BACKGROUND With the development of percutaneous coronary intervention(PCI),the number of interventional procedures without implantation,such as bioresorbable stents(BRS)and drug-coated balloons,has increased annually....BACKGROUND With the development of percutaneous coronary intervention(PCI),the number of interventional procedures without implantation,such as bioresorbable stents(BRS)and drug-coated balloons,has increased annually.Metal drug-eluting stent unloading is one of the most common clinical complications.Comparatively,BRS detachment is more concealed and harmful,but has yet to be reported in clinical research.In this study,we report a case of BRS unloading and successful rescue.This is a case of a 59-year-old male with the following medical history:“Type 2 diabetes mellitus”for 2 years,maintained with metformin extended-release tablets,1 g PO BID;“hypertension”for 20 years,with long-term use of metoprolol sustained-release tablets,47.5 mg PO QD;“hyperlipidemia”for 20 years,without regular medication.He was admitted to the emergency department of our hospital due to intermittent chest pain lasting 18 hours,on February 20,2022 at 15:35.Electrocardiogram results showed sinus rhythm,ST-segment elevation in leads I and avL,and poor R-wave progression in leads V1–3.High-sensitivity troponin I level was 4.59 ng/mL,indicating an acute high lateral wall myocardial infarction.The patient’s family requested treatment with BRS,without implanta-tion.During PCI,the BRS became unloaded but was successfully rescued.The patient was followed up for 2 years;he had no episodes of angina pectoris and was in generally good condition.CONCLUSION We describe a case of a 59-year-old male experienced BRS unloading and successful rescue.By analyzing images,the causes of BRS unloading and the treatment plan are discussed to provide insights for BRS release operations.We discuss preventive measures for BRS unloading.展开更多
Objective:Double-J(DJ)ureteric stents are commonly placed perioperatively for semirigid or flexible ureteroscopic renal surgery.It is believed that lesser stent material within the bladder mitigates stent-related symp...Objective:Double-J(DJ)ureteric stents are commonly placed perioperatively for semirigid or flexible ureteroscopic renal surgery.It is believed that lesser stent material within the bladder mitigates stent-related symptoms.This study aimed to evaluate the J-Fil ureteral stent,a single pigtail suture stent compared with conventional DJ stent in relation to stent symptoms in an Asian population undergoing ureterorenal intervention.Methods:Based on internal audit committee recommendation approval,the records of 50 patients retrieved,available data of 41 patients who were prospectively enrolled into two groups(Group 1[J-Fil stent group],n=21 and Group 2[DJ stent group],n=20)between August 2020 to January 2021,were analysed.Parameters compared were nature of procedure,stone location and size,ease of deployment or removal,and complications.A modified universal stent symptom questionnaire was used to assess morbidity of stent symptoms within 48 h of insertion and at removal.Results:Both groups had similar median age,distribution in male to female ratio,and stone size.The overall median universal stent symptom questionnaire score at insertion was similar for bladder pain,flank or loin pain,and quality of life between Group 1 and 2;however,at removal Group 1 fared significantly better than Group 2,especially for flank or loin pain and pain at voiding.Both groups had similar ease in insertion with no hospital readmissions.Conclusion:Our audit favoured the single pigtail suture stent in Asian ureters in mitigating stent-related issues.It showed a good safety profile with easy deployment and removal.It promises a new standard in stenting.展开更多
Objective:Ureteral stents are customarily inserted to facilitate urinary drainage,but they come with their own glitches of being forgotten and/or encrusted leading to serious consequences.The present study aimed to re...Objective:Ureteral stents are customarily inserted to facilitate urinary drainage,but they come with their own glitches of being forgotten and/or encrusted leading to serious consequences.The present study aimed to report the complications in patients with forgotten and encrusted stents according to the Clavien-Dindo system specific to urological procedures and identify the factors leading to high-grade(Clavien-Dindo Grade 4A or above)complications.Methods:The hospital records of patients with forgotten encrusted double-J stents over a period of 8 years were reviewed.The parameters recorded included patient demographics,indwelling time,need for percutaneous nephrostomy,hemodialysis,urine culture,blood culture,total blood counts,serum creatinine,radiologic findings,management techniques,number of surgical interventions,modified Clavien-Dindo complications,follow-up,and mortality,if any.Results:Forty patients were included in the study.The median age was 52(range 6-85)years.Of the total,25(62.5%)patients had a“significant”stent load;31(77.5%)had renal failure or acute kidney injury on presentation;19(47.5%)patients had sepsis at presentation.Among the patients presented with sepsis,11(57.9%)patients demonstrated a positive urine culture;and 7/11(63.6%)patients exhibited pan-resistant organisms.Twelve out of 40(30.0%)patients in our series developed high-grade Clavien-Dindo complications.On univariate analysis,sepsis at presentation(p=0.007),stent load(p=0.031),diabetes(p=0.023),positive urine culture(p=0.007),and stent indwelling time of more than 1 year(p=0.031)were found to be significant.On multivariate logistic regression analysis,sepsis at presentation(p=0.017)and positive urine culture(p=0.016)were significant predictors for high-grade complications.Conclusion:It is prudent to identify specific risk factors,namely sepsis at presentation and positive urine culture to triage and optimize these patients before surgical management.展开更多
Patients with malignant biliary obstruction,following endoscopic retrograde cholangiopancreatography(ERCP)failure could be referred for endoscopicultrasound-guided biliary drainage through electrocautery-enhanced(ECE)...Patients with malignant biliary obstruction,following endoscopic retrograde cholangiopancreatography(ERCP)failure could be referred for endoscopicultrasound-guided biliary drainage through electrocautery-enhanced(ECE)lumen-apposing metal stent(LAMS)placement.However,the efficacy and safety of ECE-LAMS in this scenario have remained debatable due to minimal scientific evidence.The current confirmed 91.0%clinical success,96.7%technical success,7.3%reintervention rate,and 17.5%adverse events,following the treatment of malignant biliary obstruction with ECE-LAMS delivery.Finally,ECE-LAMS proved to be a generalizable strategy for managing biliary obstruction for patients who were excluded from ERCP.展开更多
Background: Implementing invasive procedures is an important part of patient management by clinical nurses;however, there are gaps between nurses’ actual knowledge and skills and expected professional care capacity. ...Background: Implementing invasive procedures is an important part of patient management by clinical nurses;however, there are gaps between nurses’ actual knowledge and skills and expected professional care capacity. Purpose: This scoping review aimed to map the existing literature related to recent institution-provided educational programs for invasive procedures involving clinical nurses. This study seeks to understand the contents of educational programs and the methods for assessing educational effects. Methods: This scoping review was completed using the following four databases: PubMed (MEDLINE), Embase, Cochrane Library, and Emcare for the period 2000-2022. We included studies that used all forms of educational approaches (e.g., didactic lectures, hands-on training, or on-the-job training). This scoping review considered peer-reviewed publications published in English using quantitative, qualitative, or mixed approaches. A total of 83 studies underwent in the final analysis. Results and Conclusion: A combination of didactic lectures and hands-on training was provided as an educational program in most studies. Contrary to our prediction, educational interventions with advanced technologies such as VR are extremely rare, suggesting that the effectiveness of advanced technologies in learning invasive procedures should be examined to facilitate and retain educational effects more efficiently in future studies. Regarding the assessment of educational effects, nurses’ cognitive (i.e., theoretical knowledge about procedures), psychomotor (i.e., implementing procedures), and psychological aspects (e.g., confidence and self-efficacy in procedures) were evaluated using questionnaires and observational methods. While most studies used a one-group pretest-posttest design, the ratio of randomized controlled trials (RCT) was relatively low. Thus, an RCT design should be introduced in future studies to test the validity of the developed educational program more accurately.展开更多
