期刊文献+
共找到395篇文章
< 1 2 20 >
每页显示 20 50 100
Enhancing Precision in Radiotherapy Delivery: Validating Monte Carlo Simulation Models for 6 MV Elekta Synergy Agility LINAC Photon Beam Using Two Models of the GAMOS Code
1
作者 Nogaye Ndiaye Oumar Ndiaye +7 位作者 Papa Macoumba Faye Kodjo Joël Fabrice N’Guessan Djicknack Dione Khady Sy Moussa Hamady Sy Jean Paul Latyr Faye Alassane Traoré Ababacar Sadikhe Ndao 《World Journal of Nuclear Science and Technology》 CAS 2024年第2期146-163,共18页
The most crucial requirement in radiation therapy treatment planning is a fast and accurate treatment planning system that minimizes damage to healthy tissues surrounding cancer cells. The use of Monte Carlo toolkits ... The most crucial requirement in radiation therapy treatment planning is a fast and accurate treatment planning system that minimizes damage to healthy tissues surrounding cancer cells. The use of Monte Carlo toolkits has become indispensable for research aimed at precisely determining the dose in radiotherapy. Among the numerous algorithms developed in recent years, the GAMOS code, which utilizes the Geant4 toolkit for Monte Carlo simula-tions, incorporates various electromagnetic physics models and multiple scattering models for simulating particle interactions with matter. This makes it a valuable tool for dose calculations in medical applications and throughout the patient’s volume. The aim of this present work aims to vali-date the GAMOS code for the simulation of a 6 MV photon-beam output from the Elekta Synergy Agility linear accelerator. The simulation involves mod-eling the major components of the accelerator head and the interactions of the radiation beam with a homogeneous water phantom and particle information was collected following the modeling of the phase space. This space was po-sitioned under the X and Y jaws, utilizing three electromagnetic physics mod-els of the GAMOS code: Standard, Penelope, and Low-Energy, along with three multiple scattering models: Goudsmit-Saunderson, Urban, and Wentzel-VI. The obtained phase space file was used as a particle source to simulate dose distributions (depth-dose and dose profile) for field sizes of 5 × 5 cm<sup>2</sup> and 10 × 10 cm<sup>2</sup> at depths of 10 cm and 20 cm in a water phantom, with a source-surface distance (SSD) of 90 cm from the target. We compared the three electromagnetic physics models and the three multiple scattering mod-els of the GAMOS code to experimental results. Validation of our results was performed using the gamma index, with an acceptability criterion of 3% for the dose difference (DD) and 3 mm for the distance-to-agreement (DTA). We achieved agreements of 94% and 96%, respectively, between simulation and experimentation for the three electromagnetic physics models and three mul-tiple scattering models, for field sizes of 5 × 5 cm<sup>2</sup> and 10 × 10 cm<sup>2</sup> for depth-dose curves. For dose profile curves, a good agreement of 100% was found between simulation and experimentation for the three electromagnetic physics models, as well as for the three multiple scattering models for a field size of 5 × 5 cm<sup>2</sup> at 10 cm and 20 cm depths. For a field size of 10 × 10 cm<sup>2</sup>, the Penelope model dominated with 98% for 10 cm, along with the three multiple scattering models. The Penelope model and the Standard model, along with the three multiple scattering models, dominated with 100% for 20 cm. Our study, which compared these different GAMOS code models, can be crucial for enhancing the accuracy and quality of radiotherapy, contributing to more effective patient treatment. Our research compares various electro-magnetic physics models and multiple scattering models with experimental measurements, enabling us to choose the models that produce the most reli-able results, thereby directly impacting the quality of simulations. This en-hances confidence in using these models for treatment planning. Our re-search consistently contributes to the progress of Monte Carlo simulation techniques in radiation therapy, enriching the scientific literature. 展开更多
