期刊文献+
共找到15,888篇文章
< 1 2 250 >
每页显示 20 50 100
Detection of internal crack growth in polyethylene pipe using guided wave ultrasonic testing
1
作者 Jay Kumar Shah Hao Wang Said El-Hawwat 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2024年第2期319-329,共11页
Despite the success of guided wave ultrasonic inspection for internal defect detection in steel pipes,its application on polyethylene(PE)pipe remains relatively unexplored.The growth of internal cracks in PE pipe seve... Despite the success of guided wave ultrasonic inspection for internal defect detection in steel pipes,its application on polyethylene(PE)pipe remains relatively unexplored.The growth of internal cracks in PE pipe severely affects its pressure-holding capacity,hence the early detection of internal cracks is crucial for effective pipeline maintenance strategies.This study extends the scope of guided wave-based ultrasonic testing to detect the growth of internal cracks in a natural gas distribution PE pipe.Laboratory experiments and a finite element model were planned to study the wave-crack interaction at different stages of axially oriented internal crack growth with a piezoceramic transducer-based setup arranged in a pitch-catch configuration.Mode dispersion analysis supplemented with preliminary experiments was performed to isolate the optimal inspection frequency,leading to the selection of the T(0,1)mode at 50-kHz for the investigation.A transmission index based on the energy of the T(0,1)mode was developed to trace the extent of simulated crack growth.The findings revealed an inverse linear correlation between the transmission index and the crack depth for crack growth beyond 20%crack depth. 展开更多
关键词 polyethylene pipes internal cracks guided wave ultrasonic testing torsional modes finite element modeling
下载PDF
Experimental Study of the Influence of Intrinsic Parameters on the Thermal Reactivity of Sawdust, Polyethylene Terephthalate and Composite
2
作者 Ange Brel Boukongou Timoléon Andzi Barhé 《Journal of Materials Science and Chemical Engineering》 2024年第3期9-20,共12页
Several works have been based on the study of thermal variations in biomass to derive more valuable products such as fuels capable of replacing oil in the event of a crisis or activated carbon used as an adsorbent mat... Several works have been based on the study of thermal variations in biomass to derive more valuable products such as fuels capable of replacing oil in the event of a crisis or activated carbon used as an adsorbent material, widely used in industry for the elimination of unwanted materials, both in liquid and gaseous environments. A study of thermal parameters such as: heating speed, retention time, drying temperature, carbonization temperature, particle size, was carried out with the aim of determining the characteristic factors of the carbonization of Polyethylene terephthalate (PET), sawdust (SC) and sawdust/polyethylene terephthalate (CPS) mixture. The results of the immediate analysis revealed a very low level of ash in PET (0.013%) compared to the level of ash in sawdust (2.9%), as well as a high level of fixed carbon (82.960%), which suggests the presence of mineral oxides and a significant carbon matrix unlike PET, which indicates a very significant organic matrix (essentially made up of organic matter) with the absence of mineral oxides. The study of thermal parameters showed the water loss from Sawdust (SC) and the Sawdust/Polyethylene terephthalate (CPS) mixture, an increase with temperature, unlike that of PET whose variation is essentially zero. Without heat treatment, sawdust alone contains approximately 7% water. The optimal drying temperature for this study is 110˚C for a stay of 24 hours. It appears that the largest mass losses for the PET samples are between 87.19% and 96.05%, followed by that of the mixture, between 47.33% and 64.37%. And the lowest are observed, those of sawdust (from 24.02% to 62.6%). However, here we can say that the influence of the mass is not great, given the slight difference between the losses by temperature. The results of the study of the influence of grain size showed that the differences are insignificant, even if we vary the diameter of the grains from simple to triple. To better minimize physical constraints such as the intragranular diffusibility of the volatile matter and the homogeneity of the temperature in the grains, 75 μm particles are found to be optimal for our study. It can be noted when studying the heating rate that the mass loss at the end of the reaction is approximately the same depending on each precursor material. However, it has been demonstrated that the heating rate strongly influences the nature of the reaction products both for volatile materials and for the solid residue as well as on the kinetic parameters of the chemical reaction. Furthermore, the variation in apparent density shows a decrease as a function of the increase in the residence time of the materials in the reactor. As the carbonization time increases, the apparent density decreases. We note, for the lignocellulosic material, that the apparent density stabilizes after 60 minutes. 展开更多
关键词 Intrinsic Parameters Thermal Reactivity SAWDUST polyethylene Terephthalate COMPOSITE
下载PDF
