Heat integration is important for energy-saving in the process industry.It is linked to the persistently challenging task of optimal design of heat exchanger networks(HEN).Due to the inherent highly nonconvex nonlinea...Heat integration is important for energy-saving in the process industry.It is linked to the persistently challenging task of optimal design of heat exchanger networks(HEN).Due to the inherent highly nonconvex nonlinear and combinatorial nature of the HEN problem,it is not easy to find solutions of high quality for large-scale problems.The reinforcement learning(RL)method,which learns strategies through ongoing exploration and exploitation,reveals advantages in such area.However,due to the complexity of the HEN design problem,the RL method for HEN should be dedicated and designed.A hybrid strategy combining RL with mathematical programming is proposed to take better advantage of both methods.An insightful state representation of the HEN structure as well as a customized reward function is introduced.A Q-learning algorithm is applied to update the HEN structure using theε-greedy strategy.Better results are obtained from three literature cases of different scales.展开更多
Shape and quantity of helical baffles have great impact on the shell-side performance of helical baffled heat exchangers (HBHE). In this work, three physical models of HBHE with baffles of different shape (trisecti...Shape and quantity of helical baffles have great impact on the shell-side performance of helical baffled heat exchangers (HBHE). In this work, three physical models of HBHE with baffles of different shape (trisection, quadrant and sextant sector) were investigated. Numerical simulations were performed on HBHE at three helix an- gles (10°, 25° and 40°) by the software ANSYS CFX. Analyses of numerical results indicate that the sextant HBHE shows relatively better fluid flow performance because the leakage flow in the triangle area is evidently reduced and the fluid streamline appears much closer to an ideal spiral flow, while the trisection and quadrant HBHE show more scattered and disordered streamline distributions. The convective heat transfer coefficient and pressure drop in three types of HBHE were presented. Further investigations on the shell side performance with different helical baf- fles were implemented by the field synergy theory. Both theoretical and numerical analyses gave support on the re- lations between helical baffle shape and shell-side performance. This paper may provide useful reference for the selection of baffle shade and auantitv in HBHE.展开更多
The heat exchanger network(HEN)in a syngas-to-methanol process was designed and optimized based on pinch technology under stable operating conditions to balance the energy consumption and economic gain.In actual indus...The heat exchanger network(HEN)in a syngas-to-methanol process was designed and optimized based on pinch technology under stable operating conditions to balance the energy consumption and economic gain.In actual industrial processes,fluctuations in production inevitably affect the stable operation of HENs.A flexibility analysis of the HEN was carried out to minimize such disturbances using the downstream paths method.The results show that two-third of the downstream paths cannot meet flexibility requirements,indicating that the HEN does not have enough flexibility to accommodate the disturbances in actual production.A flexible HEN was then designed with the method of dividing and subsequent merging of streams,which led to 13.89%and 20.82%reductions in energy consumption and total cost,respectively.Owing to the sufficient area margin and additional alternative heat exchangers,the flexible HEN was able to resist interference and maintain production stability and safety,with the total cost increasing by just 4.08%.展开更多
In this article, the performance and applications of a Spiral Plate Heat Exchanger are demonstrated. Also, governing equation of heat transfer phenomena in such heat exchangers is discussed. Regarding the governing eq...In this article, the performance and applications of a Spiral Plate Heat Exchanger are demonstrated. Also, governing equation of heat transfer phenomena in such heat exchangers is discussed. Regarding the governing equations, a LAB-sized model of this type of heat exchanger was designed and constructed. Galvanized Iron sheets were used as the heat transfer surfaces. Two Galvanized Iron sheets were rolled together around a central core and, as a result, two separated channels were made. Also, a predesign simulation of the heat exchanger was done using the Fluent software to predict the performance of the heat exchanger. First the geometry was made using Gambit software environment then the model was analyzed through Fluent. Because of less fouling, easier cleaning and high heat transfer coefficient, Spiral Heat Exchanger is a good alternative to the other types of heat exchangers, especially when it’s going to handle high fouling flows or highly viscous fluids. Low fouling rate of the heat exchanger, reduces the need of cleaning and therefore the out of service will be decreased. In the constructed heat exchanger, Nusselt number increases as the mass flow rate increases. Average Nusselt number is about 100 that is very good.展开更多
Heat exchangers are widely used in the process engineering such as the chemical industries, the petroleum industries, and the HVAC applications etc. An optimally designed heat exchanger cannot only help the optimizati...Heat exchangers are widely used in the process engineering such as the chemical industries, the petroleum industries, and the HVAC applications etc. An optimally designed heat exchanger cannot only help the optimization of the equipment size but also the reduction of the power consumption. In this paper, a new optimization approach called algorithms of changes (AOC) is proposed for design and optimization of the shell-tube heat exchanger. This new optimization technique is developed based on the concept of the book of changes (I Ching) which is one of the oldest Chinese classic texts. In AOC, the hexagram operations in I Ching are generalized to binary string case and an iterative process, which imitates the I Ching inference, is defined. Before applying the AOC to the heat exchanger design problem, the new optimization method is examined by the benchmark optimization problems such as the global optimization test functions and the travelling salesman problem (TSP). Based on the TSP results, the AOC is shown to be superior to the genetic algorithms (GA). The AOC is then used in the optimal design of heat exchanger. The shell inside diameter, tube outside diameter, and baffles spacing are treated as the design (or optimized) variables. The cost of the heat exchanger is arranged as the objective function. For the heat exchanger design problem, the results show that the AOC is comparable to the GA method. Both methods can find the optimal solution in a short period of time.展开更多