关键词 GAMOS Monte Carlo linac RADIOTHERAPY Dose Distribution Phase Space Gamma Index 6 MV Photon Beam
下载PDF
基于国产加速器URT-Linac 506c的计划复杂度分析和患者计划质量保证预测
2
作者 祝鹤龄 杨波 +5 位作者 祝起禛 梁永广 杨景茹 王贝 王嘉欣 邱杰 《中国医疗设备》 2024年第1期29-34,共6页
目的 探讨基于国产联影URT-Linac 506c加速器的容积弧形调强放射治疗(Volumetric Modulated Arc Therapy,VMAT)计划复杂度参数与患者计划质量保证(Patient Specific Quality Assurance,PSQA)间的关系,并建立机器学习模型对PSQA结果进行... 目的 探讨基于国产联影URT-Linac 506c加速器的容积弧形调强放射治疗(Volumetric Modulated Arc Therapy,VMAT)计划复杂度参数与患者计划质量保证(Patient Specific Quality Assurance,PSQA)间的关系,并建立机器学习模型对PSQA结果进行评估和预测。方法 随机选取150例在URT-Linac 506c加速器上行VMAT治疗计划的患者为研究对象,在该加速器上对所有计划进行基于机载电子射野影像系统探测器的PSQA剂量验证。对剂量验证结果进行阈值为10%、标准为2%/2 mm的伽马通过率分析。同时对每个计划基于多叶准直器位置和跳数,提取其中的11个复杂度参数。分析复杂度参数和PSQA结果间的关系,并建立机器学习模型对PSQA结果进行预测。结果 计划复杂度参数与PSQA结果的相关性分析表明二者并不严格呈线性相关,但计划的复杂程度越高,PSQA通过率相对越低。梯度提升决策树(Gradient Boosting Decision Tree,GBDT)模型和随机森林(Random Forest,RF)模型对基于复杂度参数的PSQA结果预测水平相当,GBDT模型和RF模型的平均预测误差分别为0.55%和0.54%。由于PSQA结果分布严重不平衡,更改过权重后的模型对低通过率部分的预测能力有所提升。结论 对于国产加速器URT-Linac 506c,这2种基于决策树结构的机器学习模型对PSQA结果的预测可提供一定的帮助,建立更精准的模型需要进一步完善采集患者的样本量。 展开更多
关键词 联影URT-linac 506c加速器 计划复杂度 机器学习 患者计划质量保证
下载PDF
瓦里安Clinac 23EX常见GFIL连锁系统故障分析 被引量:5
3
作者 卢联中 余辉 王琳婧 《医疗装备》 2017年第9期44-46,共3页
根据加速器电子枪控制系统原理,利用数字万用表、示波器、高压棒等进行有关参数的测量对比,对该机器出现GFIL连锁故障进行测量和比较分析,找出其根本原因,总结该机器GFIL连锁,实现GFIL连锁出现时进行快速维修,为患者缩短等候时间。瓦里... 根据加速器电子枪控制系统原理,利用数字万用表、示波器、高压棒等进行有关参数的测量对比,对该机器出现GFIL连锁故障进行测量和比较分析,找出其根本原因,总结该机器GFIL连锁,实现GFIL连锁出现时进行快速维修,为患者缩短等候时间。瓦里安23EX加速器常见的GFIL连锁故障维修效果较好,提高了机器的稳定性能、显著减少相关联故障的发生,提高了开机率。 展开更多
关键词 瓦里安 Clinac 直线加速器 GFIL 连锁
下载PDF
基于LINAC慢正电子源的EGS4模拟
4
作者 于润升 魏龙 +5 位作者 裴国玺 王宝义 陈红民 张天保 孟伯年 李大庆 《核技术》 EI CAS CSCD 北大核心 2000年第6期405-410,共6页
介绍基于BEPCLINAC和BFELLINAC(北京正负电子对撞机和北京自由电子激光装置电子直线加速器)慢正电子束设备中正电子源部分的Monte-Carlo模拟过程。结果表明,从Ta靶出射的快正电子产额在BEPCLINAC和BFELMNAC运行于兼容模式时分别为18... 介绍基于BEPCLINAC和BFELLINAC(北京正负电子对撞机和北京自由电子激光装置电子直线加速器)慢正电子束设备中正电子源部分的Monte-Carlo模拟过程。结果表明,从Ta靶出射的快正电子产额在BEPCLINAC和BFELMNAC运行于兼容模式时分别为184×1010/s和3.9×1011/s。若慢化体慢化效率在10-4量级,基于BEPCLINAC和BFELLINAC慢正电子束的慢正电子产额分别为106-107/s和107-108/s。 展开更多
关键词 慢正电子束流设备 EGS4程序 慢正电子源 linac
下载PDF
医用电子直线加速器生产环节风险分析及现场体系核查要点
5
作者 杨义强 《中国医疗器械杂志》 2024年第2期212-216,共5页
医用电子直线加速器具有系统结构复杂、核心部件多、控制精度要求高等特点,对产品质量控制和监管都提出了较高的要求。该研究通过对医用电子直线加速器技术特点及生产环节风险分析,结合医疗器械生产质量管理规范要求,提出了此类产品现... 医用电子直线加速器具有系统结构复杂、核心部件多、控制精度要求高等特点,对产品质量控制和监管都提出了较高的要求。该研究通过对医用电子直线加速器技术特点及生产环节风险分析,结合医疗器械生产质量管理规范要求,提出了此类产品现场体系检查要点,对企业的质量管理人员和监管部门的检查员具有一定参考意义。 展开更多
关键词 医用电子直线加速器 生产风险 现场体系核查 生产质量管理规范
下载PDF
Clinac iX和Trilogy加速器束流匹配计划验证分析 被引量:1
6
作者 王广善 刘桂梅 +2 位作者 李晓波 李祥勇 张旭 《中国医学物理学杂志》 CSCD 2021年第1期15-20,共6页
通过对束流匹配的加速器进行计划设计,比较计划参数,验证交叉执行的差异及通过率,验证束流匹配的可行性及可靠性。选取头颈、胸部和腹盆部共15例病例,分别设计Clinac iX和Trilogy两个不同治疗机的三维适形计划(3D-CRT);另选头颈、胸部... 通过对束流匹配的加速器进行计划设计,比较计划参数,验证交叉执行的差异及通过率,验证束流匹配的可行性及可靠性。选取头颈、胸部和腹盆部共15例病例,分别设计Clinac iX和Trilogy两个不同治疗机的三维适形计划(3D-CRT);另选头颈、胸部和腹盆部共15例病例,分别设计两个不同治疗机的调强计划(IMRT)。比较相同计划类型不同治疗机的计划差异,评价指标包括靶区PTV的D98%、D2%、Dmax,晶体Dmax、脑干Dmax、左右肺V5 Gy、双肺V20 Gy、脊髓Dmax、膀胱D50%、小肠D2 cc、股骨头V40 Gy等危及器官及治疗机跳数MU。并对治疗机执行计划进行点剂量和面剂量验证。PTV的D98%、D2%、Dmax剂量差异最大平均值标准差分别为-0.52%±0.30%、0.53%±0.45%、-0.55%±0.17%,危及器官剂量差异最大平均值为膀胱D50%(0.94%±0.84%);Clinac iX和Trilogy治疗机执行所有计划的最大绝对剂量偏差分别为2.36%和-2.80%。MatriXX和PV的γ验证通过率结果平均值分别在97.00%和96.00%以上,Clinac iX最小值为95.40%,Trilogy最小值为95.90%。两台经过束流匹配的治疗机之间交换执行计划的剂量学偏差在临床可接受的范围内,各项参数能精准执行,必要时可以在两台治疗机之间交换执行计划,保证病人放疗疗程完整。 展开更多