Background: Prenatal diagnosis is the process of evaluating the presence of disease or potential disease in the fetus, this enables families to be better prepared before the birth of the baby. There are non-invasive p...Background: Prenatal diagnosis is the process of evaluating the presence of disease or potential disease in the fetus, this enables families to be better prepared before the birth of the baby. There are non-invasive prenatal diagnosis procedures and invasive prenatal diagnosis procedures. The invasive prenatal diagnosis procedures are CVS (chorionic villus sampling) and amniocentesis. The American College of Obstetricians and Gynecologists states that invasive diagnostic testing should be available to all women, regardless of age or risk. Objective: To determine the indications, outcome and results of diagnostic invasive prenatal procedures. Study setting: The obstetrics and Gynecology Department in Salmaniya Medical Complex in Kingdom of Bahrain. Study design: Retrospective descriptive study. Study subjects and Methods: This retrospective descriptive study was conducted on 175 pregnant women who underwent invasive prenatal procedures (CVS and amniocentesis) between January 2013 and December 2018 at SMC in Kingdom of Bahrain. All medical records of the participants were reviewed and entered the study. According to the implemented procedures, medical records were categorized into two chorionic villus sampling (CVS) and amniocentesis groups. The study subject will include indications of the procedures which are advanced maternal age, hematological disorders, genetic disorders, metabolic disorders, abnormal structural findings in fetal ultrasound and previous child with aneuploidy. In addition, the study will address the complications, outcome and results of procedures. Results: About half of our indications of the procedures were due to hematological disorders (47.6%) followed by abnormal structural findings in fetal ultrasound (30.1%) then genetic disorders (15.7%), metabolic disorders (4.8%) and advanced maternal age (1.8%). Regarding complications of the procedure;threatened miscarriage or loss of pregnancy within 3 weeks was (2.3%), amniotic fluid leakage (0.7%), abdominal cramps (0.7%) and Insufficient or contaminated sample (6.2%). Regarding outcome of the pregnancy, our results showed that the loss of pregnancy was (4.8%), intrauterine fetal death or still birth was (13.9%), live birth was (63.9%), preterm delivery was (7.8%), preterm premature rupture of membrane (PPROM) was (1.8%), limbs reduction was (0.0%). Termination of pregnancy outside the country was (7.8%) of chorionic villus sampling and amniocentesis. Conclusion: CVS and amniocentesis are useful outpatient procedures to detect diagnosis or to assess whether a patient is at increased risk of having an affected fetus and that will minimize the psychological impact on the patient and to provide a proper antenatal care to the pregnant women by her obstetrician and follow up to the baby by pediatrician. In this study it was observed that most of the patients who underwent the procedure were couples either carrier or affected to sickle cell disease or Beta thalassemia.展开更多
The role of endoscopy in pathologies of the bile duct and gallbladder has seen notable advancements over the past two decades.With advancements in stent technology,such as the development of lumen-apposing metal stent...The role of endoscopy in pathologies of the bile duct and gallbladder has seen notable advancements over the past two decades.With advancements in stent technology,such as the development of lumen-apposing metal stents,and adoption of endoscopic ultrasound and electrosurgical principles in therapeutic endoscopy,what was once considered endoscopic failure has transformed into failure of an approach that could be salvaged by a second-or third-line endoscopic strategy.Incorporation of these advancements in routine patient care will require formal training and multidisciplinary acceptance of established techniques and collaboration for advancement of experimental techniques to generate robust evidence that can be utilized to serve patients to the best of our ability.展开更多
BACKGROUND In severe cases of coronary artery disease,percutaneous coronary intervention provide promising results.The stent used could be a drug-eluting stent(DES)or a titanium-nitride-oxide coated stent(TiNOS).AIM T...BACKGROUND In severe cases of coronary artery disease,percutaneous coronary intervention provide promising results.The stent used could be a drug-eluting stent(DES)or a titanium-nitride-oxide coated stent(TiNOS).AIM To compare the 5-year effectiveness and safety of the two stent types.METHODS The following systematic review and meta-analysis was conducted in accordance with the preferred reporting items for systematic reviews and meta-analysis guidelines,and PubMed/MEDLINE,Scopus,and Cochrane Central were searched from inception till August 2023.Primary outcomes were major adverse cardiac events(MACE),cardiac death,myocardial infarction(MI),cardiac death or MI,and ischemia-driven total lesion revascularization(ID-TLR).RESULTS Four randomized controlled trials(RCT),which analyzed a sum total of 3045 patients with acute coronary syndrome(ACS)after a median follow-up time of 5 years were included.Though statistically insignificant,an increase in the ID-TLR was observed in patients receiving TiNOSs vs DESs.In addition,MI,cardiac death and MI,and definite stent thrombosis(DST)were significantly decreased in the TiNOS arm.Baseline analysis revealed no significant results with meta-regression presenting non-ST elevated MI(NSTEMI)as a statistically significant covariate in the outcome of MACE.CONCLUSION TiNOS was found to be superior to DES in terms of MI,cardiac death or MI,and DST outcomes,however,the effect of the two stent types on ID-TLR and MACE was not significant.A greater number of studies are required to establish an accurate comparison of patient outcomes in TiNOS and DES.展开更多
BACKGROUNDAlmost all cases of cervical cancer can be attributed to human papillomavirus(HPV) infection. The loop electrosurgical excision procedure (LEEP) is widelyused to treat HPV-mediated disease;thus, cervical can...BACKGROUNDAlmost all cases of cervical cancer can be attributed to human papillomavirus(HPV) infection. The loop electrosurgical excision procedure (LEEP) is widelyused to treat HPV-mediated disease;thus, cervical cancer is highly preventable.However, LEEP does not necessarily clear HPV rapidly and may affect theaccuracy of the results of ThinPrep cytology test (TCT) and cervical biopsy due tothe formation of cervical scars.CASE SUMMARYA 40-year-old woman underwent LEEP for cervical intraepithelial neoplasia grade1 approximately 10 years ago. Subsequent standard cervical cancer screeningsuggested persistent HPV-52 infection, but TCT results were negative. Cervicalbiopsy under colposcopy was performed thrice over a 10-year period, yieldingnegative pathology results. She developed abnormal vaginal bleeding after sexualactivity, persisting for approximately 1 year, and underwent hysteroscopy in ourhospital. Histopathologic evaluation confirmed adenocarcinoma in situ of theuterine cervix.CONCLUSIONPatients with long-term persistent, high-risk HPV infection and negative pathologyresults of cervical biopsy after LEEP are at risk of cervical cancer. Hysteroscopicresection of cervical canal tissue is recommended as a supplement tocervical biopsy because it helps define the lesion site and may yield a pathologicdiagnosis.展开更多
This paper primarily concerns the effective coordination of the procedures and methods employed in open pit mining operations under the background of river management.The central objective of this study is to identify...This paper primarily concerns the effective coordination of the procedures and methods employed in open pit mining operations under the background of river management.The central objective of this study is to identify a viable approach for ensuring rational and efficient development of open pit mineral resources while simultaneously protecting and restoring the ecological environment of the river.This approach should facilitate the realization of a harmonious symbiosis between mining and river management.The intricate mutual influence relationship between river management and open pit mining is first analyzed in depth,which provides a solid foundation for the subsequent coordination strategy development.In light of the aforementioned considerations,a set of coordination procedures for open pit mining based on river management conditions is proposed.These procedures emphasize the integration of river protection into the overall layout of mining at the planning stage.The implementation of scientific mining schemes,accompanied by rigorous control of the scope and depth of mining operations,has proven to be an effective means of reducing the impact of mining activities on river environments.This approach has also facilitated the achievement of a balance and coordination between mining and river management.展开更多