Separate type heat pipe heat exchangers are often used for large-scale heat exchanging. The arrangement of such a heat exchanger conveniently allows heat input to and output from the heat exchanger at remote locations...Separate type heat pipe heat exchangers are often used for large-scale heat exchanging. The arrangement of such a heat exchanger conveniently allows heat input to and output from the heat exchanger at remote locations. The traditional method of designing an ordinary HPHE (heat pipe heat exchanger) is commonly applied in the separate type exchanger design, but the calculations have to be carried out separately, which makes it very complicated. In this work, the ε-NTU (effectiveness-Number of Transfer Units) method was applied for optimization analysis of single- or multi-level separate type heat pipe heat exchangers. An optimizing formula for single-level separate type heat pipe heat exchangers was obtained. The optimizing principles of effec- tiveness-NTU and heat transfer rate by the equal distribution method for multi-level separate type heat pipe heat exchanger are presented. The design of separate type heat pipe heat exchangers by the optimizing method is more convenient and faster than by the traditional method.展开更多
The Sargent dividing wall column can implement four products separation sequences in one column based on Fully Thermally Coupled Distillation Column. The initial design parameters are required for the design optimizat...The Sargent dividing wall column can implement four products separation sequences in one column based on Fully Thermally Coupled Distillation Column. The initial design parameters are required for the design optimization or dynamic control of the Sargent dividing wall column, and in order to make the rigorous simulation of the Sargent dividing wall column more conducive to convergence, a ten column model for complex Sargent column is established in this paper,and the shortcut design method of this model is proposed. The internal minimum vapor and liquid flow are obtained by the Underwood equations and the mass balance method and the V-min method. The separation for a 4-component shortcut mixture of pentane, hexane, heptane and octane was considered, while the initial values of design parameters and the ratio of vapor-liquid distribution of each column were calculated by using the shortcut design method of a ten column model. And by comparing the shortcut calculations with rigorous simulation results, the practicality and reliability of shortcut calculations were verified. The reason for energy saving was analyzed based on back-mixing. A virtual heat exchanger is proposed to make the Sargent dividing wall column more energy efficient.展开更多
This Paper has first studied the simplified model of tubular heat exchanger which is widely used in the industry and other field.On the basis of reference 2,a new pole assignment design method of pro-cess control syst...This Paper has first studied the simplified model of tubular heat exchanger which is widely used in the industry and other field.On the basis of reference 2,a new pole assignment design method of pro-cess control system with derivative control action is found.For the above system,the method and the for-mation which calculate the feedback matrix K and gain matrix L is given,and the simulation of the system is made.展开更多
Flow characteristics in the entrance of plate-fin heat exchanger have been investigated by means of particle image velocimetry (PIV). The flow field was measured using the two-frame cross-correlation technique. Stream...Flow characteristics in the entrance of plate-fin heat exchanger have been investigated by means of particle image velocimetry (PIV). The flow field was measured using the two-frame cross-correlation technique. Streamline and velocity contour graphs at different cross-sections were obtained in the experiment. The experimental results indicate that flow maldistribution in the conventional header is very serious, while the improved header configuration with punched baffle can effectively improve the uniformity. The flow maldistribution parameter in plate-fin heat exchanger has been reduced from 1.21 to 0.21, and the ratio of the maximum velocity to the minimum is reduced from 23.2 to 1.8 by install-ing the punched baffle. The results suggest room for the optimum design of plate-fin heat exchanger.展开更多
Ground Source Heat Pump technique and its operating principle are described in this paper. Ground heat exchanger is the key technique of ground source heat pump and its patterns are discussed. Software is helpful to d...Ground Source Heat Pump technique and its operating principle are described in this paper. Ground heat exchanger is the key technique of ground source heat pump and its patterns are discussed. Software is helpful to design ground heat exchanger. A project of Chinese Ground Source Heat Pump is introduced and its market is more and more extensive.展开更多
基金The financial support provided by the Project of National Natural Science Foundation of China(U22A20415,21978256,22308314)“Pioneer”and“Leading Goose”Research&Development Program of Zhejiang(2022C01SA442617)。
文摘Heat integration is important for energy-saving in the process industry.It is linked to the persistently challenging task of optimal design of heat exchanger networks(HEN).Due to the inherent highly nonconvex nonlinear and combinatorial nature of the HEN problem,it is not easy to find solutions of high quality for large-scale problems.The reinforcement learning(RL)method,which learns strategies through ongoing exploration and exploitation,reveals advantages in such area.However,due to the complexity of the HEN design problem,the RL method for HEN should be dedicated and designed.A hybrid strategy combining RL with mathematical programming is proposed to take better advantage of both methods.An insightful state representation of the HEN structure as well as a customized reward function is introduced.A Q-learning algorithm is applied to update the HEN structure using theε-greedy strategy.Better results are obtained from three literature cases of different scales.