关键词 加速器 束流匹配 交叉执行 计划验证 γ分析
下载PDF
Visual Analysis of the Daily QA Results of Photon and Electron Beams of a Trilogy Linac over a Five-Year Period 被引量:6
7
作者 Maria F. Chan Qiongge Li +5 位作者 Xiaoli Tang Xiang Li Jingdong Li Grace Tang Margie A. Hunt Joseph O. Deasy 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2015年第4期290-299,共10页
Data visualization technique was applied to analyze the daily QA results of photon and electron beams. Special attention was paid to any trend the beams might display. A Varian Trilogy Linac equipped with dual photon ... Data visualization technique was applied to analyze the daily QA results of photon and electron beams. Special attention was paid to any trend the beams might display. A Varian Trilogy Linac equipped with dual photon energies and five electron energies was commissioned in early 2010. Daily Linac QA tests including the output constancy, beam flatness and symmetry (radial and transverse directions) were performed with an ionization chamber array device (QA Beam Checker Plus, Standard Imaging). The data of five years were collected and analyzed. For each energy, the measured data were exported and processed for visual trending using an in-house Matlab program. These daily data were cross-correlated with the monthly QA and annual QA results, as well as the preventive maintenance records. Majority of the output were within 1% of variation, with a consistent positive/upward drift for all seven energies (^+0.25% per month). The baseline of daily device is reset annually right after the TG-51 calibration. This results in a sudden drop of the output. On the other hand, the large amount of data using the same baseline exhibits a sinusoidal behavior (period = 12 months;amplitude = 0.8%, 0.5% for photons, electrons, respectively) on symmetry and flatness when normalization of baselines is accounted for. The well known phenomenon of new Linac output drift was clearly displayed. This output drift was a result of the air leakage of the over-pressurized sealed monitor chambers for the specific vendor. Data visualization is a new trend in the era of big data in radiation oncology research. It allows the data to be displayed visually and therefore more intuitive. Based on the visual display from the past, the physicist might predict the trend of the Linac and take actions proactively. It also makes comparisons, alerts failures, and potentially identifies causalities. 展开更多
关键词 linac QA Data Visualization DAILY Output RADIOTHERAPY
下载PDF
Proton linac-based therapy facility for ultra-high dose rate (FLASH) treatment 被引量:5
8
作者 Wen-Cheng Fang Xiao-Xia Huang +10 位作者 Jian-Hao Tan Chao-Peng Wang Cheng-Cheng Xiao Yi-Xing Lu Yu Zhang Yu-Qing Yang Yi-Ming Xu Han-Yu Gong Jun-Qiang Zhang Shao-Peng Zhong Zhen-Tang Zhao 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2021年第4期1-9,共9页
As an advanced treatment method in the past five years,ultra-high dose rate(FLASH)radiotherapy as a breakthrough and milestone in radiotherapy development has been verified to be much less harmful to healthy tissues i... As an advanced treatment method in the past five years,ultra-high dose rate(FLASH)radiotherapy as a breakthrough and milestone in radiotherapy development has been verified to be much less harmful to healthy tissues in different experiments.FLASH treatments require an instantaneous dose rate as high as hundreds of grays per second to complete the treatment in less than 100 ms.Current proton therapy