clinical operation.Here,we describe a patient with isolated medial-compartment bilateral knee osteoarthritis,accompanied by a varus deformity of the proximal tibia.The patient was treated with HTO using a patient-specific 3D-printed surgical guide.We concluded that the patient-specific 3D-printed surgical guide improved the accuracy of the osteotomy and the alignment of the lower limb. 展开更多
关键词 high tibial osteotomy(HTO) 3D printing patient-specific instrumentation(PSI) wedge augment
原文传递
Customized scaffolds for large bone defects using 3D‑printed modular blocks from 2D‑medical images
18
作者 Anil AAcar Evangelos Daskalakis +4 位作者 Paulo Bartolo Andrew Weightman Glen Cooper Gordon Blunn Bahattin Koc 《Bio-Design and Manufacturing》 SCIE EI CAS CSCD 2024年第1期74-87,共14页
Additive manufacturing(AM)has revolutionized the design and manufacturing of patient-specific,three-dimensional(3D),complex porous structures known as scaffolds for tissue engineering applications.The use of advanced ... Additive manufacturing(AM)has revolutionized the design and manufacturing of patient-specific,three-dimensional(3D),complex porous structures known as scaffolds for tissue engineering applications.The use of advanced image acquisition techniques,image processing,and computer-aided design methods has enabled the precise design and additive manufacturing of anatomically correct and patient-specific implants and scaffolds.However,these sophisticated techniques can be timeconsuming,labor-intensive,and expensive.Moreover,the necessary imaging and manufacturing equipment may not be readily available when urgent treatment is needed for trauma patients.In this study,a novel design and AM methods are proposed for the development of modular and customizable scaffold blocks that can be adapted to fit the bone defect area of a patient.These modular scaffold blocks can be combined to quickly form any patient-specific scaffold directly from two-dimensional(2D)medical images when the surgeon lacks access to a 3D printer or cannot wait for lengthy 3D imaging,modeling,and 3D printing during surgery.The proposed method begins with developing a bone surface-modeling algorithm that reconstructs a model of the patient’s bone from 2D medical image measurements without the need for expensive 3D medical imaging or segmentation.This algorithm can generate both patient-specific and average bone models.Additionally,a biomimetic continuous path planning method is developed for the additive manufacturing of scaffolds,allowing porous scaffold blocks with the desired biomechanical properties to be manufactured directly from 2D data or images.The algorithms are implemented,and the designed scaffold blocks are 3D printed using an extrusion-based AM process.Guidelines and instructions are also provided to assist surgeons in assembling scaffold blocks for the self-repair of patient-specific large bone defects. 展开更多
关键词 Additive manufacturing Modular scaffolds Large bone defect Customized scaffold design patient-specific scaffolds
下载PDF
Can preoperative planning using IRIS™three-dimensional anatomical virtual models predict operative findings during robot-assisted partial nephrectomy?
19
作者 Ahmed Ghazi Nitin Sharma +6 位作者 Ahmed Radwan Hani Rashid Thomas Osinski Thomas Frye William Tabayoyong Jonathan Bloom Jean Joseph 《Asian Journal of Urology》 CSCD 2023年第4期431-439,共9页
Objective To evaluate the predictive validity of IRIS™(Intuitive Surgical®,Sunnyvale,CA,USA)as a planning tool for robot-assisted partial nephrectomy(RAPN)by assessing the degree of overlap with intraoperative ex... Objective To evaluate the predictive validity of IRIS™(Intuitive Surgical®,Sunnyvale,CA,USA)as a planning tool for robot-assisted partial nephrectomy(RAPN)by assessing the degree of overlap with intraoperative execution.Methods Thirty-one patients scheduled for RAPN by four experienced urologists were enrolled in a prospective study.Prior to surgery,urologists reviewed the IRIS™three-dimensional model on an iphone Operating System(iOS)app and completed a questionnaire outlining their surgical plan including surgical approach,and ischemia technique as well as confidence in executing this plan.Postoperatively,questionnaires assessing the procedural approach,clinical utility,efficiency,and effectiveness of IRIS™were completed.The degree of overlap between the preoperative and intraoperative questionnaires and between the planned approach and actual execution of the procedure was analyzed.Questionnaires were answered on a 5-point Likert scale and scores of 4 or greater were considered positive.Results Mean age was 65.1 years with a mean tumor size of 27.7 mm(interquartile range 17.5-44.0 mm).Hilar tumors consisted of 32.3%;48.4%of patients had R.E.N.A.L.nephrometry scores of 7-9.On preoperative questionnaires,the surgeons reported that in 67.7%cases they were confident that they can perform the procedure successfully,and on intraoperative questionnaires,the surgeons reported that in 96.8%cases IRIS™helped achieve good spatial sensation of the anatomy.There was a high degree of overlap between preoperative and intraoperative questionnaires for the surgical approach,interpreting anatomical details and clinical utility.When comparing plans for selective or off-clamp,the preoperative plan was executed in 90.0%of cases intraoperatively.Conclusion A high degree of overlap between the preoperative surgical approach and intraoperative RAPN execution was found using IRIS™.This is the first study to evaluate the predictive accuracy of IRIS™during RAPN by comparing preoperative plan and intraoperative execution. 展开更多
关键词 Renal cancer patient-specific Three-dimensional virtual model Imaging Partial nephrectomy Robotics
下载PDF
Thinking outside the liver: Induced pluripotent stem cells for hepatic applications 被引量:4
20
作者 Mekala Subba Rao Mitnala Sasikala D Nageshwar Reddy 《World Journal of Gastroenterology》 SCIE CAS 2013年第22期3385-3396,共12页
The discovery of induced pluripotent stem cells (iPSCs) unraveled a mystery in stem cell research, after identification of four re-programming factors for generating pluripotent stem cells without the need of embryos.... The discovery of induced pluripotent stem cells (iPSCs) unraveled a mystery in stem cell research, after identification of four re-programming factors for generating pluripotent stem cells without the need of embryos. This breakthrough in generating iPSCs from somatic cells has overcome the ethical issues and immune rejection involved in the use of human embryonic stem cells. Hence, iPSCs form a great potential source for developing disease models, drug toxicity screening and cell-based therapies. These cells have the potential to differentiate into desired cell types, including hepatocytes, under in vitro as well as under in vivo conditions given the proper microenvironment. iPSC-derived hepatocytes could be useful as an unlimited source, which can be utilized in disease modeling, drug toxicity testing and producing autologous cell therapies that would avoid immune rejection and enable correction of gene defects prior to cell transplantation. In this review, we discuss the induction methods, role of reprogramming factors, and characterization of iPSCs, along with hepatocyte differentiation from iPSCs and potential applications. Further, we discuss the location and detection of liver stem cells and their role in liver regeneration. Although tumor formation and genetic mutations are a cause of concern, iPSCs still form a promising source for clinical applications. 展开更多
关键词 LIVER STEM cells HEPATOCYTES Disease modeling Drug toxicity Clinical APPLICATIONS patient-specific induced PLURIPOTENT STEM cell-derived HEPATOCYTES
下载PDF
上一页 1 2 下一页 到第
使用帮助 返回顶部