The Impact of the Inclusion of MgO Nano-Fillers in a Polyethylene Matrix on Dielectric Strength and Resistance to Partial Discharges
3
作者 Virginie Griseri Dominique Mary +1 位作者 David Malec Eric David 《Open Journal of Applied Sciences》 2024年第3期626-634,共9页
One commonly used strategy to enhance polymers specific properties such as the resistance to partial discharges erosion is the incorporation into the polymeric matrix of inorganic micro or nanoparticles. This study fo... One commonly used strategy to enhance polymers specific properties such as the resistance to partial discharges erosion is the incorporation into the polymeric matrix of inorganic micro or nanoparticles. This study focused on the dielectric properties of Low-Density Polyethylene (LDPE) filled with nano-sized Magnesium Oxide (MgO) particles compounded by thermo-mechanical process and one of the purposes was to establish appropriate processing parameters in order to reach the desired dielectric properties. LDPE was used as a matrix and was reinforced by MgO particles having a nominal average size of 30 nm. The MgO nanoparticles were treated with a silane coupling agent (3-Glycidyloxypropyl Trimethoxysilane). The samples were initially prepared in a melt-mixing chamber with a MgO content of 1% wt. These pre-mixed samples were further treated by the means of thermo-mechanical mixing in a conical co-rotating twin-screw extruder in order to improve the dispersion and distribution of the MgO particles. In this report, both lifetime under a PD activity and AC dielectric strength of pure and nano-filled LDPE samples have been measured and compared. Nano-filled LDPE samples were found to exhibit an improve lifetime, without any detrimental impact on their short-term dielectric strength. This suggests that nano-filled LDPE may be for electric applications for which the dielectric materials may be exposed to partial discharge activities. This is significant result for the use of MgO-reinforced PE as an insulating material for HV cables since the resistance to PD is closely related to treeing resistance which is the main electrical degradation mechanism that leads to failure for shielded extruded power cables. 展开更多
关键词 Low Density polyethylene MgO Nanofillers Dielectric Strength Partial Discharges Resistance
下载PDF
Emerging low-density polyethylene/paraffin wax/aluminum composite as a form-stable phase change thermal interface material 被引量:1
4
作者 Chuanchang Li Weixuan Wang +2 位作者 Xiaoliang Zeng Chunxuan Liu Rong Sun 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2023年第4期772-781,共10页
Thermal interface materials(TIMs) play a vital role in the thermal management of electronic devices and can significantly reduce thermal contact resistance(TCR). The TCR between the solid–liquid contact surface is mu... Thermal interface materials(TIMs) play a vital role in the thermal management of electronic devices and can significantly reduce thermal contact resistance(TCR). The TCR between the solid–liquid contact surface is much smaller than that of the solid–solid contact surface, but conventional solid–liquid phase change materials are likely to cause serious leakage. Therefore, this work has prepared a new formstable phase change thermal interface material. Through the melt blending of paraffin wax(PW) and low-density polyethylene(LDPE), the stability is improved and it has an excellent coating effect on PW. The addition of aluminum(Al) powder improves the low thermal conductivity of PW/LDPE, and the addition of 15wt% Al powder improves the thermal conductivity of the internal structure of the matrix by 67%. In addition, the influence of the addition of Al powder on the internal structure, thermal properties, and phase change behavior of the PW/LDPE matrix was systematically studied. The results confirmed that the addition of Al powder improved the thermal conductivity of the material without a significant impact on other properties, and the thermal conductivity increased with the increase of Al addition. Therefore, morphologically stable PW/LDPE/Al is an important development direction for TIMs. 展开更多
关键词 paraffin wax low-density polyethylene phase change materials thermal interface materials form stability
下载PDF
Hyponatremic encephalopathy due to polyethylene glycol-based bowel preparation for colonoscopy:A case report 被引量:1
5
作者 Yuan Zhao Hai-Sheng Dong 《World Journal of Clinical Cases》 SCIE 2023年第1期187-192,共6页
BACKGROUND Adequate bowel preparation is critical for colonoscopy screening.At present,the most widely used intestinal cleaner recommended at home and abroad is Polyethylene glycol(PEG).Intestinal cleansers can cause ... BACKGROUND Adequate bowel preparation is critical for colonoscopy screening.At present,the most widely used intestinal cleaner recommended at home and abroad is Polyethylene glycol(PEG).Intestinal cleansers can cause electrolyte disturbances and hyponatremia.However,hyponatremic encephalopathy due to hyponatremia induced by PEG solution,although rare,can lead to serious irreversible sequelae and even death.CASE SUMMARY In this report,we discuss a case of neurological dysfunction due to hyponatremia,also known as hyponatremic encephalopathy,observed in a 63-year-old woman who underwent PEG-based bowel preparation for colonoscopy.She was eventually transferred to our intensive care unit for treatment due to her Glasgow Coma Scale score of 9/15(Eye opening 2;Verbal response 1;Motor response 6)and abnormal laboratory tests.CONCLUSION Physicians should be thoroughly familiarized with the patient’s history before prescribing PEG for bowel preparation,and timely identification of patients with hyponatremic encephalopathy is essential as delayed treatment is associated with poor neurological outcomes.An intravenous infusion of 3%sodium chloride is recommended at the onset of early symptoms.The goal of treatment is to adequately treat cerebral edema while avoiding serum sodium correction beyond 15 to 20 m Eq/L within 48 h of treatment to prevent osmotic demyelination syndrome. 展开更多