facilities with the spread-out of the Bragg peak formed by different energy layers,to our knowledge,cannot easily achieve an adequate dose rate for FLASH treatments because the energy layer switch or gantry rotation of current facilities requires a few seconds,which is relatively long.A new design for a therapy facility based on a proton linear accelerator(linac)for FLASH treatment is proposed herein.It is designed under two criteria:no mechanical motion and no magnetic field variation.The new therapy facility can achieve an ultrahigh dose rate of up to 300 Gy/s;however,it delivers an instantaneous dose of 30 Gy within 100 ms to complete a typical FLASH treatment.The design includes a compact proton linac with permanent magnets,a fast beam kicker in both azimuth and elevation angles,a fixed gantry with a static superconducting coil to steer proton bunches with all energy,a fast beam scanner using radio-frequency(RF)deflectors,and a fast low-level RF system.All relevant principles and conceptual proposals are presented herein. 展开更多
关键词 Proton therapy FLASH Proton linac DEFLECTOR Superconducting coil Fast scanner
下载PDF
Strip line beam position monitor for HLS LINAC 被引量:4
9
作者 LI Ji-Hao SUN Bao-Gen HE Duo-Hui LU Ping WANG Yong WANG Jun-Hua JIN Kai CAO Yong ZHENG Pu 《Nuclear Science and Techniques》 SCIE CAS CSCD 2005年第5期257-259,共3页
The parameters of beam transverse positions at HLS 200 MeV LINAC are very important to injection ef-ficiency. We have designed a new non-interceptive strip line beam position monitor (BPM) as a substitution for the or... The parameters of beam transverse positions at HLS 200 MeV LINAC are very important to injection ef-ficiency. We have designed a new non-interceptive strip line beam position monitor (BPM) as a substitution for the original interceptive fluorescent target. This paper gives out the theoretical analysis and bench test result of the strip line BPM. The BPM has a characteristic impedance of (50±5)?, a reflection coefficient of less than –4 dB, a band-width of 400 MHz, a coupling coefficient of less than -15 dB, and a sensitivity of 1.16 dB/mm. Additionally, the strip line BPM has a good linearity. 展开更多
关键词 HLS linac BPM 时域 频域 电极 灵敏性 直线性 加速器
下载PDF
What Do We Mean When We Talk about the Linac Isocenter? 被引量:1
10
作者 Mutian Zhang Su-Min Zhou Tanxia Qu 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2015年第3期233-242,共10页
Purpose: The isocenter of a medical linac system is a frequently used concept in clinical practice. However, so far not all the isocenters are rigorously defined. This work is intended as an attempt of deriving consis... Purpose: The isocenter of a medical linac system is a frequently used concept in clinical practice. However, so far not all the isocenters are rigorously defined. This work is intended as an attempt of deriving consistent and operable isocenter definitions. Methods: The isocenter definition is based on a fundamental concept, the axis of rotation of a rigid body. The axis of rotation is determined using the trajectory of any point on a plane that intersects the rigid body. A point on the axis of rotation is found through the minimal bounding sphere of the trajectory when the rigid body makes a full rotation. The essential mathematical tool of the isocenter definition system is three-dimensional coordinate transformation. Results: The axes of rotation of the linac collimator, gantry, and couch are established first. The linac mechanical isocenter (linac isocenter) is defined as the center of a circle that best fits the trajectory of a select linac X-ray source position. The axis of rotation and the minimal bounding sphere are cornerstones for the rotation isocenters of the collimator, gantry and couch. The definition of radiation isocenter incorporates a surrogate of the useful beam axis. Conclusions: A framework of isocenter definitions for medical linacs is presented in this manuscript. Consistent meanings of the mechanical and radiation isocenters can be achieved using this approach. 展开更多