This editorial delves into Peng et al's article,published in the World Journal of Gastrointestinal Surgery.Peng et al's meta-analysis investigates the effectiveness of electrocautery-enhanced lumen-apposing me...This editorial delves into Peng et al's article,published in the World Journal of Gastrointestinal Surgery.Peng et al's meta-analysis investigates the effectiveness of electrocautery-enhanced lumen-apposing metal stents(ECE-LAMS)in ultrasound-guided biliary drainage for alleviating malignant biliary obstruction.Examining 14 studies encompassing 620 participants,the research underscores a robust technical success rate of 96.7%,highlighting the efficacy of ECE-LAMS,particularly in challenging cases which have failed endoscopic retrograde cholangio pancreatography.A clinical success rate of 91.0% underscores its impact on symptom alleviation,while a reasonably tolerable adverse event rate of 17.5% is observed.However,the 7.3% re-intervention rate stresses the need for post-procedural monitoring.Subgroup analyses validate consistent outcomes,bolstering the applicability of ECE-LAMS.These findings advocate for the adoption of ECELAMS as an appropriate approach for biliary palliation,urging further exploration in real-world clinical contexts.They offer valuable insights for optimizing interventions targeting malignant biliary obstruction management.展开更多
In this editorial,we comment on the article by Peng et al.Palliative drainage for biliary obstruction resulting from unresectable malignant lesions includes internal and external drainage.The procedures of biliary dra...In this editorial,we comment on the article by Peng et al.Palliative drainage for biliary obstruction resulting from unresectable malignant lesions includes internal and external drainage.The procedures of biliary drainage are usually guided by fluoroscopy or transcutaneous ultrasound,endoscopic ultrasound(EUS),or both.Endoscopic retrograde cholangiopancreatography(ERCP)has been primarily recommended for the management of biliary obstruction,while EUS-guided biliary drainage and percutaneous transhepatic biliary drainage(PTBD)are alternative choices for cases where ERCP has failed or is impossible.PTBD is limited by shortcomings of a higher rate of adverse events,more reinterventions,and severe complications.EUS-guided biliary drainage has a lower rate of adverse events than PTBD.EUS-guided biliary drainage with electrocautery-enhanced lumen-apposing metal stent(ECE-LAMS)enables EUS-guided biliaryenteric anastomosis to be performed in a single step and does not require prior bile duct puncture or a guidewire.The present meta-analysis showed that ECELAMS has a high efficacy and safety in relieving biliary obstruction in general,although the results of LAMS depending on the site of biliary obstruction.This study has highlighted the latest advances with a larger sample-based comprehensive analysis.展开更多
BACKGROUND Endoscopic management is the first-line therapy for post-liver-transplant anas-tomotic strictures.Although the optimal duration of treatment with plastic stents has been reported to be 8-12 months,data on s...BACKGROUND Endoscopic management is the first-line therapy for post-liver-transplant anas-tomotic strictures.Although the optimal duration of treatment with plastic stents has been reported to be 8-12 months,data on safety and duration for metal stents in this setting is scarce.Due to limited access to endoscopic retrograde cholan-giopancreatography(ERCP)during the coronavirus disease 2019 pandemic in our centre,there was a change in practice towards increased usage and length-of-stay of the Kaffes biliary intraductal self-expanding stent in patients with suitable anatomy.This was mainly due to the theoretical benefit of Kaffes stents allowing for longer indwelling periods compared to the traditional plastic stents.METHODS Adult liver transplant recipients aged 18 years and above who underwent ERCP were retrospectively identified during a 10-year period through a database query.Unplanned admissions post-Kaffes stent insertion were identified manually through electronic and scanned medical records.The main outcome was the incidence of complications when stents were left indwelling for 3 months vs 6 months.Stent efficacy was calculated via rates of stricture recurrence between patients that had stenting courses for≤120 d or>120 d.RESULTS During the study period,a total of 66 ERCPs with Kaffes insertion were performed in 54 patients throughout their stenting course.In 33 ERCPs,the stent was removed or exchanged on a 3-month interval.No pancreatitis,perfor-ations or deaths occurred.Minor post-ERCP complications were similar between the 3-month(abdominal pain and intraductal migration)and 6-month(abdominal pain,septic shower and embedded stent)groups-6.1%vs 9.1%respectively,P=0.40.All strictures resolved at the end of the stenting course,but the stenting course was variable from 3 to 22 months.The recurrence rate for stenting courses lasting for up to 120 d was 71.4%and 21.4%for stenting courses of 121 d or over(P=0.03).There were 28 patients that were treated with a single ERCP with Kaffes,21 with removal after 120 d and 7 within 120 d.There was a significant improvement in stricture recurrence when the Kaffes was removed after 120 d when a single ERCP was used for the entire stenting course(71.0%vs 10.0%,P=0.01).CONCLUSION Utilising a single Kaffes intraductal fully-covered metal stent for at least 4 months is safe and efficacious for the management of post-transplant anastomotic strictures.展开更多
Objective To study the impact of the first national centralized procurement of coronary stents on patients’psychology,the economy of medical institutions,and the survival and development of the coronary stents indust...Objective To study the impact of the first national centralized procurement of coronary stents on patients’psychology,the economy of medical institutions,and the survival and development of the coronary stents industry,and to provide suggestions on perfecting procedures to better carry out the centralized procurement of coronary stents.Methods Literature analysis was used to investigate the results of the procurement of coronary stent in a province and a hospital.Results and Conclusion The centralized procurement of coronary stents has alleviated the economic pressure of patients,but it has many problems.Therefore,this paper proposes some suggestions,such as promoting the orderly development of the coronary stent industry,improving the evaluation link of the centralized procurement of coronary stents,adopting the accurate reporting model to ensure the quality of coronary stents and improving the standardization of clinical services.展开更多
Objective To identify factors affecting the efficacy of steroid-eluting sinus stents implanted after endoscopic sinus surgery(ESS)in patients with chronic rhinosinusitis with nasal polyps(CRSwNP).Methods We performed ...Objective To identify factors affecting the efficacy of steroid-eluting sinus stents implanted after endoscopic sinus surgery(ESS)in patients with chronic rhinosinusitis with nasal polyps(CRSwNP).Methods We performed a post-hoc analysis of a randomized self-controlled clinical trial on post-operative implantation of bioabsorbable steroid-eluting stents in patients with CRSwNP.Univariate logistic regression analysis was conducted to identify which of the following factors affect the response to post-operative stent implantation:sex,serum eosinophil levels,history of prior surgery,endoscopic scores,and comorbid conditions(asthma and allergic rhinitis).The primary outcome was the rate of post-operative intervention on day 30,and the secondary outcome was the rate of polypoid tissue formation(grades 2–3)on days 14,30,and 90.Results A total of 151 patients with CRSwNP were included in the post-hoc analysis.Asthma was identified as the only risk factor for a poor response to steroid-eluting sinus stents on post-operative day 30,with an odds ratio of 23.71(95%CI,2.81,200.16;P=0.004)for the need for post-operative intervention and 19(95%CI,2.20,164.16;P=0.003)for moderate-to-severe polypoid tissue formation.In addition,the asthmatic group showed higher rates of post-operative intervention and polypoid tissue formation than the non-asthmatic group on post-operative day 30.Blood eosinophil levels were not identified as a risk factor for poor outcomes after stent implantation.Conclusion Comorbid asthma,but not blood eosinophil level,impairs the efficacy of steroid-eluting sinus stents in the short term after ESS in patients with CRSwNP.展开更多
There is still significant debate regarding the best surgical treatment for malignant left-sided large bowel obstruction.Primary resection and anastomosis offers the advantages of a definite procedure without need for...There is still significant debate regarding the best surgical treatment for malignant left-sided large bowel obstruction.Primary resection and anastomosis offers the advantages of a definite procedure without need for further surgery.Its main disadvantages are related to the increased technical challenge and to the potential higher risk of anastomotic leakage that occurs in the emergency setting.Primary resection with end colostomy(Hartmann's procedure) is considered the safer option.Tan et al compared in a systematic review and meta-analysis the use of self-expanding metallic stents(SEMS) as a bridge to surgery vs emergency surgery in the management of acute malignant left-sided large bowel obstruction.The authors concluded that the technical and clinical success rates for stenting were lower than expected.SEMS was associated with a high incidence of clinical and silent perforation.Stenting instead of loop colostomy can be recommended only if the appropriate expertise is available in the hospital.The goal of stenting,a decrease of the stoma rate,may be advocated only if the complication rates of stenting are lower than those of stoma creation in the emergency situation.Until now,this was not demonstrated in a prospective randomized trial.展开更多