关键词 polyethylene glycol Intestinal preparation Hyponatremic encephalopathy HYPONATREMIA BRAIN Case report
下载PDF
Polyethylene glycol crosslinked decellularized single liver lobe scaffolds with vascular endothelial growth factor promotes angiogenesis in vivo
6
作者 Jian-Se Zhang Zhi-Bin Wang +5 位作者 Zhi-Zhen Lai Jing-Wen Yang Wen-Jing Song Yu-Bing Wei Jin Mei Jian-Guang Wang 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS CSCD 2023年第6期622-631,共10页
Background: Improving the mechanical properties and angiogenesis of acellular scaffolds before transplantation is an important challenge facing the development of acellular liver grafts. The present study aimed to eva... Background: Improving the mechanical properties and angiogenesis of acellular scaffolds before transplantation is an important challenge facing the development of acellular liver grafts. The present study aimed to evaluate the cytotoxicity and angiogenesis of polyethylene glycol(PEG) crosslinked decellularized single liver lobe scaffolds(DLSs), and establish its suitability as a graft for long-term liver tissue engineering. Methods: Using mercaptoacrylate produced by the Michael addition reaction, DLSs were first modified using N-succinimidyl S-acetylthioacetate(SATA), followed by cross-linking with PEG as well as vascular endothelial growth factor(VEGF). The optimal concentration of agents and time of the individual steps were identified in this procedure through biomechanical testing and morphological analysis. Subsequently, human umbilical vein endothelial cells(HUVECs) were seeded on the PEG crosslinked scaffolds to detect the proliferation and viability of cells. The scaffolds were then transplanted into the subcutaneous tissue of Sprague-Dawley rats to evaluate angiogenesis. In addition, the average number of blood vessels was evaluated in the grafts with or without PEG at days 7, 14, and 21 after implantation. Results: The PEG crosslinked DLS maintained their three-dimensional structure and were more translucent after decellularization than native DLS, which presented a denser and more porous network structure. The results for Young’s modulus proved that the mechanical properties of 0.5 PEG crosslinked DLS were the best and close to that of native livers. The PEG-VEGF-DLS could better promote cell proliferation and differentiation of HUVECs compared with the groups without PEG cross-linking. Importantly, the average density of blood vessels was higher in the PEG-VEGF-DLS than that in other groups at days 7, 14, and 21 after implantation in vivo. Conclusions: The PEG crosslinked DLS with VEGF could improve the biomechanical properties of native DLS, and most importantly, their lack of cytotoxicity provides a new route to promote the proliferation of cells in vitro and angiogenesis in vivo in liver tissue engineering. 展开更多
关键词 DECELLULARIZATION Single liver lobe polyethylene glycol ANGIOGENESIS Liver tissue engineering
下载PDF
Natural aging mechanism of buried polyethylene pipelines during long-term service
7
作者 Ying-Chun Chen Yan-Feng Li +3 位作者 Yan Xi Qiang Li Qi Lu Jie Yang 《Petroleum Science》 SCIE EI CSCD 2023年第5期3143-3156,共14页
Currently,accelerated aging tests are widely used to study the aging process of polyethylene pipelines.However,this approach can only simulate one or several main influencing factors in the natural environment,which a... Currently,accelerated aging tests are widely used to study the aging process of polyethylene pipelines.However,this approach can only simulate one or several main influencing factors in the natural environment,which are often quite different from the actual environment of the buried pipelines.In this study,five types of PE80 buried pipelines in service for 9e18 years were taken as the research object,while new PE80 pipelines were taken as the reference group.The aging process and mechanism of polyethylene buried pipelines were studied through mechanical and chemical property tests and microstructural analysis.The results showed that the pipeline exhibited cross-linking as the main aging mechanism after being in service for 0e18 years.The aging degree and law of the inner and outer surface of the pipeline were compared,and the observed mechanism of both surfaces was explained.After 18 years in service,the elongation at the break of the pipe decreased by 16.2%,and the toughness of the matrix in the main collapse area of the tensile sample was the fundamental reason responsible for changes in the mechanical properties.Finally,after 18 years in service,the oxidation induction time of the pipeline was 25.7 min,which was 28.5% higher than the national standard value.There were no potential safety hazards during continuous long-term service.The results of this paper provide reference data and theoretical guidance for the aging process study of buried polyethylene pipelines. 展开更多