基金Supported by the National Natural Science Foundation of China(51106090)the National Key Basic Research Program of China(2013CB228305)the Independent Innovation Foundation of Shandong University(2012TS190)
文摘Shape and quantity of helical baffles have great impact on the shell-side performance of helical baffled heat exchangers (HBHE). In this work, three physical models of HBHE with baffles of different shape (trisection, quadrant and sextant sector) were investigated. Numerical simulations were performed on HBHE at three helix an- gles (10°, 25° and 40°) by the software ANSYS CFX. Analyses of numerical results indicate that the sextant HBHE shows relatively better fluid flow performance because the leakage flow in the triangle area is evidently reduced and the fluid streamline appears much closer to an ideal spiral flow, while the trisection and quadrant HBHE show more scattered and disordered streamline distributions. The convective heat transfer coefficient and pressure drop in three types of HBHE were presented. Further investigations on the shell side performance with different helical baf- fles were implemented by the field synergy theory. Both theoretical and numerical analyses gave support on the re- lations between helical baffle shape and shell-side performance. This paper may provide useful reference for the selection of baffle shade and auantitv in HBHE.
基金This work is financially supported by"the Fundamental Research Funds for the Central Universities"(2020XJHH01)the Yueqi Distinguished Scholar Project of China University of Mining and Technology(Beijing)(2020JCB02).
文摘The heat exchanger network(HEN)in a syngas-to-methanol process was designed and optimized based on pinch technology under stable operating conditions to balance the energy consumption and economic gain.In actual industrial processes,fluctuations in production inevitably affect the stable operation of HENs.A flexibility analysis of the HEN was carried out to minimize such disturbances using the downstream paths method.The results show that two-third of the downstream paths cannot meet flexibility requirements,indicating that the HEN does not have enough flexibility to accommodate the disturbances in actual production.A flexible HEN was then designed with the method of dividing and subsequent merging of streams,which led to 13.89%and 20.82%reductions in energy consumption and total cost,respectively.Owing to the sufficient area margin and additional alternative heat exchangers,the flexible HEN was able to resist interference and maintain production stability and safety,with the total cost increasing by just 4.08%.
文摘In this article, the performance and applications of a Spiral Plate Heat Exchanger are demonstrated. Also, governing equation of heat transfer phenomena in such heat exchangers is discussed. Regarding the governing equations, a LAB-sized model of this type of heat exchanger was designed and constructed. Galvanized Iron sheets were used as the heat transfer surfaces. Two Galvanized Iron sheets were rolled together around a central core and, as a result, two separated channels were made. Also, a predesign simulation of the heat exchanger was done using the Fluent software to predict the performance of the heat exchanger. First the geometry was made using Gambit software environment then the model was analyzed through Fluent. Because of less fouling, easier cleaning and high heat transfer coefficient, Spiral Heat Exchanger is a good alternative to the other types of heat exchangers, especially when it’s going to handle high fouling flows or highly viscous fluids. Low fouling rate of the heat exchanger, reduces the need of cleaning and therefore the out of service will be decreased. In the constructed heat exchanger, Nusselt number increases as the mass flow rate increases. Average Nusselt number is about 100 that is very good.