Colonic stenting has had a significant positive impact on the management of obstructive left-sided colon cancer(OLCC) in terms of both palliative treatment and bridge-to-surgery(BTS). Notably, many studies have convin...Colonic stenting has had a significant positive impact on the management of obstructive left-sided colon cancer(OLCC) in terms of both palliative treatment and bridge-to-surgery(BTS). Notably, many studies have convincingly demonstrated the effectiveness of stenting as a BTS, resulting in improvements in shortterm outcomes and quality of life, safety, and efficacy in subsequent curative surgery, and increased cost-effectiveness, whereas the safety of chemotherapy after stenting and the long-term outcomes of stenting as a BTS are controversial. Several studies have suggested an increased risk of perforation in patients receiving bevacizumab chemotherapy after colonic stenting. In addition, several pathological analyses have suggested a negative oncological impact of colonic stenting. In contrast, many recent studies have demonstrated that colonic stenting for OLCC does not negatively impact the safety of chemotherapy or long-term oncological outcomes. The updated version of the European Society of Gastrointestinal Endoscopy guidelines released in 2020 included colonic stenting as a BTS for OLCC as a recommended treatment. It should be noted that the experience of endoscopists is involved in determining technical and clinical success rates and possibly oncological outcomes. This review discusses the positive and negative impacts of colonic stenting on OLCC treatment, particularly in terms of oncology.展开更多
BACKGROUND Endoscopic ultrasound-guided biliary drainage using electrocautery-enhanced(ECE)delivery of lumen-apposing metal stent(LAMS)is gradually being re-cognized as a viable palliative technique for malignant bili...BACKGROUND Endoscopic ultrasound-guided biliary drainage using electrocautery-enhanced(ECE)delivery of lumen-apposing metal stent(LAMS)is gradually being re-cognized as a viable palliative technique for malignant biliary obstruction after endoscopic retrograde cholangiopancreatography(ERCP)failure.However,most of the studies that have assessed its efficacy and safety were small and hetero-geneous.Prior meta-analyses of six or fewer studies that were published 2 years ago were therefore underpowered to yield convincing evidence.AIM To update the efficacy and safety of ECE-LAMS for treatment of biliary ob-struction after ERCP failure.METHODS We searched PubMed,EMBASE,and Scopus databases from the inception of the ECE technique to May 13,2022.Primary outcome measure was pooled technical success rate,and secondary outcomes were pooled rates of clinical success,re-intervention,and adverse events.Meta-analysis was performed using a random-effects model following Freeman-Tukey double-arcsine transformation in R soft-ware(version 4.1.3).RESULTS Fourteen eligible studies involving 620 participants were ultimately included.The pooled rate of technical success was 96.7%,and clinical success was 91.0%.Adverse events were reported in 17.5%of patients.Overall reinter-vention rate was 7.3%.Subgroup analyses showed results were generally consistent.CONCLUSION ECE-LAMS has favorable success with acceptable adverse events in relieving biliary obstruction when ERCP is impossible.The consistency of results across most subgroups suggested that this is a generalizable approach.展开更多
BACKGROUND Endoscopic placement of a self-expandable metal stent(SEMS)is a minimally invasive treatment for use in malignant and benign colonic obstruction.However,their widespread use is still limited with a nationwi...BACKGROUND Endoscopic placement of a self-expandable metal stent(SEMS)is a minimally invasive treatment for use in malignant and benign colonic obstruction.However,their widespread use is still limited with a nationwide analysis showing only 5.4%of patients with colon obstruction undergoing stent placement.This underutilization could be due to perceived increase risk of complications with stent placement.AIM To review long-and short-term clinical success of SEMS use for colonic obstruction at our center.METHODS We retrospectively reviewed all the patients who underwent colonic SEMS placement over aeighteen year period (August 2004 through August 2022) at our academic center. Demographicsincluding age, gender, indication (malignant and benign), technical success, clinical success,complications (perforation, stent migration), mortality, and outcomes were recorded.RESULTSSixty three patients underwent colon SEMS over an 18-year period. Fifty-five cases were formalignant indications, 8 were for benign conditions. The benign strictures included diverticulardisease stricturing (n = 4), fistula closure (n = 2), extrinsic fibroid compression (n = 1), and ischemicstricture (n = 1). Forty-three of the malignant cases were due to intrinsic obstruction from primaryor recurrent colon cancer;12 were from extrinsic compression. Fifty-four strictures occurred on theleft side, 3 occurred on the right and the rest in transverse colon. The total malignant case (n = 55)procedural success rate was 95% vs 100% for benign cases (P = 1.0, NS). Overall complication ratewas significantly higher for benign group: Four complications were observed in the malignantgroup (stent migration, restenosis) vs 2 of 8 (25%) for benign obstruction (1-perforation, 1-stentmigration) (P = 0.02). When stratifying complications of perforation and stent migration there wasno significant difference between the two groups (P = 0.14, NS).CONCLUSIONColon SEMS remains a worthwhile option for colonic obstruction related to malignancy and has ahigh procedural and clinical success rate. Benign indications for SEMS placement appear to havesimilar success to malignant. While there appears to be a higher overall complication rate inbenign cases, our study is limited by sample size. When evaluating for perforation alone theredoes not appear to be any significant difference between the two groups. SEMS placement may bea practical option for indications other that malignant obstruction. Interventional endoscopistsshould be aware and discuss the risk for complications in setting of benign conditions. Indicationsin these cases should be discussed in a multi-disciplinary fashion with colorectal surgery.展开更多
BACKGROUND Mechanical thrombectomy is the most effective treatment for great cerebral artery embolization within a set time window.Typically,an arteriogram does not show the localization of the stent after release and...BACKGROUND Mechanical thrombectomy is the most effective treatment for great cerebral artery embolization within a set time window.Typically,an arteriogram does not show the localization of the stent after release and whether a thrombus is captured or not.Thus,improving the visualization of a stent in interventional therapy will be helpful for clinicians.AIM To analyze stent imaging findings to enhance clinicians’understanding of a special circumstance,wherein a Solitaire AB retrievable stent was visible during the imaging of a thrombus capture that improved the success rate of stent-based mechanical thrombectomy.METHODS This was a retrospective study with four acute ischemic stroke(AIS)patients who underwent stent-based mechanical thrombectomy.RESULTS Patient 1 was a 64-year-old man admitted after 5 h of confusion;angiography revealed basilar artery occlusion.We inserted a stent into the left posterior cerebral artery-P2 segment and visualized the expanded stent that successfully captured a thrombus.Patient 2 was a 74-year-old man admitted with confusion,which lasted approximately 3 h.Angiography revealed a left middle cerebral artery(MCA)-M1 segment occlusion.A stent was deployed in the distal M2 segment,and we could visualize the stent by capturing the thrombus.Patient 3 was a 74-year-old woman admitted after experiencing left hemiplegia for 3 h.We deployed a stent at the distal right MCAM2 segment,and the developing stent captured a large thrombus.Patient 4 was an 82-year-old man who presented with confusion for 3 h.A developing stent was placed in the distal left MCA-M1 segment,which captured a large thrombus and several fragmented thrombi.CONCLUSION To the best of our knowledge,this is the first report of stent imaging in patients with AIS.We demonstrated the usefulness and substantial potential of stent imaging in stent-based mechanical thrombectomy for AIS.展开更多
基金Supported by Health Commission of Hunan Province,No.202203014389Chinese Medicine Research Project of Hunan Province,No.A2023051the Natural Science Foundation of Hunan Province,No.2024JJ9414.