关键词 polyethylene Buried pipelines Long-term service Natural aging
下载PDF
Anaphylactic shock induced by polyethylene glycol after bowel preparation for the colorectal cancer surgery:A case report
8
作者 Go Woon Park Nahyeon Park +2 位作者 Jung Cheol Kuk Eung Jin Shin Dae Ro Lim 《World Journal of Clinical Cases》 SCIE 2023年第23期5589-5594,共6页
BACKGROUND Polyethylene glycol(PEG)is widely used as an additive because of its hydrophilic and chemically inert properties.However,there are been increasing reports of PEG allergies,including anaphylaxis,although the... BACKGROUND Polyethylene glycol(PEG)is widely used as an additive because of its hydrophilic and chemically inert properties.However,there are been increasing reports of PEG allergies,including anaphylaxis,although they are still rare.This case report aims to raise awareness,that the commonly used bowel cleansing agent containing PEG can cause serious allergic reactions.CASE SUMMARY Prior to surgery for sigmoid colon cancer,a 63-year-old man was prescribed a bowel cleansing agent containing PEG.Within 30 min of ingestion,he developed symptoms of anaphylactic shock and did not respond to initial intramuscular epinephrine injection.Under diagnosis of anaphylaxis to PEG,he was stabilized with fluid hydration and continuous norepinephrine infusion.CONCLUSION While allergic reactions to PEG are rare,they can be life-threatening.Therefore,it is crucial for clinicians to be aware of this possibility and to diagnose and resuscitate patients immediately. 展开更多
关键词 polyethylene glycol ANAPHYLAXIS Sigmoid colon cancer Bowel preparation Case report
下载PDF
Removal Effect of Coagulating Sedimentation Method on Polyethylene Microplastics in Water
9
作者 Shasha LIU Qiongru ZHUANG +3 位作者 Hongji HUANG Xiaodan LIN Yue YANG Jinghua WU 《Asian Agricultural Research》 2023年第9期31-33,43,共4页
Microplastic is a new kind of pollutant.It exists widely in the aquatic environment and seriously endangers the aquatic ecosystem.In this study,the coagulating sedimentation method was used to remove microplastics in ... Microplastic is a new kind of pollutant.It exists widely in the aquatic environment and seriously endangers the aquatic ecosystem.In this study,the coagulating sedimentation method was used to remove microplastics in water.Polyethylene(PE)was selected as the representative of microplastics,polyferric sulfate(PFS),polyaluminum chloride(PAC)and aluminum sulfate(AS)were used as coagulant,and polyacrylamide(PAM)was used as coagulant aid to study the effects of pH,coagulant concentration and sedimentation time on the removal of PE by single and composite coagulant.The results showed that when the dosage of PFS was 0.5 g/L and pH was 5.0,the removal rate could reach 82.14%,which was better than PAC and AS,indicating that PFS had better coagulation and sedimentation performance for PE;the composite coagulant of PFS+PAC+AS(1 g/L+0.2 g/L+0.2 g/L,pH was 5.0)had the highest removal rate of PE,reaching 96.06%;the removal rate of PE increased with the increase in sedimentation time,but considering that the longer sedimentation time has less contribution to the improvement of removal rate,it is recommended that 4 h is appropriate. 展开更多
关键词 Microplastics Coagulating sedimentation polyethylene(PE) REMOVAL
下载PDF
Effect of Polyethylene Terephthalate Plastic Waste on the Physico-Mechanical and Thermal Characteristics of Stabilized Laterite Bricks
10
作者 Aboubacar Sidiki Toure Moussa Tamboura +4 位作者 Antoine Padou Diarra Adama Coulibaly Dodo Kayentao Kélétigui Daou Mah Fatoumata Traore 《Open Journal of Applied Sciences》 2023年第6期910-920,共11页
The present work investigated the effect of polyethylene terephthalate (PET) plastic waste on the physico-mechanical and thermal properties of cement-stabilized laterite bricks to see the durability of the modified br... The present work investigated the effect of polyethylene terephthalate (PET) plastic waste on the physico-mechanical and thermal properties of cement-stabilized laterite bricks to see the durability of the modified bricks (CSLB). Samples were formulated by mixing laterite, cement, and different percentages of PET (0%, 3%, 5%, and 7%) by volume. The bricks were produced using the M7MI Hydraform standard interlocking block and kept in the shade for a curing period of 28 days. The addition of 3% to 5% PET to the laterite stabilized with 10% cement results in a decrease in both dry and wet compressive strength, which is determined using the Controlab compression machine. However, the obtained results are in concordance with the standards. The thermal conductivity of CSLB, determined using the box method with the EI700 measurement cell, decreases as the PET content of the mixture increases. A decrease in bulk density from 1.67 to 1.58 g/cm<sup>3</sup> was observed. 展开更多
关键词 Plastic Waste polyethylene Terephthalate Laterite Bricks Cement Stabilization Thermal Conductivity
下载PDF