关键词 Medical Linear ACCELERATOR ISOCENTER linac ISOCENTER ROTATION ISOCENTER Radiation ISOCENTER AXIS of ROTATION Definition
下载PDF
Fabrication and cold test of prototype of spatially periodic radio frequency quadrupole focusing linac 被引量:2
11
作者 Pei-Yan Yu Bin Zhang +7 位作者 Feng-Feng Wang Chen-Xing Li Guo-Zhen Sun Zhi-Jun Wang Lu-Bei Liu Chen-Zhang Yuan Yuan He Hu-Shan Xu 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2021年第1期66-74,共9页
A 325 MHz aluminum prototype of a spatially periodic RF quadrupole focusing linac was developed at the Institute of Modern Physics,Chinese Academy of Sciences,as a promising candidate for the front end of a high-curre... A 325 MHz aluminum prototype of a spatially periodic RF quadrupole focusing linac was developed at the Institute of Modern Physics,Chinese Academy of Sciences,as a promising candidate for the front end of a high-current linac.It consists of an alternating series of crossbar H-type drift tubes and RF quadrupole sections.Owing to its special geometry,cavity fabrication is a major hurdle for its engineering development and application.In this paper,we report the detailed mechanical design of this structure and describe its fabrication process,including machining,assembly,and inspection.The field distribution was measured by the bead-pull technique.The results show that the field errors of both the accelerating and focusing fields are within an acceptable range.A tuning scheme for this new structure is proposed and verified.The cold test process and results are presented in detail.The development of this prototype provides valuable guidance for the application of the spatially periodic RF quadrupole structure. 展开更多
关键词 Spatially periodic RF quadrupole focusing linac Mechanical structure design Bead-pull measurement
下载PDF
Phase control system for SSRF linac 被引量:5
12
作者 YIN Chongxian YU Luyang LIU Dekang 《Nuclear Science and Techniques》 SCIE CAS CSCD 2008年第3期129-133,共5页
The design of phase control system in Shanghai Synchrotron Radiation Facility (SSRF) linac is presented in this paper. And digital phase detecting algorithm, the key for phase control system, is fully described. The t... The design of phase control system in Shanghai Synchrotron Radiation Facility (SSRF) linac is presented in this paper. And digital phase detecting algorithm, the key for phase control system, is fully described. The testing results for phase control system in 100MeV linac are discussed in detail. 展开更多
关键词 相位控制系统 直线性加速器 数字传感器 原子能
下载PDF
Commissioning experiences with the spoke-based CW superconducting proton linac 被引量:1
13
作者 Fang Yan Hui-Ping Geng +14 位作者 Cai Meng Ya-Liang Zhao Hua Shi Hua-Fu Ouyang Tong-Min Huang Fei-Si He Jian-Li Wang Rui Ge Yan-Feng Sui Qiang Ye Rong Liu Qun-Yao Wang Sheng-Chang Wang Jian-She Cao Wei-Min Pan 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2021年第10期12-29,共18页