文摘BACKGROUND With the development of percutaneous coronary intervention(PCI),the number of interventional procedures without implantation,such as bioresorbable stents(BRS)and drug-coated balloons,has increased annually.Metal drug-eluting stent unloading is one of the most common clinical complications.Comparatively,BRS detachment is more concealed and harmful,but has yet to be reported in clinical research.In this study,we report a case of BRS unloading and successful rescue.This is a case of a 59-year-old male with the following medical history:“Type 2 diabetes mellitus”for 2 years,maintained with metformin extended-release tablets,1 g PO BID;“hypertension”for 20 years,with long-term use of metoprolol sustained-release tablets,47.5 mg PO QD;“hyperlipidemia”for 20 years,without regular medication.He was admitted to the emergency department of our hospital due to intermittent chest pain lasting 18 hours,on February 20,2022 at 15:35.Electrocardiogram results showed sinus rhythm,ST-segment elevation in leads I and avL,and poor R-wave progression in leads V1–3.High-sensitivity troponin I level was 4.59 ng/mL,indicating an acute high lateral wall myocardial infarction.The patient’s family requested treatment with BRS,without implanta-tion.During PCI,the BRS became unloaded but was successfully rescued.The patient was followed up for 2 years;he had no episodes of angina pectoris and was in generally good condition.CONCLUSION We describe a case of a 59-year-old male experienced BRS unloading and successful rescue.By analyzing images,the causes of BRS unloading and the treatment plan are discussed to provide insights for BRS release operations.We discuss preventive measures for BRS unloading.
文摘Objective:Double-J(DJ)ureteric stents are commonly placed perioperatively for semirigid or flexible ureteroscopic renal surgery.It is believed that lesser stent material within the bladder mitigates stent-related symptoms.This study aimed to evaluate the J-Fil ureteral stent,a single pigtail suture stent compared with conventional DJ stent in relation to stent symptoms in an Asian population undergoing ureterorenal intervention.Methods:Based on internal audit committee recommendation approval,the records of 50 patients retrieved,available data of 41 patients who were prospectively enrolled into two groups(Group 1[J-Fil stent group],n=21 and Group 2[DJ stent group],n=20)between August 2020 to January 2021,were analysed.Parameters compared were nature of procedure,stone location and size,ease of deployment or removal,and complications.A modified universal stent symptom questionnaire was used to assess morbidity of stent symptoms within 48 h of insertion and at removal.Results:Both groups had similar median age,distribution in male to female ratio,and stone size.The overall median universal stent symptom questionnaire score at insertion was similar for bladder pain,flank or loin pain,and quality of life between Group 1 and 2;however,at removal Group 1 fared significantly better than Group 2,especially for flank or loin pain and pain at voiding.Both groups had similar ease in insertion with no hospital readmissions.Conclusion:Our audit favoured the single pigtail suture stent in Asian ureters in mitigating stent-related issues.It showed a good safety profile with easy deployment and removal.It promises a new standard in stenting.
文摘Objective:Ureteral stents are customarily inserted to facilitate urinary drainage,but they come with their own glitches of being forgotten and/or encrusted leading to serious consequences.The present study aimed to report the complications in patients with forgotten and encrusted stents according to the Clavien-Dindo system specific to urological procedures and identify the factors leading to high-grade(Clavien-Dindo Grade 4A or above)complications.Methods:The hospital records of patients with forgotten encrusted double-J stents over a period of 8 years were reviewed.The parameters recorded included patient demographics,indwelling time,need for percutaneous nephrostomy,hemodialysis,urine culture,blood culture,total blood counts,serum creatinine,radiologic findings,management techniques,number of surgical interventions,modified Clavien-Dindo complications,follow-up,and mortality,if any.Results:Forty patients were included in the study.The median age was 52(range 6-85)years.Of the total,25(62.5%)patients had a“significant”stent load;31(77.5%)had renal failure or acute kidney injury on presentation;19(47.5%)patients had sepsis at presentation.Among the patients presented with sepsis,11(57.9%)patients demonstrated a positive urine culture;and 7/11(63.6%)patients exhibited pan-resistant organisms.Twelve out of 40(30.0%)patients in our series developed high-grade Clavien-Dindo complications.On univariate analysis,sepsis at presentation(p=0.007),stent load(p=0.031),diabetes(p=0.023),positive urine culture(p=0.007),and stent indwelling time of more than 1 year(p=0.031)were found to be significant.On multivariate logistic regression analysis,sepsis at presentation(p=0.017)and positive urine culture(p=0.016)were significant predictors for high-grade complications.Conclusion:It is prudent to identify specific risk factors,namely sepsis at presentation and positive urine culture to triage and optimize these patients before surgical management.
文摘Patients with malignant biliary obstruction,following endoscopic retrograde cholangiopancreatography(ERCP)failure could be referred for endoscopicultrasound-guided biliary drainage through electrocautery-enhanced(ECE)lumen-apposing metal stent(LAMS)placement.However,the efficacy and safety of ECE-LAMS in this scenario have remained debatable due to minimal scientific evidence.The current confirmed 91.0%clinical success,96.7%technical success,7.3%reintervention rate,and 17.5%adverse events,following the treatment of malignant biliary obstruction with ECE-LAMS delivery.Finally,ECE-LAMS proved to be a generalizable strategy for managing biliary obstruction for patients who were excluded from ERCP.