Synthesis of Activated Carbon from Polyethylene Terephthalate(PET)Plastic Waste and Its Application for Removal of Organic Dyes from Water
11
作者 Thu Hanh Thi Pham 《Non-Metallic Material Science》 2023年第1期27-37,共11页
Synthetic plastics are often considered to be materials that cannot be broken down by natural processes.One such plastic,polyethylene terephthalate(PET),is commonly used in everyday items but when these products are d... Synthetic plastics are often considered to be materials that cannot be broken down by natural processes.One such plastic,polyethylene terephthalate(PET),is commonly used in everyday items but when these products are discarded,they can cause serious harm to the environment and human health.In this study,PET plastic waste was used to create activated carbon using a physical activation process that involved using CO2 gas.The researchers investigated the effects of different temperatures,carbonization,and activation times on the resulting activated carbon’s surface area.The activated carbon was then analyzed using scanning electron microscopy(SEM),X-ray diffraction(XRD),FTIR,and BET.The activated carbon created from PET plastic waste showed excellent absorption properties for methylene blue in aqueous solutions across a wide range of pH levels.By creating activated carbon from plastic waste,not only are environmental issues addressed,but high-value activated carbon is produced for environmental remediation purposes. 展开更多
关键词 Plastic waste Environmental treatment Activated carbon Waste utilization polyethylene terephthalate(PET)
下载PDF
Optimization of Extrusion Process Parameters of Recycled High-Density Polyethylene-Thermoplastic Starch Composite for Fused Filament Fabrication
12
作者 Grace Njeri Wamuti James Wamai Mwangi +2 位作者 Samuel Kabini Karanja Leif Micke Henning Zeidler 《Open Journal of Composite Materials》 2023年第4期69-86,共18页
High-density poly-ethylene (HDPE) is a nonbiodegradable recyclable plastic which is widely utilized in single use packaging applications. Consequently, it constitutes a significant amount of plastic waste found in lan... High-density poly-ethylene (HDPE) is a nonbiodegradable recyclable plastic which is widely utilized in single use packaging applications. Consequently, it constitutes a significant amount of plastic waste found in landfills. From literature, it has been shown that parts produced using composites of HDPE with carbohydrate-based polymers, such as thermoplastic starch (TPS), experience mechanical degradation through hydrolytic degradation process. The possible utilization of recycled-HDPE (rHDPE) and TPS composite in nonconventional manufacturing processes such as Fused filament fabrication (FFF) has however not been explored. This study explores the potential application of rHDPE and TPS composites in FFF and optimizes the extrusion process parameters used in rHDPE-TPS filament production process. Taguchi method was utilized to analyze the extrusion process. The extrusion process parameters studied were the spooling speed, extrusion speed and the extrusion temperatures. The response variable studied was the filament diameter. In this research, the maximum TPS content achieved during filament production was 40 wt%. This filament was however challenging to use in FFF printers due to frequent nozzle clogging. Printing was therefore done with filaments that contained 0 - 30 wt% TPS. The experimental results showed that the most significant parameter in extrusion process was the spooling speed, followed by extrusion speed. Extrusion temperature had the least significant influence on the filament diameter. It was observed that increase in TPS content resulted in reduced warping and increased rate of hydrolytic degradation. Mechanical properties of printed parts were investigated and the results showed that increasing TPS content resulted in reduction in tensile strength, reduction in compression strength and increase in stiffness. The findings of this research provide valuable insights to plastic recycling industries and researchers regarding the utilization of recycled HDPE and TPS composites as substitute materials in FFF. 展开更多
关键词 Additive Manufacturing (AM) Fused Filament Fabrication (FFF) High Density polyethylene (HDPE) Thermoplastic Starch (TPS) Bio-Composite
下载PDF
THERMAL BEHAVIOR OF THERMOTROPIC HYDROXYETHYL CELLULOSE ACETATE/POLYETHYLENE BLENDS
13
作者 王海琳 陈进明 +1 位作者 黄勇 沈家瑞 《Chinese Journal of Polymer Science》 SCIE CAS CSCD 1997年第1期57-64,共8页
The thermal behavior of thermotropic hydroxythyl cellulose acetate (HECA)/polyethy-lene (PE) blends has been studied by DSC. It is found that the blends of HECA and PEare immiscible but the crystallization of PE is af... The thermal behavior of thermotropic hydroxythyl cellulose acetate (HECA)/polyethy-lene (PE) blends has been studied by DSC. It is found that the blends of HECA and PEare immiscible but the crystallization of PE is affected by HECA chains in the blends withmore than 50% HECA, which results in the subordinate crystallization of PE and the for-mation of imperfect structures in the PE crystals. The imperfection of PE crystals in theblends can be eliminated after annealing at 393K. 展开更多
关键词 Hydroxyethyl CELLULOSE acetate/polyethylene BLENDS Thermal behavior polyethylene BLENDS
下载PDF