基金supported by Science and Technology Development Fund of Macao SAR (Grant No. 033/2008/A2)Research Grant of University of Macao, China (Grant No. RG081/09-10S/TSC/FST)
文摘Heat exchangers are widely used in the process engineering such as the chemical industries, the petroleum industries, and the HVAC applications etc. An optimally designed heat exchanger cannot only help the optimization of the equipment size but also the reduction of the power consumption. In this paper, a new optimization approach called algorithms of changes (AOC) is proposed for design and optimization of the shell-tube heat exchanger. This new optimization technique is developed based on the concept of the book of changes (I Ching) which is one of the oldest Chinese classic texts. In AOC, the hexagram operations in I Ching are generalized to binary string case and an iterative process, which imitates the I Ching inference, is defined. Before applying the AOC to the heat exchanger design problem, the new optimization method is examined by the benchmark optimization problems such as the global optimization test functions and the travelling salesman problem (TSP). Based on the TSP results, the AOC is shown to be superior to the genetic algorithms (GA). The AOC is then used in the optimal design of heat exchanger. The shell inside diameter, tube outside diameter, and baffles spacing are treated as the design (or optimized) variables. The cost of the heat exchanger is arranged as the objective function. For the heat exchanger design problem, the results show that the AOC is comparable to the GA method. Both methods can find the optimal solution in a short period of time.
文摘Separate type heat pipe heat exchangers are often used for large-scale heat exchanging. The arrangement of such a heat exchanger conveniently allows heat input to and output from the heat exchanger at remote locations. The traditional method of designing an ordinary HPHE (heat pipe heat exchanger) is commonly applied in the separate type exchanger design, but the calculations have to be carried out separately, which makes it very complicated. In this work, the ε-NTU (effectiveness-Number of Transfer Units) method was applied for optimization analysis of single- or multi-level separate type heat pipe heat exchangers. An optimizing formula for single-level separate type heat pipe heat exchangers was obtained. The optimizing principles of effec- tiveness-NTU and heat transfer rate by the equal distribution method for multi-level separate type heat pipe heat exchanger are presented. The design of separate type heat pipe heat exchangers by the optimizing method is more convenient and faster than by the traditional method.
基金supported by the High-level Talents Program of Hebei Province (A 2017002032)
文摘The Sargent dividing wall column can implement four products separation sequences in one column based on Fully Thermally Coupled Distillation Column. The initial design parameters are required for the design optimization or dynamic control of the Sargent dividing wall column, and in order to make the rigorous simulation of the Sargent dividing wall column more conducive to convergence, a ten column model for complex Sargent column is established in this paper,and the shortcut design method of this model is proposed. The internal minimum vapor and liquid flow are obtained by the Underwood equations and the mass balance method and the V-min method. The separation for a 4-component shortcut mixture of pentane, hexane, heptane and octane was considered, while the initial values of design parameters and the ratio of vapor-liquid distribution of each column were calculated by using the shortcut design method of a ten column model. And by comparing the shortcut calculations with rigorous simulation results, the practicality and reliability of shortcut calculations were verified. The reason for energy saving was analyzed based on back-mixing. A virtual heat exchanger is proposed to make the Sargent dividing wall column more energy efficient.
文摘This Paper has first studied the simplified model of tubular heat exchanger which is widely used in the industry and other field.On the basis of reference 2,a new pole assignment design method of pro-cess control system with derivative control action is found.For the above system,the method and the for-mation which calculate the feedback matrix K and gain matrix L is given,and the simulation of the system is made.
基金Supported by the Foundation for Excellent Doctoral Dissertation Author by Ministry of Education of China (No.199933).
文摘Flow characteristics in the entrance of plate-fin heat exchanger have been investigated by means of particle image velocimetry (PIV). The flow field was measured using the two-frame cross-correlation technique. Streamline and velocity contour graphs at different cross-sections were obtained in the experiment. The experimental results indicate that flow maldistribution in the conventional header is very serious, while the improved header configuration with punched baffle can effectively improve the uniformity. The flow maldistribution parameter in plate-fin heat exchanger has been reduced from 1.21 to 0.21, and the ratio of the maximum velocity to the minimum is reduced from 23.2 to 1.8 by install-ing the punched baffle. The results suggest room for the optimum design of plate-fin heat exchanger.
文摘Ground Source Heat Pump technique and its operating principle are described in this paper. Ground heat exchanger is the key technique of ground source heat pump and its patterns are discussed. Software is helpful to design ground heat exchanger. A project of Chinese Ground Source Heat Pump is introduced and its market is more and more extensive.