文摘Background: Implementing invasive procedures is an important part of patient management by clinical nurses;however, there are gaps between nurses’ actual knowledge and skills and expected professional care capacity. Purpose: This scoping review aimed to map the existing literature related to recent institution-provided educational programs for invasive procedures involving clinical nurses. This study seeks to understand the contents of educational programs and the methods for assessing educational effects. Methods: This scoping review was completed using the following four databases: PubMed (MEDLINE), Embase, Cochrane Library, and Emcare for the period 2000-2022. We included studies that used all forms of educational approaches (e.g., didactic lectures, hands-on training, or on-the-job training). This scoping review considered peer-reviewed publications published in English using quantitative, qualitative, or mixed approaches. A total of 83 studies underwent in the final analysis. Results and Conclusion: A combination of didactic lectures and hands-on training was provided as an educational program in most studies. Contrary to our prediction, educational interventions with advanced technologies such as VR are extremely rare, suggesting that the effectiveness of advanced technologies in learning invasive procedures should be examined to facilitate and retain educational effects more efficiently in future studies. Regarding the assessment of educational effects, nurses’ cognitive (i.e., theoretical knowledge about procedures), psychomotor (i.e., implementing procedures), and psychological aspects (e.g., confidence and self-efficacy in procedures) were evaluated using questionnaires and observational methods. While most studies used a one-group pretest-posttest design, the ratio of randomized controlled trials (RCT) was relatively low. Thus, an RCT design should be introduced in future studies to test the validity of the developed educational program more accurately.
文摘Background: Prenatal diagnosis is the process of evaluating the presence of disease or potential disease in the fetus, this enables families to be better prepared before the birth of the baby. There are non-invasive prenatal diagnosis procedures and invasive prenatal diagnosis procedures. The invasive prenatal diagnosis procedures are CVS (chorionic villus sampling) and amniocentesis. The American College of Obstetricians and Gynecologists states that invasive diagnostic testing should be available to all women, regardless of age or risk. Objective: To determine the indications, outcome and results of diagnostic invasive prenatal procedures. Study setting: The obstetrics and Gynecology Department in Salmaniya Medical Complex in Kingdom of Bahrain. Study design: Retrospective descriptive study. Study subjects and Methods: This retrospective descriptive study was conducted on 175 pregnant women who underwent invasive prenatal procedures (CVS and amniocentesis) between January 2013 and December 2018 at SMC in Kingdom of Bahrain. All medical records of the participants were reviewed and entered the study. According to the implemented procedures, medical records were categorized into two chorionic villus sampling (CVS) and amniocentesis groups. The study subject will include indications of the procedures which are advanced maternal age, hematological disorders, genetic disorders, metabolic disorders, abnormal structural findings in fetal ultrasound and previous child with aneuploidy. In addition, the study will address the complications, outcome and results of procedures. Results: About half of our indications of the procedures were due to hematological disorders (47.6%) followed by abnormal structural findings in fetal ultrasound (30.1%) then genetic disorders (15.7%), metabolic disorders (4.8%) and advanced maternal age (1.8%). Regarding complications of the procedure;threatened miscarriage or loss of pregnancy within 3 weeks was (2.3%), amniotic fluid leakage (0.7%), abdominal cramps (0.7%) and Insufficient or contaminated sample (6.2%). Regarding outcome of the pregnancy, our results showed that the loss of pregnancy was (4.8%), intrauterine fetal death or still birth was (13.9%), live birth was (63.9%), preterm delivery was (7.8%), preterm premature rupture of membrane (PPROM) was (1.8%), limbs reduction was (0.0%). Termination of pregnancy outside the country was (7.8%) of chorionic villus sampling and amniocentesis. Conclusion: CVS and amniocentesis are useful outpatient procedures to detect diagnosis or to assess whether a patient is at increased risk of having an affected fetus and that will minimize the psychological impact on the patient and to provide a proper antenatal care to the pregnant women by her obstetrician and follow up to the baby by pediatrician. In this study it was observed that most of the patients who underwent the procedure were couples either carrier or affected to sickle cell disease or Beta thalassemia.
文摘The role of endoscopy in pathologies of the bile duct and gallbladder has seen notable advancements over the past two decades.With advancements in stent technology,such as the development of lumen-apposing metal stents,and adoption of endoscopic ultrasound and electrosurgical principles in therapeutic endoscopy,what was once considered endoscopic failure has transformed into failure of an approach that could be salvaged by a second-or third-line endoscopic strategy.Incorporation of these advancements in routine patient care will require formal training and multidisciplinary acceptance of established techniques and collaboration for advancement of experimental techniques to generate robust evidence that can be utilized to serve patients to the best of our ability.
文摘BACKGROUND In severe cases of coronary artery disease,percutaneous coronary intervention provide promising results.The stent used could be a drug-eluting stent(DES)or a titanium-nitride-oxide coated stent(TiNOS).AIM To compare the 5-year effectiveness and safety of the two stent types.METHODS The following systematic review and meta-analysis was conducted in accordance with the preferred reporting items for systematic reviews and meta-analysis guidelines,and PubMed/MEDLINE,Scopus,and Cochrane Central were searched from inception till August 2023.Primary outcomes were major adverse cardiac events(MACE),cardiac death,myocardial infarction(MI),cardiac death or MI,and ischemia-driven total lesion revascularization(ID-TLR).RESULTS Four randomized controlled trials(RCT),which analyzed a sum total of 3045 patients with acute coronary syndrome(ACS)after a median follow-up time of 5 years were included.Though statistically insignificant,an increase in the ID-TLR was observed in patients receiving TiNOSs vs DESs.In addition,MI,cardiac death and MI,and definite stent thrombosis(DST)were significantly decreased in the TiNOS arm.Baseline analysis revealed no significant results with meta-regression presenting non-ST elevated MI(NSTEMI)as a statistically significant covariate in the outcome of MACE.CONCLUSION TiNOS was found to be superior to DES in terms of MI,cardiac death or MI,and DST outcomes,however,the effect of the two stent types on ID-TLR and MACE was not significant.A greater number of studies are required to establish an accurate comparison of patient outcomes in TiNOS and DES.
基金2024 Natural Science Joint Foundation of Zhejiang Province,No.LBY24H040007.
文摘BACKGROUNDAlmost all cases of cervical cancer can be attributed to human papillomavirus(HPV) infection. The loop electrosurgical excision procedure (LEEP) is widelyused to treat HPV-mediated disease;thus, cervical cancer is highly preventable.However, LEEP does not necessarily clear HPV rapidly and may affect theaccuracy of the results of ThinPrep cytology test (TCT) and cervical biopsy due tothe formation of cervical scars.CASE SUMMARYA 40-year-old woman underwent LEEP for cervical intraepithelial neoplasia grade1 approximately 10 years ago. Subsequent standard cervical cancer screeningsuggested persistent HPV-52 infection, but TCT results were negative. Cervicalbiopsy under colposcopy was performed thrice over a 10-year period, yieldingnegative pathology results. She developed abnormal vaginal bleeding after sexualactivity, persisting for approximately 1 year, and underwent hysteroscopy in ourhospital. Histopathologic evaluation confirmed adenocarcinoma in situ of theuterine cervix.CONCLUSIONPatients with long-term persistent, high-risk HPV infection and negative pathologyresults of cervical biopsy after LEEP are at risk of cervical cancer. Hysteroscopicresection of cervical canal tissue is recommended as a supplement tocervical biopsy because it helps define the lesion site and may yield a pathologicdiagnosis.
文摘This paper primarily concerns the effective coordination of the procedures and methods employed in open pit mining operations under the background of river management.The central objective of this study is to identify a viable approach for ensuring rational and efficient development of open pit mineral resources while simultaneously protecting and restoring the ecological environment of the river.This approach should facilitate the realization of a harmonious symbiosis between mining and river management.The intricate mutual influence relationship between river management and open pit mining is first analyzed in depth,which provides a solid foundation for the subsequent coordination strategy development.In light of the aforementioned considerations,a set of coordination procedures for open pit mining based on river management conditions is proposed.These procedures emphasize the integration of river protection into the overall layout of mining at the planning stage.The implementation of scientific mining schemes,accompanied by rigorous control of the scope and depth of mining operations,has proven to be an effective means of reducing the impact of mining activities on river environments.This approach has also facilitated the achievement of a balance and coordination between mining and river management.