Highly cross-linked versus conventional polyethylene inserts in total hip arthroplasty,a five-year Roentgen stereophotogrammetric analysis randomised controlled trial
14
作者 Justin van Loon Daniël Hoornenborg +3 位作者 Inger Sierevelt Kim TM Opdam Gino MMJ Kerkhoffs Daniël Haverkamp 《World Journal of Orthopedics》 2020年第10期442-452,共11页
BACKGROUND Polyethylene(PE)particles produced by wear of the acetabular insert are thought to cause osteolysis and thereby aseptic loosening of the implant in total hip arthroplasty(THA).As highly cross-linked polyeth... BACKGROUND Polyethylene(PE)particles produced by wear of the acetabular insert are thought to cause osteolysis and thereby aseptic loosening of the implant in total hip arthroplasty(THA).As highly cross-linked polyethylene(HXLPE)is presumed to give lower wear rates,in vivo studies are needed to confirm this.AIM To compare the wear of REXPOL,a HXPLE,with conventional PE within the first five years after implantation using Roentgen stereophotogrammetric analysis(RSA).METHODS Patients were randomised to receive either a HXLPE(REXPOL)or a conventional PE insert during primary THA.RSA images were obtained directly postoperative and after 6 wk,12 wk,6 mo,12 mo,24 mo and five years.Functional outcomes were assessed using the Hip Injury and Osteoarthritis Outcome Score and Harris Hip Score at baseline and five years after surgery.RESULTS The HXLPE(REXPOL)showed less wear in the latero-medial direction.Significant wear rates of conventional PE were seen in the latero-medial and center-proximal direction and in volume and corrected volume,whereas the REXPOL did not show these outcomes over time.Improvement from baseline in functional outcome did not significantly differ.CONCLUSION Total 3D wear is less in THAs inserted with a REXPOL inlay than a conventional PE inlay after five years.This study confirms,for the first,that the REXPOL HXLPE inlay is preferred to standard PE. 展开更多
关键词 Highly cross-linked polyethylene Primary total hip arthroplasty polyethylene wear Roentgen stereophotogrammetric analysis
下载PDF
Bisacodyl plus split 2-L polyethylene glycol-citrate-simethicone improves quality of bowel preparation before screening colonoscopy 被引量:10
15
作者 Flavio Valiante Angelo Bellumat +1 位作者 Manuela De Bona Michele De Boni 《World Journal of Gastroenterology》 SCIE CAS 2013年第33期5493-5499,共7页
AIM:To compare the bowel cleansing efficacy,tolerability and acceptability of split 2-L polyethylene glycol(PEG)-citrate-simethicone(PEG-CS)plus bisacodyl(BIS)vs 4-L PEG for fecal occult blood test-positive screening ... AIM:To compare the bowel cleansing efficacy,tolerability and acceptability of split 2-L polyethylene glycol(PEG)-citrate-simethicone(PEG-CS)plus bisacodyl(BIS)vs 4-L PEG for fecal occult blood test-positive screening colonoscopy.METHODS:This was a randomised,observer-blind comparative study.Two hundred and sixty-four subjects underwent screening colonoscopy(mean age 62.5±7.4years,male 61.7%).The primary objective of the study was to compare the bowel cleansing efficacy of the two preparations.Interventions:BIS plus PEG-CS:3 tablets of 5-mg BIS at 16:00,PEG-CS 1-L at 19:00 and 1-L at7:00,4-L PEG:3-L at 17:00,and 1-L at 7:00.Colonoscopy was carried out after 11:00,at least 3 h after the completion of bowel preparation.Bowel cleansing was evaluated using the Harefield Cleansing Scale.RESULTS:Bowel preparation was successful for 92.8%of subjects in the PEG-CS group and for 92.1%of subjects in the 4-L PEG(RR=1.01;95%CI:0.94-1.08).BIS+PEG-CS was better tolerated than 4-L PEG.A greater rate of patients in the BIS+PEG-CS group had no difficulty and/or were willing to repeat the same preparation compared to split-dose 4-L PEG group.Subjects in the BIS+PEG-CS group rated the prep as good or satisfactory in 90.6%as compared to 77%in the 4-L PEG(P=0.003).Subjects receiving BIS+PEGCS stated they fully adhered to instructions drinking all the 2-L solution in 97.1%compared with 87.3%in the4-L PEG(P=0.003).CONCLUSION:BIS plus split 2-L PEG-CS was as effective as but better tolerated and accepted than split4-L PEG for screening colonoscopy.This new procedure may increase the positive attitude and participation to colorectal cancer screening colonoscopy. 展开更多
关键词 COLONOSCOPY Colon CLEANSING Bowel preparations polyethylene GLYCOL SIMETHICONE BISACODYL
下载PDF
Randomized controlled trial of sodium phosphate tablets vs polyethylene glycol solution for colonoscopy bowel cleansing 被引量:9
16
作者 Yoon Suk Jung Chang Kyun Lee +3 位作者 Hyo Jong Kim Chang Soo Eun Dong Soo Han Dong Ⅱ Park 《World Journal of Gastroenterology》 SCIE CAS 2014年第42期15845-15851,共7页