The 10-MeV Accelerator-Driven Subcritical(ADS)system Injector-I test stand at the Institute of High Energy Physics(IHEP)is a testing facility dedicated to demonstrating the feasibility of the spoke-based super-conduct... The 10-MeV Accelerator-Driven Subcritical(ADS)system Injector-I test stand at the Institute of High Energy Physics(IHEP)is a testing facility dedicated to demonstrating the feasibility of the spoke-based super-conducting(SC)linear accelerator(linac)for the ADS project in China.The injector adopted a four-vane copper structure radio frequency quadrupole(RFQ)with an output energy of 3.2 MeV and an SC section accommodating 14 β_(g)=0.12 single spoke cavities,14 SC solenoids,and 14 cold beam position monitors(BPMs).A 10-MeV pulsed beam with a beam current of 10 mA and a 2-mA continuous wave(CW)beam were successfully shooting through.The commissioning results confirmed the feasibility of using a 325-MHz spoke-type cavity for accelerating the proton beam in the low β and medium β sections.This paper describes the results achieved,the difficulties encountered,and the experiences obtained during commissioning. 展开更多
关键词 Superconducting proton linac Spoke cavity High intensity CW commissioning
下载PDF
The waveguide system of the HLS 800 MeV Linac 被引量:1
14
作者 林宏翔 黄贵荣 +4 位作者 徐宏亮 金凯 刘勇涛 李超 赵周宇 《Nuclear Science and Techniques》 SCIE CAS CSCD 2015年第6期9-12,共4页
To upgrade Hefei Light Source(HLS) Linac, eight accelerating units have been constructed to realize fullenergy injection of the storage ring. Each of the units consists of two 3-m accelerators driven by one klystron.T... To upgrade Hefei Light Source(HLS) Linac, eight accelerating units have been constructed to realize fullenergy injection of the storage ring. Each of the units consists of two 3-m accelerators driven by one klystron.The input cavity detuning method was developed to measure and correct the phase length of the RF power distribution waveguide system. The design of the waveguide network and the principles of the detuning method are presented in this paper. After correction, the phase error between the waveguide of the two accelerators was less than ±0.5?, and the maximum electron energy of Linac reached 805 MeV, which is very near the theoretical maximum value of 810 MeV. These results demonstrate that the calibration of the waveguide was successful. 展开更多
关键词 电子直线加速器 波导系统 HLS MEV 相位误差 合肥光源 功率分布 网络设计
下载PDF
Velocity bunching for the linac of Shanghai Deep UV FEL facility 被引量:2
15
作者 ZHANG Meng GU Duan +4 位作者 GU Qiang LIN Guoqiang LAN Taihe WANG Xingtao DENG Haixiao 《Nuclear Science and Techniques》 SCIE CAS CSCD 2012年第3期134-138,共5页
High brightness electron beam is one of the main goals of the research and development effort in RF photo-injectors.Compared with the normally used magnetic chicane,an alternative scheme,commonly known as 'velocit... High brightness electron beam is one of the main goals of the research and development effort in RF photo-injectors.Compared with the normally used magnetic chicane,an alternative scheme,commonly known as 'velocity bunching',has been proposed as a tool to compress electron beam pulses in modern high brightness photo-injector sources.This paper presents numerical optimization systematically and the first attempt to demonstrate the velocity bunching scheme on SDUV-FEL linac experimentally.The relationship between the degree of bunching and the off-crest phase of the accelerating structure is explored experimentally.Velocity bunching operating mode illustrates flexible performances with an intrinsic machine jitter,which agrees well with the theoretical prediction. 展开更多
关键词 速度聚束 直线加速器 自由电子激光 深紫外 高亮度电子束 设施 上海 调制解调器
下载PDF
BEPCII Injector Linac Upgrade and Beam Instabilities 被引量:2
16
作者 王书鸿 裴国玺 +10 位作者 池云龙 陈延伟 曹建社 孔祥成 赵风利 侯泪 刘渭滨 耿哲峤 裴士伦 邓秉林 陈志比 《Chinese Physics Letters》 SCIE CAS CSCD 2008年第5期1636-1639,共4页