文摘This editorial delves into Peng et al's article,published in the World Journal of Gastrointestinal Surgery.Peng et al's meta-analysis investigates the effectiveness of electrocautery-enhanced lumen-apposing metal stents(ECE-LAMS)in ultrasound-guided biliary drainage for alleviating malignant biliary obstruction.Examining 14 studies encompassing 620 participants,the research underscores a robust technical success rate of 96.7%,highlighting the efficacy of ECE-LAMS,particularly in challenging cases which have failed endoscopic retrograde cholangio pancreatography.A clinical success rate of 91.0% underscores its impact on symptom alleviation,while a reasonably tolerable adverse event rate of 17.5% is observed.However,the 7.3% re-intervention rate stresses the need for post-procedural monitoring.Subgroup analyses validate consistent outcomes,bolstering the applicability of ECE-LAMS.These findings advocate for the adoption of ECELAMS as an appropriate approach for biliary palliation,urging further exploration in real-world clinical contexts.They offer valuable insights for optimizing interventions targeting malignant biliary obstruction management.
文摘In this editorial,we comment on the article by Peng et al.Palliative drainage for biliary obstruction resulting from unresectable malignant lesions includes internal and external drainage.The procedures of biliary drainage are usually guided by fluoroscopy or transcutaneous ultrasound,endoscopic ultrasound(EUS),or both.Endoscopic retrograde cholangiopancreatography(ERCP)has been primarily recommended for the management of biliary obstruction,while EUS-guided biliary drainage and percutaneous transhepatic biliary drainage(PTBD)are alternative choices for cases where ERCP has failed or is impossible.PTBD is limited by shortcomings of a higher rate of adverse events,more reinterventions,and severe complications.EUS-guided biliary drainage has a lower rate of adverse events than PTBD.EUS-guided biliary drainage with electrocautery-enhanced lumen-apposing metal stent(ECE-LAMS)enables EUS-guided biliaryenteric anastomosis to be performed in a single step and does not require prior bile duct puncture or a guidewire.The present meta-analysis showed that ECELAMS has a high efficacy and safety in relieving biliary obstruction in general,although the results of LAMS depending on the site of biliary obstruction.This study has highlighted the latest advances with a larger sample-based comprehensive analysis.
文摘BACKGROUND Endoscopic management is the first-line therapy for post-liver-transplant anas-tomotic strictures.Although the optimal duration of treatment with plastic stents has been reported to be 8-12 months,data on safety and duration for metal stents in this setting is scarce.Due to limited access to endoscopic retrograde cholan-giopancreatography(ERCP)during the coronavirus disease 2019 pandemic in our centre,there was a change in practice towards increased usage and length-of-stay of the Kaffes biliary intraductal self-expanding stent in patients with suitable anatomy.This was mainly due to the theoretical benefit of Kaffes stents allowing for longer indwelling periods compared to the traditional plastic stents.METHODS Adult liver transplant recipients aged 18 years and above who underwent ERCP were retrospectively identified during a 10-year period through a database query.Unplanned admissions post-Kaffes stent insertion were identified manually through electronic and scanned medical records.The main outcome was the incidence of complications when stents were left indwelling for 3 months vs 6 months.Stent efficacy was calculated via rates of stricture recurrence between patients that had stenting courses for≤120 d or>120 d.RESULTS During the study period,a total of 66 ERCPs with Kaffes insertion were performed in 54 patients throughout their stenting course.In 33 ERCPs,the stent was removed or exchanged on a 3-month interval.No pancreatitis,perfor-ations or deaths occurred.Minor post-ERCP complications were similar between the 3-month(abdominal pain and intraductal migration)and 6-month(abdominal pain,septic shower and embedded stent)groups-6.1%vs 9.1%respectively,P=0.40.All strictures resolved at the end of the stenting course,but the stenting course was variable from 3 to 22 months.The recurrence rate for stenting courses lasting for up to 120 d was 71.4%and 21.4%for stenting courses of 121 d or over(P=0.03).There were 28 patients that were treated with a single ERCP with Kaffes,21 with removal after 120 d and 7 within 120 d.There was a significant improvement in stricture recurrence when the Kaffes was removed after 120 d when a single ERCP was used for the entire stenting course(71.0%vs 10.0%,P=0.01).CONCLUSION Utilising a single Kaffes intraductal fully-covered metal stent for at least 4 months is safe and efficacious for the management of post-transplant anastomotic strictures.
基金2022 Discipline Construction Project of School of Business Administration,Shenyang Pharmaceutical University(2022-SYGSXK-05).
文摘Objective To study the impact of the first national centralized procurement of coronary stents on patients’psychology,the economy of medical institutions,and the survival and development of the coronary stents industry,and to provide suggestions on perfecting procedures to better carry out the centralized procurement of coronary stents.Methods Literature analysis was used to investigate the results of the procurement of coronary stent in a province and a hospital.Results and Conclusion The centralized procurement of coronary stents has alleviated the economic pressure of patients,but it has many problems.Therefore,this paper proposes some suggestions,such as promoting the orderly development of the coronary stent industry,improving the evaluation link of the centralized procurement of coronary stents,adopting the accurate reporting model to ensure the quality of coronary stents and improving the standardization of clinical services.
基金supported by grants from the National Natural Science Foundation of China(No.81873694)the Key Research and Development Program of Hubei Province(No.2021BCA119 and No.2022BCA005)Knowledge Innovation Program of Wuhan-Basic Research(No.2022020801010446).
文摘Objective To identify factors affecting the efficacy of steroid-eluting sinus stents implanted after endoscopic sinus surgery(ESS)in patients with chronic rhinosinusitis with nasal polyps(CRSwNP).Methods We performed a post-hoc analysis of a randomized self-controlled clinical trial on post-operative implantation of bioabsorbable steroid-eluting stents in patients with CRSwNP.Univariate logistic regression analysis was conducted to identify which of the following factors affect the response to post-operative stent implantation:sex,serum eosinophil levels,history of prior surgery,endoscopic scores,and comorbid conditions(asthma and allergic rhinitis).The primary outcome was the rate of post-operative intervention on day 30,and the secondary outcome was the rate of polypoid tissue formation(grades 2–3)on days 14,30,and 90.Results A total of 151 patients with CRSwNP were included in the post-hoc analysis.Asthma was identified as the only risk factor for a poor response to steroid-eluting sinus stents on post-operative day 30,with an odds ratio of 23.71(95%CI,2.81,200.16;P=0.004)for the need for post-operative intervention and 19(95%CI,2.20,164.16;P=0.003)for moderate-to-severe polypoid tissue formation.In addition,the asthmatic group showed higher rates of post-operative intervention and polypoid tissue formation than the non-asthmatic group on post-operative day 30.Blood eosinophil levels were not identified as a risk factor for poor outcomes after stent implantation.Conclusion Comorbid asthma,but not blood eosinophil level,impairs the efficacy of steroid-eluting sinus stents in the short term after ESS in patients with CRSwNP.