AIM:To compare efficacy,patient compliance,acceptability,satisfaction,safety,and adenoma detection rate of sodium phosphate tablets(NaP,CLICOLONTM)to a standard 4 L polyethylene glycol(PEG)solution for bowel cleansing... AIM:To compare efficacy,patient compliance,acceptability,satisfaction,safety,and adenoma detection rate of sodium phosphate tablets(NaP,CLICOLONTM)to a standard 4 L polyethylene glycol(PEG)solution for bowel cleansing for adults undergoing colonoscopy.METHODS:In this multicenter,randomized,prospective,investigator-blind study,the relatively young(19-60years)healthy outpatients without comorbidity were randomly assigned to one of two arms.All colonoscopy were scheduled in the morning.The NaP group was asked to take 4 tablets,5 times the evening before and4 tablets,3 times early on the morning of the colonoscopy.The PEG group was asked to ingest 2 L of solution the evening before and 2 L early in the morning of the procedure.Adequacy of bowel preparation was scored using the Boston bowel preparation scale.RESULTS:No significant differences were observed between the NaP group(n=158)and PEG group(n=162)in bowel cleansing quality(adequate preparation93.0%vs 92.6%,P=0.877),patient compliance(P=0.228),overall adverse events(63.3%vs 69.1%,P=0.269),or adenoma detection rate(34.8%vs 35.2%,P=0.944).Patient acceptability,satisfaction,and patient rating of taste were higher in the NaP group than in the PEG group(P<0.001).CONCLUSION:NaP tablets,compared with PEG solution,produced equivalent colon cleansing,did not cause more side effects,and had better patient acceptability and satisfaction in the relatively young(age<60years)healthy individuals without comorbidity.An oral tablet formulation could make bowel preparation less burdensome,resulting in greater patient participation in screening programs. 展开更多
关键词 Sodium phosphate TABLETS polyethylene GLYCOL COLON
下载PDF
Role of polyethylene particles in peri-prosthetic osteolysis:A review 被引量:11
17
作者 Gerald J Atkins David R Haynes +1 位作者 Donald W Howie David M Findlay 《World Journal of Orthopedics》 2011年第10期93-101,共9页
There is convincing evidence that particles produced by the wear of joint prostheses are causal in the periprosthetic loss of bone,or osteolysis,which,if it progresses,leads to the phenomenon of aseptic loosening.It i... There is convincing evidence that particles produced by the wear of joint prostheses are causal in the periprosthetic loss of bone,or osteolysis,which,if it progresses,leads to the phenomenon of aseptic loosening.It is important to fully understand the biology of this bone loss because it threatens prosthesis survival,and loosened implants can result in peri-prosthetic fracture,which is disastrous for the patient and presents a difficult surgical scenario.The focus of this review is the bioactivity of polyethylene(PE)particles,since there is evidence that these are major players in the development and progression of osteolysis around prostheses which use PE as the bearing surface.The review describes the biological consequences of interaction of PE particles with macrophages,osteoclasts and cells of the osteoblast lineage,including osteocytes.It explores the possible cellular mechanisms of action of PE and seeks to use the findings to date to propose potential nonsurgical treatments for osteolysis.In particular,a nonsurgical approach is likely to be applicable to implants containing newer,highly cross-linked PEs(HXLPEs),for which osteolysis seems to occur with much reduced PE wear compared with conventional PEs.The caveat here is that we know little as yet about the bioactivity of HXLPE particles and addressing this constitutes our next challenge. 展开更多
关键词 polyethylene ASEPTIC LOOSENING OSTEOLYSIS WEAR particle Peri-prosthetic
下载PDF
Effect of exogenous spastin combined with polyethylene glycol on sciatic nerve injury 被引量:4
18
作者 Yao-Fa Lin Zheng Xie +3 位作者 Jun Zhou Hui-Hao Chen Wan-Wan Shao Hao-Dong Lin 《Neural Regeneration Research》 SCIE CAS CSCD 2019年第7期1271-1279,共9页
Polyethylene glycol can connect the distal and proximal ends of an injured nerve at the cellular level through axonal fusion to avoid Wallerian degeneration of the injured distal nerve and promote peripheral nerve reg... Polyethylene glycol can connect the distal and proximal ends of an injured nerve at the cellular level through axonal fusion to avoid Wallerian degeneration of the injured distal nerve and promote peripheral nerve regeneration.However,this method can only prevent Wallerian degeneration in 10% of axons because the cytoskeleton is not repaired in a timely fashion.Reconstruction of the cytoskeletal trunk and microtubule network has been suggested to be the key for improving the efficiency of axonal fusion.As a microtubule-severing protein,spastin has been used to enhance cytoskeletal reconstruction.Therefore,we hypothesized that spastin combined with polyethylene glycol can more effectively promote peripheral nerve regeneration.A total of 120 male Sprague-Dawley rats were randomly divided into sham,suture,polyethylene glycol,and polyethylene glycol + spastin groups.In suture group rats,only traditional nerve anastomosis of the end-to-end suture was performed after transection of the sciatic nerve.In polyethylene glycol and polyethylene glycol + spastin groups,50 μL of polyethylene glycol or 25 μL of polyethylene glycol + 25 μL of spastin,respectively,were injected immediately under the epineurium of the distal suture.Sensory fiber regeneration distance,which was used to assess early nerve regeneration at 1 week after surgery,was shortest in the suture group,followed by polyethylene glycol group and greatest in the polyethylene glycol + spastin group.Behavioral assessment of motor function recovery in rats showed that limb function was restored in polyethylene glycol and polyethylene glycol + spastin groups at 8 weeks after surgery.At 1,2,4 and 8 weeks