The upgrade project of the Beijing Electron Positron Collider (BEPCII) and its injector linac is working well. The linac upgrade aims at a higher injection rate of 5OmA/min into the storage ring, which requires an i... The upgrade project of the Beijing Electron Positron Collider (BEPCII) and its injector linac is working well. The linac upgrade aims at a higher injection rate of 5OmA/min into the storage ring, which requires an injected beam with low emittance, low energy spread and high beam orbit and energy stabilities. This goal is finally reached recently by upgrading the linac components and by dealing with rich and practical beam physics, which are described in this study. 展开更多
关键词 II-linac PHASING SYSTEM DESIGN ORBIT
原文传递
Cryogenic system design for HIAF iLinac 被引量:2
17
作者 Xiao-Fei Niu Feng Bai +3 位作者 Xian-Jin Wang Jun-Hui Zhang Xiao-Hong Guo Da-Ming Sun 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第12期48-57,共10页
A helium cryogenic system is designed by the Institute of Modern Physics,Chinese Academy of Sciences,to supply different cooling powers to the cryomodules of ion-Linac(iLinac)accelerator,which serves as the injector o... A helium cryogenic system is designed by the Institute of Modern Physics,Chinese Academy of Sciences,to supply different cooling powers to the cryomodules of ion-Linac(iLinac)accelerator,which serves as the injector of the High Intensity Heavy-Ion Accelerator Facility project.The iLinac is a superconducting heavy-ion accelerator approximately 100 m long and contains 13 cryomodules cooled by superfluid helium.This article describes the cryogenic system design of the iLinac accelerator.The requirements of the cryogenic system,such as cooling mode,refrigeration temperature,operating pressure and pressure stability,are introduced and described in detail.In addition,heat loads from different sources are analyzed and calculated quantitatively.An equivalent cooling capacity of 10 kW at 4.5 K was determined for the cryogenic system according to the total heat load.Furthermore,a system process design was conducted and analyzed in detail.Further,the system layout and the main equipment are presented. 展开更多
关键词 Ion-linac(ilinac)accelerator SUPERFLUID liquid HELIUM CRYOGENIC system Cryomodule
下载PDF
Decommissioning analysis of the scrapers in the NSRL Linac using depth profiling 被引量:1
18
作者 何丽娟 李裕熊 +2 位作者 李为民 陈裕凯 任广益 《Nuclear Science and Techniques》 SCIE CAS CSCD 2015年第6期13-18,共6页
For a high-energy electron facility, estimates of induced radioactivity in materials are of considerable importance to ensure that the exposure of personnel and the environment remains as low as reasonably achievable.... For a high-energy electron facility, estimates of induced radioactivity in materials are of considerable importance to ensure that the exposure of personnel and the environment remains as low as reasonably achievable. In addition, accurate predictions of induced radioactivity are essential to the design, operation, and decommissioning of a high-energy electron linear accelerator. In the case of the 200-MeV electron linac of the National Synchrotron Radiation Laboratory(NSRL), the electrons are accelerated by five acceleration tubes and collimated by copper scrapers. The scrapers, which play a vital role in protecting the acceleration cavity, are bombarded by many electrons over a long-term operation, which causes a significant amount of induced radioactivity. Recently, the NSRL Linac is the first high-energy electron linear accelerator in China to be out of commission.Its decommissioning is highly significant for obtaining decommissioning experience. This paper focuses on the