文摘There is still significant debate regarding the best surgical treatment for malignant left-sided large bowel obstruction.Primary resection and anastomosis offers the advantages of a definite procedure without need for further surgery.Its main disadvantages are related to the increased technical challenge and to the potential higher risk of anastomotic leakage that occurs in the emergency setting.Primary resection with end colostomy(Hartmann's procedure) is considered the safer option.Tan et al compared in a systematic review and meta-analysis the use of self-expanding metallic stents(SEMS) as a bridge to surgery vs emergency surgery in the management of acute malignant left-sided large bowel obstruction.The authors concluded that the technical and clinical success rates for stenting were lower than expected.SEMS was associated with a high incidence of clinical and silent perforation.Stenting instead of loop colostomy can be recommended only if the appropriate expertise is available in the hospital.The goal of stenting,a decrease of the stoma rate,may be advocated only if the complication rates of stenting are lower than those of stoma creation in the emergency situation.Until now,this was not demonstrated in a prospective randomized trial.
文摘Colonic stenting has had a significant positive impact on the management of obstructive left-sided colon cancer(OLCC) in terms of both palliative treatment and bridge-to-surgery(BTS). Notably, many studies have convincingly demonstrated the effectiveness of stenting as a BTS, resulting in improvements in shortterm outcomes and quality of life, safety, and efficacy in subsequent curative surgery, and increased cost-effectiveness, whereas the safety of chemotherapy after stenting and the long-term outcomes of stenting as a BTS are controversial. Several studies have suggested an increased risk of perforation in patients receiving bevacizumab chemotherapy after colonic stenting. In addition, several pathological analyses have suggested a negative oncological impact of colonic stenting. In contrast, many recent studies have demonstrated that colonic stenting for OLCC does not negatively impact the safety of chemotherapy or long-term oncological outcomes. The updated version of the European Society of Gastrointestinal Endoscopy guidelines released in 2020 included colonic stenting as a BTS for OLCC as a recommended treatment. It should be noted that the experience of endoscopists is involved in determining technical and clinical success rates and possibly oncological outcomes. This review discusses the positive and negative impacts of colonic stenting on OLCC treatment, particularly in terms of oncology.
基金The authors have read the PRISMA 2009 Checklist,and the manuscript was prepared and revised according to the PRISMA 2009 Checklist.
文摘BACKGROUND Endoscopic ultrasound-guided biliary drainage using electrocautery-enhanced(ECE)delivery of lumen-apposing metal stent(LAMS)is gradually being re-cognized as a viable palliative technique for malignant biliary obstruction after endoscopic retrograde cholangiopancreatography(ERCP)failure.However,most of the studies that have assessed its efficacy and safety were small and hetero-geneous.Prior meta-analyses of six or fewer studies that were published 2 years ago were therefore underpowered to yield convincing evidence.AIM To update the efficacy and safety of ECE-LAMS for treatment of biliary ob-struction after ERCP failure.METHODS We searched PubMed,EMBASE,and Scopus databases from the inception of the ECE technique to May 13,2022.Primary outcome measure was pooled technical success rate,and secondary outcomes were pooled rates of clinical success,re-intervention,and adverse events.Meta-analysis was performed using a random-effects model following Freeman-Tukey double-arcsine transformation in R soft-ware(version 4.1.3).RESULTS Fourteen eligible studies involving 620 participants were ultimately included.The pooled rate of technical success was 96.7%,and clinical success was 91.0%.Adverse events were reported in 17.5%of patients.Overall reinter-vention rate was 7.3%.Subgroup analyses showed results were generally consistent.CONCLUSION ECE-LAMS has favorable success with acceptable adverse events in relieving biliary obstruction when ERCP is impossible.The consistency of results across most subgroups suggested that this is a generalizable approach.
文摘BACKGROUND Endoscopic placement of a self-expandable metal stent(SEMS)is a minimally invasive treatment for use in malignant and benign colonic obstruction.However,their widespread use is still limited with a nationwide analysis showing only 5.4%of patients with colon obstruction undergoing stent placement.This underutilization could be due to perceived increase risk of complications with stent placement.AIM To review long-and short-term clinical success of SEMS use for colonic obstruction at our center.METHODS We retrospectively reviewed all the patients who underwent colonic SEMS placement over aeighteen year period (August 2004 through August 2022) at our academic center. Demographicsincluding age, gender, indication (malignant and benign), technical success, clinical success,complications (perforation, stent migration), mortality, and outcomes were recorded.RESULTSSixty three patients underwent colon SEMS over an 18-year period. Fifty-five cases were formalignant indications, 8 were for benign conditions. The benign strictures included diverticulardisease stricturing (n = 4), fistula closure (n = 2), extrinsic fibroid compression (n = 1), and ischemicstricture (n = 1). Forty-three of the malignant cases were due to intrinsic obstruction from primaryor recurrent colon cancer;12 were from extrinsic compression. Fifty-four strictures occurred on theleft side, 3 occurred on the right and the rest in transverse colon. The total malignant case (n = 55)procedural success rate was 95% vs 100% for benign cases (P = 1.0, NS). Overall complication ratewas significantly higher for benign group: Four complications were observed in the malignantgroup (stent migration, restenosis) vs 2 of 8 (25%) for benign obstruction (1-perforation, 1-stentmigration) (P = 0.02). When stratifying complications of perforation and stent migration there wasno significant difference between the two groups (P = 0.14, NS).CONCLUSIONColon SEMS remains a worthwhile option for colonic obstruction related to malignancy and has ahigh procedural and clinical success rate. Benign indications for SEMS placement appear to havesimilar success to malignant. While there appears to be a higher overall complication rate inbenign cases, our study is limited by sample size. When evaluating for perforation alone theredoes not appear to be any significant difference between the two groups. SEMS placement may bea practical option for indications other that malignant obstruction. Interventional endoscopistsshould be aware and discuss the risk for complications in setting of benign conditions. Indicationsin these cases should be discussed in a multi-disciplinary fashion with colorectal surgery.
基金The Clinical Research Project of The First Affiliated Hospital of Shenzhen University,No.20223357030 and No.20223357021the“Double-First Class”Application Characteristic Discipline of Hunan Province(Pharmaceutical Science).
文摘BACKGROUND Mechanical thrombectomy is the most effective treatment for great cerebral artery embolization within a set time window.Typically,an arteriogram does not show the localization of the stent after release and whether a thrombus is captured or not.Thus,improving the visualization of a stent in interventional therapy will be helpful for clinicians.AIM To analyze stent imaging findings to enhance clinicians’understanding of a special circumstance,wherein a Solitaire AB retrievable stent was visible during the imaging of a thrombus capture that improved the success rate of stent-based mechanical thrombectomy.METHODS This was a retrospective study with four acute ischemic stroke(AIS)patients who underwent stent-based mechanical thrombectomy.RESULTS Patient 1 was a 64-year-old man admitted after 5 h of confusion;angiography revealed basilar artery occlusion.We inserted a stent into the left posterior cerebral artery-P2 segment and visualized the expanded stent that successfully captured a thrombus.Patient 2 was a 74-year-old man admitted with confusion,which lasted approximately 3 h.Angiography revealed a left middle cerebral artery(MCA)-M1 segment occlusion.A stent was deployed in the distal M2 segment,and we could visualize the stent by capturing the thrombus.Patient 3 was a 74-year-old woman admitted after experiencing left hemiplegia for 3 h.We deployed a stent at the distal right MCAM2 segment,and the developing stent captured a large thrombus.Patient 4 was an 82-year-old man who presented with confusion for 3 h.A developing stent was placed in the distal left MCA-M1 segment,which captured a large thrombus and several fragmented thrombi.CONCLUSION To the best of our knowledge,this is the first report of stent imaging in patients with AIS.We demonstrated the usefulness and substantial potential of stent imaging in stent-based mechanical thrombectomy for AIS.