after surgery,sciatic functional index values and percentages of gastrocnemius muscle wet weight were highest in the sham group,followed by polyethylene glycol + spastin and polyethylene glycol groups,and lowest in the suture group.Masson staining was utilized to assess the morphology of muscle tissue.Morphological changes in skeletal muscle were detectable in suture,polyethylene glycol,and polyethylene glycol + spastin groups at 1,2,4,and 8 weeks after surgery.Among them,muscular atrophy of the suture group was most serious,followed by polyethylene glycol and polyethylene glycol + spastin groups.Ultrastructure of distal sciatic nerve tissue,as detected by transmission electron microscopy,showed a pattern of initial destruction,subsequent disintegration,and gradual repair in suture,polyethylene glycol,and polyethylene glycol + spastin groups at 1,2,4,and8 weeks after surgery.As time proceeded,axonal ultrastructure gradually recovered.Indeed,the polyethylene glycol + spastin group was similar to the sham group at 8 weeks after surgery.Our findings indicate that the combination of polyethylene glycol and spastin can promote peripheral nerve regeneration.Moreover,the effect of this combination was better than that of polyethylene glycol alone,and both were superior to the traditional neurorrhaphy.This study was approved by the Animal Ethics Committee of the Second Military Medical University,China(approval No.CZ20170216) on March 16,2017. 展开更多
关键词 NERVE REGENERATION PERIPHERAL NERVES Wallerian degeneration polyethylene glycol axonal fusion SPASTIN PERIPHERAL NERVE injuries MASSON staining microtubule neural REGENERATION
下载PDF
Polyethylene glycol microspheres loaded with irinotecan for arterially directed embolic therapy of metastatic liver cancer 被引量:6
19
作者 Giammaria Fiorentini Riccardo Carandina +9 位作者 Donatella Sarti Michele Nardella Odysseas Zoras Stefano Guadagni Riccardo Inchingolo Massimiliano Nestola Alessandro Felicioli Daniel Barnes Navarro Fernando Munoz Gomez Camillo Aliberti 《World Journal of Gastrointestinal Oncology》 SCIE CAS 2017年第9期379-384,共6页
AIM To study tumor response, and tolerability of arterially directed embolic therapy(ADET) with polyethylene glycol embolics loaded with irinotecan for the treatment of colorectal cancer liver metastases(CRC-LM). Seco... AIM To study tumor response, and tolerability of arterially directed embolic therapy(ADET) with polyethylene glycol embolics loaded with irinotecan for the treatment of colorectal cancer liver metastases(CRC-LM). Secondary objectives were to monitor quality of life, time to progression and survival of patients.METHODS Patients were included in the study if they were affected by CRC-LM, refractory to systemic chemotherapy, treated with ADET using polyethylene glycol embolics, and had liver involvement < 50%. Tumor response, performance status(PS), tumor marker antigens, and quality of life(QoL) were monitored at 1, 3 and 6 mo after ADET. QoL was assessed with the Palliative Performance Scale(PPS).RESULTS We treated 50 consecutive CRC-LM patients with ADET using polyethylene glycol embolics. Their tumor response one month after ADET was: 28% of complete response(CR), 48% of partial response(PR), 8% stable disease(SD), and 16% of progression. Tumor response 3 mo after ADET was CR 24%, PR 38%, SD 19% and progression disease(PD) 19%. Tumor response 6 mo after ADET was CR 18%, PR 44%, SD 21% and PD 18%. QoL was 90% PPS at each time point. Median time to progression for patients who progressed was 2.5 mo(range 0.8-6). Median follow-up was 14 mo(0.8-25 range). ADETs were performed with no complications. Observed side effects(mild or moderate intensity) were: Pain in 32% of patients, increase of transaminase levels in 20% and fever in 14%, whereas 30% of patients did not complain any adverse event. CONCLUSION The treatment of unresectable CRC-LM with ADET using polyethylene glycol microspheres loaded with irinotecan was effective in tumor response and resulted in mild toxicity, and good QoL. 展开更多
关键词 Liver metastases Arterially directed embolic therapy Colorectal cancer polyethylene glycol embolics IRINOTECAN
下载PDF
PREPARATION OF MICROPOROUS ULTRA HIGH MOLECULAR WEIGHT POLYETHYLENE (UHMWPE) BY THERMALLY INDUCED PHASE SEPARATION OF A UHMWPE/LIQUID PARAFFIN MIXTURE 被引量:7
20
作者 沈烈 《Chinese Journal of Polymer Science》 SCIE CAS CSCD 2008年第6期653-657,共5页
Ultra-high molecular weight polyethylene (UHMWPE) with a microporous structure was prepared via thermally induced phase separation (TIPS).Liquid paraffin (LP) was used as a diluent in the preparation of microporous UH... Ultra-high molecular weight polyethylene (UHMWPE) with a microporous structure was prepared via thermally induced phase separation (TIPS).Liquid paraffin (LP) was used as a diluent in the preparation of microporous UHMWPE. Small angle laser light scattering (SALLS) and differential scanning calorimetry (DSC) were used to determine the phase separation temperatures,i.e.the cloud points and the dynamic crystallization temperatures,respectively.It was found that the cloudI points were coincident with the cr... 展开更多
关键词 Ultra high molecular weight polyethylene Thermally induced phase separation Liquid paraffin.
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部