measurement of induced radioactivity on the fourth scraper, where the electron energy was 158 MeV. The radionuclides were classified according to their half-lives. Such a classification provides a reliable basis for the formulation of radiation protection and facility decommissioning. To determine the high-radioactivity area and to facilitate the decommissioning process, the slicing method was applied in this study. The specific activity of60 Co in each slice was measured at a cooling time of ten months, and the results were compared with the predictions generated by Monte Carlo program FLUKA. The trend of the measured results is in good agreement with the normalized simulation results. The slicing simulation using Monte Carlo method is useful for the determination of high-radiation areas and proper material handling protocols and, therefore, lays a foundation for the accumulation of decommissioning experience. 展开更多
关键词 电子直线加速器 核设施退役 NSRL 深度剖析 刮板 国家同步辐射实验室 放射性物质 放射性测量
下载PDF
E-linac数字化设计管理系统分析 被引量:1
19
作者 盘采华 吕建友 《无线互联科技》 2016年第22期45-47,共3页
直线加速器设计的信息化和网络化是今后加速器的发展趋势,文章在进行电子直线加速器(E-linac)数字化设计的基础上,构建了E-linac数字化设计管理系统,以解决设计管理中存在的信息共享、资源统筹差、工作协调不够等问题,提高设计管理的效... 直线加速器设计的信息化和网络化是今后加速器的发展趋势,文章在进行电子直线加速器(E-linac)数字化设计的基础上,构建了E-linac数字化设计管理系统,以解决设计管理中存在的信息共享、资源统筹差、工作协调不够等问题,提高设计管理的效率和加速器数字化设计的研究水平,以信息化推进加速器数字化设计管理体系和设计现代化,为直线加速器数字化设计变革创新奠定基础。 展开更多
关键词 E-linac 数字化设计 管理系统 JSP SSH框架
下载PDF
Measurement of Electron Return Effect and Skin Dose Reduction by a Bolus in an Anthropomorphic Physical Phantom under a Magnetic Resonance Guided Linear Accelerator (MR-LINAC) System 被引量:1
20
作者 Eun Young Han Zhifei Wen +2 位作者 Hannah J. Lee Arnold dela Cruz Paulino Choonsik Lee 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2018年第3期339-346,共8页
Background: Magnetic resonance image-guided radiation therapy (MR-IGRT) promises more precise and effective radiation treatments compared to conventional IGRT by using real-time on-board MR imaging. Under the influenc... Background: Magnetic resonance image-guided radiation therapy (MR-IGRT) promises more precise and effective radiation treatments compared to conventional IGRT by using real-time on-board MR imaging. Under the influence of a magnetic field, however, secondary electrons exiting a surface can be forced in a circular path and re-enter the medium, resulting in dose increase at a beam-exit surface, called the electron return effect (ERE). The purpose of the study is to compare the exit skin dose computed by Monte Carlo dose calculation with measurements using an adult anthropomorphic phantom and to measure the effect of skin dose reduction by adding 1 cm-thick bolus. Method: The plan was compared with measurements using an adult anthropomorphic phantom combined with radiochromic films and thermoluminescent dosimeters. We also measured the skin dose reduction by adding 1 cm-thick bolus on the frontal surface of the phantom. Results: We found that 1 cm-thick bolus reduced the skin dose by up to 20% both in measurements and calculations. The plan was found to overestimate the measured skin dose by about 10% and there was no significant difference in the bolus effect between the breast skin and the skin (without breast attachment) doses. Conclusion: In conclusion, we confirmed the ERE effect on the anthropomorphic phantom under the magnetic field and the exit skin dose reduction by adding a bolus. Skin dose measurements using anthropomorphic phantom may be helpful to evaluate more realistic skin dose and the bolus effect in the magnetic field. 展开更多
关键词 MR-linac ELECTRON RETURN EFFECT Skin Dose
下载PDF
上一页 1 2 20 下一页 到第
使用帮助 返回顶部